Mitsubishi Outlander PHEV

Control parameters

The Mitsubishi Outlander PHEV has 5 control parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Brake pedal MITSUBISHI_CVT_BRAKE

  • Request21 07
  • Service 21PID 07
  • Module7E1
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2022, 2024, 2026. Not supported for 2023, 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Brake pedal MITSUBISHI_CVT_BRAKE

  • Request21 07
  • Service 21PID 07
  • Module7E1
  • Every250 ms
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2022, 2024, 2026. Not supported for 2023, 2025.

Brake status MITSUBISHI_AWC_BRAKE_STS

  • Request21 0D
  • Service 21PID 0D
  • Module7B6 → 7B7
  • Every250 ms
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2022, 2024, 2026. Not supported for 2023, 2025.

Brake switch MITSUBISHI_MPI_BRAKE_SWITCH

  • Request21 1D
  • Service 21PID 1D
  • Module7E0
  • Every250 ms
  • Testing

Bit 31 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2022, 2024, 2026. Not supported for 2023, 2025.

Normal brake closed status MITSUBISHI_MPI_NORMAL_BRAKE_CLOSED_STS

  • Request21 1D
  • Service 21PID 1D
  • Module7E0
  • Every250 ms
  • Testing

Bit 30 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2022, 2024, 2026. Not supported for 2023, 2025.

Parking brake MITSUBISHI_AWC_PARKING_BRAKE

  • Request21 0D
  • Service 21PID 0D
  • Module7B6 → 7B7
  • Every250 ms
  • Testing

Bit 15 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2013 to 2022, 2024, 2026. Not supported for 2023, 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.