Land Rover Defender

Fuel parameters

The Land Rover Defender has 20 fuel parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Commanded Fuel Rail Pressure A FRP_A_CMDConfirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Commanded Fuel Rail Pressure A FRP_A_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 23 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2026.

Commanded Fuel Rail Pressure B FRP_B_CMDSAE J1979Confirmed

Displays commanded fuel rail pressure when the reading is referenced to atmosphere (gage pressure)

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 63 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2026.

Engine exhaust flow rate EXH_RATESAE J1979Confirmed

  • Request01 9E
  • Service 01PID 9E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 13107 kg/h
Unit
kg/h

Confirmed for 2026.

Engine fuel rate FUEL_RATESAE J1979Confirmed

Measured in units per hour

Pelican can show this parameter as the fuel rate.

  • Request01 5E
  • Service 01PID 5E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 3212.75 L/h
Unit
L/h

Confirmed for 2026.

Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed

  • Request01 9D
  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2026.

Fuel rail pressure DEFENDER_FUEL_RAIL_P

  • Request22 16 70
  • Service 22DID 1670
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 78125 ÷ 10000)
Range
0 to 511992.1875 kPa
Unit
kPa

In testing for 1988 to 2016. Not supported for 2020, 2022 to 2026.

Fuel Rail Pressure A FRP_ASAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 39 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2026.

Fuel Rail Pressure B FRP_BSAE J1979Confirmed

Displays fuel rail pressure when the reading is referenced to atmosphere (gage pressure).

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2026.

Fuel rail temperature DEFENDER_FUEL_RAIL_T

  • Request22 16 8E
  • Service 22DID 168E
  • Module7E0
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 48 ÷ 100)
Range
-61.44 to 60.96 °C
Unit
°C

In testing for 1988 to 2016. Not supported for 2020, 2022 to 2026.

Fuel Rail Temperature A FRT_ASAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2026.

Fuel Rail Temperature B FRT_BSAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bits 80 to 87 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2026.

Fuel tank level DEFENDER_FLI

Pelican can show this parameter as the fuel tank level.

  • Request22 16 C1
  • Service 22DID 16C1
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 200 ÷ 65535)
Range
0 to 100 %
Unit
%

In testing for 1988 to 2016. Not supported for 2020, 2022 to 2026.

Fuel tank level FLISAE J1979Confirmed

Pelican can show this parameter as the fuel tank level.

  • Request01 2F
  • Service 01PID 2F
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2020, 2023 to 2026. Supported for 2014, 2022.

Vehicle fuel rate VFUEL_RATESAE J1979Confirmed

  • Request01 9D
  • Service 01PID 9D
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 50)
Range
0 to 1310.7 g/s
Unit
g/s

Confirmed for 2026.

Fuel › Internal

Commanded Fuel Rail Pressure A data supported? FRP_A_CMD_SUPSAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Commanded Fuel Rail Pressure B data supported? FRP_B_CMD_SUPSAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Fuel Rail Pressure A data supported? FRP_A_SUPSAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Fuel Rail Pressure B data supported? FRP_B_SUPSAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Fuel Temperature A data supported? FRT_A_SUPSAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Fuel Temperature B data supported? FRT_B_SUPSAE J1979Confirmed

  • Request01 6D
  • Service 01PID 6D
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.