Fuel parameters
The Mazda CX-3 has 17 fuel parameters.
● Confirmed◆ In testing○ Supported× Not supported
Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2021.
Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed
Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2021.
Fuel level CX3_FLVConfirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 61 B1 - Service 22
DID 61B1 - Module
720 → 728 - Every
1 s - Testing for 2016, 2018, 2020 to 2026
Example reply from a 2019 Mazda CX-3.
Bits 0 to 7 of the reply, 8 bits.
0x05 = 5 → 5 L
- Formula
val- Range
- 0 to 255 L
- Unit
- L
Confirmed for 2015, 2017, 2019. In testing for 2016, 2020, 2022 to 2026. Not supported for 2018, 2021.
Fuel pump load CX3_FP_LDConfirmed
- Request
22 03 07 - Service 22
DID 0307 - Module
7E0 → 7E8 - Every
250 ms - Testing for 2016, 2020, 2022 to 2026
Example reply from a 2021 Mazda CX-3.
Bits 0 to 15 of the reply, 16 bits.
0x4A2D = 18989 → (18989 × 100 ÷ 65535) = 28.975357 %
- Formula
(val × 100 ÷ 65535)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2015, 2017 to 2019, 2021. In testing for 2016, 2020, 2022 to 2026.
Fuel Rail Pressure A FRP_ASAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2021.
Fuel Rail Pressure B FRP_BSAE J1979Confirmed
Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 kPa
- Unit
- kPa
Confirmed for 2021.
Fuel Rail Temperature A FRT_ASAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021.
Fuel Rail Temperature B FRT_BSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2021.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2021. Supported for 2015 to 2020.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2021. Supported for 2015 to 2020.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
01 2F - Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017, 2021. Supported for 2015 to 2016, 2018 to 2020.
Fuel › Internal
Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021.
Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021.
Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021.
Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021.
Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021.
Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed
- Request
01 6D - Service 01
PID 6D - Module
7E0 → 7E8 - Every
250 ms
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2021.