Battery parameters
The Lincoln MKZ has 117 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery age LINCOLN_12V_AGE
- Request
22 40 27 - Service 22
DID 4027 - Module
726 → 72E - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 24)- Range
- 0 to 1572840 h
- Unit
- h
In testing for 2006 to 2020.
12V battery current LINCOLN_VEH_BAT_CURRENT
- Request
22 40 2B - Service 22
DID 402B - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 127)- Range
- -127 to 128 A
- Unit
- A
In testing for 2006 to 2020.
12V battery state of charge LINCOLN_12V_SOC
- Request
22 40 28 - Service 22
DID 4028 - Module
726 → 72E - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2006 to 2020.
12V battery voltage LINCOLN_VEH_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 40 2A - Service 22
DID 402A - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 20 + 6)- Range
- 0 to 18.75 V
- Unit
- V
In testing for 2006 to 2020.
Aux 12V battery control mode LINCOLN_AUX_12V_BAT_CTRL
- Request
22 40 D1 - Service 22
DID 40D1 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2006 to 2020.
Average battery module voltage LINCOLN_AVG_BAT_MODULE_V
- Request
22 48 41 - Service 22
DID 4841 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2006 to 2020.
Battery age LINCOLN_BATT_AGE
- Request
22 40 27 - Service 22
DID 4027 - Module
726 → 72E - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 1825
- Unit
- Number
In testing for 2006 to 2020.
Battery capacity LINCOLN_BAT_CAP
- Request
22 48 5C - Service 22
DID 485C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 Ah
- Unit
- Ah
In testing for 2006 to 2020.
Battery capacity too low for start/stop LINCOLN_BAT_CAP_TOO_LOW
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2006 to 2020.
Battery charge LINCOLN_BATT_SOC
- Request
22 40 28 - Service 22
DID 4028 - Module
726 → 72E - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2006 to 2020.
Battery current too high for start/stop LINCOLN_BAT_CURRENT_TOO_HIGH
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2006 to 2020.
Battery current, predicted LINCOLN_BAT_CURRENT
- Request
22 42 09 - Service 22
DID 4209 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 4)- Range
- 0 to 4194303.75 A
- Unit
- A
In testing for 2006 to 2020.
Battery discharge power limit LINCOLN_BAT_DCHG_POWER_LIM
- Request
22 48 52 - Service 22
DID 4852 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kW
- Unit
- kW
In testing for 2006 to 2020.
Battery pack lifetime charge out, throughput LINCOLN_BAT_PACK_LIFETIME
- Request
22 48 5D - Service 22
DID 485D - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 Ah
- Unit
- Ah
In testing for 2006 to 2020.
Battery percentage, state of charge LINCOLN_BAT_PERCENTAGE_ST
- Request
22 40 28 - Service 22
DID 4028 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2006 to 2020.
Battery quiescent current, low range LINCOLN_BAT_QUIESCENT
- Request
22 40 25 - Service 22
DID 4025 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 1000)- Range
- -1000 to 31767.5 mA
- Unit
- mA
In testing for 2006 to 2020.
Battery refresh cycle in progress for start/stop LINCOLN_BAT_REFRESH_CYCLE
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2006 to 2020.
Battery state detection status LINCOLN_BAT_ST_DETECTION
- Request
22 42 0A - Service 22
DID 420A - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2006 to 2020.
Battery state of charge too low for start/stop LINCOLN_BAT_ST_CHG_TOO_LOW
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2006 to 2020.
Battery temperature LINCOLN_BATT_TEMP
- Request
22 40 29 - Service 22
DID 4029 - Module
726 → 72E - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 100 °C
- Unit
- °C
In testing for 2006 to 2020.
Battery temperature too low for auto stop LINCOLN_BAT_T_TOO_LOW_AUTO
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2006 to 2020.
Battery voltage LINCOLN_BAT_V
- Request
22 11 72 - Service 22
DID 1172 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 16)- Range
- 0 to 15.9375 V
- Unit
- V
In testing for 2006 to 2020.
Battery voltage too low for auto restart LINCOLN_BAT_V_TOO_LOW_AUTO
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 12 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2006 to 2020.
Battery voltage too low for cold cranking capability LINCOLN_BAT_V_TOO_LOW_COLD
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2006 to 2020.
Battery voltage too low for start/stop LINCOLN_BAT_V_TOO_LOW_START
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2006 to 2020.
Charge air cooler temperature LINCOLN_CHG_AIR_COOLER_T
- Request
22 05 08 - Service 22
DID 0508 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 8)- Range
- 0 to 524280
- Unit
- Raw value
In testing for 2006 to 2020.
Charge air temperature LINCOLN_CHG_AIR_T
- Request
22 05 1C - Service 22
DID 051C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2006 to 2020.
Charger digital mode LINCOLN_EVSE_DIGITAL_MODE
- Request
22 48 B7 - Service 22
DID 48B7 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | DC_E_MINUS | DC E- |
2 | DC_MINUS_P | DC -P |
3 | DC_EP | DC EP |
4 | AC_E_MINUS | AC E- |
5 | AC_MINUS_P | AC -P |
6 | AC_EP | AC EP |
7 | RESET | Reset |
8 | OFF | Off |
9 | ESTABLISH | Establish |
10 | FAULT | Fault |
In testing for 2006 to 2020.
Charger type LINCOLN_EVSE_TYPE
- Request
22 48 51 - Service 22
DID 4851 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NONE | None |
1 | LEVEL_1 | Level 1 |
2 | LEVEL_2 | Level 2 |
3 | DC | |
4 | BASIC | Basic |
5 | HIGH_LEVEL | High Level |
6 | BASIC_AC | Basic AC |
7 | HIGH_LEVEL_AC | High Level AC |
8 | HIGH_LEVEL_DC | High Level DC |
10 | NO_COMM | No communication |
11 | FAULT | Fault |
12 | HANDSHAKE_END | Handshake end |
In testing for 2006 to 2020.
Charging state LINCOLN_CHRG_STATE
Pelican can show this parameter as the charging state.
- Request
22 48 4F - Service 22
DID 484F - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NOT_READY | Not ready |
1 | READY | Ready |
2 | FAULT | Fault |
3 | WAIT | Wait Check |
4 | PRE_COND | Pre-condition |
5 | CHARGING | Charging |
6 | DONE | Done |
7 | EXT | External Charger |
8 | INIT | Initializing |
In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.
Commanded generator voltage LINCOLN_CMD_GEN_V
- Request
22 03 04 - Service 22
DID 0304 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000488)- Range
- 0 to 16 V
- Unit
- V
In testing for 2006 to 2020.
Contactor voltage negative LINCOLN_CONTACTOR_V_NEG
- Request
22 48 06 - Service 22
DID 4806 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 300 V
- Unit
- V
In testing for 2006 to 2020.
Contactor voltage negative LINCOLN_CONTACTOR_V_NEGATIVE
- Request
22 48 06 - Service 22
DID 4806 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.34 V
- Unit
- V
In testing for 2006 to 2020.
Contactor voltage positive LINCOLN_CONTACTOR_V_POS
- Request
22 48 05 - Service 22
DID 4805 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 300 V
- Unit
- V
In testing for 2006 to 2020.
Contactor voltage positive LINCOLN_CONTACTOR_V_POSITIVE
- Request
22 48 05 - Service 22
DID 4805 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.34 V
- Unit
- V
In testing for 2006 to 2020.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2013. Supported for 2012, 2020.
DC-DC converter LINCOLN_DCDC_ENABLED
- Request
22 48 3D - Service 22
DID 483D - Module
746 → 74E - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2006 to 2020.
High voltage AC charger coupler temperature LINCOLN_HIGH_V_AC_CHARGER_T
- Request
22 48 88 - Service 22
DID 4888 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 40)- Range
- -40 to 419 °F
- Unit
- °F
In testing for 2006 to 2020.
High voltage AC charger coupler temperature LINCOLN_HIGH_V_AC_CHARGER_T_V2
- Request
22 D1 17 - Service 22
DID D117 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 40)- Range
- -40 to 419 °F
- Unit
- °F
In testing for 2006 to 2020.
High voltage battery intake air temperature LINCOLN_HVBAT_IAT
- Request
22 00 0F - Service 22
DID 000F - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 39.8)- Range
- -39.8 to 419 °F
- Unit
- °F
In testing for 2006 to 2020.
High voltage charger current, requested LINCOLN_HIGH_V_CHARGER
- Request
22 48 42 - Service 22
DID 4842 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
In testing for 2006 to 2020.
High voltage charger input power available, raw count LINCOLN_HIGH_V_CHARGER_INPUT
- Request
22 48 4E - Service 22
DID 484E - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2006 to 2020.
High voltage charger output current measured LINCOLN_HIGH_V_CHARGER_OUTPUT
- Request
22 48 50 - Service 22
DID 4850 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
In testing for 2006 to 2020.
High voltage charger output reduction temperature LINCOLN_HIGH_V_CHARGER_T
- Request
22 48 A5 - Service 22
DID 48A5 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2006 to 2020.
High voltage charger output voltage, raw count LINCOLN_HIGH_V_CHARGER_V
- Request
22 48 4A - Service 22
DID 484A - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2006 to 2020.
High voltage charger pilot voltage LINCOLN_HIGH_V_CHARGER_PILOT_V
- Request
22 48 B6 - Service 22
DID 48B6 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2006 to 2020.
High voltage charger pilot voltage, raw count LINCOLN_HIGH_V_CHARGER_PILOT_V_RAW
- Request
22 48 BC - Service 22
DID 48BC - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2006 to 2020.
High voltage charger status LINCOLN_HIGH_V_CHARGER_STAT
- Request
22 48 4D - Service 22
DID 484D - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2006 to 2020.
High voltage charger status LINCOLN_HIGH_V_CHARGER_STAT_7E2
- Request
22 48 4F - Service 22
DID 484F - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2006 to 2020.
High voltage charger voltage, requested LINCOLN_HIGH_V_CHARGER_V_REQ
- Request
22 48 44 - Service 22
DID 4844 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 510 V
- Unit
- V
In testing for 2006 to 2020.
High voltage charger, maximum power LINCOLN_HIGH_V_CHARGER_MAX
- Request
22 48 C4 - Service 22
DID 48C4 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 kW
- Unit
- kW
In testing for 2006 to 2020.
High voltage DC charger coupler temperature LINCOLN_HIGH_V_DC_CHARGER_T
- Request
22 D0 0C - Service 22
DID D00C - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 40)- Range
- -40 to 419 °F
- Unit
- °F
In testing for 2006 to 2020.
High voltage DC charger coupler temperature 1 LINCOLN_HIGH_V_DC_CHARGER_T_1
- Request
22 48 97 - Service 22
DID 4897 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 40)- Range
- -40 to 419 °F
- Unit
- °F
In testing for 2006 to 2020.
High voltage DC charger coupler temperature 3 LINCOLN_HIGH_V_DC_CHARGER_T_3
- Request
22 48 A4 - Service 22
DID 48A4 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 40)- Range
- -40 to 419 °F
- Unit
- °F
In testing for 2006 to 2020.
High voltage DC charger status LINCOLN_HIGH_V_DC_CHARGER
- Request
22 48 9E - Service 22
DID 489E - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2006 to 2020.
High-voltage battery current LINCOLN_HVB_CURRENT
- Request
22 48 F9 - Service 22
DID 48F9 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 A
- Unit
- A
In testing for 2006 to 2020.
HV AC charger coupler temperature LINCOLN_AC_CHG_COUPLER_T
- Request
22 48 88 - Service 22
DID 4888 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2006 to 2020.
HV AC charger input current LINCOLN_AC_CHG_IN_A
- Request
22 48 5F - Service 22
DID 485F - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 A
- Unit
- A
In testing for 2006 to 2020.
HV AC charger input frequency LINCOLN_AC_CHG_IN_FREQ
- Request
22 48 60 - Service 22
DID 4860 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 30 to 90 Hz
- Unit
- Hz
In testing for 2006 to 2020.
HV AC charger input voltage LINCOLN_AC_CHG_IN_V
- Request
22 48 5E - Service 22
DID 485E - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 V
- Unit
- V
In testing for 2006 to 2020.
HV battery age LINCOLN_HVBAT_AGEConfirmed
- Request
22 48 10 - Service 22
DID 4810 - Module
7E4 → 7EC - Every
5 s - Testing
Example reply from a 2012 Lincoln MKZ.
Bits 0 to 15 of the reply, 16 bits.
0x886F = 34927 → (34927 × 720 ÷ 200) = 125,737.2 h
- Formula
(val × 720 ÷ 200)- Range
- 0 to 235926 h
- Unit
- h
Confirmed for 2012. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2013.
HV battery average module voltage LINCOLN_HVBAT_AVG_MOD_V
- Request
22 48 41 - Service 22
DID 4841 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 50 V
- Unit
- V
In testing for 2006 to 2020.
HV battery charge LINCOLN_HVBAT_SOCConfirmed
High resolution state of charge.
Pelican can show this parameter as the state of charge.
- Request
22 48 01 - Service 22
DID 4801 - Module
7E4 → 7EC - Every
1 s - Testing
Example reply from a 2012 Lincoln MKZ.
Bits 0 to 15 of the reply, 16 bits.
0x4280 = 17024 → (17024 ÷ 500) = 34.048 %
- Formula
(val ÷ 500)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2012. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2013.
HV battery charge (displayed) LINCOLN_HVBAT_SOC_DISP
The state of charge displayed on the vehicle's dashboard.
Pelican can show this parameter as the state of charge.
- Request
22 48 45 - Service 22
DID 4845 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.
HV battery charge current requested LINCOLN_HVBAT_CCR
- Request
22 48 42 - Service 22
DID 4842 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 600 A
- Unit
- A
In testing for 2006 to 2020.
HV battery charge power limit LINCOLN_HVBAT_CHG_PWR_LIM
- Request
22 48 FB - Service 22
DID 48FB - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 300 kW
- Unit
- kW
In testing for 2006 to 2020.
HV battery charge voltage requested LINCOLN_HVBAT_CVR
- Request
22 48 44 - Service 22
DID 4844 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 2)- Range
- 0 to 500 V
- Unit
- V
In testing for 2006 to 2020.
HV battery charging status LINCOLN_HVBAT_CHG_STATUS
- Request
22 48 4D - Service 22
DID 484D - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NOT_READY | Not ready |
1 | WAIT | Wait |
2 | READY | Ready |
3 | CHARGING | Charging |
4 | DONE | Done |
5 | FAULT | Fault |
In testing for 2006 to 2020.
HV battery coolant inlet temperature LINCOLN_HVBAT_COOLANT_INLET_T
- Request
22 48 46 - Service 22
DID 4846 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2006 to 2020.
HV battery current LINCOLN_HVBAT_A
Pelican can show this parameter as the traction battery current.
- Request
22 48 F9 - Service 22
DID 48F9 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -600 to 600 A
- Unit
- A
In testing for 2006 to 2020.
HV battery current high range LINCOLN_HVBAT_CHR_A
- Request
22 48 09 - Service 22
DID 4809 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 A
- Unit
- A
In testing for 2006 to 2020.
HV battery current, alternate LINCOLN_HVBAT_A_ALT
- Request
22 48 0B - Service 22
DID 480B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -300 to 300 A
- Unit
- A
In testing for 2006 to 2020.
HV battery energy LINCOLN_HVBAT_KWH
- Request
22 48 48 - Service 22
DID 4848 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 500)- Range
- 0 to 131.07 kWh
- Unit
- kWh
In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.
HV battery maximum charge current LINCOLN_HVBAT_MAX_CHG_A
- Request
22 48 BC - Service 22
DID 48BC - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 15 A
- Unit
- A
In testing for 2006 to 2020.
HV battery minimum module voltage LINCOLN_HVBAT_MIN_MOD_V
- Request
22 48 40 - Service 22
DID 4840 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2006 to 2020.
HV battery modules voltage LINCOLN_HVBAT_MOD_V
- Request
22 48 3F - Service 22
DID 483F - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2006 to 2020.
HV battery state of health LINCOLN_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Request
22 49 0C - Service 22
DID 490C - Module
7E4 → 7EC - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2006 to 2011, 2014 to 2020. Not supported for 2012 to 2013.
HV battery temperature LINCOLN_HVBAT_TConfirmed
- Request
22 48 00 - Service 22
DID 4800 - Module
7E4 → 7EC - Every
10 s - Testing
Example reply from a 2012 Lincoln MKZ.
Bits 0 to 7 of the reply, 8 bits.
0x49 = 73 → (73 − 50) = 23 °C
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
Confirmed for 2012. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2013.
HV battery temperature range LINCOLN_T_RANGE
- Request
22 48 08 - Service 22
DID 4808 - Module
7E4 → 7EC - Every
15 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2006 to 2020.
HV battery temperature range, average LINCOLN_T_RANGE_AVG
- Request
22 48 08 - Service 22
DID 4808 - Module
7E4 → 7EC - Every
15 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2006 to 2020.
HV battery temperature range, maximum LINCOLN_T_RANGE_MAX
- Request
22 48 08 - Service 22
DID 4808 - Module
7E4 → 7EC - Every
15 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2006 to 2020.
HV battery temperature range, minimum LINCOLN_T_RANGE_MIN
- Request
22 48 08 - Service 22
DID 4808 - Module
7E4 → 7EC - Every
15 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2006 to 2020.
HV battery thermal operation mode LINCOLN_HVBAT_THERMAL_OP_MODE
- Request
22 48 E0 - Service 22
DID 48E0 - Module
7E6 → 7EE - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Off |
1 | EQUALIZE | Equalize |
2 | COOLANT_FLOW | Coolant flow |
3 | COOLANT_FAN | Coolant fan |
4 | COOLANT_MODERATE | Coolant moderate |
5 | COOLANT_MAX | Coolant maximum |
15 | HEAT | Heat |
In testing for 2006 to 2020.
HV battery voltage LINCOLN_HVBAT_VConfirmed
- Request
22 48 0D - Service 22
DID 480D - Module
7E4 → 7EC - Every
1 s - Testing
Example reply from a 2012 Lincoln MKZ.
Bits 0 to 15 of the reply, 16 bits.
0x5BF1 = 23537 → (23537 ÷ 100) = 235.37 V
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
Confirmed for 2012. In testing for 2006 to 2011, 2014 to 2020. Not supported for 2013.
HV battery voltage, raw count LINCOLN_HVB_V_RAW_CNT
- Request
22 48 0D - Service 22
DID 480D - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2006 to 2020.
HV charger input power available LINCOLN_CHG_PWR_AVAIL
- Request
22 48 4E - Service 22
DID 484E - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327.675 kW
- Unit
- kW
In testing for 2006 to 2020.
HV charger maximum power LINCOLN_CHG_MAX_PWR
- Request
22 48 C4 - Service 22
DID 48C4 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 500 kW
- Unit
- kW
In testing for 2006 to 2020.
HV charger output current measured LINCOLN_CHG_OUT_A
- Request
22 48 50 - Service 22
DID 4850 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 600 A
- Unit
- A
In testing for 2006 to 2020.
HV charger output reduction temperature LINCOLN_CHG_OUT_REDUCT_T
- Request
22 48 A5 - Service 22
DID 48A5 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2006 to 2020.
HV charger output voltage LINCOLN_CHG_OUT_V
- Request
22 48 4A - Service 22
DID 484A - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 600 V
- Unit
- V
In testing for 2006 to 2020.
HV charger pilot duty cycle LINCOLN_CHG_PILOT_DUTY
- Request
22 48 61 - Service 22
DID 4861 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2006 to 2020.
HV charger pilot voltage LINCOLN_CHG_PILOT_V
- Request
22 48 B6 - Service 22
DID 48B6 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 15 V
- Unit
- V
In testing for 2006 to 2020.
HV charger proximity status LINCOLN_CHG_PROX_STATUS
- Request
22 48 62 - Service 22
DID 4862 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Off |
1 | ON_S3 | On S3 |
2 | ON | On |
3 | 10A | 10 A |
4 | 13A | 13 A |
5 | 16A | 16 A |
6 | 20A | 20 A |
7 | FAULT | Fault |
8 | 32A | 32 A |
9 | 63A | 63 A |
16 | DC | |
17 | OPEN | Open |
18 | SHORT | Short |
19 | SHORT_PWR | Short to power |
20 | OUT_OF_RANGE | Out of range |
21 | OPEN_CIRCUIT | Open circuit |
In testing for 2006 to 2020.
HV charger proximity voltage LINCOLN_CHG_PROX_V
- Request
22 48 A0 - Service 22
DID 48A0 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2006 to 2020.
HV DC charger coupler temperature 1 LINCOLN_DC_CHG_COUPLER_T1
- Request
22 48 97 - Service 22
DID 4897 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2006 to 2020.
HV DC charger coupler temperature 3 LINCOLN_DC_CHG_COUPLER_T3
- Request
22 48 A4 - Service 22
DID 48A4 - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2006 to 2020.
HV DC charger maximum current LINCOLN_HVDC_CHG_MAX_C
- Request
22 48 99 - Service 22
DID 4899 - Module
6F5 → 6FD - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 A
- Unit
- A
In testing for 2006 to 2020.
HV DC charger maximum voltage LINCOLN_HVDC_CHG_MAX_V
- Request
22 48 9D - Service 22
DID 489D - Module
6F5 → 6FD - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2006 to 2020.
HV DC charger status LINCOLN_DC_CHG_STATUS
- Request
22 48 9E - Service 22
DID 489E - Module
7E2 → 7EA - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NOT_READY | Not ready |
1 | INIT | Initialize |
2 | READY | Ready |
3 | WAIT_CHECK | Wait check |
4 | PRE_CONDITION | Pre-condition |
5 | CHARGING | Charging |
6 | DONE | Done |
8 | WAIT | Wait |
9 | NOT_CAPABLE | Not capable |
10 | FAULT | Fault |
11 | CHARGER_CHECK | Charger check |
In testing for 2006 to 2020.
HV negative leakage voltage LINCOLN_HV_NEG_LEAK_V
- Request
22 48 04 - Service 22
DID 4804 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2006 to 2020.
HV positive leakage voltage LINCOLN_HV_POS_LEAK_V
- Request
22 48 03 - Service 22
DID 4803 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2006 to 2020.
Hybrid battery pack remaining charge LINCOLN_HYBRID_BAT_PACK
- Request
22 F4 5B - Service 22
DID F45B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2006 to 2020.
Injection control pressure sensor voltage LINCOLN_ICP_V
- Request
22 16 AD - Service 22
DID 16AD - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 51)- Range
- 0 to 5 V
- Unit
- V
In testing for 2006 to 2020.
Low voltage converter input current LINCOLN_DCDC_HV_A
- Request
22 48 3A - Service 22
DID 483A - Module
746 → 74E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25 A
- Unit
- A
In testing for 2006 to 2020.
Low voltage converter output current LINCOLN_DCDC_LV_A
- Request
22 48 36 - Service 22
DID 4836 - Module
746 → 74E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2006 to 2020.
Maximum discharge power limit LINCOLN_MAX_DISCH_PWR_LIM
- Request
22 48 15 - Service 22
DID 4815 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25 ÷ 100)- Range
- 0 to 63.75 kW
- Unit
- kW
In testing for 2006 to 2020.
Minimum battery module voltage LINCOLN_BATT_MIN_BATT_V
- Request
22 48 40 - Service 22
DID 4840 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2006 to 2020.
Normalized cumulative charge when ignition is on LINCOLN_NORM_CUM_CHG_IGN_ON
- Request
22 40 1E - Service 22
DID 401E - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Number
In testing for 2006 to 2020.
Normalized cumulative discharge from battery with engine off LINCOLN_NORM_CUM_DCHG_BAT_OFF
- Request
22 40 26 - Service 22
DID 4026 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Number
In testing for 2006 to 2020.
Normalized cumulative discharge from battery with engine on LINCOLN_NORM_CUM_DCHG_BAT_ON
- Request
22 40 21 - Service 22
DID 4021 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Number
In testing for 2006 to 2020.
PF differential pressure feedback EGR sensor voltage LINCOLN_PF_DIFF_P_FEEDBACK_V
- Request
22 03 E3 - Service 22
DID 03E3 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 977 ÷ 1000000)- Range
- -32.01 to 32.01 V
- Unit
- V
In testing for 2006 to 2020.
Second battery current LINCOLN_VEH_BAT_B_CURRENT
- Request
22 42 3C - Service 22
DID 423C - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.96 A
- Unit
- A
In testing for 2006 to 2020.
Second battery voltage LINCOLN_VEH_BAT_B_V
- Request
22 41 E8 - Service 22
DID 41E8 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 20 + 6)- Range
- 6 to 18.75 V
- Unit
- V
In testing for 2006 to 2020.
State of charge spread across battery modules LINCOLN_HVB_SOC_VARIATION
- Request
22 48 3E - Service 22
DID 483E - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 %
- Unit
- %
In testing for 2006 to 2020.
Target/desired state of charge LINCOLN_TARGET_SOC
- Request
22 05 A1 - Service 22
DID 05A1 - Module
7E4 → 7EC - Every
60 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2006 to 2020.
Traction battery voltage, alternate LINCOLN_TRACTION_BAT_V_ALT
- Request
22 49 0B - Service 22
DID 490B - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 25 ÷ 8192)- Range
- 0 to 199 V
- Unit
- V
In testing for 2006 to 2020.
Voltage spread across battery modules LINCOLN_BAT_V_VARIATION_BAT
- Request
22 48 3F - Service 22
DID 483F - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
In testing for 2006 to 2020.