Engine parameters
The Peugeot 505 has 355 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
5V power supply state number 1 PEUGEOT_5V_POWER_SUP_ST_1
- Request
22 D4 23 - Service 22
DID D423 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
5V power supply state number 2 PEUGEOT_5V_POWER_SUP_ST_2
- Request
22 D4 24 - Service 22
DID D424 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
5V power supply state number 3 PEUGEOT_5V_POWER_SUP_ST_3
- Request
22 D4 25 - Service 22
DID D425 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
5V power supply state number 4 PEUGEOT_5V_POWER_SUP_ST_4
- Request
22 D4 26 - Service 22
DID D426 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
12V network allowed stop PEUGEOT_12V_NETWORK_ALLOWED
- Request
22 D7 4C - Service 22
DID D74C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Activation count, brake electromagnetic valve B1 PEUGEOT_NUM_ACTIVATIONS_B1
- Request
22 D7 45 - Service 22
DID D745 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Activation count, line pressure control solenoid PEUGEOT_NUM_LINE_P_CTRL
- Request
22 D7 51 - Service 22
DID D751 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Activation count, the electromagnetic valve of brake B2 PEUGEOT_NUM_ACTIVATIONS_B2
- Request
22 D7 5A - Service 22
DID D75A - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Actual oil pressure PEUGEOT_ACT_OIL_P
- Request
21 C5 - Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 20)- Range
- 0 to 12.75 bar
- Unit
- bar
In testing for 1988 to 1992, 2018 to 2019.
Additional heater control 1 PEUGEOT_ADDITIONAL_HEATER_1
- Request
22 D4 16 - Service 22
DID D416 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
AFT DPF oulet pressure sensor PEUGEOT_AFT_DPF_OULET_P_SENS
- Request
22 A0 0A - Service 22
DID A00A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 2000)- Range
- 0 to 294 psi
- Unit
- psi
In testing for 1988 to 1992, 2018 to 2019.
Air conditioning PEUGEOT_AC
- Request
22 D4 AF - Service 22
DID D4AF - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Air conditioning compressor current PEUGEOT_AC_COMP_CURRENT
- Request
22 D4 1C - Service 22
DID D41C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25)- Range
- 0 to 6375
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Air conditioning high side pressure PEUGEOT_AC_HIGH_SIDE_P
- Request
22 D8 FF - Service 22
DID D8FF - Module
6A2 → 682 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 bar
- Unit
- bar
In testing for 1988 to 1992, 2018 to 2019.
Air conditioning high side pressure PEUGEOT_AC_HIGH_SIDE_P_7E0
- Request
21 A7 - Service 21
PID A7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 55)- Range
- 0 to 1191 psi
- Unit
- psi
In testing for 1988 to 1992, 2018 to 2019.
Air conditioning high side pressure PEUGEOT_AC_HIGH_SIDE_P_V2
- Request
22 03 29 - Service 22
DID 0329 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 14)- Range
- 0 to 3570 kPa
- Unit
- kPa
In testing for 1988 to 1992, 2018 to 2019.
Air conditioning pressure PEUGEOT_AC_P
- Request
22 D4 21 - Service 22
DID D421 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 1988 to 1992, 2018 to 2019.
Air conditioning refrigerant pressure PEUGEOT_AC_REFRIGERANT_P
- Request
22 40 01 - Service 22
DID 4001 - Module
DA42 → 42 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 bar
- Unit
- bar
In testing for 1988 to 1992, 2018 to 2019.
Air doser first electronic loading PEUGEOT_AIR_DOSER_FIRST
- Request
22 D5 3B - Service 22
DID D53B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Air flow PEUGEOT_AIR_FLOW
- Request
22 D4 89 - Service 22
DID D489 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Air flow target PEUGEOT_AIR_FLOW_TGT
- Request
22 D4 8E - Service 22
DID D48E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Air heater core temperature PEUGEOT_AIRHEATER_CORE_T
- Request
22 40 55 - Service 22
DID 4055 - Module
DA42 → 42 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Air heater current PEUGEOT_AIRHEATER_CURRENT
- Request
22 40 55 - Service 22
DID 4055 - Module
DA42 → 42 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 A
- Unit
- A
In testing for 1988 to 1992, 2018 to 2019.
Air heater power consumption PEUGEOT_AIRHEATER_POWER_CONS
- Request
22 40 55 - Service 22
DID 4055 - Module
DA42 → 42 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Air metering valve duty cycle PEUGEOT_AIR_METERING_VLV
- Request
22 D4 61 - Service 22
DID D461 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Air metering valve position PEUGEOT_AIR_METERING_VLV_POS
- Request
22 D5 4F - Service 22
DID D54F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Air metering valve, target position PEUGEOT_AIR_METERING_VLV_TGT
- Request
22 D4 60 - Service 22
DID D460 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Air temperature by air flow meter PEUGEOT_AIR_T_AIR_FLOW_METER
- Request
22 D5 4E - Service 22
DID D54E - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Alternator load value PEUGEOT_ALTERNATOR_LOAD
- Request
22 D4 A5 - Service 22
DID D4A5 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Ambient air temperature PEUGEOT_AAT_6A9
- Request
22 D5 52 - Service 22
DID D552 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Ambient air temperature PEUGEOT_AAT_7E0
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Ambient temperature PEUGEOT_AAT
- Request
22 D4 34 - Service 22
DID D434 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Ambient temperature PEUGEOT_AAT_V2
- Request
22 01 27 - Service 22
DID 0127 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 83)- Range
- -83 to 376 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
ANTI START PROGRAMMING STATUS PEUGEOT_ANTI_START
- Request
22 DA DC - Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Assessment of thermal aging of the particulate filter PEUGEOT_ASSESSMENT_THERMAL
- Request
22 D5 32 - Service 22
DID D532 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 25 ÷ 128)- Range
- 0 to 12799 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
AT main cylinder pressure PEUGEOT_MAIN_CYL_P
- Request
22 50 34 - Service 22
DID 5034 - Module
7E1 → 7E9 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513 bar
- Unit
- bar
In testing for 1988 to 1992, 2018 to 2019.
Atmospheric pressure PEUGEOT_ATMOSPHERIC_P
- Request
22 D4 65 - Service 22
DID D465 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Automatic restart request from body control module PEUGEOT_AUTOMATIC_RESTART_REQ_BSI
- Request
22 D7 0A - Service 22
DID D70A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Automatic restart request from engine management computer PEUGEOT_AUTOMATIC_RESTART
- Request
22 D7 09 - Service 22
DID D709 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Automatic stop allowed by body control module PEUGEOT_AUTOMATIC_STOP
- Request
22 D7 03 - Service 22
DID D703 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Automatic stop allowed by power steering computer PEUGEOT_AUTOMATIC_STOP_ALLOWED_POWER_STEER
- Request
22 D7 05 - Service 22
DID D705 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Automatic transmission fluid temperature PEUGEOT_ATF_T_3RDGEN
- Request
21 18 - Service 21
PID 18 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64 − 40)- Range
- -40 to 983.9843 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Auxiliary heater 2 control PEUGEOT_AUXILIARY_HEATER_2
- Request
22 D4 17 - Service 22
DID D417 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Average mileage for the last 10 regenerations PEUGEOT_AVG_MILEAGE_LAST_10
- Request
22 D5 25 - Service 22
DID D525 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 16)- Range
- 0 to 4095 km
- Unit
- km
In testing for 1988 to 1992, 2018 to 2019.
Barometric pressure PEUGEOT_BAROMETRIC_P
- Request
22 01 09 - Service 22
DID 0109 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kPa
- Unit
- kPa
In testing for 1988 to 1992, 2018 to 2019.
Boost air temperature PEUGEOT_BOOST_AIR_T
- Request
22 D4 11 - Service 22
DID D411 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Boost pressure PEUGEOT_BOOST_P
- Request
22 A0 54 - Service 22
DID A054 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 435)- Range
- 0 to 150 psi
- Unit
- psi
In testing for 1988 to 1992, 2018 to 2019.
Boost pressure estimate PEUGEOT_BOOST_P_ESTIMATE
- Request
21 B2 - Service 21
PID B2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 441)- Range
- 0 to 148 psi
- Unit
- psi
In testing for 1988 to 1992, 2018 to 2019.
Button state PEUGEOT_BUTTON_ST
- Request
22 D5 17 - Service 22
DID D517 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Cam crank difference PEUGEOT_CAM_CRANK_DIFF
- Request
22 05 9E - Service 22
DID 059E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °
- Unit
- °
In testing for 1988 to 1992, 2018 to 2019.
Camshaft/crankshaft position synchronization PEUGEOT_CAM_CRANK_POS
- Request
22 D4 18 - Service 22
DID D418 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Catalyst modeled temperature PEUGEOT_CAT_MODEL_T
- Request
22 01 2B - Service 22
DID 012B - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 1000 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
CHANGE REPORT IN PROGRESS PEUGEOT_CHANGE_REPORT
- Request
22 D5 16 - Service 22
DID D516 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Closed loop soot load assessment of the diesel particulate filter PEUGEOT_CLOSED_LOOP_SOOT
- Request
22 D5 4B - Service 22
DID D54B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1024)- Range
- 0 to 63.99 g/L
- Unit
- g/L
In testing for 1988 to 1992, 2018 to 2019.
Combustion engine state PEUGEOT_ICE_ST
- Request
22 D7 09 - Service 22
DID D709 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Commanded oil pressure PEUGEOT_CMD_OIL_P
- Request
21 C5 - Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 bar
- Unit
- bar
In testing for 1988 to 1992, 2018 to 2019.
Commanded power PEUGEOT_CMD_POWER
- Request
22 19 97 - Service 22
DID 1997 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Computer lock PEUGEOT_COMPUTER_LOCK
- Request
22 DA DD - Service 22
DID DADD - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Computer remote wake-up state PEUGEOT_COMPUTER_WAKE_UP_ST
- Request
22 D5 15 - Service 22
DID D515 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Computer restarts since memory erase PEUGEOT_CNT_NUM_RE
- Request
22 D4 D8 - Service 22
DID D4D8 - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Computer temperature PEUGEOT_COMPUTER_T
- Request
22 D4 35 - Service 22
DID D435 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Control current of electromagnetic valve for changing the pressure in the brake system B2 PEUGEOT_CTRL_CURRENT_P_B2
- Request
22 D6 22 - Service 22
DID D622 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 1992, 2018 to 2019.
Control current of the electromagnetic valve for changing the pressure in the brake system B1 PEUGEOT_CTRL_CURRENT_P_B1
- Request
22 D6 08 - Service 22
DID D608 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 1992, 2018 to 2019.
Controlled air supply module PEUGEOT_CONTROLLED_AIR_SUP
- Request
22 D4 A0 - Service 22
DID D4A0 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Coolant temperature PEUGEOT_ECT
Pelican can show this parameter as the engine coolant temperature.
- Request
22 D8 FB - Service 22
DID D8FB - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Coolant temperature PEUGEOT_ECT_6A8
Pelican can show this parameter as the engine coolant temperature.
- Request
22 D4 15 - Service 22
DID D415 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Coolant temperature PEUGEOT_ECT_ECU
- Request
22 10 03 - Service 22
DID 1003 - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 100 − 40)- Range
- -40 to 200 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Coolant temperature target PEUGEOT_ECT_TGT
- Request
22 D4 0D - Service 22
DID D40D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Coolant temperature, corrected PEUGEOT_ECT_CORRECTED
- Request
22 D4 0A - Service 22
DID D40A - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Crankcase differential pressure PEUGEOT_CRANKCASE_DIFF_P
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 328 to 343 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Crankcase pressure PEUGEOT_CRANKCASE_P
- Request
21 B2 - Service 21
PID B2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 1761)- Range
- 0 to 37.21 psi
- Unit
- psi
In testing for 1988 to 1992, 2018 to 2019.
Cruise control, RW status PEUGEOT_CRUISE_CTRL_RW_STAT
- Request
22 D4 B0 - Service 22
DID D4B0 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Cylinder 1 injector flow correction PEUGEOT_CYL_1_INJ_FLOW_CORR
- Request
22 D5 46 - Service 22
DID D546 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Cylinder 2 injector flow correction PEUGEOT_CYL_2_INJ_FLOW_CORR
- Request
22 D5 47 - Service 22
DID D547 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Cylinder 3 injector flow correction PEUGEOT_CYL_3_INJ_FLOW_CORR
- Request
22 D5 48 - Service 22
DID D548 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Cylinder 4 injector flow correction PEUGEOT_CYL_4_INJ_FLOW_CORR
- Request
22 D5 49 - Service 22
DID D549 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Date PEUGEOT_DATE
- Request
22 D4 CA - Service 22
DID D4CA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 s
- Unit
- s
In testing for 1988 to 1992, 2018 to 2019.
DEF dosing rate, gph PEUGEOT_DEF_DOSING_RATE_GPH
- Request
22 A1 29 - Service 22
DID A129 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
DEF level PEUGEOT_DEF_LEVEL
- Request
22 A0 06 - Service 22
DID A006 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
DEF quality PEUGEOT_DEF_QUALITY
- Request
22 A1 2B - Service 22
DID A12B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
DEF temperature PEUGEOT_DEF_T
- Request
22 A0 04 - Service 22
DID A004 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Diesel fuel temperature PEUGEOT_FUEL_TEMP
- Request
22 19 00 - Service 22
DID 1900 - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 100 − 40)- Range
- -40 to 200 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Diesel particulate filter delta pressure PEUGEOT_DPF_DELTA_P
- Request
21 D6 - Service 21
PID D6 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 73 ÷ 500)- Range
- 0 to 37.2299 psi
- Unit
- psi
In testing for 1988 to 1992, 2018 to 2019.
Diesel particulate filter differential pressure PEUGEOT_DPF_DIFF_P
- Request
22 18 E2 - Service 22
DID 18E2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 32768)- Range
- -32768 to -26214.5
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Diesel particulate filter differential pressure sensor signal deviation from reference value PEUGEOT_DPF_DIFF_P_SENS_SIG
- Request
22 D5 18 - Service 22
DID D518 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Diesel particulate filter flow resistance PEUGEOT_DPF_FLOW_RES_V2
- Request
22 01 E2 - Service 22
DID 01E2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10000)- Range
- -3.2768 to 3.2767
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Diesel particulate filter inlet gas temperature PEUGEOT_INLET_DPF_GAS_T
- Request
22 18 DE - Service 22
DID 18DE - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.019608 − 40)- Range
- -40 to 1245.0102 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Diesel particulate filter regen active PEUGEOT_DPF_REGEN_ACTIVE_7E0
- Request
21 D8 - Service 21
PID D8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 79 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 1992, 2018 to 2019.
Diesel particulate filter regeneration PEUGEOT_DPF_REGEN
- Request
21 48 - Service 21
PID 48 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 383 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 1992, 2018 to 2019.
Diesel particulate filter regeneration status PEUGEOT_DPF_REGEN_STAT
- Request
22 D5 21 - Service 22
DID D521 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Diesel particulate filter soot load PEUGEOT_DPF_SOOT_LOAD
- Request
22 01 E2 - Service 22
DID 01E2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 g/L
- Unit
- g/L
In testing for 1988 to 1992, 2018 to 2019.
Diesel particulate filter soot mass PEUGEOT_DPF_SOOT_MASS
- Request
22 18 E4 - Service 22
DID 18E4 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 763 ÷ 50000)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Differential pressure at particulate filter PEUGEOT_DIFF_P_PF
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Drive motor coolant inlet temperature PEUGEOT_DRIVE_MOTOR_CLT_T
- Request
22 D8 D6 - Service 22
DID D8D6 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Drive motor coolant inlet temperature PEUGEOT_EMOTOR_CLT_INLET_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Drive motor coolant outlet temperature PEUGEOT_EMOTOR_CLT_OUTLET_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Drive motor inverter temperature 0 PEUGEOT_EMOTOR_INVERTER_T_0
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Drive motor inverter temperature 1 PEUGEOT_EMOTOR_INVERTER_T_1
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Drive motor inverter temperature 2 PEUGEOT_EMOTOR_INVERTER_T_2
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Drive motor inverter temperature model PEUGEOT_EMOTOR_INVERTER_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Drive motor PCB temperature PEUGEOT_EMOTOR_PCB_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Drive motor power PEUGEOT_DRIVE_MOTOR_POWER
- Request
22 D8 D9 - Service 22
DID D8D9 - Module
6A2 → 682 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 100)- Range
- -3276800 to 3276700 W
- Unit
- W
In testing for 1988 to 1992, 2018 to 2019.
Drive motor rotor temperature PEUGEOT_EMOTOR_ROTOR_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Drive motor stator temperature PEUGEOT_DRIVE_MOTOR_STATOR_T
- Request
22 D8 CD - Service 22
DID D8CD - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Drive motor stator temperature PEUGEOT_EMOTOR_STATOR_T
- Request
22 30 65 - Service 22
DID 3065 - Module
DA42 → 42 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Drive motor torque achieved PEUGEOT_EMOTOR_TQ_ACHIEVED
- Request
22 30 64 - Service 22
DID 3064 - Module
DA42 → 42 - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 50 − 500)- Range
- -500 to 810 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Drive motor torque limit PEUGEOT_EMOTOR_TQ_LIM
- Request
22 30 63 - Service 22
DID 3063 - Module
DA42 → 42 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50 − 500)- Range
- -500 to 810 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Drive motor torque, actual PEUGEOT_DRIVE_MOTOR_TQ_ACT
- Request
22 D8 D0 - Service 22
DID D8D0 - Module
6A2 → 682 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Drive motor torque, commanded PEUGEOT_EMOTOR_TQ_CMD
- Request
22 30 64 - Service 22
DID 3064 - Module
DA42 → 42 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50 − 500)- Range
- -500 to 810 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Drive motor torque, desired PEUGEOT_DRIVE_MOTOR_TQ_DES
- Request
22 D8 80 - Service 22
DID D880 - Module
6A2 → 682 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327 to 327 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Driver presence PEUGEOT_DRIVER_PRESENCE
- Request
22 D7 23 - Service 22
DID D723 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Driver, requested torque value PEUGEOT_DRIVER_REQ_TQ
- Request
22 D5 07 - Service 22
DID D507 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Economy mode off state PEUGEOT_ECO_MODE_OFF_ST
- Request
22 D7 24 - Service 22
DID D724 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Electric A/C compressor HV current PEUGEOT_EAC_HV_CURRENT
- Request
22 40 11 - Service 22
DID 4011 - Module
DA42 → 42 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 5)- Range
- 0 to 51 A
- Unit
- A
In testing for 1988 to 1992, 2018 to 2019.
Electric cooling fan control PEUGEOT_GMV_ELEC_COOLING_FAN
- Request
22 D4 2F - Service 22
DID D42F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Electric machine torque PEUGEOT_ELEC_MACHINE_TQ
- Request
22 DC B6 - Service 22
DID DCB6 - Module
6A6 → 686 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 1638.3)- Range
- -1638 to 4915 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Electric machine torque reduction PEUGEOT_ELEC_MACHINE_TQ_REDUCTION
- Request
22 DC 69 - Service 22
DID DC69 - Module
6A6 → 686 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Energy accumulator state transfer PEUGEOT_ENERGY_ACCUMULATOR_ST
- Request
22 D7 55 - Service 22
DID D755 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Energy accumulator temperature limiter state PEUGEOT_ENERGY_ACCUMULATOR_T
- Request
22 D7 58 - Service 22
DID D758 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Engine control module status PEUGEOT_ENG_CTRL_MODULE_STAT
- Request
22 DA DC - Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Engine coolant temperature PEUGEOT_ECT_6A9
- Request
22 D5 55 - Service 22
DID D555 - Module
6A9 → 689 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Engine coolant temperature PEUGEOT_ECT_V2
- Request
22 01 1D - Service 22
DID 011D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Engine oil degradation PEUGEOT_OIL_DEGRAD
- Request
22 38 13 - Service 22
DID 3813 - Module
DA10 → 10 - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 65535)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Engine oil dilution protection status PEUGEOT_ENG_OIL_DILUTION
- Request
22 D5 24 - Service 22
DID D524 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Engine oil pressure PEUGEOT_EOP
- Request
22 02 2A - Service 22
DID 022A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 29 ÷ 50)- Range
- 0 to 147.8999 psi
- Unit
- psi
In testing for 1988 to 1992, 2018 to 2019.
Engine oil temperature PEUGEOT_EOT
Pelican can show this parameter as the engine oil temperature.
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.14)- Range
- -3549.94 to 3003.56 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Engine oil temperature PEUGEOT_EOT_212D
Pelican can show this parameter as the engine oil temperature.
- Request
21 2D - Service 21
PID 2D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 83)- Range
- -83 to 376 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Engine oil temperature PEUGEOT_EOT_21D2
Pelican can show this parameter as the engine oil temperature.
- Request
21 D2 - Service 21
PID D2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Engine oil temperature PEUGEOT_EOT_V2
- Request
21 2D - Service 21
PID 2D - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Engine operating mode PEUGEOT_ENG_OP_MODE
- Request
22 D5 53 - Service 22
DID D553 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 8)- Range
- 0 to 8191 rpm
- Unit
- rpm
In testing for 1988 to 1992, 2018 to 2019.
Engine operational status PEUGEOT_ENGINE_STATUS
- Request
22 10 02 - Service 22
DID 1002 - Module
DA10 → 10 - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Engine restart counter PEUGEOT_ENG_RESTART_CNT
- Request
22 D4 06 - Service 22
DID D406 - Module
6A9 → 689 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Engine restart counter by stop and start function PEUGEOT_ENG_RESTART_CNT_STOP
- Request
22 D7 1B - Service 22
DID D71B - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Engine restart request sent by ESP computer PEUGEOT_ENG_RESTART_REQ_SENT
- Request
22 D7 0D - Service 22
DID D70D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Engine RPM PEUGEOT_RPM_V2
- Request
22 10 00 - Service 22
DID 1000 - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383 rpm
- Unit
- rpm
In testing for 1988 to 1992, 2018 to 2019.
Engine stalls PEUGEOT_ENG_STALLS
- Request
22 D7 30 - Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Engine start prohibition control, start lock PEUGEOT_ENG_START
- Request
22 D7 03 - Service 22
DID D703 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Engine stop time PEUGEOT_ENG_STOP_TIME
- Request
22 D4 77 - Service 22
DID D477 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 s
- Unit
- s
In testing for 1988 to 1992, 2018 to 2019.
Engine temperature PEUGEOT_ENG_TEMEPRATURE
- Request
22 01 98 - Service 22
DID 0198 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Engine torque PEUGEOT_ENG_TQ
- Request
21 C3 - Service 21
PID C3 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Estimated soot removal time PEUGEOT_ESITMATED_SOOT
- Request
21 57 - Service 21
PID 57 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 s
- Unit
- s
In testing for 1988 to 1992, 2018 to 2019.
Estimated torque of internal friction of the engine PEUGEOT_ESTIMATED_TQ
- Request
22 D4 E2 - Service 22
DID D4E2 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Evaluation of carbon content in engine oil PEUGEOT_EVALUATION_CARBON
- Request
22 D5 23 - Service 22
DID D523 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 32)- Range
- 0 to 7.96 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Evaluation of the degree of dilution of motor oil PEUGEOT_EVALUATION_DEGREE
- Request
22 D5 1F - Service 22
DID D51F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Evaluation of the exhaust gas flow using the nox sensor PEUGEOT_EVALUATION_EXH_GAS
- Request
22 D5 42 - Service 22
DID D542 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val × 100)- Range
- -214748364800 to 214748364700 L
- Unit
- L
In testing for 1988 to 1992, 2018 to 2019.
Exhaust camshaft 1 to crankshaft offset PEUGEOT_EXH_CAM_1_OFFSET
- Request
22 06 1B - Service 22
DID 061B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas flow through the particulate filter PEUGEOT_EXH_GAS_FLOW_THROUGH
- Request
22 D5 33 - Service 22
DID D533 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 219.726593)- Range
- 0 to 14399782 L
- Unit
- L
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas pressure at the outlet of the particulate filter PEUGEOT_EXH_GAS_P_OUTLET_PF
- Request
22 D5 44 - Service 22
DID D544 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 999.9999525)- Range
- -32.76 to 32.76 bar
- Unit
- bar
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas recirculation airflow control valve position PEUGEOT_EGR_AIRFLOW_CTRL_VLV
- Request
21 D7 - Service 21
PID D7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val × 39 ÷ 5000)- Range
- 0 to 511 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas recirculation cooler downstream temperature PEUGEOT_EGR_COOLER_T
- Request
22 39 17 - Service 22
DID 3917 - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 100 − 40)- Range
- -40 to 900 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas recirculation flow PEUGEOT_EGR_FLOW
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 kg/h
- Unit
- kg/h
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas recirculation high limit electronic loading PEUGEOT_EGR_HIGH_LIM
- Request
22 D5 53 - Service 22
DID D553 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas recirculation low limit electronic loading PEUGEOT_EGR_LOW_LIM
- Request
22 D5 52 - Service 22
DID D552 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas recirculation orifice temperature PEUGEOT_EGR_ORIFICE_T
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val × 9 ÷ 20 + 32)- Range
- 0 to 29522 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas recirculation temperature PEUGEOT_EGR_T
- Request
22 A0 DC - Service 22
DID A0DC - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 9 ÷ 640)- Range
- 0 to 921 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas recirculation valve duty cycle PEUGEOT_EGR_VLV_CTRL_SIG_RCO
- Request
22 D5 11 - Service 22
DID D511 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas recirculation valve first electronic loading PEUGEOT_EGR_VLV_FIRST
- Request
22 D5 3A - Service 22
DID D53A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas recirculation valve position PEUGEOT_EGR_VLV_POS
- Request
22 D5 09 - Service 22
DID D509 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas recirculation valve position PEUGEOT_EGR_VLV_POS_V2
- Request
22 A0 DA - Service 22
DID A0DA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas recirculation valve set position PEUGEOT_EGR_VLV_SET_POS
- Request
22 D5 10 - Service 22
DID D510 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas recirculation valve, commanded position PEUGEOT_EGR_VLV_CMD_POSTIION
- Request
21 D9 - Service 21
PID D9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128 + 32)- Range
- 0 to 543 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas temperature 1 PEUGEOT_EXH_GAS_T_1
- Request
21 D6 - Service 21
PID D6 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 144 ÷ 5 + 32)- Range
- 0 to 7376 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas temperature 1 PEUGEOT_EXH_GAS_T_1_7E0
- Request
21 48 - Service 21
PID 48 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas temperature 1 – DOC inlet PEUGEOT_EXH_GAS_T_1_DOC
- Request
22 A0 BD - Service 22
DID A0BD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val + 32)- Range
- -32736 to 32799 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas temperature 2 PEUGEOT_EXH_GAS_T_2
- Request
21 D6 - Service 21
PID D6 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 9 ÷ 80 + 32)- Range
- 0 to 7404 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas temperature 2 PEUGEOT_EXH_GAS_T_2_7E0
- Request
21 48 - Service 21
PID 48 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas temperature 2 – DOC outlet PEUGEOT_EXH_GAS_T_2_DOC
- Request
22 A0 C2 - Service 22
DID A0C2 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val + 32)- Range
- -32736 to 32799 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas temperature 3 PEUGEOT_EXH_GAS_T_3
- Request
21 D6 - Service 21
PID D6 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val × 9 ÷ 80 + 32)- Range
- 0 to 7404 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas temperature 3 – DPF outlet PEUGEOT_EXH_GAS_T_3_DPF
- Request
22 A0 C4 - Service 22
DID A0C4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val + 32)- Range
- -32736 to 32799 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas temperature 4 PEUGEOT_EXH_GAS_T_4
- Request
21 D6 - Service 21
PID D6 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val × 9 ÷ 80 + 32)- Range
- 0 to 7404 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas temperature 4, catalyst middle PEUGEOT_EXH_GAS_T_4_SCR_CAT
- Request
22 A0 C6 - Service 22
DID A0C6 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val + 32)- Range
- -32736 to 32799 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Exhaust gas temperature 5 – SCR CAT outlet PEUGEOT_EXH_GAS_T_5_SCR_CAT
- Request
22 A0 C8 - Service 22
DID A0C8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val + 32)- Range
- -32736 to 32799 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Exhaust temperature, downstream of exhaust manifold PEUGEOT_EXH_T_DN_EXH
- Request
22 01 7E - Service 22
DID 017E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.14)- Range
- -3549.94 to 3003.56 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Exhaust temperature, EGR cooler downstream PEUGEOT_EXH_T_EGR_COOLER_DN
- Request
22 01 7E - Service 22
DID 017E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.14)- Range
- -3549.94 to 3003.56 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Exhaust temperature, upstream of exhaust manifold PEUGEOT_EXH_T_UP_EXH
- Request
22 01 7E - Service 22
DID 017E - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.14)- Range
- -3549.94 to 3003.56 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Expected generator supplier identifier of the reversible generator PEUGEOT_EXPECTED_GEN
- Request
22 D7 89 - Service 22
DID D789 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Expected identifier of electronic power circuit of reversible generator generator PEUGEOT_EXPECTED_IDENTIFIER_ELECTRONIC
- Request
22 D7 88 - Service 22
DID D788 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Expected identifier of reversible generator PEUGEOT_EXPECTED_IDENTIFIER
- Request
22 D7 87 - Service 22
DID D787 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Fuel correction cylinder 1 PEUGEOT_FUEL_CORR_CYL1
- Request
22 38 00 - Service 22
DID 3800 - Module
DA10 → 10 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -5 to 5 mg/stroke
- Unit
- mg/stroke
In testing for 1988 to 1992, 2018 to 2019.
Fuel correction cylinder 2 PEUGEOT_FUEL_CORR_CYL2
- Request
22 38 01 - Service 22
DID 3801 - Module
DA10 → 10 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -5 to 5 mg/stroke
- Unit
- mg/stroke
In testing for 1988 to 1992, 2018 to 2019.
Fuel correction cylinder 3 PEUGEOT_FUEL_CORR_CYL3
- Request
22 38 02 - Service 22
DID 3802 - Module
DA10 → 10 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -5 to 5 mg/stroke
- Unit
- mg/stroke
In testing for 1988 to 1992, 2018 to 2019.
Fuel correction cylinder 4 PEUGEOT_FUEL_CORR_CYL4
- Request
22 38 03 - Service 22
DID 3803 - Module
DA10 → 10 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -5 to 5 mg/stroke
- Unit
- mg/stroke
In testing for 1988 to 1992, 2018 to 2019.
Fuel rail pressure commanded PEUGEOT_RAIL_PRESS_CMD
- Request
22 19 46 - Service 22
DID 1946 - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3000 bar
- Unit
- bar
In testing for 1988 to 1992, 2018 to 2019.
Fuel rail pressure measured PEUGEOT_RAIL_PRESS
- Request
22 19 47 - Service 22
DID 1947 - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3000 bar
- Unit
- bar
In testing for 1988 to 1992, 2018 to 2019.
FUGITIVE TRIP IN EMERGENCY MODE PEUGEOT_FUGITIVE_TRIP
- Request
22 D6 71 - Service 22
DID D671 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Generator mode PEUGEOT_GEN_MODE
- Request
22 D7 14 - Service 22
DID D714 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 75)- Range
- 0 to 19125 rpm
- Unit
- rpm
In testing for 1988 to 1992, 2018 to 2019.
Generator shutdown PEUGEOT_GEN_SHUTDOWN
- Request
22 D7 5B - Service 22
DID D75B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Glow plug plug set temperature PEUGEOT_PREHEATING_T
- Request
22 D5 0F - Service 22
DID D50F - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Glow plug relay status PEUGEOT_STAT_PRE_POST
- Request
22 D5 0D - Service 22
DID D50D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
IAT post-intercooler PEUGEOT_IAT_TURBO
- Request
22 19 35 - Service 22
DID 1935 - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 100 − 40)- Range
- -40 to 200 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Identifier of the electronic power circuit of the reversible generator PEUGEOT_IDENTIFIER
- Request
22 D7 32 - Service 22
DID D732 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Identifier of the supplier of the reversible generator PEUGEOT_IDENTIFIER_SUPPLIER
- Request
22 D7 33 - Service 22
DID D733 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Immobilizer code programming status PEUGEOT_IMMOBILIZER_CODE
- Request
22 DA DC - Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Indicated engine torque PEUGEOT_INDICATED_ENG_TQ
- Request
22 D4 D2 - Service 22
DID D4D2 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16)- Range
- 0 to 4095 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Injection pulse, cylinder 1 PEUGEOT_INJ_CYL_1
- Request
22 02 34 - Service 22
DID 0234 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Injection pulse, cylinder 2 PEUGEOT_INJ_CYL_2
- Request
22 02 35 - Service 22
DID 0235 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Injection pulse, cylinder 3 PEUGEOT_INJ_CYL_3
- Request
22 02 36 - Service 22
DID 0236 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Injection pulse, cylinder 4 PEUGEOT_INJ_CYL_4
- Request
22 02 37 - Service 22
DID 0237 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Injector code 1 PEUGEOT_INJ_CODE_1
- Request
22 D5 00 - Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 8 to 47 of the reply, 40 bits.
- Formula
val- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Injector code 2 PEUGEOT_INJ_CODE_2
- Request
22 D5 00 - Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 72 to 111 of the reply, 40 bits.
- Formula
val- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Injector code 3 PEUGEOT_INJ_CODE_3
- Request
22 D5 00 - Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 136 to 175 of the reply, 40 bits.
- Formula
val- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Injector code 4 PEUGEOT_INJ_CODE_4
- Request
22 D5 00 - Service 22
DID D500 - Module
6A8 → 688 - Every
1 s - Testing
Bits 200 to 239 of the reply, 40 bits.
- Formula
val- Range
- 0 to 1099511627775
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Injector pulse width, cylinder 1 PEUGEOT_INJ_WIDTH_CYL_1
- Request
22 02 34 - Service 22
DID 0234 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 1988 to 1992, 2018 to 2019.
Injector pulse width, cylinder 2 PEUGEOT_INJ_WIDTH_CYL_2
- Request
22 02 35 - Service 22
DID 0235 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 1988 to 1992, 2018 to 2019.
Injector pulse width, cylinder 3 PEUGEOT_INJ_WIDTH_CYL_3
- Request
22 02 36 - Service 22
DID 0236 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 1988 to 1992, 2018 to 2019.
Injector pulse width, cylinder 4 PEUGEOT_INJ_WIDTH_CYL_4
- Request
22 02 37 - Service 22
DID 0237 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 ms
- Unit
- ms
In testing for 1988 to 1992, 2018 to 2019.
Intake camshaft 1 to crankshaft offset PEUGEOT_INT_CAM_1_OFFSET
- Request
22 06 C2 - Service 22
DID 06C2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °
- Unit
- °
In testing for 1988 to 1992, 2018 to 2019.
Intake manifold air pressure PEUGEOT_MAP
- Request
22 01 74 - Service 22
DID 0174 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kPa
- Unit
- kPa
In testing for 1988 to 1992, 2018 to 2019.
Intake manifold air temperature PEUGEOT_IAT_01FF
- Request
22 01 FF - Service 22
DID 01FF - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Intake manifold air temperature PEUGEOT_IAT_70B8
- Request
22 70 B8 - Service 22
DID 70B8 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0198412698 − 40)- Range
- -40 to 1260.2976 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Intake manifold air temperature PEUGEOT_INT_MANIFOLD_AIR_T
- Request
22 19 35 - Service 22
DID 1935 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val − 40)- Range
- -40 to 65495 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Inverter temperature estimated PEUGEOT_INVERTER_T_ESTIMATED
- Request
22 DC 6A - Service 22
DID DC6A - Module
6A6 → 686 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Inverter temperature, commanded PEUGEOT_INVERTER_T_CMD
- Request
22 DC 04 - Service 22
DID DC04 - Module
6A6 → 686 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Knock sensor 1 PEUGEOT_KNOCK_SENS_1
- Request
22 01 A9 - Service 22
DID 01A9 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 1992, 2018 to 2019.
Knock sensor 2 PEUGEOT_KNOCK_SENS_2
- Request
22 01 AA - Service 22
DID 01AA - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 5 V
- Unit
- V
In testing for 1988 to 1992, 2018 to 2019.
Line pressure PEUGEOT_LINE_P
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 psi
- Unit
- psi
In testing for 1988 to 1992, 2018 to 2019.
Line pressure duty cycle PEUGEOT_LINE_P_DUTY
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 655)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Line pressure solenoid valve control current PEUGEOT_SLT_LINE_P_VARIATION
- Request
22 D6 06 - Service 22
DID D606 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 1992, 2018 to 2019.
Lock status PEUGEOT_LOCK_STAT
- Request
22 DA DD - Service 22
DID DADD - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Long-term regeneration capability PEUGEOT_LONG_TERM_REGEN
- Request
22 D5 4D - Service 22
DID D54D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Low side coolant temperature PEUGEOT_LOW_SIDE_ECT
- Request
22 12 C9 - Service 22
DID 12C9 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
M-Prop injection command PEUGEOT_MPROP_CMD
- Request
22 18 D0 - Service 22
DID 18D0 - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Mass airflow sensor temperature PEUGEOT_MAF_TEMP
- Request
22 19 3F - Service 22
DID 193F - Module
DA10 → 10 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 100 − 40)- Range
- -40 to 200 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Mass of urea injected for thermal protection of urea injector PEUGEOT_MASS_UREA_INJECTED
- Request
22 D5 6B - Service 22
DID D56B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50.00000112)- Range
- 0 to 1310 g
- Unit
- g
In testing for 1988 to 1992, 2018 to 2019.
Maximum allowable torque PEUGEOT_MAX_ALLOWABLE_TQ
- Request
22 D5 06 - Service 22
DID D506 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Measured current of electromagnetic valve for changing the pressure in the brake system B2 PEUGEOT_MEAS_CURRENT_P_B2
- Request
22 D6 23 - Service 22
DID D623 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 1992, 2018 to 2019.
Measured current of the electromagnetic valve for changing the pressure in the brake system B1 PEUGEOT_MEAS_CURRENT_P_B1
- Request
22 D6 09 - Service 22
DID D609 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 1992, 2018 to 2019.
Measured line pressure variation solenoid valve current PEUGEOT_MEAS_LINE_P
- Request
22 D6 07 - Service 22
DID D607 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 mA
- Unit
- mA
In testing for 1988 to 1992, 2018 to 2019.
Mileage remaining before diesel particulate filter replacement PEUGEOT_MILEAGE_REMAINING
- Request
22 D5 30 - Service 22
DID D530 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 16)- Range
- -524288 to 524272 km
- Unit
- km
In testing for 1988 to 1992, 2018 to 2019.
Mileage since last diesel particulate filter replacement PEUGEOT_MILEAGE_SINCE_DPF
- Request
22 D5 31 - Service 22
DID D531 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8)- Range
- 0 to 524280 km
- Unit
- km
In testing for 1988 to 1992, 2018 to 2019.
Mileage since last oil change PEUGEOT_MILEAGE_SINCE_OIL
- Request
22 D4 3F - Service 22
DID D43F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
In testing for 1988 to 1992, 2018 to 2019.
Minimum cell capacity PEUGEOT_MIN_CELL_CAP
- Request
22 D4 13 - Service 22
DID D413 - Module
6B4 → 694 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Mixture enrichment measured by nox sensor at inlet PEUGEOT_MIXTURE_ENRICHMENT
- Request
22 D5 71 - Service 22
DID D571 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Mixture enrichment measured by nox sensor at outlet PEUGEOT_MIXTURE_ENRICHMENT_MEAS
- Request
22 D5 5B - Service 22
DID D55B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Movement of controlled air supply module PEUGEOT_MOVEMENT_CONTROLLED
- Request
22 D4 EB - Service 22
DID D4EB - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Multi-displacement system active PEUGEOT_MDS_ACTIVE
- Request
22 0E CA - Service 22
DID 0ECA - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 1992, 2018 to 2019.
Neutral position sensor status PEUGEOT_NEUTRAL_POS_SENS
- Request
22 D4 38 - Service 22
DID D438 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Nitrogen oxides at exhaust treatment intake PEUGEOT_AFTERTREATMENT_INT
- Request
22 A1 14 - Service 22
DID A114 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Nitrogen oxides at exhaust treatment outlet PEUGEOT_AFTERTREATMENT
- Request
22 A1 1A - Service 22
DID A11A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Nox sensor heating control PEUGEOT_NOX_SENS_HEATING
- Request
22 D5 54 - Service 22
DID D554 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Nox sensor signal status at the inlet PEUGEOT_NOX_SENS_SIG_STAT_INLET
- Request
22 D5 72 - Service 22
DID D572 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Nox sensor signal status at the outlet PEUGEOT_NOX_SENS_SIG_STAT
- Request
22 D5 73 - Service 22
DID D573 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Nox system operating status PEUGEOT_NOX_SYSTEM_OP_STAT
- Request
22 D5 40 - Service 22
DID D540 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Number of engine stop information deletion cycles PEUGEOT_NUM_ENG_STOP
- Request
22 D7 30 - Service 22
DID D730 - Module
6A9 → 689 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Oil pressure PEUGEOT_OIL_P
- Request
22 D4 29 - Service 22
DID D429 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 1988 to 1992, 2018 to 2019.
Oil pressure reference value PEUGEOT_OIL_P_REFERENCE
- Request
22 D4 64 - Service 22
DID D464 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 bar
- Unit
- bar
In testing for 1988 to 1992, 2018 to 2019.
Oil pressure regulation control PEUGEOT_OIL_P_REGULATION
- Request
22 D4 3B - Service 22
DID D43B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Oil temperature PEUGEOT_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Request
22 D4 7D - Service 22
DID D47D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 273.1400146)- Range
- -3549 to 3003 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Oil temperature PEUGEOT_OIL_TEMEPRATURE
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273 to 6280 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Open loop soot load assessment of the diesel particulate filter PEUGEOT_OPEN_LOOP_SOOT_LOAD
- Request
22 D5 4A - Service 22
DID D54A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1024)- Range
- 0 to 63.99 g/L
- Unit
- g/L
In testing for 1988 to 1992, 2018 to 2019.
Outside air temperature PEUGEOT_AAT_6A8
- Request
22 D4 14 - Service 22
DID D414 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Particulate filter differential pressure PEUGEOT_PF_DIFF_P
- Request
22 D5 20 - Service 22
DID D520 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Particulate filter regeneration count PEUGEOT_DPF_REGENS_5089
- Request
22 50 89 - Service 22
DID 5089 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Power consumed for heating the pipelines of the urea injection system PEUGEOT_POWER_CONSUMED
- Request
22 D5 80 - Service 22
DID D580 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Power spent on heating the urea injection system pipes, percentage ratio PEUGEOT_POWER_SPENT_ON
- Request
22 D5 3C - Service 22
DID D53C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 163.8399875)- Range
- 0 to 399 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Powertrain condition PEUGEOT_POWERTRAIN_COND
- Request
22 D4 BA - Service 22
DID D4BA - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Preheating relay control PEUGEOT_PREHEATING_RELAY
- Request
22 D5 0C - Service 22
DID D50C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100.0000022)- Range
- -327 to 327 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Presence of the identifier of the reversible generator PEUGEOT_PRESENCE_IDENTIFIER
- Request
22 D7 31 - Service 22
DID D731 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Pressure in the particulate filter PEUGEOT_P_PF
- Request
22 01 7B - Service 22
DID 017B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Pressure-based injection permission for urea solution PEUGEOT_P_BASED_INJ
- Request
22 D5 14 - Service 22
DID D514 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Problems detected while transmitting unlock code PEUGEOT_PROBLEMS_DETECTED
- Request
22 DA DC - Service 22
DID DADC - Module
6A8 → 688 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Problems detected while transmitting unlock code PEUGEOT_PROBLEMS_DETECTED_WHILE
- Request
22 DA DC - Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Real engine torque PEUGEOT_REAL_ENG_TQ
- Request
22 D5 54 - Service 22
DID D554 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2 − 100)- Range
- -100 to 410 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Regen enable, on/off – alternative PEUGEOT_REGEN_ENABLE_ON_OFF
- Request
21 D8 - Service 21
PID D8 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 95 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 1992, 2018 to 2019.
Regeneration active PEUGEOT_DPF_REGEN_ACTIVE
- Request
22 50 AF - Service 22
DID 50AF - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Regeneration enable PEUGEOT_REGEN_ENABLE
- Request
22 D5 28 - Service 22
DID D528 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Remaining urea solution in the urea tank PEUGEOT_REMAINING_UREA
- Request
22 D5 17 - Service 22
DID D517 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 125 ÷ 128)- Range
- 0 to 63999
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Remote wake-up circuit status PEUGEOT_REMOTE_WAKE_UP
- Request
22 D7 05 - Service 22
DID D705 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Remote wake-up state PEUGEOT_REMOTE_WAKE_UP_ST
- Request
22 D7 08 - Service 22
DID D708 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Request to turn on the engine diagnostic indicator PEUGEOT_REQ_TURN_ON_ENG
- Request
22 D5 11 - Service 22
DID D511 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Requested value controlled thermostat PEUGEOT_REQ_CONTROLLED
- Request
22 D5 86 - Service 22
DID D586 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 81.92000625)- Range
- -399 to 399 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Restart request sent by power steering computer PEUGEOT_RESTART_REQ_SENT
- Request
22 D7 0C - Service 22
DID D70C - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Restart request sent by suspension computer PEUGEOT_RESTART_REQ_SENT_SUSPENSION
- Request
22 D7 0E - Service 22
DID D70E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Return to engine start and restart control by starter PEUGEOT_RETURN_ENG_START
- Request
22 D7 64 - Service 22
DID D764 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Return to starter engine restart control PEUGEOT_RETURN_STARTER_ENG
- Request
22 D7 61 - Service 22
DID D761 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Reverse generator status PEUGEOT_REVERSE_GEN_STAT
- Request
22 D7 16 - Service 22
DID D716 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Reversible generator torque PEUGEOT_REVERSIBLE_GEN_TQ
- Request
22 D7 15 - Service 22
DID D715 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Sensed oil pressure PEUGEOT_SENSED_OIL_P
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Sensed pressure particulate filter downstream PEUGEOT_SENSED_P_PF_DN
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Service network related engine restart request PEUGEOT_SERVICE_NETWORK
- Request
22 D7 4B - Service 22
DID D74B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Short term knock retard PEUGEOT_SHORT_TERM_KNOCK
- Request
22 01 AE - Service 22
DID 01AE - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 °
- Unit
- °
In testing for 1988 to 1992, 2018 to 2019.
Short-term regeneration capability PEUGEOT_SHORT_TERM_REGEN
- Request
22 D5 4C - Service 22
DID D54C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Simulated particulate mass, stored PEUGEOT_DPF_SIM_MASS
- Request
22 01 E2 - Service 22
DID 01E2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Soot clogging level of diesel particulate filter PEUGEOT_SOOT_CLOGGING_LEVEL
- Request
22 D5 2F - Service 22
DID D52F - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10.24)- Range
- 0 to 6399 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Soot load PEUGEOT_SOOT_LOAD
- Request
21 4D - Service 21
PID 4D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 g
- Unit
- g
In testing for 1988 to 1992, 2018 to 2019.
Soot load based on delta pressure PEUGEOT_SOOT_LOAD_BASED_ON_P
- Request
21 57 - Service 21
PID 57 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 100 + 32)- Range
- 0 to 34.55
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Soot mass flow in exhaust gas after combustion PEUGEOT_SOOT_MASS_FLOW_EXH
- Request
22 01 7A - Service 22
DID 017A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 223 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -21474836 to 21474836
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Soot mass load PEUGEOT_SOOT_MASS_LOAD
- Request
22 50 8D - Service 22
DID 508D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 650)- Range
- 0 to 100.823 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Specified volume of injected urea solution PEUGEOT_SPEC_VOLUME_INJECTED
- Request
22 D5 50 - Service 22
DID D550 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Sport mode contactor state PEUGEOT_SPORT_MODE_CONTACTOR
- Request
22 D5 03 - Service 22
DID D503 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Start inhibit control, wired PEUGEOT_START_INHIBIT_CTRL
- Request
22 D7 67 - Service 22
DID D767 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Start or restart inhibition transmitted by engine management computer PEUGEOT_START_OR_RESTART
- Request
22 D7 1E - Service 22
DID D71E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Start prohibition PEUGEOT_START_PROHIBITION
- Request
22 D5 1B - Service 22
DID D51B - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Starter activation counter PEUGEOT_STARTER_ACTIVATION
- Request
22 D7 1F - Service 22
DID D71F - Module
6A8 → 688 - Every
3600 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Starter control interface unit operating status PEUGEOT_STARTER_CTRL
- Request
22 D7 2A - Service 22
DID D72A - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Starter duty cycle PEUGEOT_STARTER_DUTY
- Request
22 D4 78 - Service 22
DID D478 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 s
- Unit
- s
In testing for 1988 to 1992, 2018 to 2019.
Starter engagement status PEUGEOT_STARTER_ENGAGEMENT
- Request
22 D4 C3 - Service 22
DID D4C3 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
State lock/unlock control unit PEUGEOT_ST_LOCK_UNLOCK_CTRL
- Request
22 DA DC - Service 22
DID DADC - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Status of internal ignition motor PEUGEOT_STAT_INTERNAL_IGN
- Request
22 D4 12 - Service 22
DID D412 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Status of the energy accumulator PEUGEOT_STAT_ENERGY
- Request
22 D7 22 - Service 22
DID D722 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Stop allowed by ESP computer PEUGEOT_STOP_ALLOWED_ESP
- Request
22 D7 06 - Service 22
DID D706 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Stop and start function state PEUGEOT_STOP_START_FUNCTION
- Request
22 D7 25 - Service 22
DID D725 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Stop and start switch PEUGEOT_STOP_START_SWITCH
- Request
22 D7 26 - Service 22
DID D726 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Stop permitted by suspension computer PEUGEOT_STOP_PERMITTED
- Request
22 D7 07 - Service 22
DID D707 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Swirl actuator command PEUGEOT_SWIRL_CMD
- Request
22 18 9B - Service 22
DID 189B - Module
DA10 → 10 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327.68)- Range
- -100 to 100 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Temperature before catalyst PEUGEOT_T_BEFORE_CAT
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273.14 to 6280.36 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Temperature before diesel particulate filter PEUGEOT_T_BEFORE_DPF
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273.14 to 6280.36 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Temperature before turbine PEUGEOT_T_BEFORE_TURBINE
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273.14 to 6280.36 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Temperature difference between the hottest and the coolest cells PEUGEOT_T_DIFF_HOTEST
- Request
22 D8 78 - Service 22
DID D878 - Module
6B4 → 694 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Temperature of the energy accumulator PEUGEOT_T_ENERGY_ACCUMULATOR
- Request
22 D7 21 - Service 22
DID D721 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Temperature of the urea solution in the urea tank PEUGEOT_T_UREA_SOLUTION_UREA
- Request
22 D5 6D - Service 22
DID D56D - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
The composition of the mixture is calculated by the oxygen sensor PEUGEOT_COMPOSITION_MIXTURE
- Request
22 D5 70 - Service 22
DID D570 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32786.88588)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Throttle inlet air temperature filtered PEUGEOT_THROTTLE_INLET_AIR_T
- Request
22 14 B1 - Service 22
DID 14B1 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Throttle inlet air temperature raw PEUGEOT_THROTTLE_INLET_AIR_T_RAW
- Request
22 14 B3 - Service 22
DID 14B3 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Throttle inlet pressure PEUGEOT_THROTTLE_INLET_P
- Request
22 12 47 - Service 22
DID 1247 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 160)- Range
- 0 to 409.5937 kPa
- Unit
- kPa
In testing for 1988 to 1992, 2018 to 2019.
Time since active regen PEUGEOT_TIME_SINCE_ACTIVE
- Request
22 A0 03 - Service 22
DID A003 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 h
- Unit
- h
In testing for 1988 to 1992, 2018 to 2019.
Time since regen started PEUGEOT_TIME_SINCE_REGEN
- Request
21 D6 - Service 21
PID D6 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 40)- Range
- 0 to 1638 s
- Unit
- s
In testing for 1988 to 1992, 2018 to 2019.
Torque corresponding to driver requirement PEUGEOT_TQ_CORRESPONDING
- Request
22 D4 E3 - Service 22
DID D4E3 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Torque supplied or taken by generator PEUGEOT_TQ_SUPPLIED_OR_TAKEN
- Request
22 D7 28 - Service 22
DID D728 - Module
6A8 → 688 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047 N·m
- Unit
- N·m
In testing for 1988 to 1992, 2018 to 2019.
Total mass of additive accumulated in the diesel particulate filter PEUGEOT_TOT_MASS_ADDITIVE
- Request
22 D5 26 - Service 22
DID D526 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- 0 to 511 g
- Unit
- g
In testing for 1988 to 1992, 2018 to 2019.
Total mass of additive accumulated in the diesel particulate filter PEUGEOT_TOT_MASS_ADDITIVE_ACCUMULATED_DPF
- Request
22 D5 27 - Service 22
DID D527 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047 g
- Unit
- g
In testing for 1988 to 1992, 2018 to 2019.
Total mileage PEUGEOT_ODO_6A8
Pelican can show this parameter as the odometer.
- Request
22 D4 9C - Service 22
DID D49C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 1988 to 1992, 2018 to 2019.
Total number of started regeneration events PEUGEOT_TOT_NUM_STARTED
- Request
22 18 E7 - Service 22
DID 18E7 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Towing device configured PEUGEOT_CAN_VEH_BE_EQUIPPED
- Request
22 D5 57 - Service 22
DID D557 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Traction circuit coolant temperature PEUGEOT_TRACTION_CIRCUIT_ECT
- Request
22 D8 F9 - Service 22
DID D8F9 - Module
6A2 → 682 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Traction or stability control regulating PEUGEOT_ASR_OR_ESP_SYSTEM
- Request
22 D5 12 - Service 22
DID D512 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Transmission fluid temperature PEUGEOT_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 C5 - Service 21
PID C5 - Module
6A9 → 689 - Every
250 ms - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Turbine upstream temperature PEUGEOT_TURBINE_UP_T
- Request
22 01 68 - Service 22
DID 0168 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273.14)- Range
- -273.14 to 6280.36 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Turbo boost pressure PEUGEOT_BOOST
- Request
22 19 5A - Service 22
DID 195A - Module
DA10 → 10 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 3276.8)- Range
- -100 to 300 kPa
- Unit
- kPa
In testing for 1988 to 1992, 2018 to 2019.
Turbo compressor inlet temperature PEUGEOT_TURBO_COMP_INLET_T
- Request
22 A0 EC - Service 22
DID A0EC - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 36 ÷ 5 + 32)- Range
- 0 to 1868 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Urea mass fraction PEUGEOT_UREA_MASS_FRACTION
- Request
22 D5 8C - Service 22
DID D58C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Urea solution injected amount PEUGEOT_UREA_SOLUTION
- Request
22 D5 68 - Service 22
DID D568 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Urea solution injection permission based on temperature value PEUGEOT_UREA_SOLUTION_INJ_ON_T
- Request
22 D5 15 - Service 22
DID D515 - Module
6A8 → 688 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Urea solution pressure PEUGEOT_UREA_SOLUTION_P
- Request
22 D5 3E - Service 22
DID D53E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 128)- Range
- 0 to 511 bar
- Unit
- bar
In testing for 1988 to 1992, 2018 to 2019.
Urea solution type in urea tank PEUGEOT_UREA_SOLUTION_TYPE
- Request
22 D5 8D - Service 22
DID D58D - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Urea tank heating current PEUGEOT_UREA_TANK_HEATING
- Request
22 D5 81 - Service 22
DID D581 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Urea tank heating current, percentage PEUGEOT_UREA_TANK_HEATING_CURRENT
- Request
22 D5 1E - Service 22
DID D51E - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 163.8399875)- Range
- 0 to 399 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Vacuum circuit vacuum PEUGEOT_VACUUM_CIRCUIT
- Request
22 D7 3B - Service 22
DID D73B - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Raw value
In testing for 1988 to 1992, 2018 to 2019.
Value during generator load smooth increase PEUGEOT_DURING_GEN_LOAD
- Request
22 D7 53 - Service 22
DID D753 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Variable geometry turbo actuator, commanded position PEUGEOT_VGT_CMD_189F
- Request
22 18 9F - Service 22
DID 189F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 39 ÷ 50 − 100)- Range
- -100 to 98.9 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Variable geometry turbo actuator, commanded position PEUGEOT_VGT_CMD_507B
- Request
22 50 7B - Service 22
DID 507B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 39 ÷ 50 − 100)- Range
- -100 to 98.9 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Variable geometry turbo compressor inlet air temperature PEUGEOT_VGT_COMP_INLET_AIR_T
- Request
21 DA - Service 21
PID DA - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val × 9 ÷ 20 + 32)- Range
- 0 to 29522 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Variable geometry turbo compressor outlet air temperature PEUGEOT_VGT_COMP_OULET_AIR_T
- Request
21 DA - Service 21
PID DA - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val × 9 ÷ 20 + 32)- Range
- 0 to 29522 °F
- Unit
- °F
In testing for 1988 to 1992, 2018 to 2019.
Variable oil pump position PEUGEOT_OIL_PUMP
- Request
22 19 4F - Service 22
DID 194F - Module
DA10 → 10 - Every
30 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Variable valve timing oil pressure PEUGEOT_VARIABLE_VLV_TIM_OIL_P
- Request
22 06 9E - Service 22
DID 069E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 kPa
- Unit
- kPa
In testing for 1988 to 1992, 2018 to 2019.
Variable valve timing oil temperature PEUGEOT_VARIABLE_VLV_TIM_OIL_T
- Request
22 06 9F - Service 22
DID 069F - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 64)- Range
- -64 to 191 °C
- Unit
- °C
In testing for 1988 to 1992, 2018 to 2019.
Vehicle hour meter PEUGEOT_VEH_HOUR_METER
- Request
22 D8 01 - Service 22
DID D801 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 s
- Unit
- s
In testing for 1988 to 1992, 2018 to 2019.
Vehicle mileage remaining before filling the tank with urea solution PEUGEOT_VEH_MILEAGE
- Request
22 D5 13 - Service 22
DID D513 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 50)- Range
- 0 to 12750 km
- Unit
- km
In testing for 1988 to 1992, 2018 to 2019.
Vehicle mileage since the last oil change under severe vehicle operating conditions PEUGEOT_VEH_MILEAGE_SINCE
- Request
22 D5 34 - Service 22
DID D534 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 km
- Unit
- km
In testing for 1988 to 1992, 2018 to 2019.
VGT position actual PEUGEOT_VGT_ACT
- Request
22 18 A0 - Service 22
DID 18A0 - Module
DA10 → 10 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 65535)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
VGT position commanded PEUGEOT_VGT_CMD
- Request
22 18 9F - Service 22
DID 189F - Module
DA10 → 10 - Every
2 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 65535)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1992, 2018 to 2019.
Volume of urea solution measured in urea tank PEUGEOT_VOLUME_UREA_SOLUTION
- Request
22 D5 58 - Service 22
DID D558 - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 L
- Unit
- L
In testing for 1988 to 1992, 2018 to 2019.
Wastegate position sensor PEUGEOT_WASTEGATE_POS_SENS
- Request
22 1F 59 - Service 22
DID 1F59 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 61 ÷ 12500)- Range
- 0 to 319.8107 V
- Unit
- V
In testing for 1988 to 1992, 2018 to 2019.
Water in diesel PEUGEOT_WATER_DIESEL
- Request
22 D5 2C - Service 22
DID D52C - Module
6A8 → 688 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.
Winter mode switch state PEUGEOT_WINTER_MODE_SWITCH
- Request
22 D5 02 - Service 22
DID D502 - Module
6A9 → 689 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1992, 2018 to 2019.