Battery parameters
The Lexus IS has 26 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
+BM voltage IS_BM_VConfirmed
- Request
21 41 - Service 21
PID 41 - Module
7E0 → 7E8 - Every
3600 s - Testing for 1998 to 2024, 2026
Example reply from a 2025 Lexus IS.
Bits 56 to 71 of the reply, 16 bits.
0x2B6F = 11119 → (11119 × 5 ÷ 4096) = 13.572998 V
- Formula
(val × 5 ÷ 4096)- Range
- 0 to 79.998 V
- Unit
- V
Confirmed for 2025. In testing for 1998 to 2024, 2026.
1st turbocharger outlet pressure, control valve IS_1ST_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 1998 to 2024, 2026. Not supported for 2025.
2nd turbocharger outlet pressure IS_2ND_TRUBOCHARGER_OUTLET_P
- Request
22 11 AF - Service 22
DID 11AF - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 1998 to 2024, 2026. Not supported for 2025.
2nd turbocharger outlet pressure, control valve IS_2ND_TRUBOCHARGER_P
- Request
22 11 CD - Service 22
DID 11CD - Module
700 → 708 - Every
1 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 300 kPa
- Unit
- kPa
In testing for 1998 to 2024, 2026. Not supported for 2025.
Air fuel sensor voltage, bank 1 sensor 1 IS_AFS_VOLTAGE_B1S1Confirmed
- Request
21 04 - Service 21
PID 04 - Module
7E0 → 7E8 - Every
1 s - Testing for 1998 to 2024, 2026
Example reply from a 2025 Lexus IS.
Bits 32 to 47 of the reply, 16 bits.
0x4E19 = 19993 → (19993 × 7.99 ÷ 65535) = 2.437538 V
- Formula
(val × 7.99 ÷ 65535)- Range
- 0 to 7.99 V
- Unit
- V
Confirmed for 2025. In testing for 1998 to 2022, 2024, 2026. Not supported for 2023.
Aux. battery capacity after IG OFF IS_AUX_BAT_CAP_AFTER_IG_OFF
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 1998 to 2024, 2026. Not supported for 2025.
Aux. battery capacity after IG ON IS_AUX_BAT_CAP_AFTER_IG_ON
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 128)- Range
- -128 to 127 Ah
- Unit
- Ah
In testing for 1998 to 2024, 2026. Not supported for 2025.
Battery current IS_BAT_CURRENTConfirmed
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing for 1998 to 2024, 2026
Example reply from a 2025 Lexus IS.
Bits 0 to 15 of the reply, 16 bits.
0x2BA5 = 11173 → (11173 × 50 ÷ 13107 − 125) = -82.377737 A
- Formula
(val × 50 ÷ 13107 − 125)- Range
- -125 to 124.9 A
- Unit
- A
Confirmed for 2025. In testing for 1998 to 2024, 2026.
Battery current IS_BAT_CURRENT_700
- Request
22 15 F7 - Service 22
DID 15F7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 49 ÷ 12850 − 125)- Range
- -125 to 124.9 A
- Unit
- A
In testing for 1998 to 2024, 2026. Not supported for 2025.
Battery status of full charge IS_BAT_STAT_FULL_CHG
- Request
22 15 E5 - Service 22
DID 15E5 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 255 ÷ 2)- Range
- 0 to 32512.5 Ah
- Unit
- Ah
In testing for 1998 to 2024, 2026. Not supported for 2025.
Battery temperature IS_BAT_TConfirmed
- Request
21 42 - Service 21
PID 42 - Module
7E0 → 7E8 - Every
5 s - Testing for 1998 to 2024, 2026
Example reply from a 2025 Lexus IS.
Bits 16 to 31 of the reply, 16 bits.
0x0000 = 0 → 0 °C
- Formula
val- Range
- 0 to 6513.5 °C
- Unit
- °C
Confirmed for 2025. In testing for 1998 to 2024, 2026.
Battery temperature IS_BAT_T_700
- Request
22 15 F8 - Service 22
DID 15F8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 1998 to 2024, 2026. Not supported for 2025.
Battery temperature IS_BAT_T_700_2
- Request
22 1F F8 - Service 22
DID 1FF8 - Module
700 → 708 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 50 − 40)- Range
- -40 to 11756.3 °F
- Unit
- °F
In testing for 1998 to 2024, 2026. Not supported for 2025.
Battery voltage IS_12V_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 10 02 - Service 22
DID 1002 - Module
700 → 708 - Every
5 s - Testing for 1998 to 2024, 2026
Example reply from a 2025 Lexus IS.
Bits 0 to 15 of the reply, 16 bits.
0x2B80 = 11136 → (11136 × 12.207 ÷ 10000) = 13.593715 V
- Formula
(val × 12.207 ÷ 10000)- Range
- 0 to 79 V
- Unit
- V
Confirmed for 2025. In testing for 1998 to 2022, 2024, 2026. Not supported for 2023.
Battery voltage IS_BAT_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
21 13 - Service 21
PID 13 - Module
7C0 → 7C8 - Every
5 s - Testing for 1998 to 2024, 2026
Example reply from a 2025 Lexus IS.
Bits 0 to 7 of the reply, 8 bits.
0x7A = 122 → (122 ÷ 10) = 12.2 V
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2025. In testing for 1998 to 2024, 2026.
Battery voltage IS_BATTERY_VOLTAGEConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 1998 to 2022, 2024, 2026
Example reply from a 2025 Lexus IS.
Bits 200 to 215 of the reply, 16 bits.
0x3183 = 12675 → (12675 ÷ 1000) = 12.675 V
- Formula
(val ÷ 1000)- Range
- 0 to 65.53 V
- Unit
- V
Confirmed for 2023, 2025. In testing for 1998 to 2022, 2024, 2026.
Charging integrated current of aux. battery IS_CHG_INTEGRATED
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 1998 to 2024, 2026. Not supported for 2025.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2009, 2013 to 2014, 2016 to 2017, 2022 to 2023, 2025. Supported for 2015, 2021.
Dark current of battery IS_DARK_CURRENT_BAT
- Request
22 15 E7 - Service 22
DID 15E7 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mA
- Unit
- mA
In testing for 1998 to 2024, 2026. Not supported for 2025.
Discharging integrated current of aux. battery IS_DISCHARGING
- Request
22 15 E8 - Service 22
DID 15E8 - Module
700 → 708 - Every
30 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729.5 Ah
- Unit
- Ah
In testing for 1998 to 2024, 2026. Not supported for 2025.
Distance since last battery cable disconnection IS_DIST_SINCE_BAT_DISCConfirmed
- Request
22 10 6C - Service 22
DID 106C - Module
700 → 708 - Every
30 s - Testing for 1998 to 2024, 2026
Example reply from a 2025 Lexus IS.
Bits 0 to 15 of the reply, 16 bits.
0x3D97 = 15767 → 15,767 km
- Formula
val- Range
- 0 to 65535 km
- Unit
- km
Confirmed for 2025. In testing for 1998 to 2022, 2024, 2026. Not supported for 2023.
Initial engine battery voltage lower limit IS_INITIAL_ENG_BAT_V_LO
- Request
22 15 F6 - Service 22
DID 15F6 - Module
700 → 708 - Every
5 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 1998 to 2024, 2026. Not supported for 2025.
Output speed sensor voltage IS_NOUT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 1998 to 2024, 2026. Not supported for 2025.
Sleep time of battery sensor IS_SLEEP_TIME_BATSENS
- Request
22 15 F0 - Service 22
DID 15F0 - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 h
- Unit
- h
In testing for 1998 to 2024, 2026. Not supported for 2025.
Turbine speed sensor voltage IS_NT_SENS_V
- Request
21 81 - Service 21
PID 81 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 13107)- Range
- 0 to 4.999 V
- Unit
- V
In testing for 1998 to 2024, 2026. Not supported for 2025.
Voltage of battery sensor IS_V_BATSENS
- Request
22 15 EE - Service 22
DID 15EE - Module
700 → 708 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 13333 ÷ 10922500)- Range
- 0 to 79.9979 V
- Unit
- V