The Kia K5 has 10 ECU parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Commanded evaporative purge K5_COMMANDED_EVAPORATIVE_PURGE

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
(val × 0.390625)
Range
0 to 99.6 %
Unit
%

In testing for 2000 to 2020. Not supported for 2021 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Commanded evaporative purge K5_COMMANDED_EVAPORATIVE_PURGE

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
(val × 0.390625)
Range
0 to 99.6 %
Unit
%

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Intake camshaft position actual K5_INTAKE_CAMSHAFT_POSITION_ACTUAL

  • Request21 17
  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
-256 to 255 °
Unit
°

In testing for 2000 to 2020.

Intake camshaft position commanded K5_INTAKE_CAMSHAFT_POSITION_COMMANDED

  • Request21 17
  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 2)
Range
-64 to 63.5 °
Unit
°

In testing for 2000 to 2020.

Intake manifold absolute pressure K5_INTAKE_MANIFOLD_ABSOLUTE_PRESSURE

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 256)
Range
0 to 255 kPa
Unit
kPa

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Knock retard cylinder #1 K5_KNOCK_RETARD_CYLINDER_1

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Knock retard cylinder #2 K5_KNOCK_RETARD_CYLINDER_2

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Knock retard cylinder #3 K5_KNOCK_RETARD_CYLINDER_3

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Knock retard cylinder #4 K5_KNOCK_RETARD_CYLINDER_4

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Oxygen sensor 1 bank 1 K5_OXYGEN_SENSOR_11

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.00521 − 0.2)
Range
-0.2 to 1.12 V
Unit
V

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Oxygen sensor 2 bank 1 K5_OXYGEN_SENSOR_21

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val × 0.00521 − 0.2)
Range
-0.2 to 1.12 V
Unit
V

In testing for 2000 to 2020. Not supported for 2021 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?