LINCOLN_EVAP parameters
The Lincoln Navigator has 1 LINCOLN_EVAP parameter.
● Confirmed◆ In testing○ Supported× Not supported
Evaporative vapor pressure sensor voltage LINCOLN_EVAP_V
- Request
22 03 8E - Service 22
DID 038E - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.1998046869)- Range
- 0 to 5 V
- Unit
- V
In testing for 1998 to 2026.