Engine parameters
The Nissan ARIYA has 98 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
Actual EGR A duty cycle/position EGR_A_ACTSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023.
Actual EGR B duty cycle/position EGR_B_ACTSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2024 to 2025. Supported for 2023.
Boost pressure sensor A BP_A_ACTSAE J1979Confirmed
Actual turbocharger/supercharger A boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2024 to 2025. Supported for 2023.
Boost pressure sensor B BP_B_ACTSAE J1979Confirmed
Actual turbocharger/supercharger B boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2024 to 2025. Supported for 2023.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023 to 2025.
Commanded boost pressure A BP_A_CMDSAE J1979Confirmed
Turbocharger/supercharger A commanded boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2024 to 2025. Supported for 2023.
Commanded boost pressure B BP_B_CMDSAE J1979Confirmed
Turbocharger/supercharger B commanded boost pressure.
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 kPa
- Unit
- kPa
Confirmed for 2024 to 2025. Supported for 2023.
Commanded EGR A duty cycle/position EGR_A_CMDSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023.
Commanded EGR B duty cycle/position EGR_B_CMDSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023.
Commanded Throttle Actuator A Control TAC_A_CMDSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023.
Commanded Throttle Actuator B Control TAC_B_CMDSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023.
Commanded wastegate A position WG_A_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023.
Commanded wastegate B position WG_B_CMDSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023.
EGR A error EGR_A_ERRSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023.
EGR B error EGR_B_ERRSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2023 to 2025.
Engine coolant temperature 1 ECT_1SAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024 to 2025. Supported for 2023.
Engine coolant temperature 2 ECT_2SAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024 to 2025. Supported for 2023.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2024 to 2025. Supported for 2023.
Exhaust Gas Recirculation Temp Sensor A (Bank 1, Sensor 1) EGRTASAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025. Supported for 2023 to 2024.
Exhaust Gas Recirculation Temp Sensor B (Bank 2, Sensor 1) EGRTBSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025. Supported for 2023 to 2024.
Exhaust Gas Recirculation Temp Sensor C (Bank 1, Sensor 2) EGRTCSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025. Supported for 2023 to 2024.
Exhaust Gas Recirculation Temp Sensor D (Bank 2, Sensor 2) EGRTDSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2025. Supported for 2023 to 2024.
Mass Air Flow Sensor A MAFASAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 66 - Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 g/s
- Unit
- g/s
Confirmed for 2023 to 2025.
Mass Air Flow Sensor B MAFBSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 66 - Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 g/s
- Unit
- g/s
Confirmed for 2023 to 2025.
Relative Throttle A Position TP_A_RELSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023.
Relative Throttle B Position TP_B_RELSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023.
Total Engine Run Time RUN_TIMESAE J1979Confirmed
- Request
01 7F - Service 01
PID 7F - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 39 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 s
- Unit
- s
Confirmed for 2024 to 2025. Supported for 2023.
Total Idle Run Time IDLE_TIMESAE J1979Confirmed
- Request
01 7F - Service 01
PID 7F - Module
7E0 → 7E8 - Every
1 s
Bits 40 to 71 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 s
- Unit
- s
Confirmed for 2024 to 2025. Supported for 2023.
Total Run Time With PTO Active PTO_TIMESAE J1979Confirmed
- Request
01 7F - Service 01
PID 7F - Module
7E0 → 7E8 - Every
1 s
Bits 72 to 103 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 s
- Unit
- s
Confirmed for 2024 to 2025. Supported for 2023.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Request
01 51 - Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2024 to 2025. Supported for 2023.
Wastegate A position WG_A_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023.
Wastegate B position WG_B_ACTSAE J1979Confirmed
If an on/off solenoid is used, is 0% when the wastegate is commanded off (allow full boost), 100% when commanded on (dump boost). If a vacuum solenoid is duty cycled, the duty cycle from 0 to 100% is displayed. If a linear or stepper motor valve is used, the fully closed position (full boost) is displayed as 0%, the fully open position (dump boost) is displayed as 100%. Intermediate positions are displayed as a percent of the full-open position. Any other actuation method is normalized to display 0% when the WG is commanded off and 100% when the WG is commanded on.
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024 to 2025. Supported for 2023.
Engine › AuxInputs
Auto Trans Neutral Drive Status N/D_STATSAE J1979Confirmed
- Request
01 65 - Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Glow plug lamp status GPL_STATSAE J1979Confirmed
- Request
01 65 - Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 12 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Manual Trans Neutral Gear Status N/G_STATSAE J1979Confirmed
- Request
01 65 - Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Power Take Off (PTO) Output Status PTO_STAT_AUXSAE J1979Confirmed
- Request
01 65 - Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Recommended gear GEAR_RCMDSAE J1979Confirmed
- Request
01 65 - Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 11 of the reply, 4 bits.
- Formula
val- Range
- 0 to 15
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Engine › AuxInputs › Internal
Auto trans neutral drive status supported N/D_SUPSAE J1979Confirmed
- Request
01 65 - Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Glow plug lamp status supported GPL_SUPSAE J1979Confirmed
- Request
01 65 - Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Manual trans neutral gear status supported N/G_SUPSAE J1979Confirmed
- Request
01 65 - Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Power Take Off (PTO) output status supported PTO_SUPSAE J1979Confirmed
- Request
01 65 - Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Recommended gear supported GEAR_SUPSAE J1979Confirmed
- Request
01 65 - Service 01
PID 65 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Engine › Internal
Actual EGR A supported EGR_A_ACT_SUPSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Actual EGR A supported EGR_B_ACT_SUPSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Boost pressure A control status supported BP_A_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Boost pressure A supported BP_A_ACT_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Boost pressure B control status supported BP_B_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Boost pressure B supported BP_B_ACT_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Commanded boost pressure A supported BP_A_CMD_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Commanded boost pressure B supported BP_B_CMD_SUPSAE J1979Confirmed
- Request
01 70 - Service 01
PID 70 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Commanded EGR A supported EGR_A_CMD_SUPSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Commanded EGR A supported EGR_B_CMD_SUPSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Commanded Throttle Actuator A Control supported? CTAC_A_SUPSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Commanded Throttle Actuator B Control supported? CTAC_B_SUPSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Commanded wastegate A position supported WG_A_CMD_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Commanded wastegate B position supported WG_B_CMD_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
EGR A error supported EGR_A_ERR_SUPSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
EGR A error supported EGR_B_ERR_SUPSAE J1979Confirmed
- Request
01 69 - Service 01
PID 69 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
EGR Temperature Sensor A (Bank 1, Sensor 1) supported? EGRTA_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023 to 2024.
EGR Temperature Sensor A (Bank 1, Sensor 1) Wide Range supported? EGRTA_WR_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023 to 2024.
EGR Temperature Sensor B (Bank 2, Sensor 1) supported? EGRTB_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023 to 2024.
EGR Temperature Sensor B (Bank 2, Sensor 1) Wide Range supported? EGRTB_WR_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023 to 2024.
EGR Temperature Sensor C (Bank 1, Sensor 2) supported? EGRTC_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023 to 2024.
EGR Temperature Sensor C (Bank 1, Sensor 2) Wide Range supported? EGRTC_WR_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023 to 2024.
EGR Temperature Sensor D (Bank 2, Sensor 2) supported? EGRTD_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023 to 2024.
EGR Temperature Sensor D (Bank 2, Sensor 2) Wide Range supported? EGRTD_WR_SUPSAE J1979Confirmed
- Request
01 6B - Service 01
PID 6B - Module
7E0 → 7E8 - Every
250 ms
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2025. Supported for 2023 to 2024.
IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed
- Request
01 68 - Service 01
PID 68 - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2024 to 2025. Supported for 2023.
Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2024 to 2025. Supported for 2023.
MAF Sensor A supported MAFA_SUPSAE J1979Confirmed
- Request
01 66 - Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2025.
MAF Sensor B supported MAFB_SUPSAE J1979Confirmed
- Request
01 66 - Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2023 to 2025.
Maximum value for air flow rate from mass air flow sensor MAX_MAFSAE J1979Confirmed
- Request
01 50 - Service 01
PID 50 - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 g/s
- Unit
- g/s
Confirmed for 2024 to 2025. Supported for 2023.
Maximum value for equivalence ratio MAX_EQ_RATSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2024 to 2025. Supported for 2023.
Maximum value for intake manifold absolute pressure (MAP) MAX_MAPSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 kPa
- Unit
- kPa
Confirmed for 2024 to 2025. Supported for 2023.
Maximum value for oxygen sensor current MAX_O2_CURRSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 mA
- Unit
- mA
Confirmed for 2024 to 2025. Supported for 2023.
Maximum value for oxygen sensor voltage MAX_O2_VOLTSAE J1979Confirmed
- Request
01 4F - Service 01
PID 4F - Module
7E0 → 7E8 - Every
3600 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
Confirmed for 2024 to 2025. Supported for 2023.
Relative Throttle A Position data supported? RTP_A_SUPSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Relative Throttle B Position data supported? RTP_B_SUPSAE J1979Confirmed
- Request
01 6C - Service 01
PID 6C - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Total Engine Run Time supported? RUN_TIME_SUPSAE J1979Confirmed
- Request
01 7F - Service 01
PID 7F - Module
7E0 → 7E8 - Every
1 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Total Idle Run Time supported? IDLE_TIME_SUPSAE J1979Confirmed
- Request
01 7F - Service 01
PID 7F - Module
7E0 → 7E8 - Every
1 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Total Run Time With PTO Active supported? PTO_TIME_SUPSAE J1979Confirmed
- Request
01 7F - Service 01
PID 7F - Module
7E0 → 7E8 - Every
1 s
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Wastegate A position supported WG_A_ACT_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Wastegate B position supported WG_B_ACT_SUPSAE J1979Confirmed
- Request
01 72 - Service 01
PID 72 - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
Engine › OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024 to 2025. Supported for 2023.