Jeep Commander

Door parameters

The Jeep Commander has 5 door parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Driver door open JEEP_DRIVER_DOOR_OPEN

  • Request22 03 02
  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2007, 2009 to 2010, 2018 to 2024, 2026. Not supported for 2008, 2025.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Driver door open JEEP_DRIVER_DOOR_OPEN

  • Request22 03 02
  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2007, 2009 to 2010, 2018 to 2024, 2026. Not supported for 2008, 2025.

Passenger door open JEEP_PASSENGER_DOOR_OPEN

  • Request22 03 02
  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2007, 2009 to 2010, 2018 to 2024, 2026. Not supported for 2008, 2025.

Rear left door open JEEP_RLD_OPEN

  • Request22 03 02
  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2007, 2009 to 2010, 2018 to 2024, 2026. Not supported for 2008, 2025.

Rear right door open JEEP_RRD_OPEN

  • Request22 03 02
  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2007, 2009 to 2010, 2018 to 2024, 2026. Not supported for 2008, 2025.

Trunk open JEEP_TRUNK_OPEN

  • Request22 03 02
  • Service 22DID 0302
  • ModuleDAC7 → C7
  • Every1 s
  • Testing

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2006 to 2007, 2009 to 2010, 2018 to 2024, 2026. Not supported for 2008, 2025.