Control parameters
The Mitsubishi Outlander has 10 control parameters.
● Confirmed◆ In testing○ Supported× Not supported
Absolute throttle position TPSAE J1979Confirmed
Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.
Pelican can show this parameter as the throttle position.
- Request
01 11 - Service 01
PID 11 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2014 to 2015, 2018 to 2020, 2022 to 2023, 2025.
Absolute throttle position B TP_BSAE J1979Confirmed
Pelican can show this parameter as the throttle position.
- Request
01 47 - Service 01
PID 47 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2019, 2022 to 2023, 2025.
Brake pedal OUTLANDER_CVT_BRAKE
- Request
21 07 - Service 21
PID 07 - Module
7E1 - Every
250 ms - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2021. Not supported for 2024.
Brake status OUTLANDER_AWC_BRAKE_STS
- Request
21 0D - Service 21
PID 0D - Module
7B6 → 7B7 - Every
250 ms - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2021. Not supported for 2024.
Brake switch OUTLANDER_MPI_BRAKE_SWITCH
- Request
21 1D - Service 21
PID 1D - Module
7E0 - Every
250 ms - Testing
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2021. Not supported for 2024.
Normal brake closed status OUTLANDER_MPI_NORMAL_BRAKE_CLOSED_STS
- Request
21 1D - Service 21
PID 1D - Module
7E0 - Every
250 ms - Testing
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2021. Not supported for 2024.
Parking brake OUTLANDER_AWC_PARKING_BRAKE
- Request
21 0D - Service 21
PID 0D - Module
7B6 → 7B7 - Every
250 ms - Testing
Bit 15 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2001 to 2021. Not supported for 2024.
Relative throttle position TP_RSAE J1979Confirmed
Relative or 'learned' throttle position.
- Request
01 45 - Service 01
PID 45 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2015, 2018 to 2020, 2022 to 2023, 2025.
Control › Pedals
Accelerator pedal position D APP_DSAE J1979Confirmed
- Request
01 49 - Service 01
PID 49 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2015, 2018, 2020, 2022 to 2023, 2025.
Accelerator pedal position E APP_ESAE J1979Confirmed
- Request
01 4A - Service 01
PID 4A - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2015, 2018, 2020, 2022 to 2023, 2025.