Battery parameters
The INFINITI Q45 has 513 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery current INFINITI_12V_CURR
- Request
22 11 83 - Service 22
DID 1183 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 256)- Range
- -128 to 128 A
- Unit
- A
In testing for 1990 to 2006.
12V battery voltage INFINITI_VPWR
Pelican can show this parameter as the starter battery voltage.
- Request
22 11 03 - Service 22
DID 1103 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 12.5)- Range
- 0 to 30 V
- Unit
- V
In testing for 1990 to 2006.
Absolute time since first ignition INFINITI_ABS_TIME_SINCE_FIRST
- Request
22 92 61 - Service 22
DID 9261 - Module
DADB → DAF1DB - Every
30 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 min
- Unit
- min
In testing for 1990 to 2006.
Accelerator pedal position sensor 1, volts INFINITI_ACCEL_PEDAL_POS_SENS_1
- Request
22 12 0D - Service 22
DID 120D - Module
DA18 → 18 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327 V
- Unit
- V
In testing for 1990 to 2006.
Accelerator pedal position sensor 2, volts INFINITI_ACCEL_PEDAL_POS_SENS_2
- Request
22 12 0E - Service 22
DID 120E - Module
DA18 → 18 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327 V
- Unit
- V
In testing for 1990 to 2006.
ALTERNATOR set point VOLTAGE INFINITI_ALTERNATOR_SETPOINT_V
- Request
21 69 - Service 21
PID 69 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310 V
- Unit
- V
In testing for 1990 to 2006.
Bus bar 1 flag INFINITI_BUSBAR_NO_1
- Request
22 91 CC - Service 22
DID 91CC - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Bus bar 1 voltage INFINITI_BUSBAR_V_NO_1
- Request
22 92 21 - Service 22
DID 9221 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.000976563)- Range
- -32 to 31.99 V
- Unit
- V
In testing for 1990 to 2006.
Bus bar 2 flag INFINITI_BUSBAR_NO_2
- Request
22 91 CC - Service 22
DID 91CC - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Bus bar 2 voltage INFINITI_BUSBAR_V_NO_2
- Request
22 92 22 - Service 22
DID 9222 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.000976563)- Range
- -32 to 31.99 V
- Unit
- V
In testing for 1990 to 2006.
Bus bar 3 flag INFINITI_BUSBAR_NO_3
- Request
22 91 CC - Service 22
DID 91CC - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 29 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Bus bar 3 voltage INFINITI_BUSBAR_V_NO_3
- Request
22 92 23 - Service 22
DID 9223 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.000976563)- Range
- -32 to 31.99 V
- Unit
- V
In testing for 1990 to 2006.
Bus bar 4 flag INFINITI_BUSBAR_NO_4
- Request
22 91 CC - Service 22
DID 91CC - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 28 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Bus bar 4 voltage INFINITI_BUSBAR_V_NO_4
- Request
22 92 24 - Service 22
DID 9224 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.000976563)- Range
- -32 to 31.99 V
- Unit
- V
In testing for 1990 to 2006.
Bus bar 5 flag INFINITI_BUSBAR_NO_5
- Request
22 91 CC - Service 22
DID 91CC - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 27 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Bus bar 5 voltage INFINITI_BUSBAR_V_NO_5
- Request
22 92 25 - Service 22
DID 9225 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.000976563)- Range
- -32 to 31.99 V
- Unit
- V
In testing for 1990 to 2006.
Bus bar 6 flag INFINITI_BUSBAR_NO_6
- Request
22 91 CC - Service 22
DID 91CC - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 26 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Bus bar 6 voltage INFINITI_BUSBAR_V_NO_6
- Request
22 92 26 - Service 22
DID 9226 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.000976563)- Range
- -32 to 31.99 V
- Unit
- V
In testing for 1990 to 2006.
Bus bar 7 flag INFINITI_BUSBAR_NO_7
- Request
22 91 CC - Service 22
DID 91CC - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Bus bar 7 voltage INFINITI_BUSBAR_V_NO_7
- Request
22 92 27 - Service 22
DID 9227 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.000976563)- Range
- -32 to 31.99 V
- Unit
- V
In testing for 1990 to 2006.
Bus bar 8 flag INFINITI_BUSBAR_NO_8
- Request
22 91 CC - Service 22
DID 91CC - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Bus bar 8 voltage INFINITI_BUSBAR_V_NO_8
- Request
22 92 28 - Service 22
DID 9228 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.000976563)- Range
- -32 to 31.99 V
- Unit
- V
In testing for 1990 to 2006.
Bus bar 9 flag INFINITI_BUSBAR_NO_9
- Request
22 91 CC - Service 22
DID 91CC - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Bus bar 10 flag INFINITI_BUSBAR_NO_10
- Request
22 91 CC - Service 22
DID 91CC - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Bus bar 11 flag INFINITI_BUSBAR_NO_11
- Request
22 91 CC - Service 22
DID 91CC - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Bus bar 12 flag INFINITI_BUSBAR_NO_12
- Request
22 91 CC - Service 22
DID 91CC - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 1 flag INFINITI_CELL_NUMBER_1
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 255 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 1 state of health flag INFINITI_SOH_CELL_1
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 255 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 1 voltage INFINITI_HVBAT_CELL_1_V
- Request
22 90 21 - Service 22
DID 9021 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 2 flag INFINITI_CELL_NUMBER_2
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 254 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 2 state of health flag INFINITI_SOH_CELL_2
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 254 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 2 voltage INFINITI_HVBAT_CELL_2_V
- Request
22 90 22 - Service 22
DID 9022 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 3 flag INFINITI_CELL_NUMBER_3
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 253 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 3 state of health flag INFINITI_SOH_CELL_3
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 253 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 3 voltage INFINITI_HVBAT_CELL_3_V
- Request
22 90 23 - Service 22
DID 9023 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 4 flag INFINITI_CELL_NUMBER_4
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 252 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 4 state of health flag INFINITI_SOH_CELL_4
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 252 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 4 voltage INFINITI_HVBAT_CELL_4_V
- Request
22 90 24 - Service 22
DID 9024 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 5 flag INFINITI_CELL_NUMBER_5
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 251 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 5 state of health flag INFINITI_SOH_CELL_5
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 251 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 5 voltage INFINITI_HVBAT_CELL_5_V
- Request
22 90 25 - Service 22
DID 9025 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 6 flag INFINITI_CELL_NUMBER_6
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 250 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 6 state of health flag INFINITI_SOH_CELL_6
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 250 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 6 voltage INFINITI_HVBAT_CELL_6_V
- Request
22 90 26 - Service 22
DID 9026 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 7 flag INFINITI_CELL_NUMBER_7
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 249 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 7 state of health flag INFINITI_SOH_CELL_7
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 249 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 7 voltage INFINITI_HVBAT_CELL_7_V
- Request
22 90 27 - Service 22
DID 9027 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 8 flag INFINITI_CELL_NUMBER_8
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 248 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 8 state of health flag INFINITI_SOH_CELL_8
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 248 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 8 voltage INFINITI_HVBAT_CELL_8_V
- Request
22 90 28 - Service 22
DID 9028 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 9 flag INFINITI_CELL_NUMBER_9
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 247 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 9 state of health flag INFINITI_SOH_CELL_9
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 247 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 9 voltage INFINITI_HVBAT_CELL_9_V
- Request
22 90 29 - Service 22
DID 9029 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 10 flag INFINITI_CELL_NUMBER_10
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 246 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 10 state of health flag INFINITI_SOH_CELL_10
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 246 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 10 voltage INFINITI_HVBAT_CELL_10_V
- Request
22 90 2A - Service 22
DID 902A - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 11 flag INFINITI_CELL_NUMBER_11
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 245 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 11 state of health flag INFINITI_SOH_CELL_11
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 245 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 11 voltage INFINITI_HVBAT_CELL_11_V
- Request
22 90 2B - Service 22
DID 902B - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 12 flag INFINITI_CELL_NUMBER_12
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 244 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 12 state of health flag INFINITI_SOH_CELL_12
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 244 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 12 voltage INFINITI_HVBAT_CELL_12_V
- Request
22 90 2C - Service 22
DID 902C - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 13 flag INFINITI_CELL_NUMBER_13
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 243 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 13 state of health flag INFINITI_SOH_CELL_13
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 243 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 13 voltage INFINITI_HVBAT_CELL_13_V
- Request
22 90 2D - Service 22
DID 902D - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 14 flag INFINITI_CELL_NUMBER_14
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 242 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 14 state of health flag INFINITI_SOH_CELL_14
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 242 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 14 voltage INFINITI_HVBAT_CELL_14_V
- Request
22 90 2E - Service 22
DID 902E - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 15 flag INFINITI_CELL_NUMBER_15
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 241 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 15 state of health flag INFINITI_SOH_CELL_15
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 241 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 15 voltage INFINITI_HVBAT_CELL_15_V
- Request
22 90 2F - Service 22
DID 902F - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 16 flag INFINITI_CELL_NUMBER_16
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 240 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 16 state of health flag INFINITI_SOH_CELL_16
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 240 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 16 voltage INFINITI_HVBAT_CELL_16_V
- Request
22 90 30 - Service 22
DID 9030 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 17 flag INFINITI_CELL_NUMBER_17
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 239 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 17 state of health flag INFINITI_SOH_CELL_17
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 239 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 17 voltage INFINITI_HVBAT_CELL_17_V
- Request
22 90 31 - Service 22
DID 9031 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 18 flag INFINITI_CELL_NUMBER_18
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 238 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 18 state of health flag INFINITI_SOH_CELL_18
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 238 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 18 voltage INFINITI_HVBAT_CELL_18_V
- Request
22 90 32 - Service 22
DID 9032 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 19 flag INFINITI_CELL_NUMBER_19
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 237 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 19 state of health flag INFINITI_SOH_CELL_19
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 237 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 19 voltage INFINITI_HVBAT_CELL_19_V
- Request
22 90 33 - Service 22
DID 9033 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 20 flag INFINITI_CELL_NUMBER_20
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 236 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 20 state of health flag INFINITI_SOH_CELL_20
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 236 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 20 voltage INFINITI_HVBAT_CELL_20_V
- Request
22 90 34 - Service 22
DID 9034 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 21 flag INFINITI_CELL_NUMBER_21
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 235 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 21 state of health flag INFINITI_SOH_CELL_21
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 235 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 21 voltage INFINITI_HVBAT_CELL_21_V
- Request
22 90 35 - Service 22
DID 9035 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 22 flag INFINITI_CELL_NUMBER_22
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 234 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 22 state of health flag INFINITI_SOH_CELL_22
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 234 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 22 voltage INFINITI_HVBAT_CELL_22_V
- Request
22 90 36 - Service 22
DID 9036 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 23 flag INFINITI_CELL_NUMBER_23
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 233 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 23 state of health flag INFINITI_SOH_CELL_23
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 233 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 23 voltage INFINITI_HVBAT_CELL_23_V
- Request
22 90 37 - Service 22
DID 9037 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 24 flag INFINITI_CELL_NUMBER_24
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 232 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 24 state of health flag INFINITI_SOH_CELL_24
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 232 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 24 voltage INFINITI_HVBAT_CELL_24_V
- Request
22 90 38 - Service 22
DID 9038 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 25 flag INFINITI_CELL_NUMBER_25
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 231 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 25 state of health flag INFINITI_SOH_CELL_25
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 231 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 25 voltage INFINITI_HVBAT_CELL_25_V
- Request
22 90 39 - Service 22
DID 9039 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 26 flag INFINITI_CELL_NUMBER_26
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 230 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 26 state of health flag INFINITI_SOH_CELL_26
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 230 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 26 voltage INFINITI_HVBAT_CELL_26_V
- Request
22 90 3A - Service 22
DID 903A - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 27 flag INFINITI_CELL_NUMBER_27
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 229 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 27 state of health flag INFINITI_SOH_CELL_27
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 229 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 27 voltage INFINITI_HVBAT_CELL_27_V
- Request
22 90 3B - Service 22
DID 903B - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 28 flag INFINITI_CELL_NUMBER_28
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 228 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 28 state of health flag INFINITI_SOH_CELL_28
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 228 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 28 voltage INFINITI_HVBAT_CELL_28_V
- Request
22 90 3C - Service 22
DID 903C - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 29 flag INFINITI_CELL_NUMBER_29
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 227 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 29 state of health flag INFINITI_SOH_CELL_29
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 227 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 29 voltage INFINITI_HVBAT_CELL_29_V
- Request
22 90 3D - Service 22
DID 903D - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 30 flag INFINITI_CELL_NUMBER_30
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 226 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 30 state of health flag INFINITI_SOH_CELL_30
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 226 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 30 voltage INFINITI_HVBAT_CELL_30_V
- Request
22 90 3E - Service 22
DID 903E - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 31 flag INFINITI_CELL_NUMBER_31
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 225 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 31 state of health flag INFINITI_SOH_CELL_31
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 225 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 31 voltage INFINITI_HVBAT_CELL_31_V
- Request
22 90 3F - Service 22
DID 903F - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 32 flag INFINITI_CELL_NUMBER_32
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 224 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 32 state of health flag INFINITI_SOH_CELL_32
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 224 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 32 voltage INFINITI_HVBAT_CELL_32_V
- Request
22 90 41 - Service 22
DID 9041 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 33 flag INFINITI_CELL_NUMBER_33
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 223 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 33 state of health flag INFINITI_SOH_CELL_33
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 223 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 33 voltage INFINITI_HVBAT_CELL_33_V
- Request
22 90 42 - Service 22
DID 9042 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 34 flag INFINITI_CELL_NUMBER_34
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 222 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 34 state of health flag INFINITI_SOH_CELL_34
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 222 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 34 voltage INFINITI_HVBAT_CELL_34_V
- Request
22 90 43 - Service 22
DID 9043 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 35 flag INFINITI_CELL_NUMBER_35
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 221 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 35 state of health flag INFINITI_SOH_CELL_35
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 221 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 35 voltage INFINITI_HVBAT_CELL_35_V
- Request
22 90 44 - Service 22
DID 9044 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 36 flag INFINITI_CELL_NUMBER_36
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 220 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 36 state of health flag INFINITI_SOH_CELL_36
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 220 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 36 voltage INFINITI_HVBAT_CELL_36_V
- Request
22 90 45 - Service 22
DID 9045 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 37 flag INFINITI_CELL_NUMBER_37
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 219 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 37 state of health flag INFINITI_SOH_CELL_37
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 219 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 37 voltage INFINITI_HVBAT_CELL_37_V
- Request
22 90 46 - Service 22
DID 9046 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 38 flag INFINITI_CELL_NUMBER_38
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 218 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 38 state of health flag INFINITI_SOH_CELL_38
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 218 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 38 voltage INFINITI_HVBAT_CELL_38_V
- Request
22 90 47 - Service 22
DID 9047 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 39 flag INFINITI_CELL_NUMBER_39
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 217 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 39 state of health flag INFINITI_SOH_CELL_39
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 217 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 39 voltage INFINITI_HVBAT_CELL_39_V
- Request
22 90 48 - Service 22
DID 9048 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 40 flag INFINITI_CELL_NUMBER_40
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 216 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 40 state of health flag INFINITI_SOH_CELL_40
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 216 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 40 voltage INFINITI_HVBAT_CELL_40_V
- Request
22 90 49 - Service 22
DID 9049 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 41 flag INFINITI_CELL_NUMBER_41
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 215 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 41 state of health flag INFINITI_SOH_CELL_41
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 215 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 41 voltage INFINITI_HVBAT_CELL_41_V
- Request
22 90 4A - Service 22
DID 904A - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 42 flag INFINITI_CELL_NUMBER_42
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 214 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 42 state of health flag INFINITI_SOH_CELL_42
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 214 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 42 voltage INFINITI_HVBAT_CELL_42_V
- Request
22 90 4B - Service 22
DID 904B - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 43 flag INFINITI_CELL_NUMBER_43
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 213 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 43 state of health flag INFINITI_SOH_CELL_43
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 213 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 43 voltage INFINITI_HVBAT_CELL_43_V
- Request
22 90 4C - Service 22
DID 904C - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 44 flag INFINITI_CELL_NUMBER_44
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 212 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 44 state of health flag INFINITI_SOH_CELL_44
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 212 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 44 voltage INFINITI_HVBAT_CELL_44_V
- Request
22 90 4D - Service 22
DID 904D - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 45 flag INFINITI_CELL_NUMBER_45
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 211 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 45 state of health flag INFINITI_SOH_CELL_45
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 211 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 45 voltage INFINITI_HVBAT_CELL_45_V
- Request
22 90 4E - Service 22
DID 904E - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 46 flag INFINITI_CELL_NUMBER_46
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 210 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 46 state of health flag INFINITI_SOH_CELL_46
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 210 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 46 voltage INFINITI_HVBAT_CELL_46_V
- Request
22 90 4F - Service 22
DID 904F - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 47 flag INFINITI_CELL_NUMBER_47
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 209 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 47 state of health flag INFINITI_SOH_CELL_47
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 209 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 47 voltage INFINITI_HVBAT_CELL_47_V
- Request
22 90 50 - Service 22
DID 9050 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 48 flag INFINITI_CELL_NUMBER_48
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 208 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 48 state of health flag INFINITI_SOH_CELL_48
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 208 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 48 voltage INFINITI_HVBAT_CELL_48_V
- Request
22 90 51 - Service 22
DID 9051 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 49 flag INFINITI_CELL_NUMBER_49
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 207 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 49 state of health flag INFINITI_SOH_CELL_49
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 207 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 49 voltage INFINITI_HVBAT_CELL_49_V
- Request
22 90 52 - Service 22
DID 9052 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 50 flag INFINITI_CELL_NUMBER_50
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 206 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 50 state of health flag INFINITI_SOH_CELL_50
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 206 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 50 voltage INFINITI_HVBAT_CELL_50_V
- Request
22 90 53 - Service 22
DID 9053 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 51 flag INFINITI_CELL_NUMBER_51
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 205 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 51 state of health flag INFINITI_SOH_CELL_51
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 205 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 51 voltage INFINITI_HVBAT_CELL_51_V
- Request
22 90 54 - Service 22
DID 9054 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 52 flag INFINITI_CELL_NUMBER_52
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 204 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 52 state of health flag INFINITI_SOH_CELL_52
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 204 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 52 voltage INFINITI_HVBAT_CELL_52_V
- Request
22 90 55 - Service 22
DID 9055 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 53 flag INFINITI_CELL_NUMBER_53
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 203 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 53 state of health flag INFINITI_SOH_CELL_53
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 203 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 53 voltage INFINITI_HVBAT_CELL_53_V
- Request
22 90 56 - Service 22
DID 9056 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 54 flag INFINITI_CELL_NUMBER_54
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 202 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 54 state of health flag INFINITI_SOH_CELL_54
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 202 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 54 voltage INFINITI_HVBAT_CELL_54_V
- Request
22 90 57 - Service 22
DID 9057 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 55 flag INFINITI_CELL_NUMBER_55
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 201 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 55 state of health flag INFINITI_SOH_CELL_55
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 201 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 55 voltage INFINITI_HVBAT_CELL_55_V
- Request
22 90 58 - Service 22
DID 9058 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 56 flag INFINITI_CELL_NUMBER_56
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 200 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 56 state of health flag INFINITI_SOH_CELL_56
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 200 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 56 voltage INFINITI_HVBAT_CELL_56_V
- Request
22 90 59 - Service 22
DID 9059 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 57 flag INFINITI_CELL_NUMBER_57
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 199 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 57 state of health flag INFINITI_SOH_CELL_57
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 199 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 57 voltage INFINITI_HVBAT_CELL_57_V
- Request
22 90 5A - Service 22
DID 905A - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 58 flag INFINITI_CELL_NUMBER_58
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 198 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 58 state of health flag INFINITI_SOH_CELL_58
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 198 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 58 voltage INFINITI_HVBAT_CELL_58_V
- Request
22 90 5B - Service 22
DID 905B - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 59 flag INFINITI_CELL_NUMBER_59
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 197 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 59 state of health flag INFINITI_SOH_CELL_59
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 197 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 59 voltage INFINITI_HVBAT_CELL_59_V
- Request
22 90 5C - Service 22
DID 905C - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 60 flag INFINITI_CELL_NUMBER_60
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 196 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 60 state of health flag INFINITI_SOH_CELL_60
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 196 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 60 voltage INFINITI_HVBAT_CELL_60_V
- Request
22 90 5D - Service 22
DID 905D - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 61 flag INFINITI_CELL_NUMBER_61
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 195 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 61 state of health flag INFINITI_SOH_CELL_61
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 195 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 61 voltage INFINITI_HVBAT_CELL_61_V
- Request
22 90 5E - Service 22
DID 905E - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 62 flag INFINITI_CELL_NUMBER_62
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 194 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 62 state of health flag INFINITI_SOH_CELL_62
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 194 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 62 voltage INFINITI_HVBAT_CELL_62_V
- Request
22 90 5F - Service 22
DID 905F - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 63 flag INFINITI_CELL_NUMBER_63
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 193 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 63 state of health flag INFINITI_SOH_CELL_63
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 193 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 63 voltage INFINITI_HVBAT_CELL_63_V
- Request
22 90 61 - Service 22
DID 9061 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 64 flag INFINITI_CELL_NUMBER_64
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 192 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 64 state of health flag INFINITI_SOH_CELL_64
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 192 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 64 voltage INFINITI_HVBAT_CELL_64_V
- Request
22 90 62 - Service 22
DID 9062 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 65 flag INFINITI_CELL_NUMBER_65
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 191 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 65 state of health flag INFINITI_SOH_CELL_65
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 191 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 65 voltage INFINITI_HVBAT_CELL_65_V
- Request
22 90 63 - Service 22
DID 9063 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 66 flag INFINITI_CELL_NUMBER_66
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 190 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 66 state of health flag INFINITI_SOH_CELL_66
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 190 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 66 voltage INFINITI_HVBAT_CELL_66_V
- Request
22 90 64 - Service 22
DID 9064 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 67 flag INFINITI_CELL_NUMBER_67
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 189 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 67 state of health flag INFINITI_SOH_CELL_67
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 189 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 67 voltage INFINITI_HVBAT_CELL_67_V
- Request
22 90 65 - Service 22
DID 9065 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 68 flag INFINITI_CELL_NUMBER_68
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 188 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 68 state of health flag INFINITI_SOH_CELL_68
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 188 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 68 voltage INFINITI_HVBAT_CELL_68_V
- Request
22 90 66 - Service 22
DID 9066 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 69 flag INFINITI_CELL_NUMBER_69
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 187 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 69 state of health flag INFINITI_SOH_CELL_69
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 187 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 69 voltage INFINITI_HVBAT_CELL_69_V
- Request
22 90 67 - Service 22
DID 9067 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 70 flag INFINITI_CELL_NUMBER_70
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 186 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 70 state of health flag INFINITI_SOH_CELL_70
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 186 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 70 voltage INFINITI_HVBAT_CELL_70_V
- Request
22 90 68 - Service 22
DID 9068 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 71 flag INFINITI_CELL_NUMBER_71
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 185 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 71 state of health flag INFINITI_SOH_CELL_71
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 185 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 71 voltage INFINITI_HVBAT_CELL_71_V
- Request
22 90 69 - Service 22
DID 9069 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 72 flag INFINITI_CELL_NUMBER_72
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 184 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 72 state of health flag INFINITI_SOH_CELL_72
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 184 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 72 voltage INFINITI_HVBAT_CELL_72_V
- Request
22 90 6A - Service 22
DID 906A - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 73 flag INFINITI_CELL_NUMBER_73
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 183 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 73 state of health flag INFINITI_SOH_CELL_73
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 183 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 73 voltage INFINITI_HVBAT_CELL_73_V
- Request
22 90 6B - Service 22
DID 906B - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 74 flag INFINITI_CELL_NUMBER_74
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 182 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 74 state of health flag INFINITI_SOH_CELL_74
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 182 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 74 voltage INFINITI_HVBAT_CELL_74_V
- Request
22 90 6C - Service 22
DID 906C - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 75 flag INFINITI_CELL_NUMBER_75
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 181 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 75 state of health flag INFINITI_SOH_CELL_75
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 181 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 75 voltage INFINITI_HVBAT_CELL_75_V
- Request
22 90 6D - Service 22
DID 906D - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 76 flag INFINITI_CELL_NUMBER_76
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 180 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 76 state of health flag INFINITI_SOH_CELL_76
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 180 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 76 voltage INFINITI_HVBAT_CELL_76_V
- Request
22 90 6E - Service 22
DID 906E - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 77 flag INFINITI_CELL_NUMBER_77
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 179 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 77 state of health flag INFINITI_SOH_CELL_77
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 179 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 77 voltage INFINITI_HVBAT_CELL_77_V
- Request
22 90 6F - Service 22
DID 906F - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 78 flag INFINITI_CELL_NUMBER_78
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 177 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 78 state of health flag INFINITI_SOH_CELL_78
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 178 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 78 voltage INFINITI_HVBAT_CELL_78_V
- Request
22 90 70 - Service 22
DID 9070 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 79 state of health flag INFINITI_SOH_CELL_79
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 177 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 79 voltage INFINITI_HVBAT_CELL_79_V
- Request
22 90 71 - Service 22
DID 9071 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 80 flag INFINITI_CELL_NUMBER_80
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 176 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 80 state of health flag INFINITI_SOH_CELL_80
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 176 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 80 voltage INFINITI_HVBAT_CELL_80_V
- Request
22 90 72 - Service 22
DID 9072 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 81 flag INFINITI_CELL_NUMBER_81
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 175 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 81 state of health flag INFINITI_SOH_CELL_81
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 175 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 81 voltage INFINITI_HVBAT_CELL_81_V
- Request
22 90 73 - Service 22
DID 9073 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 82 flag INFINITI_CELL_NUMBER_82
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 174 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 82 state of health flag INFINITI_SOH_CELL_82
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 174 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 82 voltage INFINITI_HVBAT_CELL_82_V
- Request
22 90 74 - Service 22
DID 9074 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 83 flag INFINITI_CELL_NUMBER_83
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 173 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 83 state of health flag INFINITI_SOH_CELL_83
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 173 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 83 voltage INFINITI_HVBAT_CELL_83_V
- Request
22 90 75 - Service 22
DID 9075 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 84 flag INFINITI_CELL_NUMBER_84
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 172 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 84 state of health flag INFINITI_SOH_CELL_84
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 172 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 84 voltage INFINITI_HVBAT_CELL_84_V
- Request
22 90 76 - Service 22
DID 9076 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 85 flag INFINITI_CELL_NUMBER_85
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 171 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 85 state of health flag INFINITI_SOH_CELL_85
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 171 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 85 voltage INFINITI_HVBAT_CELL_85_V
- Request
22 90 77 - Service 22
DID 9077 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 86 flag INFINITI_CELL_NUMBER_86
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 170 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 86 state of health flag INFINITI_SOH_CELL_86
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 170 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 86 voltage INFINITI_HVBAT_CELL_86_V
- Request
22 90 78 - Service 22
DID 9078 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 87 flag INFINITI_CELL_NUMBER_87
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 169 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 87 state of health flag INFINITI_SOH_CELL_87
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 169 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 87 voltage INFINITI_HVBAT_CELL_87_V
- Request
22 90 79 - Service 22
DID 9079 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 88 flag INFINITI_CELL_NUMBER_88
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 168 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 88 state of health flag INFINITI_SOH_CELL_88
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 168 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 88 voltage INFINITI_HVBAT_CELL_88_V
- Request
22 90 7A - Service 22
DID 907A - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 89 flag INFINITI_CELL_NUMBER_89
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 167 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 89 state of health flag INFINITI_SOH_CELL_89
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 167 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 89 voltage INFINITI_HVBAT_CELL_89_V
- Request
22 90 7B - Service 22
DID 907B - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 90 flag INFINITI_CELL_NUMBER_90
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 166 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 90 state of health flag INFINITI_SOH_CELL_90
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 166 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 90 voltage INFINITI_HVBAT_CELL_90_V
- Request
22 90 7C - Service 22
DID 907C - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 91 flag INFINITI_CELL_NUMBER_91
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 165 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 91 state of health flag INFINITI_SOH_CELL_91
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 165 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 91 voltage INFINITI_HVBAT_CELL_91_V
- Request
22 90 7D - Service 22
DID 907D - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 92 flag INFINITI_CELL_NUMBER_92
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 164 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 92 state of health flag INFINITI_SOH_CELL_92
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 164 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 92 voltage INFINITI_HVBAT_CELL_92_V
- Request
22 90 7E - Service 22
DID 907E - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 93 flag INFINITI_CELL_NUMBER_93
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 163 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 93 state of health flag INFINITI_SOH_CELL_93
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 163 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 93 voltage INFINITI_HVBAT_CELL_93_V
- Request
22 90 7F - Service 22
DID 907F - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 94 flag INFINITI_CELL_NUMBER_94
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 162 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 94 state of health flag INFINITI_SOH_CELL_94
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 162 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 94 voltage INFINITI_HVBAT_CELL_94_V
- Request
22 90 81 - Service 22
DID 9081 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 95 flag INFINITI_CELL_NUMBER_95
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 161 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 95 state of health flag INFINITI_SOH_CELL_95
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 161 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 95 voltage INFINITI_HVBAT_CELL_95_V
- Request
22 90 82 - Service 22
DID 9082 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell 96 flag INFINITI_CELL_NUMBER_96
- Request
22 92 56 - Service 22
DID 9256 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 160 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 96 state of health flag INFINITI_SOH_CELL_96
- Request
22 92 7A - Service 22
DID 927A - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 160 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cell 96 voltage INFINITI_HVBAT_CELL_96_V
- Request
22 90 83 - Service 22
DID 9083 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cell with the highest voltage INFINITI_CELL_HIGHEST_V
- Request
22 90 08 - Service 22
DID 9008 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val + 1)- Range
- 0 to 256
- Unit
- Number
In testing for 1990 to 2006.
Cell with the lowest voltage INFINITI_CELL_LOWEST_V
- Request
22 90 0A - Service 22
DID 900A - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val + 1)- Range
- 0 to 256
- Unit
- Number
In testing for 1990 to 2006.
Cells overvoltage INFINITI_CELLS_OVERVOLAGE
- Request
22 92 16 - Service 22
DID 9216 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Cells undervoltage INFINITI_CELLS_UNDERVOLTAGE
- Request
22 92 16 - Service 22
DID 9216 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Charging mode INFINITI_CHARGE_MODE
Pelican can show this parameter as the charging state.
- Request
22 11 4E - Service 22
DID 114E - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NOT_CHARGING | Not charging |
1 | CHARGING_L1 | L1 charging (100-120V) |
2 | CHARGING_L2 | L2 charging (200-240V) |
3 | CHARGING_L3 | L3 quick charging |
In testing for 1990 to 2006.
Charging power INFINITI_CHRG_PWR
Power entering the high voltage battery while charging.
- Request
22 12 36 - Service 22
DID 1236 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100)- Range
- 0 to 6553500 W
- Unit
- W
In testing for 1990 to 2006.
Computer power supply INFINITI_COMPUTER_POWER_SUP
- Request
22 90 11 - Service 22
DID 9011 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Cumulative energy when discharging INFINITI_CUM_ENERGY
- Request
22 92 45 - Service 22
DID 9245 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 1000)- Range
- -2147483 to 2147483 kWh
- Unit
- kWh
In testing for 1990 to 2006.
DC battery capacity INFINITI_DC_BAT_CAP
- Request
22 91 C8 - Service 22
DID 91C8 - Module
DADA → DAF1DA - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 16777 kWh
- Unit
- kWh
In testing for 1990 to 2006.
DC battery current INFINITI_DC_BAT_CURRENT
- Request
22 21 CC - Service 22
DID 21CC - Module
DADA → DAF1DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × -1 ÷ 4 + 500)- Range
- -15883 to 500 A
- Unit
- A
In testing for 1990 to 2006.
DC battery state of charge INFINITI_DC_BAT_ST_CHG
- Request
22 90 02 - Service 22
DID 9002 - Module
DADA → DAF1DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 1990 to 2006.
DC battery state of health INFINITI_DC_BAT_ST_HEALTH
- Request
22 90 03 - Service 22
DID 9003 - Module
DADA → DAF1DA - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 %
- Unit
- %
In testing for 1990 to 2006.
DC battery voltage INFINITI_DC_BAT_V
- Request
22 20 FE - Service 22
DID 20FE - Module
DADA → DAF1DA - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 1990 to 2006.
EVAP pressure sensor voltage INFINITI_EVAP_P_SENS_V
- Request
22 11 15 - Service 22
DID 1115 - Module
DA18 → 18 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 1990 to 2006.
Exhaust gas recirculation temperature sensor voltage INFINITI_EGR_T_SENS_V
- Request
22 11 05 - Service 22
DID 1105 - Module
DA18 → 18 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 1990 to 2006.
Fan unit INFINITI_FAN_UNIT
- Request
22 91 EF - Service 22
DID 91EF - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1990 to 2006.
Fan unit feed INFINITI_FAN_UNIT_FEED
- Request
22 92 5A - Service 22
DID 925A - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 Hz
- Unit
- Hz
In testing for 1990 to 2006.
Fault finding version INFINITI_FAULT_FINDING
- Request
22 F1 A0 - Service 22
DID F1A0 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2006.
Fuel pressure sensor voltage INFINITI_FUEL_P_SENS_V
- Request
22 12 0C - Service 22
DID 120C - Module
DA18 → 18 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 4 ÷ 13107)- Range
- 0 to 20 V
- Unit
- V
In testing for 1990 to 2006.
Fuel rail temperature sensor voltage INFINITI_FUEL_RAIL_T_SENS_V
- Request
21 AD - Service 21
PID AD - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
In testing for 1990 to 2006.
Fuel tank temperature sensor voltage INFINITI_FUEL_TANK_T_SENS_V
- Request
21 AD - Service 21
PID AD - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 5 ÷ 256)- Range
- 0 to 4.98 V
- Unit
- V
In testing for 1990 to 2006.
High voltage battery capacity INFINITI_HVBAT_CAP
- Request
21 01 - Service 21
PID 01 - Module
79B → 7BB - Every
1 s - Testing
Bits 280 to 303 of the reply, 24 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 1000 Ah
- Unit
- Ah
In testing for 1990 to 2006.
High voltage battery capacity INFINITI_HVBAT_CAP_PRE18
- Request
21 01 - Service 21
PID 01 - Module
79B → 7BB - Every
1 s - Testing
Bits 264 to 287 of the reply, 24 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 1000 Ah
- Unit
- Ah
In testing for 1990 to 2006.
High voltage battery charge INFINITI_HVBAT_SOC
Pelican can show this parameter as the state of charge.
- Request
21 01 - Service 21
PID 01 - Module
79B → 7BB - Every
1 s - Testing
Bits 248 to 271 of the reply, 24 bits.
- Formula
(val ÷ 8190 − 17)- Range
- 0 to 100 %
- Unit
- %
In testing for 1990 to 2006.
High voltage battery charge INFINITI_HVBAT_SOC_PRE18
Pelican can show this parameter as the state of charge.
- Request
21 01 - Service 21
PID 01 - Module
79B → 7BB - Every
1 s - Testing
Bits 232 to 255 of the reply, 24 bits.
- Formula
(val ÷ 10000)- Range
- 0 to 100 %
- Unit
- %
In testing for 1990 to 2006.
High voltage battery health INFINITI_HVBAT_SOH
When the battery is new, its health should be ~100%.
Pelican can show this parameter as the state of health.
- Request
21 61 - Service 21
PID 61 - Module
79B → 7BB - Every
3600 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 1990 to 2006.
High voltage battery voltage INFINITI_HVBAT_VOLT
Pelican can show this parameter as the traction battery voltage.
- Request
21 01 - Service 21
PID 01 - Module
79B → 7BB - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 1990 to 2006.
High voltage battery voltage INFINITI_HVBAT_VOLT_PRE18
Pelican can show this parameter as the traction battery voltage.
- Request
21 01 - Service 21
PID 01 - Module
79B → 7BB - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 1990 to 2006.
Highest cell voltage level INFINITI_HIGHEST_CELL_V_LEVEL
- Request
22 90 07 - Service 22
DID 9007 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
HV battery current INFINITI_HVBAT_I
Pelican can show this parameter as the traction battery current.
- Request
22 12 48 - Service 22
DID 1248 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -16384 to 16383.5 A
- Unit
- A
In testing for 1990 to 2006.
HV battery pack 1 temperature INFINITI_HVBAT_PACK_1_T
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 16 to 23 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 1990 to 2006.
HV battery pack 2 temperature INFINITI_HVBAT_PACK_2_T
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 40 to 47 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 1990 to 2006.
HV battery pack 4 temperature INFINITI_HVBAT_PACK_4_T
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 88 to 95 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 1990 to 2006.
HV battery pack 5 temperature INFINITI_HVBAT_PACK_5_T
- Request
21 04 - Service 21
PID 04 - Module
79B → 7BB - Every
30 s - Testing
Bits 96 to 103 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 1990 to 2006.
HV battery pack voltage INFINITI_HVBAT_PACK_V
Pelican can show this parameter as the traction battery voltage.
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,536 to 1,551 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
In testing for 1990 to 2006.
HV bus voltage INFINITI_HVBAT_BUS_V
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,552 to 1,567 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
In testing for 1990 to 2006.
L1/L2 charge port plug state INFINITI_CHARGE_PLUG
Pelican can show this parameter as the plug state.
- Request
22 12 34 - Service 22
DID 1234 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | UNPLUGGED | Not plugged in |
1 | PLUGGED_PARTIAL | Partially plugged in |
2 | PLUGGED | Plugged in |
In testing for 1990 to 2006.
Lowest cell voltage level INFINITI_LOWEST_CELL_V_LEVEL
- Request
22 90 09 - Service 22
DID 9009 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.000976563)- Range
- 0 to 63.99 V
- Unit
- V
In testing for 1990 to 2006.
Manifold pressure sensor voltage INFINITI_MANIFOLD_P_SENS_V
- Request
22 11 2A - Service 22
DID 112A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 1990 to 2006.
Maximum cell voltage INFINITI_MAX_CELL_V
- Request
21 03 - Service 21
PID 03 - Module
79B → 7BB - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4.5 V
- Unit
- V
In testing for 1990 to 2006.
Minimum cell voltage INFINITI_MIN_CELL_V
- Request
21 03 - Service 21
PID 03 - Module
79B → 7BB - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 4.5 V
- Unit
- V
In testing for 1990 to 2006.
Module 1 temperature INFINITI_MODULE_T_NUMBER_1
- Request
22 91 31 - Service 22
DID 9131 - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Module 1 temperature sensor flag INFINITI_T_SENS_MODULE_N_1
- Request
22 91 2F - Service 22
DID 912F - Module
DADB → DAF1DB - Every
5 s - Testing
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Module 2 temperature INFINITI_MODULE_T_NUMBER_2
- Request
22 91 32 - Service 22
DID 9132 - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Module 2 temperature sensor flag INFINITI_T_SENS_MODULE_N_2
- Request
22 91 2F - Service 22
DID 912F - Module
DADB → DAF1DB - Every
5 s - Testing
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Module 3 temperature INFINITI_MODULE_T_NUMBER_3
- Request
22 91 33 - Service 22
DID 9133 - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Module 3 temperature sensor flag INFINITI_T_SENS_MODULE_N_3
- Request
22 91 2F - Service 22
DID 912F - Module
DADB → DAF1DB - Every
5 s - Testing
Bit 29 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Module 4 temperature INFINITI_MODULE_T_NUMBER_4
- Request
22 91 34 - Service 22
DID 9134 - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Module 4 temperature sensor flag INFINITI_T_SENS_MODULE_N_4
- Request
22 91 2F - Service 22
DID 912F - Module
DADB → DAF1DB - Every
5 s - Testing
Bit 28 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Module 5 temperature INFINITI_MODULE_T_NUMBER_5
- Request
22 91 35 - Service 22
DID 9135 - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Module 5 temperature sensor flag INFINITI_T_SENS_MODULE_N_5
- Request
22 91 2F - Service 22
DID 912F - Module
DADB → DAF1DB - Every
5 s - Testing
Bit 27 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Module 6 temperature INFINITI_MODULE_T_NUMBER_6
- Request
22 91 36 - Service 22
DID 9136 - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Module 6 temperature sensor flag INFINITI_T_SENS_MODULE_N_6
- Request
22 91 2F - Service 22
DID 912F - Module
DADB → DAF1DB - Every
5 s - Testing
Bit 26 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Module 7 temperature INFINITI_MODULE_T_NUMBER_7
- Request
22 91 37 - Service 22
DID 9137 - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Module 7 temperature sensor flag INFINITI_T_SENS_MODULE_N_7
- Request
22 91 2F - Service 22
DID 912F - Module
DADB → DAF1DB - Every
5 s - Testing
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Module 8 temperature INFINITI_MODULE_T_NUMBER_8
- Request
22 91 38 - Service 22
DID 9138 - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Module 8 temperature sensor flag INFINITI_T_SENS_MODULE_N_8
- Request
22 91 2F - Service 22
DID 912F - Module
DADB → DAF1DB - Every
5 s - Testing
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Module 9 temperature INFINITI_MODULE_T_NUMBER_9
- Request
22 91 39 - Service 22
DID 9139 - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Module 9 temperature sensor flag INFINITI_T_SENS_MODULE_N_9
- Request
22 91 2F - Service 22
DID 912F - Module
DADB → DAF1DB - Every
5 s - Testing
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Module 10 temperature INFINITI_MODULE_T_NUMBER_10
- Request
22 91 3A - Service 22
DID 913A - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Module 10 temperature sensor flag INFINITI_T_SENS_MODULE_N_10
- Request
22 91 2F - Service 22
DID 912F - Module
DADB → DAF1DB - Every
5 s - Testing
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Module 11 temperature INFINITI_MODULE_T_NUMBER_11
- Request
22 91 3B - Service 22
DID 913B - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Module 11 temperature sensor flag INFINITI_T_SENS_MODULE_N_11
- Request
22 91 2F - Service 22
DID 912F - Module
DADB → DAF1DB - Every
5 s - Testing
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Module 12 temperature INFINITI_MODULE_T_NUMBER_12
- Request
22 91 3C - Service 22
DID 913C - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Module 12 temperature sensor flag INFINITI_T_SENS_MODULE_N_12
- Request
22 91 2F - Service 22
DID 912F - Module
DADB → DAF1DB - Every
5 s - Testing
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Module with the minimum temperature INFINITI_MODULE_MIN_T
- Request
22 92 42 - Service 22
DID 9242 - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2006.
Motor-driven fan unit request INFINITI_MOTOR_DRIVEN_FAN
- Request
22 91 C9 - Service 22
DID 91C9 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 1990 to 2006.
Open circuit voltage INFINITI_OPEN_CIRCUIT_V
- Request
22 90 05 - Service 22
DID 9005 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 V
- Unit
- V
In testing for 1990 to 2006.
Refrigerant fluid sensor voltage INFINITI_REFRIGERANT_FLUID_V
- Request
22 12 23 - Service 22
DID 1223 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327 V
- Unit
- V
In testing for 1990 to 2006.
Roll-over sensor voltage INFINITI_ROLL_OVER_SENS_V
- Request
22 12 1F - Service 22
DID 121F - Module
DA18 → 18 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327 V
- Unit
- V
In testing for 1990 to 2006.
Secondary battery management board 1 INFINITI_SECONDARY_BMS_NO_1
- Request
22 91 29 - Service 22
DID 9129 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 31 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Secondary battery management board 2 INFINITI_SECONDARY_BMS_NO_2
- Request
22 91 29 - Service 22
DID 9129 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 30 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Secondary battery management board 3 INFINITI_SECONDARY_BMS_NO_3
- Request
22 91 29 - Service 22
DID 9129 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 29 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Secondary battery management board 4 INFINITI_SECONDARY_BMS_NO_4
- Request
22 91 29 - Service 22
DID 9129 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 28 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Secondary battery management board 5 INFINITI_SECONDARY_BMS_NO_5
- Request
22 91 29 - Service 22
DID 9129 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 27 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Secondary battery management board 6 INFINITI_SECONDARY_BMS_NO_6
- Request
22 91 29 - Service 22
DID 9129 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 26 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Secondary battery management board 7 INFINITI_SECONDARY_BMS_NO_7
- Request
22 91 29 - Service 22
DID 9129 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 25 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Secondary battery management board 8 INFINITI_SECONDARY_BMS_NO_8
- Request
22 91 29 - Service 22
DID 9129 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 24 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Secondary battery management board 9 INFINITI_SECONDARY_BMS_NO_9
- Request
22 91 29 - Service 22
DID 9129 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 23 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Secondary battery management board 10 INFINITI_SECONDARY_BMS_NO_10
- Request
22 91 29 - Service 22
DID 9129 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 22 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Secondary battery management board 11 INFINITI_SECONDARY_BMS_NO_11
- Request
22 91 29 - Service 22
DID 9129 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 21 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Secondary battery management board 12 INFINITI_SECONDARY_BMS_NO_12
- Request
22 91 29 - Service 22
DID 9129 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 20 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
State of charge, as the dash shows it INFINITI_SOC_DASH
Pelican can show this parameter as the state of charge.
- Request
22 0E 2D - Service 22
DID 0E2D - Module
743 → 763 - Every
30 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 1990 to 2006.
Throttle position sensor 1, volts INFINITI_THROTTLE_POS_SENS_1
- Request
22 12 0F - Service 22
DID 120F - Module
DA18 → 18 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327 V
- Unit
- V
In testing for 1990 to 2006.
Throttle position sensor 2, volts INFINITI_THROTTLE_POS_SENS_2
- Request
22 12 10 - Service 22
DID 1210 - Module
DA18 → 18 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327 V
- Unit
- V
In testing for 1990 to 2006.
Traction battery compartment temperature INFINITI_TRACTION_BAT_T
- Request
22 90 12 - Service 22
DID 9012 - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Traction battery current INFINITI_TRACTION_BAT_CURRENT
Pelican can show this parameter as the traction battery current.
- Request
22 92 84 - Service 22
DID 9284 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val × -1 ÷ 1000)- Range
- -2147483 to 2147483 A
- Unit
- A
In testing for 1990 to 2006.
Traction battery input water temperature INFINITI_TRACTION_BAT_INPUT_T
- Request
22 91 CD - Service 22
DID 91CD - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Traction battery interlock INFINITI_TRACTION_BAT_INTERLOCK
- Request
22 91 F7 - Service 22
DID 91F7 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2006.
Traction battery maximum temperature INFINITI_TRACTION_BAT_MAX_T
- Request
22 90 14 - Service 22
DID 9014 - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Traction battery minimum temperature INFINITI_TRACTION_BAT_MIN_T
- Request
22 90 13 - Service 22
DID 9013 - Module
DADB → DAF1DB - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 16 − 40)- Range
- -40 to 4055 °C
- Unit
- °C
In testing for 1990 to 2006.
Traction battery overcurrent INFINITI_TRACTION_BAT_OVERCURRENT
- Request
22 92 16 - Service 22
DID 9216 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Traction battery overheating INFINITI_TRACTION_BAT
- Request
22 92 16 - Service 22
DID 9216 - Module
DADB → DAF1DB - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 1990 to 2006.
Traction battery service plug interlock INFINITI_TRACTION_BAT_SERVICE
- Request
22 91 F6 - Service 22
DID 91F6 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1990 to 2006.
Traction battery state of charge INFINITI_TRACTION_BAT_SOC
Pelican can show this parameter as the state of charge.
- Request
22 90 01 - Service 22
DID 9001 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100 − 3)- Range
- -3 to 652 %
- Unit
- %
In testing for 1990 to 2006.
Traction battery total mileage INFINITI_TRACTION_BAT_TOT
- Request
22 91 CF - Service 22
DID 91CF - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 32 + 67108864)- Range
- 0 to 134217727 km
- Unit
- km
In testing for 1990 to 2006.
Traction battery voltage INFINITI_HVBAT_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 90 06 - Service 22
DID 9006 - Module
DADB → DAF1DB - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits. The value is signed.
- Formula
(val ÷ 1024)- Range
- 0 to 1000 V
- Unit
- V
In testing for 1990 to 2006.
Upstream oxygen sensor voltage INFINITI_UP_OXYGEN_SENS_V
- Request
22 12 25 - Service 22
DID 1225 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327 V
- Unit
- V
In testing for 1990 to 2006.
Battery › Cells
HV battery cell 1 voltage INFINITI_HVBAT_CELL_1_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 2 voltage INFINITI_HVBAT_CELL_2_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 3 voltage INFINITI_HVBAT_CELL_3_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 4 voltage INFINITI_HVBAT_CELL_4_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 5 voltage INFINITI_HVBAT_CELL_5_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 6 voltage INFINITI_HVBAT_CELL_6_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 7 voltage INFINITI_HVBAT_CELL_7_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 8 voltage INFINITI_HVBAT_CELL_8_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 9 voltage INFINITI_HVBAT_CELL_9_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 10 voltage INFINITI_HVBAT_CELL_10_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 11 voltage INFINITI_HVBAT_CELL_11_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 12 voltage INFINITI_HVBAT_CELL_12_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 13 voltage INFINITI_HVBAT_CELL_13_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 14 voltage INFINITI_HVBAT_CELL_14_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 15 voltage INFINITI_HVBAT_CELL_15_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 16 voltage INFINITI_HVBAT_CELL_16_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 17 voltage INFINITI_HVBAT_CELL_17_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 18 voltage INFINITI_HVBAT_CELL_18_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 19 voltage INFINITI_HVBAT_CELL_19_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 20 voltage INFINITI_HVBAT_CELL_20_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 21 voltage INFINITI_HVBAT_CELL_21_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 22 voltage INFINITI_HVBAT_CELL_22_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 23 voltage INFINITI_HVBAT_CELL_23_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 24 voltage INFINITI_HVBAT_CELL_24_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 368 to 383 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 25 voltage INFINITI_HVBAT_CELL_25_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 384 to 399 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 26 voltage INFINITI_HVBAT_CELL_26_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 400 to 415 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 27 voltage INFINITI_HVBAT_CELL_27_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 416 to 431 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 28 voltage INFINITI_HVBAT_CELL_28_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 29 voltage INFINITI_HVBAT_CELL_29_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 448 to 463 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 30 voltage INFINITI_HVBAT_CELL_30_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 464 to 479 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 31 voltage INFINITI_HVBAT_CELL_31_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 480 to 495 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 32 voltage INFINITI_HVBAT_CELL_32_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 496 to 511 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 33 voltage INFINITI_HVBAT_CELL_33_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 512 to 527 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 34 voltage INFINITI_HVBAT_CELL_34_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 528 to 543 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 35 voltage INFINITI_HVBAT_CELL_35_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 544 to 559 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 36 voltage INFINITI_HVBAT_CELL_36_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 560 to 575 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 37 voltage INFINITI_HVBAT_CELL_37_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 576 to 591 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 38 voltage INFINITI_HVBAT_CELL_38_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 592 to 607 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 39 voltage INFINITI_HVBAT_CELL_39_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 608 to 623 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 40 voltage INFINITI_HVBAT_CELL_40_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 624 to 639 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 41 voltage INFINITI_HVBAT_CELL_41_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 640 to 655 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 42 voltage INFINITI_HVBAT_CELL_42_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 656 to 671 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 43 voltage INFINITI_HVBAT_CELL_43_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 672 to 687 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 44 voltage INFINITI_HVBAT_CELL_44_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 688 to 703 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 45 voltage INFINITI_HVBAT_CELL_45_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 704 to 719 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 46 voltage INFINITI_HVBAT_CELL_46_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 720 to 735 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 47 voltage INFINITI_HVBAT_CELL_47_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 736 to 751 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 48 voltage INFINITI_HVBAT_CELL_48_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 752 to 767 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 49 voltage INFINITI_HVBAT_CELL_49_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 768 to 783 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 50 voltage INFINITI_HVBAT_CELL_50_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 784 to 799 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 51 voltage INFINITI_HVBAT_CELL_51_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 800 to 815 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 52 voltage INFINITI_HVBAT_CELL_52_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 816 to 831 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 53 voltage INFINITI_HVBAT_CELL_53_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 832 to 847 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 54 voltage INFINITI_HVBAT_CELL_54_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 848 to 863 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 55 voltage INFINITI_HVBAT_CELL_55_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 864 to 879 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 56 voltage INFINITI_HVBAT_CELL_56_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 880 to 895 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 57 voltage INFINITI_HVBAT_CELL_57_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 896 to 911 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 58 voltage INFINITI_HVBAT_CELL_58_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 912 to 927 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 59 voltage INFINITI_HVBAT_CELL_59_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 928 to 943 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 60 voltage INFINITI_HVBAT_CELL_60_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 944 to 959 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 61 voltage INFINITI_HVBAT_CELL_61_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 960 to 975 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 62 voltage INFINITI_HVBAT_CELL_62_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 976 to 991 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 63 voltage INFINITI_HVBAT_CELL_63_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 992 to 1,007 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 64 voltage INFINITI_HVBAT_CELL_64_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,008 to 1,023 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 65 voltage INFINITI_HVBAT_CELL_65_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,024 to 1,039 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 66 voltage INFINITI_HVBAT_CELL_66_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,040 to 1,055 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 67 voltage INFINITI_HVBAT_CELL_67_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,056 to 1,071 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 68 voltage INFINITI_HVBAT_CELL_68_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,072 to 1,087 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 69 voltage INFINITI_HVBAT_CELL_69_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,088 to 1,103 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 70 voltage INFINITI_HVBAT_CELL_70_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,104 to 1,119 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 71 voltage INFINITI_HVBAT_CELL_71_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,120 to 1,135 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 72 voltage INFINITI_HVBAT_CELL_72_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,136 to 1,151 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 73 voltage INFINITI_HVBAT_CELL_73_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,152 to 1,167 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 74 voltage INFINITI_HVBAT_CELL_74_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,168 to 1,183 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 75 voltage INFINITI_HVBAT_CELL_75_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,184 to 1,199 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 76 voltage INFINITI_HVBAT_CELL_76_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,200 to 1,215 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 77 voltage INFINITI_HVBAT_CELL_77_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,216 to 1,231 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 78 voltage INFINITI_HVBAT_CELL_78_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,232 to 1,247 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 79 voltage INFINITI_HVBAT_CELL_79_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,248 to 1,263 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 80 voltage INFINITI_HVBAT_CELL_80_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,264 to 1,279 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 81 voltage INFINITI_HVBAT_CELL_81_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,280 to 1,295 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 82 voltage INFINITI_HVBAT_CELL_82_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,296 to 1,311 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 83 voltage INFINITI_HVBAT_CELL_83_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,312 to 1,327 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 84 voltage INFINITI_HVBAT_CELL_84_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,328 to 1,343 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 85 voltage INFINITI_HVBAT_CELL_85_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,344 to 1,359 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 86 voltage INFINITI_HVBAT_CELL_86_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,360 to 1,375 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 87 voltage INFINITI_HVBAT_CELL_87_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,376 to 1,391 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 88 voltage INFINITI_HVBAT_CELL_88_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,392 to 1,407 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 89 voltage INFINITI_HVBAT_CELL_89_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,408 to 1,423 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 90 voltage INFINITI_HVBAT_CELL_90_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,424 to 1,439 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 91 voltage INFINITI_HVBAT_CELL_91_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,440 to 1,455 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 92 voltage INFINITI_HVBAT_CELL_92_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,456 to 1,471 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 93 voltage INFINITI_HVBAT_CELL_93_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,472 to 1,487 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 94 voltage INFINITI_HVBAT_CELL_94_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,488 to 1,503 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 95 voltage INFINITI_HVBAT_CELL_95_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,504 to 1,519 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
HV battery cell 96 voltage INFINITI_HVBAT_CELL_96_V_V2
- Request
21 02 - Service 21
PID 02 - Module
79B → 7BB - Every
30 s - Testing
Bits 1,520 to 1,535 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 1990 to 2006.
Battery › Draw
Power used by air conditioning INFINITI_AC_PWR_EST
- Request
22 12 61 - Service 22
DID 1261 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 50)- Range
- 0 to 12750 W
- Unit
- W
In testing for 1990 to 2006.
Power used by auxiliary equipment (lights, radio, navigation, rear defroster, etc...). INFINITI_AUX_PWR
- Request
22 11 52 - Service 22
DID 1152 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100)- Range
- 0 to 25500 W
- Unit
- W
In testing for 1990 to 2006.
Power used by both the A/C and PTC heater. INFINITI_AC_PWR
- Request
22 11 51 - Service 22
DID 1151 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 250)- Range
- 0 to 63750 W
- Unit
- W
In testing for 1990 to 2006.
Power used by cabin positive temperature coefficient (PTC) heaters. INFINITI_HTR_PWR
- Request
22 12 62 - Service 22
DID 1262 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 250)- Range
- 0 to 63750 W
- Unit
- W
In testing for 1990 to 2006.
Battery › Statistics
Quick charge count INFINITI_L1L2CHRG_CNT
Increments each time an L1/L2 charge occurs, even if only partially.
- Request
22 12 05 - Service 22
DID 1205 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2006.
Quick charge count INFINITI_QCKCHRG_CNT
Increments each time a quick charge occurs, even if only partially.
- Request
22 12 03 - Service 22
DID 1203 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1990 to 2006.