Battery parameters
The MG Hector has 247 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
Charge current limit MG_CHG_A_LIMIT
- Request
22 B7 12 - Service 22
DID B712 - Module
7E3 → 7EB - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Charger connected MG_CHG_CONNECTED
Pelican can show this parameter as the plug state.
- Request
22 B7 1B - Service 22
DID B71B - Module
7E3 → 7EB - Every
5 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2023.
High voltage battery current MG_HBAT_C
- Request
22 B0 43 - Service 22
DID B043 - Module
781 → 789 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40 − 1000)- Range
- -1000 to 638.375 mA
- Unit
- mA
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
High voltage battery voltage MG_HBAT_V
- Request
22 B0 42 - Service 22
DID B042 - Module
781 → 789 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 300 to 450 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Highest cell voltage MG_HVBAT_CELL_V_MAX
- Request
22 B0 58 - Service 22
DID B058 - Module
7E5 → 7ED - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Highest cell voltage MG_HVBAT_CELL_V_MAX_GEN1
- Request
22 B0 58 - Service 22
DID B058 - Module
781 → 789 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery coolant temperature MG_HVBAT_COOLANT_TEMP
- Request
22 B0 5C - Service 22
DID B05C - Module
7DF → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery coolant temperature MG_HVBAT_COOLANT_TEMP_GEN1
- Request
22 B0 5C - Service 22
DID B05C - Module
781 → 789 - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery coolant temperature MG_HVBAT_COOLANT_TEMP_V2
- Request
22 B0 5C - Service 22
DID B05C - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery current MG_HVBAT_CURRENT
- Request
22 B0 43 - Service 22
DID B043 - Module
7DF → 7ED - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 40 − 1000)- Range
- 0 to 250 A
- Unit
- A
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery current MG_HVBAT_CURRENT_V2
- Request
22 B0 43 - Service 22
DID B043 - Module
7E5 → 7ED - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.025 − 1000)- Range
- 0 to 250 A
- Unit
- A
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery error code MG_HVBAT_ERR
- Request
22 B0 47 - Service 22
DID B047 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery error code MG_HVBAT_ERR_GEN1
- Request
22 B0 47 - Service 22
DID B047 - Module
781 → 789 - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery health MG_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Request
22 B0 61 - Service 22
DID B061 - Module
7DF → 7ED - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery health MG_HVBAT_SOH_V2
Pelican can show this parameter as the state of health.
- Request
22 B0 61 - Service 22
DID B061 - Module
7E5 → 7ED - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery is charging? MG_HVBAT_CHARGING
Pelican can show this parameter as the charging state.
- Request
22 B0 48 - Service 22
DID B048 - Module
7DF → 7ED - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery is charging? MG_HVBAT_CHARGING_V2
- Request
22 B0 48 - Service 22
DID B048 - Module
7E5 → 7ED - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery main relay B state MG_HVBAT_RELAY_B
- Request
22 B0 49 - Service 22
DID B049 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery main relay B state MG_HVBAT_RELAY_B_GEN1
- Request
22 B0 49 - Service 22
DID B049 - Module
781 → 789 - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery main relay G state MG_HVBAT_RELAY_G
- Request
22 B0 4A - Service 22
DID B04A - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery main relay G state MG_HVBAT_RELAY_G_GEN1
- Request
22 B0 4A - Service 22
DID B04A - Module
781 → 789 - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery main relay P state MG_HVBAT_RELAY_P
- Request
22 B0 52 - Service 22
DID B052 - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery main relay P state MG_HVBAT_RELAY_P_GEN1
- Request
22 B0 52 - Service 22
DID B052 - Module
781 → 789 - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery range count MG_HVBAT_RANGE_RAW
- Request
22 B0 CE - Service 22
DID B0CE - Module
7E5 → 7ED - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery range count MG_HVBAT_RANGE_RAW_GEN1
- Request
22 B0 CE - Service 22
DID B0CE - Module
781 → 789 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery temperature MG_HVBAT_TEMP
- Request
22 B0 56 - Service 22
DID B056 - Module
7DF → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery temperature MG_HVBAT_TEMP_GEN1
- Request
22 B0 56 - Service 22
DID B056 - Module
781 → 789 - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery temperature MG_HVBAT_TEMP_V2
- Request
22 B0 56 - Service 22
DID B056 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery voltage MG_HVBAT_VOLTAGE
- Request
22 B0 42 - Service 22
DID B042 - Module
7DF → 7ED - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 500 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery voltage MG_HVBAT_VOLTAGE_V2
- Request
22 B0 42 - Service 22
DID B042 - Module
7E5 → 7ED - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.25)- Range
- 0 to 500 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery voltage, vehicle control unit MG_HVBAT_V_VCU
- Request
22 B7 05 - Service 22
DID B705 - Module
7E3 → 7EB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV contactor closed MG_HV_CONTACTOR
- Request
22 B7 03 - Service 22
DID B703 - Module
7E3 → 7EB - Every
5 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Is charging MG_IS_CHARGING
Pelican can show this parameter as the charging state.
- Request
22 B0 48 - Service 22
DID B048 - Module
781 → 789 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Is DC fast charging MG_IS_DCFC
- Request
22 B0 48 - Service 22
DID B048 - Module
781 → 789 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Yes or no
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Knock sensor voltage MG_KNOCK_SNS_V
- Request
22 B1 40 - Service 22
DID B140 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 5 ÷ 255)- Range
- 0 to 5 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Lowest cell voltage MG_HVBAT_CELL_V_MIN
- Request
22 B0 59 - Service 22
DID B059 - Module
7E5 → 7ED - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Lowest cell voltage MG_HVBAT_CELL_V_MIN_GEN1
- Request
22 B0 59 - Service 22
DID B059 - Module
781 → 789 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
State of charge MG_SOC
Pelican can show this parameter as the state of charge.
- Request
22 B0 46 - Service 22
DID B046 - Module
781 → 789 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
State of health MG_SOH
Pelican can show this parameter as the state of health.
- Request
22 B0 61 - Service 22
DID B061 - Module
781 → 789 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › EVCC
Charging MG_EVCC_CHARGING
- Request
22 B0 0F - Service 22
DID B00F - Module
7DF → 7EC - Every
4 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Charging MG_EVCC_CHARGING_V2
- Request
22 B0 0F - Service 22
DID B00F - Module
7E4 → 7EC - Every
4 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Current MG_EVCC_CURRENT
- Request
22 B0 01 - Service 22
DID B001 - Module
7DF → 7EC - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5 − 409.6)- Range
- 0 to 250 A
- Unit
- A
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Current MG_EVCC_CURRENT_V2
- Request
22 B0 01 - Service 22
DID B001 - Module
7E4 → 7EC - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.2 − 409.6)- Range
- 0 to 250 A
- Unit
- A
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Max current MG_EVCC_MAX_CURRENT
- Request
22 B0 03 - Service 22
DID B003 - Module
7DF → 7EC - Every
180 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.434782609)- Range
- 0 to 110.869565 A
- Unit
- A
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Max Current MG_EVCC_MAX_CURRENT_V2
- Request
22 B0 03 - Service 22
DID B003 - Module
7E4 → 7EC - Every
180 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 0.434782609)- Range
- 0 to 110.869565 A
- Unit
- A
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Voltage MG_EVCC_VOLTAGE
- Request
22 B0 10 - Service 22
DID B010 - Module
7DF → 7EC - Every
4 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 97)- Range
- 0 to 675.618556 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Voltage MG_EVCC_VOLTAGE_V2
- Request
22 B0 10 - Service 22
DID B010 - Module
7E4 → 7EC - Every
4 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0103092783)- Range
- 0 to 675.618553 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Internal
BMS Status MG_BMS_STATUS
- Request
22 B0 48 - Service 22
DID B048 - Module
7DF → 7ED - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery bus voltage MG_HVBAT_BUS_VOLTAGE
- Request
22 B0 41 - Service 22
DID B041 - Module
7DF → 7ED - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 1000 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery bus voltage MG_HVBAT_BUS_VOLTAGE_GEN1
- Request
22 B0 41 - Service 22
DID B041 - Module
781 → 789 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 1000 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery bus voltage MG_HVBAT_BUS_VOLTAGE_V2
- Request
22 B0 41 - Service 22
DID B041 - Module
7E5 → 7ED - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 1000 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery internal resistance MG_HVBAT_RESISTANCE
- Request
22 B0 45 - Service 22
DID B045 - Module
7DF → 7ED - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery internal resistance MG_HVBAT_RESISTANCE_V2
- Request
22 B0 45 - Service 22
DID B045 - Module
7E5 → 7ED - Every
60 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.5)- Range
- 0 to 32767.5
- Unit
- Number
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery raw charge MG_HVBAT_RAW_SOC
HV battery raw charge
- Request
22 B0 46 - Service 22
DID B046 - Module
7DF → 7ED - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 01
HV battery module 01 max temperature MG_HVBAT_CMU01_MAXTEMP
- Request
22 B0 01 - Service 22
DID B001 - Module
7DF → 7EC - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 01 max temperature MG_HVBAT_CMU01_MAXTEMP_V2
- Request
22 B0 01 - Service 22
DID B001 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 01 max voltage MG_HVBAT_CMU01_MAXVOLT
- Request
22 B0 01 - Service 22
DID B001 - Module
7DF → 7EC - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 01 max voltage MG_HVBAT_CMU01_MAXVOLT_V2
- Request
22 B0 01 - Service 22
DID B001 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 01 min temperature MG_HVBAT_CMU01_MINTEMP
- Request
22 B0 01 - Service 22
DID B001 - Module
7DF → 7EC - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 01 min temperature MG_HVBAT_CMU01_MINTEMP_V2
- Request
22 B0 01 - Service 22
DID B001 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 01 min voltage MG_HVBAT_CMU01_MINVOLT
- Request
22 B0 01 - Service 22
DID B001 - Module
7DF → 7EC - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 01 min voltage MG_HVBAT_CMU01_MINVOLT_V2
- Request
22 B0 01 - Service 22
DID B001 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 02
HV battery module 02 max temperature MG_HVBAT_CMU02_MAXTEMP
- Request
22 B0 09 - Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 02 max temperature MG_HVBAT_CMU02_MAXTEMP_V2
- Request
22 B0 09 - Service 22
DID B009 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 02 max voltage MG_HVBAT_CMU02_MAXVOLT
- Request
22 B0 09 - Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 02 max voltage MG_HVBAT_CMU02_MAXVOLT_V2
- Request
22 B0 09 - Service 22
DID B009 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 02 min temperature MG_HVBAT_CMU02_MINTEMP
- Request
22 B0 09 - Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 02 min temperature MG_HVBAT_CMU02_MINTEMP_V2
- Request
22 B0 09 - Service 22
DID B009 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 02 min voltage MG_HVBAT_CMU02_MINVOLT
- Request
22 B0 09 - Service 22
DID B009 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 02 min voltage MG_HVBAT_CMU02_MINVOLT_V2
- Request
22 B0 09 - Service 22
DID B009 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 03
HV battery module 03 max temperature MG_HVBAT_CMU03_MAXTEMP
- Request
22 B0 11 - Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 03 max temperature MG_HVBAT_CMU03_MAXTEMP_V2
- Request
22 B0 11 - Service 22
DID B011 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 03 max voltage MG_HVBAT_CMU03_MAXVOLT
- Request
22 B0 11 - Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 03 max voltage MG_HVBAT_CMU03_MAXVOLT_V2
- Request
22 B0 11 - Service 22
DID B011 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 03 min temperature MG_HVBAT_CMU03_MINTEMP
- Request
22 B0 11 - Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 03 min temperature MG_HVBAT_CMU03_MINTEMP_V2
- Request
22 B0 11 - Service 22
DID B011 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 03 min voltage MG_HVBAT_CMU03_MINVOLT
- Request
22 B0 11 - Service 22
DID B011 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 03 min voltage MG_HVBAT_CMU03_MINVOLT_V2
- Request
22 B0 11 - Service 22
DID B011 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 04
HV battery module 04 max temperature MG_HVBAT_CMU04_MAXTEMP
- Request
22 B0 19 - Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 04 max temperature MG_HVBAT_CMU04_MAXTEMP_V2
- Request
22 B0 19 - Service 22
DID B019 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 04 max voltage MG_HVBAT_CMU04_MAXVOLT
- Request
22 B0 19 - Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 04 max voltage MG_HVBAT_CMU04_MAXVOLT_V2
- Request
22 B0 19 - Service 22
DID B019 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 04 min temperature MG_HVBAT_CMU04_MINTEMP
- Request
22 B0 19 - Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 04 min temperature MG_HVBAT_CMU04_MINTEMP_V2
- Request
22 B0 19 - Service 22
DID B019 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 04 min voltage MG_HVBAT_CMU04_MINVOLT
- Request
22 B0 19 - Service 22
DID B019 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 04 min voltage MG_HVBAT_CMU04_MINVOLT_V2
- Request
22 B0 19 - Service 22
DID B019 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 05
HV battery module 05 max temperature MG_HVBAT_CMU05_MAXTEMP
- Request
22 B0 21 - Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 05 max temperature MG_HVBAT_CMU05_MAXTEMP_V2
- Request
22 B0 21 - Service 22
DID B021 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 05 max voltage MG_HVBAT_CMU05_MAXVOLT
- Request
22 B0 21 - Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 05 max voltage MG_HVBAT_CMU05_MAXVOLT_V2
- Request
22 B0 21 - Service 22
DID B021 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 05 min temperature MG_HVBAT_CMU05_MINTEMP
- Request
22 B0 21 - Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 05 min temperature MG_HVBAT_CMU05_MINTEMP_V2
- Request
22 B0 21 - Service 22
DID B021 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 05 min voltage MG_HVBAT_CMU05_MINVOLT
- Request
22 B0 21 - Service 22
DID B021 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 05 min voltage MG_HVBAT_CMU05_MINVOLT_V2
- Request
22 B0 21 - Service 22
DID B021 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 06
HV battery module 06 max temperature MG_HVBAT_CMU06_MAXTEMP
- Request
22 B0 29 - Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 06 max temperature MG_HVBAT_CMU06_MAXTEMP_V2
- Request
22 B0 29 - Service 22
DID B029 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 06 max voltage MG_HVBAT_CMU06_MAXVOLT
- Request
22 B0 29 - Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 06 max voltage MG_HVBAT_CMU06_MAXVOLT_V2
- Request
22 B0 29 - Service 22
DID B029 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 06 min temperature MG_HVBAT_CMU06_MINTEMP
- Request
22 B0 29 - Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 06 min temperature MG_HVBAT_CMU06_MINTEMP_V2
- Request
22 B0 29 - Service 22
DID B029 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 06 min voltage MG_HVBAT_CMU06_MINVOLT
- Request
22 B0 29 - Service 22
DID B029 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 06 min voltage MG_HVBAT_CMU06_MINVOLT_V2
- Request
22 B0 29 - Service 22
DID B029 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 07
HV battery module 07 max temperature MG_HVBAT_CMU07_MAXTEMP
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 07 max temperature MG_HVBAT_CMU07_MAXTEMP_V2
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 07 max voltage MG_HVBAT_CMU07_MAXVOLT
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 07 max voltage MG_HVBAT_CMU07_MAXVOLT_V2
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 07 min temperature MG_HVBAT_CMU07_MINTEMP
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 07 min temperature MG_HVBAT_CMU07_MINTEMP_V2
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 07 min voltage MG_HVBAT_CMU07_MINVOLT
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 07 min voltage MG_HVBAT_CMU07_MINVOLT_V2
- Request
22 B0 A3 - Service 22
DID B0A3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 08
HV battery module 08 max temperature MG_HVBAT_CMU08_MAXTEMP
- Request
22 B0 AB - Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 08 max temperature MG_HVBAT_CMU08_MAXTEMP_V2
- Request
22 B0 AB - Service 22
DID B0AB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 08 max voltage MG_HVBAT_CMU08_MAXVOLT
- Request
22 B0 AB - Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 08 max voltage MG_HVBAT_CMU08_MAXVOLT_V2
- Request
22 B0 AB - Service 22
DID B0AB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 08 min temperature MG_HVBAT_CMU08_MINTEMP
- Request
22 B0 AB - Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 08 min temperature MG_HVBAT_CMU08_MINTEMP_V2
- Request
22 B0 AB - Service 22
DID B0AB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 08 min voltage MG_HVBAT_CMU08_MINVOLT
- Request
22 B0 AB - Service 22
DID B0AB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 08 min voltage MG_HVBAT_CMU08_MINVOLT_V2
- Request
22 B0 AB - Service 22
DID B0AB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 09
HV battery module 09 max temperature MG_HVBAT_CMU09_MAXTEMP
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 09 max temperature MG_HVBAT_CMU09_MAXTEMP_V2
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 09 max voltage MG_HVBAT_CMU09_MAXVOLT
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 09 max voltage MG_HVBAT_CMU09_MAXVOLT_V2
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 09 min temperature MG_HVBAT_CMU09_MINTEMP
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 09 min temperature MG_HVBAT_CMU09_MINTEMP_V2
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 09 min voltage MG_HVBAT_CMU09_MINVOLT
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 09 min voltage MG_HVBAT_CMU09_MINVOLT_V2
- Request
22 B0 B3 - Service 22
DID B0B3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 10
HV battery module 10 max temperature MG_HVBAT_CMU10_MAXTEMP
- Request
22 B0 BB - Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 10 max temperature MG_HVBAT_CMU10_MAXTEMP_V2
- Request
22 B0 BB - Service 22
DID B0BB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 10 max voltage MG_HVBAT_CMU10_MAXVOLT
- Request
22 B0 BB - Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 10 max voltage MG_HVBAT_CMU10_MAXVOLT_V2
- Request
22 B0 BB - Service 22
DID B0BB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 10 min temperature MG_HVBAT_CMU10_MINTEMP
- Request
22 B0 BB - Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 10 min temperature MG_HVBAT_CMU10_MINTEMP_V2
- Request
22 B0 BB - Service 22
DID B0BB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 10 min voltage MG_HVBAT_CMU10_MINVOLT
- Request
22 B0 BB - Service 22
DID B0BB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 10 min voltage MG_HVBAT_CMU10_MINVOLT_V2
- Request
22 B0 BB - Service 22
DID B0BB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 11
HV battery module 11 max temperature MG_HVBAT_CMU11_MAXTEMP
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 11 max temperature MG_HVBAT_CMU11_MAXTEMP_V2
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 11 max voltage MG_HVBAT_CMU11_MAXVOLT
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 11 max voltage MG_HVBAT_CMU11_MAXVOLT_V2
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 11 min temperature MG_HVBAT_CMU11_MINTEMP
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 11 min temperature MG_HVBAT_CMU11_MINTEMP_V2
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 11 min voltage MG_HVBAT_CMU11_MINVOLT
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 11 min voltage MG_HVBAT_CMU11_MINVOLT_V2
- Request
22 B0 C3 - Service 22
DID B0C3 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 12
HV battery module 12 max temperature MG_HVBAT_CMU12_MAXTEMP
- Request
22 B0 CB - Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 12 max temperature MG_HVBAT_CMU12_MAXTEMP_V2
- Request
22 B0 CB - Service 22
DID B0CB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 12 max voltage MG_HVBAT_CMU12_MAXVOLT
- Request
22 B0 CB - Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 12 max voltage MG_HVBAT_CMU12_MAXVOLT_V2
- Request
22 B0 CB - Service 22
DID B0CB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 12 min temperature MG_HVBAT_CMU12_MINTEMP
- Request
22 B0 CB - Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 12 min temperature MG_HVBAT_CMU12_MINTEMP_V2
- Request
22 B0 CB - Service 22
DID B0CB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 12 min voltage MG_HVBAT_CMU12_MINVOLT
- Request
22 B0 CB - Service 22
DID B0CB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 12 min voltage MG_HVBAT_CMU12_MINVOLT_V2
- Request
22 B0 CB - Service 22
DID B0CB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 13
HV battery module 13 max temperature MG_HVBAT_CMU13_MAXTEMP
- Request
22 B0 DB - Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 13 max temperature MG_HVBAT_CMU13_MAXTEMP_V2
- Request
22 B0 DB - Service 22
DID B0DB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 13 max voltage MG_HVBAT_CMU13_MAXVOLT
- Request
22 B0 DB - Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 13 max voltage MG_HVBAT_CMU13_MAXVOLT_V2
- Request
22 B0 DB - Service 22
DID B0DB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 13 min temperature MG_HVBAT_CMU13_MINTEMP
- Request
22 B0 DB - Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 13 min temperature MG_HVBAT_CMU13_MINTEMP_V2
- Request
22 B0 DB - Service 22
DID B0DB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 13 min voltage MG_HVBAT_CMU13_MINVOLT
- Request
22 B0 DB - Service 22
DID B0DB - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 13 min voltage MG_HVBAT_CMU13_MINVOLT_V2
- Request
22 B0 DB - Service 22
DID B0DB - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 14
HV battery module 14 max temperature MG_HVBAT_CMU14_MAXTEMP
- Request
22 B0 DC - Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 14 max temperature MG_HVBAT_CMU14_MAXTEMP_V2
- Request
22 B0 DC - Service 22
DID B0DC - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 14 max voltage MG_HVBAT_CMU14_MAXVOLT
- Request
22 B0 DC - Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 14 max voltage MG_HVBAT_CMU14_MAXVOLT_V2
- Request
22 B0 DC - Service 22
DID B0DC - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 14 min temperature MG_HVBAT_CMU14_MINTEMP
- Request
22 B0 DC - Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 14 min temperature MG_HVBAT_CMU14_MINTEMP_V2
- Request
22 B0 DC - Service 22
DID B0DC - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 14 min voltage MG_HVBAT_CMU14_MINVOLT
- Request
22 B0 DC - Service 22
DID B0DC - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 14 min voltage MG_HVBAT_CMU14_MINVOLT_V2
- Request
22 B0 DC - Service 22
DID B0DC - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 15
HV battery module 15 max temperature MG_HVBAT_CMU15_MAXTEMP
- Request
22 B0 DD - Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 15 max temperature MG_HVBAT_CMU15_MAXTEMP_V2
- Request
22 B0 DD - Service 22
DID B0DD - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 15 max voltage MG_HVBAT_CMU15_MAXVOLT
- Request
22 B0 DD - Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 15 max voltage MG_HVBAT_CMU15_MAXVOLT_V2
- Request
22 B0 DD - Service 22
DID B0DD - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 15 min temperature MG_HVBAT_CMU15_MINTEMP
- Request
22 B0 DD - Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 15 min temperature MG_HVBAT_CMU15_MINTEMP_V2
- Request
22 B0 DD - Service 22
DID B0DD - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 15 min voltage MG_HVBAT_CMU15_MINVOLT
- Request
22 B0 DD - Service 22
DID B0DD - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 15 min voltage MG_HVBAT_CMU15_MINVOLT_V2
- Request
22 B0 DD - Service 22
DID B0DD - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 16
HV battery module 16 max temperature MG_HVBAT_CMU16_MAXTEMP
- Request
22 B0 DE - Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 16 max temperature MG_HVBAT_CMU16_MAXTEMP_V2
- Request
22 B0 DE - Service 22
DID B0DE - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 16 max voltage MG_HVBAT_CMU16_MAXVOLT
- Request
22 B0 DE - Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 16 max voltage MG_HVBAT_CMU16_MAXVOLT_V2
- Request
22 B0 DE - Service 22
DID B0DE - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 16 min temperature MG_HVBAT_CMU16_MINTEMP
- Request
22 B0 DE - Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 16 min temperature MG_HVBAT_CMU16_MINTEMP_V2
- Request
22 B0 DE - Service 22
DID B0DE - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 16 min voltage MG_HVBAT_CMU16_MINVOLT
- Request
22 B0 DE - Service 22
DID B0DE - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 16 min voltage MG_HVBAT_CMU16_MINVOLT_V2
- Request
22 B0 DE - Service 22
DID B0DE - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 17
HV battery module 17 max temperature MG_HVBAT_CMU17_MAXTEMP
- Request
22 B1 0E - Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 17 max temperature MG_HVBAT_CMU17_MAXTEMP_V2
- Request
22 B1 0E - Service 22
DID B10E - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 17 max voltage MG_HVBAT_CMU17_MAXVOLT
- Request
22 B1 0E - Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 17 max voltage MG_HVBAT_CMU17_MAXVOLT_V2
- Request
22 B1 0E - Service 22
DID B10E - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 17 min temperature MG_HVBAT_CMU17_MINTEMP
- Request
22 B1 0E - Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 17 min temperature MG_HVBAT_CMU17_MINTEMP_V2
- Request
22 B1 0E - Service 22
DID B10E - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 17 min voltage MG_HVBAT_CMU17_MINVOLT
- Request
22 B1 0E - Service 22
DID B10E - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 17 min voltage MG_HVBAT_CMU17_MINVOLT_V2
- Request
22 B1 0E - Service 22
DID B10E - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 18
HV battery module 18 max temperature MG_HVBAT_CMU18_MAXTEMP
- Request
22 B1 0F - Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 18 max temperature MG_HVBAT_CMU18_MAXTEMP_V2
- Request
22 B1 0F - Service 22
DID B10F - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 18 max voltage MG_HVBAT_CMU18_MAXVOLT
- Request
22 B1 0F - Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 18 max voltage MG_HVBAT_CMU18_MAXVOLT_V2
- Request
22 B1 0F - Service 22
DID B10F - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 18 min temperature MG_HVBAT_CMU18_MINTEMP
- Request
22 B1 0F - Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 18 min temperature MG_HVBAT_CMU18_MINTEMP_V2
- Request
22 B1 0F - Service 22
DID B10F - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 18 min voltage MG_HVBAT_CMU18_MINVOLT
- Request
22 B1 0F - Service 22
DID B10F - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 18 min voltage MG_HVBAT_CMU18_MINVOLT_V2
- Request
22 B1 0F - Service 22
DID B10F - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 19
HV battery module 19 max temperature MG_HVBAT_CMU19_MAXTEMP
- Request
22 B1 10 - Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 19 max temperature MG_HVBAT_CMU19_MAXTEMP_V2
- Request
22 B1 10 - Service 22
DID B110 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 19 max voltage MG_HVBAT_CMU19_MAXVOLT
- Request
22 B1 10 - Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 19 max voltage MG_HVBAT_CMU19_MAXVOLT_V2
- Request
22 B1 10 - Service 22
DID B110 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 19 min temperature MG_HVBAT_CMU19_MINTEMP
- Request
22 B1 10 - Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 19 min temperature MG_HVBAT_CMU19_MINTEMP_V2
- Request
22 B1 10 - Service 22
DID B110 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 19 min voltage MG_HVBAT_CMU19_MINVOLT
- Request
22 B1 10 - Service 22
DID B110 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 19 min voltage MG_HVBAT_CMU19_MINVOLT_V2
- Request
22 B1 10 - Service 22
DID B110 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 20
HV battery module 20 max temperature MG_HVBAT_CMU20_MAXTEMP
- Request
22 B1 11 - Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 20 max temperature MG_HVBAT_CMU20_MAXTEMP_V2
- Request
22 B1 11 - Service 22
DID B111 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 20 max voltage MG_HVBAT_CMU20_MAXVOLT
- Request
22 B1 11 - Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 20 max voltage MG_HVBAT_CMU20_MAXVOLT_V2
- Request
22 B1 11 - Service 22
DID B111 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 20 min temperature MG_HVBAT_CMU20_MINTEMP
- Request
22 B1 11 - Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 20 min temperature MG_HVBAT_CMU20_MINTEMP_V2
- Request
22 B1 11 - Service 22
DID B111 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 20 min voltage MG_HVBAT_CMU20_MINVOLT
- Request
22 B1 11 - Service 22
DID B111 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 20 min voltage MG_HVBAT_CMU20_MINVOLT_V2
- Request
22 B1 11 - Service 22
DID B111 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 21
HV battery module 21 max temperature MG_HVBAT_CMU21_MAXTEMP
- Request
22 B1 12 - Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 21 max temperature MG_HVBAT_CMU21_MAXTEMP_V2
- Request
22 B1 12 - Service 22
DID B112 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 21 max voltage MG_HVBAT_CMU21_MAXVOLT
- Request
22 B1 12 - Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 21 max voltage MG_HVBAT_CMU21_MAXVOLT_V2
- Request
22 B1 12 - Service 22
DID B112 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 21 min temperature MG_HVBAT_CMU21_MINTEMP
- Request
22 B1 12 - Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 21 min temperature MG_HVBAT_CMU21_MINTEMP_V2
- Request
22 B1 12 - Service 22
DID B112 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 21 min voltage MG_HVBAT_CMU21_MINVOLT
- Request
22 B1 12 - Service 22
DID B112 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 21 min voltage MG_HVBAT_CMU21_MINVOLT_V2
- Request
22 B1 12 - Service 22
DID B112 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 22
HV battery module 22 max temperature MG_HVBAT_CMU22_MAXTEMP
- Request
22 B1 13 - Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 22 max temperature MG_HVBAT_CMU22_MAXTEMP_V2
- Request
22 B1 13 - Service 22
DID B113 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 22 max voltage MG_HVBAT_CMU22_MAXVOLT
- Request
22 B1 13 - Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 22 max voltage MG_HVBAT_CMU22_MAXVOLT_V2
- Request
22 B1 13 - Service 22
DID B113 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 22 min temperature MG_HVBAT_CMU22_MINTEMP
- Request
22 B1 13 - Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 22 min temperature MG_HVBAT_CMU22_MINTEMP_V2
- Request
22 B1 13 - Service 22
DID B113 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 22 min voltage MG_HVBAT_CMU22_MINVOLT
- Request
22 B1 13 - Service 22
DID B113 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 22 min voltage MG_HVBAT_CMU22_MINVOLT_V2
- Request
22 B1 13 - Service 22
DID B113 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 23
HV battery module 23 max temperature MG_HVBAT_CMU23_MAXTEMP
- Request
22 B1 14 - Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 23 max temperature MG_HVBAT_CMU23_MAXTEMP_V2
- Request
22 B1 14 - Service 22
DID B114 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 23 max voltage MG_HVBAT_CMU23_MAXVOLT
- Request
22 B1 14 - Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 23 max voltage MG_HVBAT_CMU23_MAXVOLT_V2
- Request
22 B1 14 - Service 22
DID B114 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 23 min temperature MG_HVBAT_CMU23_MINTEMP
- Request
22 B1 14 - Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 23 min temperature MG_HVBAT_CMU23_MINTEMP_V2
- Request
22 B1 14 - Service 22
DID B114 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 23 min voltage MG_HVBAT_CMU23_MINVOLT
- Request
22 B1 14 - Service 22
DID B114 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 23 min voltage MG_HVBAT_CMU23_MINVOLT_V2
- Request
22 B1 14 - Service 22
DID B114 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
Battery › Modules › 24
HV battery module 24 max temperature MG_HVBAT_CMU24_MAXTEMP
- Request
22 B1 15 - Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 24 max temperature MG_HVBAT_CMU24_MAXTEMP_V2
- Request
22 B1 15 - Service 22
DID B115 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 24 max voltage MG_HVBAT_CMU24_MAXVOLT
- Request
22 B1 15 - Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 24 max voltage MG_HVBAT_CMU24_MAXVOLT_V2
- Request
22 B1 15 - Service 22
DID B115 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 24 min temperature MG_HVBAT_CMU24_MINTEMP
- Request
22 B1 15 - Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- 0 to 87.5 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 24 min temperature MG_HVBAT_CMU24_MINTEMP_V2
- Request
22 B1 15 - Service 22
DID B115 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.5 − 40)- Range
- 0 to 150 °C
- Unit
- °C
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 24 min voltage MG_HVBAT_CMU24_MINVOLT
- Request
22 B1 15 - Service 22
DID B115 - Module
7DF → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2000 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.
HV battery module 24 min voltage MG_HVBAT_CMU24_MINVOLT_V2
- Request
22 B1 15 - Service 22
DID B115 - Module
7E5 → 7ED - Every
180 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.0005 + 1)- Range
- 0 to 10 V
- Unit
- V
In testing for 2019 to 2022, 2024 to 2026. Not supported for 2023.