Nissan LEAF

Battery parameters

The Nissan LEAF has 124 battery parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

12V battery voltage LEAF_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 11 03
  • Service 22DID 1103
  • Module797 → 79A
  • Every1 s
  • Testing for 2014, 2016, 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 0 to 7 of the reply, 8 bits.

0x9C = 156 → (156 ÷ 12.5) = 12.48 V

Formula
(val ÷ 12.5)
Range
0 to 30 V
Unit
V

Confirmed for 2013, 2015, 2017 to 2019, 2021 to 2022, 2024. In testing for 2014, 2016, 2020, 2023, 2025 to 2026. Not supported for 2012.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

12V battery current LEAF_12V_CURRConfirmed

  • Request22 11 83
  • Service 22DID 1183
  • Module797 → 79A
  • Every1 s
  • Testing for 2014, 2016, 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x028E = 654 → (654 ÷ 256) = 2.554688 A

Formula
(val ÷ 256)
Range
-128 to 128 A
Unit
A

Confirmed for 2013, 2015, 2017 to 2019, 2021 to 2022, 2024. In testing for 2014, 2016, 2020, 2023, 2025 to 2026. Not supported for 2012.

12V battery voltage LEAF_VPWRConfirmed

Pelican can show this parameter as the starter battery voltage.

  • Request22 11 03
  • Service 22DID 1103
  • Module797 → 79A
  • Every1 s
  • Testing for 2014, 2016, 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 0 to 7 of the reply, 8 bits.

0x9C = 156 → (156 ÷ 12.5) = 12.48 V

Formula
(val ÷ 12.5)
Range
0 to 30 V
Unit
V

Confirmed for 2013, 2015, 2017 to 2019, 2021 to 2022, 2024. In testing for 2014, 2016, 2020, 2023, 2025 to 2026. Not supported for 2012.

Charging mode LEAF_CHARGE_MODEConfirmed

Pelican can show this parameter as the charging state.

  • Request22 11 4E
  • Service 22DID 114E
  • Module797 → 79A
  • Every1 s
  • Testing for 2014, 2016, 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → NOT_CHARGING

Unit
Named states
States
Raw valueStateMeaning
0NOT_CHARGINGNot charging
1CHARGING_L1L1 charging (100-120V)
2CHARGING_L2L2 charging (200-240V)
3CHARGING_L3L3 quick charging

Confirmed for 2013, 2015, 2017 to 2019, 2021 to 2022, 2024. In testing for 2014, 2016, 2020, 2023, 2025 to 2026. Not supported for 2012.

Charging power LEAF_CHRG_PWRConfirmed

Power entering the high voltage battery while charging.

  • Request22 12 36
  • Service 22DID 1236
  • Module797 → 79A
  • Every1 s
  • Testing for 2014, 2016, 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 100) = 0 W

Formula
(val × 100)
Range
0 to 6553500 W
Unit
W

Confirmed for 2013, 2015, 2017 to 2019, 2021 to 2022, 2024. In testing for 2014, 2016, 2020, 2023, 2025 to 2026. Not supported for 2012.

High voltage battery capacity LEAF_HVBAT_CAPConfirmed

  • Request21 01
  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing for 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 280 to 303 of the reply, 24 bits.

0x106861 = 1075297 → (1075297 ÷ 10000) = 107.5297 Ah

Formula
(val ÷ 10000)
Range
0 to 1000 Ah
Unit
Ah

Confirmed for 2018 to 2019, 2021 to 2022, 2024. In testing for 2020, 2023, 2025 to 2026.

High voltage battery capacity LEAF_HVBAT_CAP_PRE18Confirmed

  • Request21 01
  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing for 2010 to 2011, 2014, 2016

Example reply from a 2017 Nissan LEAF.

Bits 264 to 287 of the reply, 24 bits.

0x08150A = 529674 → (529674 ÷ 10000) = 52.9674 Ah

Formula
(val ÷ 10000)
Range
0 to 1000 Ah
Unit
Ah

Confirmed for 2012 to 2013, 2015, 2017. In testing for 2010 to 2011, 2014, 2016.

High voltage battery charge LEAF_HVBAT_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Request21 01
  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing for 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 248 to 271 of the reply, 24 bits.

0x0CEDB6 = 847286 → (847286 ÷ 8190 − 17) = 86.453724 %

Formula
(val ÷ 8190 − 17)
Range
0 to 100 %
Unit
%

Confirmed for 2018 to 2019, 2021 to 2022, 2024. In testing for 2020, 2023, 2025 to 2026.

High voltage battery charge LEAF_HVBAT_SOC_PRE18Confirmed

Pelican can show this parameter as the state of charge.

  • Request21 01
  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing for 2010 to 2011, 2014, 2016

Example reply from a 2017 Nissan LEAF.

Bits 232 to 255 of the reply, 24 bits.

0x0E6033 = 942131 → (942131 ÷ 10000) = 94.2131 %

Formula
(val ÷ 10000)
Range
0 to 100 %
Unit
%

Confirmed for 2012 to 2013, 2015, 2017. In testing for 2010 to 2011, 2014, 2016.

High voltage battery health LEAF_HVBAT_SOHConfirmed

When the battery is new, its health should be ~100%.

Pelican can show this parameter as the state of health.

  • Request21 61
  • Service 21PID 61
  • Module79B → 7BB
  • Every3600 s
  • Testing for 2010 to 2011, 2014, 2016, 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 16 to 31 of the reply, 16 bits.

0x2466 = 9318 → (9318 ÷ 100) = 93.18 %

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2012 to 2013, 2015, 2017 to 2019, 2021 to 2022, 2024. In testing for 2010 to 2011, 2014, 2016, 2020, 2023, 2025 to 2026.

High voltage battery voltage LEAF_HVBAT_VOLTConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Request21 01
  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing for 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 144 to 159 of the reply, 16 bits.

0x9783 = 38787 → (38787 ÷ 100) = 387.87 V

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

Confirmed for 2018 to 2019, 2021 to 2022, 2024. In testing for 2020, 2023, 2025 to 2026.

High voltage battery voltage LEAF_HVBAT_VOLT_PRE18Confirmed

Pelican can show this parameter as the traction battery voltage.

  • Request21 01
  • Service 21PID 01
  • Module79B → 7BB
  • Every1 s
  • Testing for 2010 to 2011, 2014, 2016

Example reply from a 2017 Nissan LEAF.

Bits 144 to 159 of the reply, 16 bits.

0x986F = 39023 → (39023 ÷ 100) = 390.23 V

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

Confirmed for 2012 to 2013, 2015, 2017. In testing for 2010 to 2011, 2014, 2016.

HV battery current LEAF_HVBAT_IConfirmed

Pelican can show this parameter as the traction battery current.

  • Request22 12 48
  • Service 22DID 1248
  • Module797 → 79A
  • Every1 s
  • Testing for 2010 to 2017, 2019 to 2026

Example reply from a 2018 Nissan LEAF.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 ÷ 2) = 0 A

Formula
(val ÷ 2)
Range
-16384 to 16383.5 A
Unit
A

Confirmed for 2018. In testing for 2010 to 2017, 2019 to 2026.

HV battery pack 1 temperature LEAF_HVBAT_PACK_1_T

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 16 to 23 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery pack 2 temperature LEAF_HVBAT_PACK_2_T

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery pack 4 temperature LEAF_HVBAT_PACK_4_T

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery pack 5 temperature LEAF_HVBAT_PACK_5_T

  • Request21 04
  • Service 21PID 04
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 °C
Unit
°C

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery pack voltage LEAF_HVBAT_PACK_V

Pelican can show this parameter as the traction battery voltage.

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,536 to 1,551 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV bus voltage LEAF_HVBAT_BUS_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,552 to 1,567 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

L1/L2 charge port plug state LEAF_CHARGE_PLUGConfirmed

Pelican can show this parameter as the plug state.

  • Request22 12 34
  • Service 22DID 1234
  • Module797 → 79A
  • Every1 s
  • Testing for 2014, 2016, 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → UNPLUGGED

Unit
Named states
States
Raw valueStateMeaning
0UNPLUGGEDNot plugged in
1PLUGGED_PARTIALPartially plugged in
2PLUGGEDPlugged in

Confirmed for 2013, 2015, 2017 to 2019, 2021 to 2022, 2024. In testing for 2014, 2016, 2020, 2023, 2025 to 2026. Not supported for 2012.

Maximum cell voltage LEAF_MAX_CELL_VConfirmed

  • Request21 03
  • Service 21PID 03
  • Module79B → 7BB
  • Every1 s
  • Testing for 2010 to 2017, 2019 to 2026

Example reply from a 2018 Nissan LEAF.

Bits 80 to 95 of the reply, 16 bits.

0x0D5B = 3419 → (3419 ÷ 1000) = 3.419 V

Formula
(val ÷ 1000)
Range
0 to 4.5 V
Unit
V

Confirmed for 2018. In testing for 2010 to 2017, 2019 to 2026.

Minimum cell voltage LEAF_MIN_CELL_VConfirmed

  • Request21 03
  • Service 21PID 03
  • Module79B → 7BB
  • Every1 s
  • Testing for 2010 to 2017, 2019 to 2026

Example reply from a 2018 Nissan LEAF.

Bits 96 to 111 of the reply, 16 bits.

0x0D36 = 3382 → (3382 ÷ 1000) = 3.382 V

Formula
(val ÷ 1000)
Range
0 to 4.5 V
Unit
V

Confirmed for 2018. In testing for 2010 to 2017, 2019 to 2026.

State of charge, as the dash shows it LEAF_SOC_DASHConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 0E 2D
  • Service 22DID 0E2D
  • Module743 → 763
  • Every30 s
  • Testing for 2019 to 2026

Example reply from a 2018 Nissan LEAF.

Bits 112 to 119 of the reply, 8 bits.

0x0D = 13 → 13 %

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2018. In testing for 2019 to 2026.

Battery › Cells

HV battery cell 1 voltage LEAF_HVBAT_CELL_1_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 2 voltage LEAF_HVBAT_CELL_2_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 3 voltage LEAF_HVBAT_CELL_3_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 32 to 47 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 4 voltage LEAF_HVBAT_CELL_4_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 48 to 63 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 5 voltage LEAF_HVBAT_CELL_5_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 6 voltage LEAF_HVBAT_CELL_6_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 7 voltage LEAF_HVBAT_CELL_7_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 8 voltage LEAF_HVBAT_CELL_8_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 9 voltage LEAF_HVBAT_CELL_9_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 10 voltage LEAF_HVBAT_CELL_10_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 144 to 159 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 11 voltage LEAF_HVBAT_CELL_11_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 12 voltage LEAF_HVBAT_CELL_12_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 13 voltage LEAF_HVBAT_CELL_13_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 14 voltage LEAF_HVBAT_CELL_14_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 15 voltage LEAF_HVBAT_CELL_15_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 16 voltage LEAF_HVBAT_CELL_16_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 17 voltage LEAF_HVBAT_CELL_17_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 18 voltage LEAF_HVBAT_CELL_18_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 19 voltage LEAF_HVBAT_CELL_19_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 20 voltage LEAF_HVBAT_CELL_20_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 21 voltage LEAF_HVBAT_CELL_21_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 22 voltage LEAF_HVBAT_CELL_22_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 23 voltage LEAF_HVBAT_CELL_23_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 24 voltage LEAF_HVBAT_CELL_24_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 368 to 383 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 25 voltage LEAF_HVBAT_CELL_25_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 384 to 399 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 26 voltage LEAF_HVBAT_CELL_26_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 400 to 415 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 27 voltage LEAF_HVBAT_CELL_27_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 416 to 431 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 28 voltage LEAF_HVBAT_CELL_28_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 432 to 447 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 29 voltage LEAF_HVBAT_CELL_29_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 448 to 463 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 30 voltage LEAF_HVBAT_CELL_30_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 464 to 479 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 31 voltage LEAF_HVBAT_CELL_31_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 480 to 495 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 32 voltage LEAF_HVBAT_CELL_32_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 496 to 511 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 33 voltage LEAF_HVBAT_CELL_33_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 512 to 527 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 34 voltage LEAF_HVBAT_CELL_34_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 528 to 543 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 35 voltage LEAF_HVBAT_CELL_35_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 544 to 559 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 36 voltage LEAF_HVBAT_CELL_36_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 560 to 575 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 37 voltage LEAF_HVBAT_CELL_37_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 576 to 591 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 38 voltage LEAF_HVBAT_CELL_38_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 592 to 607 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 39 voltage LEAF_HVBAT_CELL_39_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 608 to 623 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 40 voltage LEAF_HVBAT_CELL_40_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 624 to 639 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 41 voltage LEAF_HVBAT_CELL_41_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 640 to 655 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 42 voltage LEAF_HVBAT_CELL_42_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 656 to 671 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 43 voltage LEAF_HVBAT_CELL_43_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 672 to 687 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 44 voltage LEAF_HVBAT_CELL_44_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 688 to 703 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 45 voltage LEAF_HVBAT_CELL_45_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 704 to 719 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 46 voltage LEAF_HVBAT_CELL_46_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 720 to 735 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 47 voltage LEAF_HVBAT_CELL_47_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 736 to 751 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 48 voltage LEAF_HVBAT_CELL_48_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 752 to 767 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 49 voltage LEAF_HVBAT_CELL_49_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 768 to 783 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 50 voltage LEAF_HVBAT_CELL_50_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 784 to 799 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 51 voltage LEAF_HVBAT_CELL_51_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 800 to 815 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 52 voltage LEAF_HVBAT_CELL_52_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 816 to 831 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 53 voltage LEAF_HVBAT_CELL_53_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 832 to 847 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 54 voltage LEAF_HVBAT_CELL_54_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 848 to 863 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 55 voltage LEAF_HVBAT_CELL_55_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 864 to 879 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 56 voltage LEAF_HVBAT_CELL_56_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 880 to 895 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 57 voltage LEAF_HVBAT_CELL_57_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 896 to 911 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 58 voltage LEAF_HVBAT_CELL_58_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 912 to 927 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 59 voltage LEAF_HVBAT_CELL_59_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 928 to 943 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 60 voltage LEAF_HVBAT_CELL_60_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 944 to 959 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 61 voltage LEAF_HVBAT_CELL_61_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 960 to 975 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 62 voltage LEAF_HVBAT_CELL_62_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 976 to 991 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 63 voltage LEAF_HVBAT_CELL_63_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 992 to 1,007 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 64 voltage LEAF_HVBAT_CELL_64_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,008 to 1,023 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 65 voltage LEAF_HVBAT_CELL_65_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,024 to 1,039 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 66 voltage LEAF_HVBAT_CELL_66_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,040 to 1,055 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 67 voltage LEAF_HVBAT_CELL_67_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,056 to 1,071 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 68 voltage LEAF_HVBAT_CELL_68_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,072 to 1,087 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 69 voltage LEAF_HVBAT_CELL_69_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,088 to 1,103 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 70 voltage LEAF_HVBAT_CELL_70_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,104 to 1,119 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 71 voltage LEAF_HVBAT_CELL_71_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,120 to 1,135 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 72 voltage LEAF_HVBAT_CELL_72_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,136 to 1,151 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 73 voltage LEAF_HVBAT_CELL_73_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,152 to 1,167 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 74 voltage LEAF_HVBAT_CELL_74_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,168 to 1,183 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 75 voltage LEAF_HVBAT_CELL_75_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,184 to 1,199 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 76 voltage LEAF_HVBAT_CELL_76_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,200 to 1,215 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 77 voltage LEAF_HVBAT_CELL_77_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,216 to 1,231 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 78 voltage LEAF_HVBAT_CELL_78_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,232 to 1,247 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 79 voltage LEAF_HVBAT_CELL_79_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,248 to 1,263 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 80 voltage LEAF_HVBAT_CELL_80_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,264 to 1,279 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 81 voltage LEAF_HVBAT_CELL_81_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,280 to 1,295 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 82 voltage LEAF_HVBAT_CELL_82_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,296 to 1,311 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 83 voltage LEAF_HVBAT_CELL_83_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,312 to 1,327 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 84 voltage LEAF_HVBAT_CELL_84_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,328 to 1,343 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 85 voltage LEAF_HVBAT_CELL_85_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,344 to 1,359 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 86 voltage LEAF_HVBAT_CELL_86_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,360 to 1,375 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 87 voltage LEAF_HVBAT_CELL_87_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,376 to 1,391 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 88 voltage LEAF_HVBAT_CELL_88_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,392 to 1,407 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 89 voltage LEAF_HVBAT_CELL_89_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,408 to 1,423 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 90 voltage LEAF_HVBAT_CELL_90_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,424 to 1,439 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 91 voltage LEAF_HVBAT_CELL_91_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,440 to 1,455 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 92 voltage LEAF_HVBAT_CELL_92_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,456 to 1,471 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 93 voltage LEAF_HVBAT_CELL_93_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,472 to 1,487 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 94 voltage LEAF_HVBAT_CELL_94_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,488 to 1,503 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 95 voltage LEAF_HVBAT_CELL_95_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,504 to 1,519 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

HV battery cell 96 voltage LEAF_HVBAT_CELL_96_V

  • Request21 02
  • Service 21PID 02
  • Module79B → 7BB
  • Every30 s
  • Testing

Bits 1,520 to 1,535 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65.535 V
Unit
V

In testing for 2010 to 2017, 2019 to 2026. Not supported for 2018.

Battery › Draw

Power used by air conditioning LEAF_AC_PWR_ESTConfirmed

  • Request22 12 61
  • Service 22DID 1261
  • Module797 → 79A
  • Every1 s
  • Testing for 2014, 2016, 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 50) = 0 W

Formula
(val × 50)
Range
0 to 12750 W
Unit
W

Confirmed for 2013, 2015, 2017 to 2019, 2021 to 2022, 2024. In testing for 2014, 2016, 2020, 2023, 2025 to 2026. Not supported for 2012.

Power used by auxiliary equipment (lights, radio, navigation, rear defroster, etc...). LEAF_AUX_PWRConfirmed

  • Request22 11 52
  • Service 22DID 1152
  • Module797 → 79A
  • Every1 s
  • Testing for 2014, 2016, 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 100) = 0 W

Formula
(val × 100)
Range
0 to 25500 W
Unit
W

Confirmed for 2013, 2015, 2017 to 2019, 2021 to 2022, 2024. In testing for 2014, 2016, 2020, 2023, 2025 to 2026. Not supported for 2012.

Power used by both the A/C and PTC heater. LEAF_AC_PWRConfirmed

  • Request22 11 51
  • Service 22DID 1151
  • Module797 → 79A
  • Every1 s
  • Testing for 2014, 2016, 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 250) = 0 W

Formula
(val × 250)
Range
0 to 63750 W
Unit
W

Confirmed for 2013, 2015, 2017 to 2019, 2021 to 2022, 2024. In testing for 2014, 2016, 2020, 2023, 2025 to 2026. Not supported for 2012.

Power used by cabin positive temperature coefficient (PTC) heaters. LEAF_HTR_PWRConfirmed

  • Request22 12 62
  • Service 22DID 1262
  • Module797 → 79A
  • Every1 s
  • Testing for 2014, 2016, 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 250) = 0 W

Formula
(val × 250)
Range
0 to 63750 W
Unit
W

Confirmed for 2013, 2015, 2017 to 2019, 2021 to 2022, 2024. In testing for 2014, 2016, 2020, 2023, 2025 to 2026. Not supported for 2012.

Battery › Statistics

Quick charge count LEAF_L1L2CHRG_CNTConfirmed

Increments each time an L1/L2 charge occurs, even if only partially.

  • Request22 12 05
  • Service 22DID 1205
  • Module797 → 79A
  • Every1 s
  • Testing for 2014, 2016, 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 0 to 15 of the reply, 16 bits.

0x0345 = 837 → 837

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2013, 2015, 2017 to 2019, 2021 to 2022, 2024. In testing for 2014, 2016, 2020, 2023, 2025 to 2026. Not supported for 2012.

Quick charge count LEAF_QCKCHRG_CNTConfirmed

Increments each time a quick charge occurs, even if only partially.

  • Request22 12 03
  • Service 22DID 1203
  • Module797 → 79A
  • Every1 s
  • Testing for 2014, 2016, 2020, 2023, 2025 to 2026

Example reply from a 2024 Nissan LEAF.

Bits 0 to 15 of the reply, 16 bits.

0x000D = 13 → 13

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2013, 2015, 2017 to 2019, 2021 to 2022, 2024. In testing for 2014, 2016, 2020, 2023, 2025 to 2026. Not supported for 2012.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.