Polestar 3

Climate parameters

The Polestar 3 has 10 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Auxiliary water pump duty cycle POLESTAR_AUXILIARY_WATER_PMP

  • Request22 43 36
  • Service 22DID 4336
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Auxiliary water pump duty cycle POLESTAR_AUXILIARY_WATER_PMP

  • Request22 43 36
  • Service 22DID 4336
  • ModuleD01A → 1F422E80
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 2024 to 2026.

Cabin blower command POLESTAR_BLOWER

  • Request22 34 CB
  • Service 22DID 34CB
  • Module7E4 → 7EC
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 100 %
Unit
%

In testing for 2024 to 2026.

Evaporator temperature, variant 2 POLESTAR_EVAPORATOR_T_V_2

  • Request22 98 20
  • Service 22DID 9820
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 16 ÷ 5)
Range
-409 to 406 °C
Unit
°C

In testing for 2024 to 2026.

Fuel-operated heater, inlet water temperature POLESTAR_FOH_INLET_WATER_T

  • Request22 43 BE
  • Service 22DID 43BE
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Fuel-operated heater, outlet water temperature POLESTAR_FOH_OUTLET_WATER_T

  • Request22 43 BE
  • Service 22DID 43BE
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Heat exchanger temperature POLESTAR_HEAT_EXCHANGER_T

  • Request22 98 50
  • Service 22DID 9850
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 °C
Unit
°C

In testing for 2024 to 2026.

Heat exchanger temperature, variant 2 POLESTAR_HEAT_EXCHANGER_T_V_2

  • Request22 43 37
  • Service 22DID 4337
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 16 ÷ 5)
Range
-409 to 406 °C
Unit
°C

In testing for 2024 to 2026.

High-voltage coolant heater coolant inlet temperature POLESTAR_HVCH_CLT_INLET_T

  • Request22 43 44
  • Service 22DID 4344
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

High-voltage coolant heater coolant outlet temperature POLESTAR_HVCH_CLT_OUTLET_T

  • Request22 43 44
  • Service 22DID 4344
  • ModuleD01A → 1F422E80
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2024 to 2026.

Outside temperature POLESTAR_AAT

  • Request22 20 0C
  • Service 22DID 200C
  • Module743 → 763
  • Every20 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 2024 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.