INFINITI Q45

Climate parameters

The INFINITI Q45 has 15 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C state INFINITI_AC_ON

  • Request22 11 06
  • Service 22DID 1106
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1990 to 2006.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C state INFINITI_AC_ON

  • Request22 11 06
  • Service 22DID 1106
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1990 to 2006.

Air conditioning compressor speed INFINITI_AC_COMP_RPM

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 168 to 183 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1990 to 2006.

Air conditioning on INFINITI_HVAC_AC_ON

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bit 80 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1990 to 2006.

Air conditioning status INFINITI_AC_STATUS

  • Request22 40 07
  • Service 22DID 4007
  • Module744
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Off or on

In testing for 1990 to 2006.

Ambient air temperature INFINITI_AAT

  • Request22 40 08
  • Service 22DID 4008
  • Module744
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1990 to 2006.

Ambient air temperature INFINITI_AAT_V2

  • Request22 11 5D
  • Service 22DID 115D
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 0.9 − 40.9)
Range
-36.81 to 192.69 °F
Unit
°F

In testing for 1990 to 2006.

Ambient air temperature, climate module INFINITI_HVAC_AAT

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1990 to 2006.

Blower on INFINITI_HVAC_FAN_ON

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bit 88 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1990 to 2006.

Blower voltage INFINITI_HVAC_BLOWER_V

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 89 to 95 of the reply, 7 bits.

Formula
val
Range
0 to 127 V
Unit
V

In testing for 1990 to 2006.

Cabin temperature INFINITI_HVAC_CABIN_T

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1990 to 2006.

ECO mode state INFINITI_ECO_MODE

  • Request22 13 18
  • Service 22DID 1318
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0ECO_OFFECO is off
16ECO_ON_1ECO is on
17ECO_ON_2ECO is on

In testing for 1990 to 2006.

Engine coolant temperature INFINITI_ECT

Pelican can show this parameter as the engine coolant temperature.

  • Request22 F4 67
  • Service 22DID F467
  • Module744
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1990 to 2006.

Evaporator temperature INFINITI_HVAC_EVAP_T

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1990 to 2006.

Rear heater state INFINITI_HTR_REAR

  • Request22 11 0F
  • Service 22DID 110F
  • Module797 → 79A
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
162HEATER_ONHeater is on

In testing for 1990 to 2006.

Sun load INFINITI_HVAC_SUNLOAD

  • Request21 10
  • Service 21PID 10
  • Module744 → 764
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1990 to 2006.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.