Fuel parameters
The Kia Seltos has 7 fuel parameters.
● Confirmed◆ In testing○ Supported× Not supported
Engine exhaust flow rate EXH_RATESAE J1979Confirmed
- Request
01 9E - Service 01
PID 9E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kg/h
- Unit
- kg/h
Confirmed for 2022.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2022.
Fuel level SELTOS_FLI_VOLConfirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 B0 02 - Service 22
DID B002 - Module
7C6 → 7CE - Every
5 s - Testing for 2019, 2026
Example reply from a 2025 Kia Seltos.
Bits 32 to 39 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 2) = 0 L
- Formula
(val ÷ 2)- Range
- 0 to 127.5 L
- Unit
- L
Confirmed for 2020 to 2025. In testing for 2019, 2026.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2020 to 2022, 2025. Supported for 2023 to 2024.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2020 to 2022, 2025. Supported for 2023 to 2024.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
01 2F - Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2020 to 2022. Supported for 2025.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s