Jeep Commander

Control parameters

The Jeep Commander has 16 control parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Absolute throttle position TPConfirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Request01 11
  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2006, 2008.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Absolute throttle position TPSAE J1979Confirmed

Throttle position at idle will usually be more than 0%, and throttle position at wide open throttle will usually be less than 100%.

Pelican can show this parameter as the throttle position.

  • Request01 11
  • Service 01PID 11
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2025. Supported for 2006, 2008.

Absolute throttle position B TP_BSAE J1979Confirmed

Pelican can show this parameter as the throttle position.

  • Request01 47
  • Service 01PID 47
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Anti-lock brake or stability control regulating JEEP_ABS_EKS_PROCESS_ADJ

  • Request22 D4 74
  • Service 22DID D474
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2010, 2018 to 2026.

Brake booster pressure JEEP_BRAKE_BOOSTER_P

  • Request22 09 44
  • Service 22DID 0944
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 kPa
Unit
kPa

In testing for 2006 to 2010, 2018 to 2026.

Brake circuit pressure JEEP_BRAKE_CIRCUIT_P

  • Request22 D7 0E
  • Service 22DID D70E
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 55)
Range
-55 to 6498 bar
Unit
bar

In testing for 2006 to 2010, 2018 to 2026.

Brake system backup contactor status JEEP_BRAKE_SYSTEM_BACKUP

  • Request22 D4 63
  • Service 22DID D463
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2010, 2018 to 2026.

High beam mode JEEP_HIGHBEAMS_MODE

  • Request22 03 2D
  • Service 22DID 032D
  • Module763 → 4E3
  • Every2 s
  • Testing

Bits 4 to 7 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1ONOn
2HELDHeld

In testing for 2006 to 2007, 2009 to 2010, 2018 to 2024, 2026. Not supported for 2008, 2025.

High beams JEEP_HIGHBEAMS_ON

  • Request22 03 2D
  • Service 22DID 032D
  • Module763 → 4E3
  • Every2 s
  • Testing

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2006 to 2007, 2009 to 2010, 2018 to 2024, 2026. Not supported for 2008, 2025.

Main brake contactor status JEEP_MAIN_BRAKE_CONTACTOR

  • Request22 D5 13
  • Service 22DID D513
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2010, 2018 to 2026.

Rear wiper JEEP_REAR_WIPER

  • Request22 03 2D
  • Service 22DID 032D
  • Module763 → 4E3
  • Every2 s
  • Testing

Bits 12 to 15 of the reply, 4 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1SPRAYSpray
2AUTOAuto
4ONOn

In testing for 2006 to 2007, 2009 to 2010, 2018 to 2024, 2026. Not supported for 2008, 2025.

Relative throttle position TP_RSAE J1979Confirmed

Relative or 'learned' throttle position.

  • Request01 45
  • Service 01PID 45
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Secondary brake contactor status JEEP_SECONDARY_BRAKE

  • Request22 D5 14
  • Service 22DID D514
  • Module6A9 → 689
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2010, 2018 to 2026.

Steering wheel angle JEEP_STEER_ANGLE

  • Request22 08 85
  • Service 22DID 0885
  • ModuleDA30 → 30
  • Every100 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 720)
Range
-720 to 720 °
Unit
°

In testing for 2006 to 2007, 2009 to 2010, 2018 to 2024, 2026. Not supported for 2008, 2025.

Vacuum present in the brake system JEEP_VACUUM_PRESENT_BRAKE

  • Request22 D7 00
  • Service 22DID D700
  • Module6A8 → 688
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2006 to 2010, 2018 to 2026.

Control › Pedals

Accelerator pedal position D APP_DSAE J1979Confirmed

  • Request01 49
  • Service 01PID 49
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Accelerator pedal position E APP_ESAE J1979Confirmed

  • Request01 4A
  • Service 01PID 4A
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2025.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.