Battery parameters
The Mercedes-Benz A 220 has 7 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V system voltage, hd MERCEDES_AUX_V_HD
Pelican can show this parameter as the starter battery voltage.
- Request
22 02 01 - Service 22
DID 0201 - Module
624 → 5A4 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val × 1000 ÷ 10000)- Range
- 0 to 100 V
- Unit
- V
In testing for 2018 to 2020, 2022 to 2026. Not supported for 2021.
Auxiliary battery voltage MERCEDES_AUX_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 20 05 - Service 22
DID 2005 - Module
7E5 - Every
1 s - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 0 to 7 of the reply, 8 bits.
0x7B = 123 → (123 × 25.9 ÷ 255) = 12.492941 V
- Formula
(val × 25.9 ÷ 255)- Range
- 0 to 25.9 V
- Unit
- V
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
DC converter requested voltage MERCEDES_CNVRTR_REQ_VConfirmed
- Request
22 60 71 - Service 22
DID 6071 - Module
7E5 - Every
1 s - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 0 to 15 of the reply, 16 bits.
0x05A0 = 1440 → (1440 × 250 ÷ 10000) = 36 V
- Formula
(val × 250 ÷ 10000)- Range
- 0 to 100 V
- Unit
- V
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
HV battery amperage MERCEDES_HV_AConfirmed
- Request
22 60 53 - Service 22
DID 6053 - Module
7E5 - Every
1 s - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 0 to 15 of the reply, 16 bits. The value is signed.
0x0000 = 0 → (0 ÷ 10) = 0 A
- Formula
(val ÷ 10)- Range
- 0 to 100 A
- Unit
- A
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
HV battery coolant temperature MERCEDES_HV_COOLANT_T
- Request
22 25 26 - Service 22
DID 2526 - Module
7E5 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 1250 ÷ 10000)- Range
- 0 to 100 °C
- Unit
- °C
In testing for 2018 to 2020, 2022 to 2026. Not supported for 2021.
HV battery state of charge MERCEDES_HV_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 60 50 - Service 22
DID 6050 - Module
7E5 - Every
1 s - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 0 to 15 of the reply, 16 bits.
0x1068 = 4200 → (4200 ÷ 100) = 42 %
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.
HV battery voltage MERCEDES_HV_VConfirmed
- Request
22 60 75 - Service 22
DID 6075 - Module
7E5 - Every
1 s - Testing
Example reply from a 2021 Mercedes-Benz A 220.
Bits 0 to 15 of the reply, 16 bits.
0x0000 = 0 → (0 × 25 ÷ 1000) = 0 V
- Formula
(val × 25 ÷ 1000)- Range
- 0 to 100 V
- Unit
- V
Confirmed for 2021. In testing for 2018 to 2020, 2022 to 2026.