Peugeot 107

Door parameters

The Peugeot 107 has 5 door parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Driver door open PEUGEOT_DRIVER_DOOR_OPEN

  • Request22 03 02
  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2005 to 2008, 2010 to 2014. Not supported for 2009.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Driver door open PEUGEOT_DRIVER_DOOR_OPEN

  • Request22 03 02
  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2005 to 2008, 2010 to 2014. Not supported for 2009.

Passenger door open PEUGEOT_PASSENGER_DOOR_OPEN

  • Request22 03 02
  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2005 to 2008, 2010 to 2014. Not supported for 2009.

Rear left door open PEUGEOT_RLD_OPEN

  • Request22 03 02
  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2005 to 2008, 2010 to 2014. Not supported for 2009.

Rear right door open PEUGEOT_RRD_OPEN

  • Request22 03 02
  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2005 to 2008, 2010 to 2014. Not supported for 2009.

Trunk open PEUGEOT_TRUNK_OPEN

  • Request22 03 02
  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2005 to 2008, 2010 to 2014. Not supported for 2009.