Lincoln MKZ

LINCOLN_TIP parameters

The Lincoln MKZ has 2 LINCOLN_TIP parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Throttle inlet pressure absolute LINCOLN_TIP_ABSConfirmed

  • Request22 03 3E
  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

0x33EC = 13292 → (13292 × 0.0011064263) = 14.706618 psi

Formula
(val × 0.0011064263)
Range
0 to 60 psi
Unit
psi

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Throttle inlet pressure absolute LINCOLN_TIP_ABSConfirmed

  • Request22 03 3E
  • Service 22DID 033E
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

0x33EC = 13292 → (13292 × 0.0011064263) = 14.706618 psi

Formula
(val × 0.0011064263)
Range
0 to 60 psi
Unit
psi

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.

Throttle inlet pressure sensor voltage LINCOLN_TIP_VConfirmed

  • Request22 03 3C
  • Service 22DID 033C
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Example reply from a 2013 Lincoln MKZ.

Bits 0 to 15 of the reply, 16 bits.

0x014E = 334 → (334 × 0.0048828125) = 1.630859 V

Formula
(val × 0.0048828125)
Range
0 to 5 V
Unit
V

Confirmed for 2013. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012.