Engine parameters
The INFINITI G37 has 108 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
Absolute load value LOAD_ABSSAE J1979Confirmed
- Request
01 43 - Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2008. Supported for 2010, 2013.
Air conditioning compressor INFINITI_AC_COMP
- Request
22 13 07 - Service 22
DID 1307 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2013.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2008.
All-wheel drive coupling temperature INFINITI_AWD_COUPLING_T
- Request
22 11 14 - Service 22
DID 1114 - Module
748 → 768 - Every
5 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2013.
All-wheel drive electronic traction support solenoid INFINITI_AWD_ELECTRONIC
- Request
22 11 03 - Service 22
DID 1103 - Module
748 → 768 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
(val ÷ 50)- Range
- 0 to 0.02
- Unit
- Off or on
In testing for 2008 to 2013.
All-wheel drive estimated engine torque INFINITI_AWD_ESTIMATED_ENG_TQ
- Request
22 11 05 - Service 22
DID 1105 - Module
748 → 768 - Every
250 ms - Testing
Bit 7 of the reply. The value is signed.
- Formula
(val × 5 ÷ 2)- Range
- -2.5 to 0
- Unit
- Off or on
In testing for 2008 to 2013.
All-wheel drive request engine torque INFINITI_AWD_REQ_ENG_TQ
- Request
22 11 04 - Service 22
DID 1104 - Module
748 → 768 - Every
250 ms - Testing
Bit 7 of the reply. The value is signed.
- Formula
(val × 5 ÷ 2)- Range
- -2.5 to 0
- Unit
- Off or on
In testing for 2008 to 2013.
Auto emergency braking system request INFINITI_AUTO_EMERGENCY
- Request
22 21 70 - Service 22
DID 2170 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2013.
AWD, target traction control torque INFINITI_AWD_TGT_TRACTION
- Request
22 11 07 - Service 22
DID 1107 - Module
748 → 768 - Every
250 ms - Testing
Bit 7 of the reply.
- Formula
(val × 2)- Range
- 0 to 2
- Unit
- Off or on
In testing for 2008 to 2013.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2008. Supported for 2010, 2013.
Base injection timing INFINITI_BASE_INJ_TIM
- Request
22 12 07 - Service 22
DID 1207 - Module
DA18 → 18 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2048)- Range
- 0 to 31.99 ms
- Unit
- ms
In testing for 2008 to 2013.
Braking detected multiplex signal INFINITI_BRAKING_DETECTED
- Request
22 20 0F - Service 22
DID 200F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2013.
Butane percentage INFINITI_BUTANE_PERCENTAGE
- Request
21 AD - Service 21
PID AD - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val × 7813 ÷ 20000)- Range
- 0 to 99.61 %
- Unit
- %
In testing for 2008 to 2013.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2008, 2013. Supported for 2010.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2008, 2013. Supported for 2010.
Catalyst temperature bank 2, sensor 1 CATEMP21SAE J1979Confirmed
- Request
01 3D - Service 01
PID 3D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2008, 2013. Supported for 2010.
Cold starting programming INFINITI_COLD_STARTING
- Request
21 AD - Service 21
PID AD - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2013.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2008. Supported for 2010, 2013.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Request
01 2E - Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2008. Supported for 2010, 2013.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2008. Supported for 2010, 2013.
Coolant temperature INFINITI_ECT_7E0
- Request
22 14 06 - Service 22
DID 1406 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2008 to 2013.
Cooling fan high INFINITI_COOLING_FAN_HIGH
- Request
22 13 13 - Service 22
DID 1313 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2013.
Cooling fan low INFINITI_COOLING_FAN_LOW
- Request
22 13 13 - Service 22
DID 1313 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2013.
Cruise control INFINITI_CRUISE_CTRL
- Request
22 20 79 - Service 22
DID 2079 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2013.
Duration of - button press INFINITI_DUR_BUTTON_PRESS_7E0
- Request
22 20 7C - Service 22
DID 207C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3276 s
- Unit
- s
In testing for 2008 to 2013.
Duration of + button press INFINITI_DUR_BUTTON_PRESS
- Request
22 20 7B - Service 22
DID 207B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3276 s
- Unit
- s
In testing for 2008 to 2013.
Duration of resume button press INFINITI_DUR_RESUME_BUTTON
- Request
22 20 7A - Service 22
DID 207A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3276 s
- Unit
- s
In testing for 2008 to 2013.
Duration of suspend button press INFINITI_DUR_SUSPEND_BUTTON
- Request
22 20 7D - Service 22
DID 207D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3276 s
- Unit
- s
In testing for 2008 to 2013.
Electric fuel pump learning value INFINITI_EFP_LEARNING
- Request
21 AD - Service 21
PID AD - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
(val ÷ 65535 − 0.5)- Range
- -0.5 to 0.5 %
- Unit
- %
In testing for 2008 to 2013.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2008, 2013. Supported for 2010.
Engine oil temperature INFINITI_EOT
- Request
22 11 1F - Service 22
DID 111F - Module
DA18 → 18 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2008 to 2013.
Engine RPM INFINITI_RPM
- Request
22 12 55 - Service 22
DID 1255 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32767 to 32767
- Unit
- Number
In testing for 2009, 2011 to 2012. Not supported for 2008, 2010, 2013.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2008. Supported for 2010, 2013.
Engine torque INFINITI_ENG_TQ
- Request
22 20 04 - Service 22
DID 2004 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 400)- Range
- -400 to 32367 N·m
- Unit
- N·m
In testing for 2008 to 2013.
Evap system vapor pressure EVAP_VPSAE J1979Confirmed
The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.
- Request
01 32 - Service 01
PID 32 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 4000)- Range
- -8192 to 8191.75 kPa
- Unit
- kPa
Confirmed for 2008. Supported for 2010, 2013.
Front pinion angle INFINITI_FRONT_PINION_ANG
- Request
21 01 - Service 21
PID 01 - Module
75C → 77C - Every
250 ms - Testing
Bits 208 to 223 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °
- Unit
- °
In testing for 2008 to 2013.
Gear INFINITI_GEAR
- Request
22 11 56 - Service 22
DID 1156 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | PARK | Park |
2 | REVERSE | Reverse |
3 | NEUTRAL | Neutral |
4 | DRIVE | Drive |
7 | ECO | Eco |
In testing for 2009, 2011 to 2012. Not supported for 2008, 2010, 2013.
Head lamp INFINITI_HEAD_LAMP
- Request
21 01 - Service 21
PID 01 - Module
75C → 77C - Every
250 ms - Testing
Bit 56 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2013.
Headlamp level INFINITI_HEADLAMP_LEVEL
- Request
21 01 - Service 21
PID 01 - Module
75C → 77C - Every
250 ms - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 49 ÷ 125)- Range
- 0 to 25689 %
- Unit
- %
In testing for 2008 to 2013.
Height sensor initial value front INFINITI_HEIGHT_SENS_INIT_FRONT
- Request
21 01 - Service 21
PID 01 - Module
75C → 77C - Every
250 ms - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val × 5 ÷ 1024)- Range
- 0 to 319.99 V
- Unit
- V
In testing for 2008 to 2013.
Height sensor initial value rear INFINITI_HEIGHT_SENS_INIT
- Request
21 01 - Service 21
PID 01 - Module
75C → 77C - Every
250 ms - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 5 ÷ 1024)- Range
- 0 to 319.99 V
- Unit
- V
In testing for 2008 to 2013.
Height sensor signal front INFINITI_HEIGHT_SENS_SIG
- Request
21 01 - Service 21
PID 01 - Module
75C → 77C - Every
250 ms - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val × 5 + 1024)- Range
- 0 to 328699 V
- Unit
- V
In testing for 2008 to 2013.
Height sensor signal rear INFINITI_HEIGHT_SENS_SIG_REAR
- Request
21 01 - Service 21
PID 01 - Module
75C → 77C - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 5 + 1024)- Range
- 0 to 328699 V
- Unit
- V
In testing for 2008 to 2013.
Idle control mode INFINITI_IDLE_CTRL_MODE
- Request
22 13 07 - Service 22
DID 1307 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2013.
Ignition advance INFINITI_IGN_ADVANCE
- Request
22 11 3C - Service 22
DID 113C - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × -1 + 112)- Range
- -143 to 112
- Unit
- Number
In testing for 2008 to 2013.
Ih_defactrposition INFINITI_IH_DEFACTRPOSITION
- Request
21 53 - Service 21
PID 53 - Module
744 → 764 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2013.
Ih_feetventactrposition INFINITI_IH
- Request
21 53 - Service 21
PID 53 - Module
744 → 764 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2013.
Ih_leftmixactrposition INFINITI_IH_LEFTMIXACTRPOSITION
- Request
21 53 - Service 21
PID 53 - Module
744 → 764 - Every
1 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2013.
Ih_rearmixactrposition INFINITI_IH_REARMIXACTRPOSITION
- Request
21 53 - Service 21
PID 53 - Module
744 → 764 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2013.
Ih_recyactrposition INFINITI_IH_RECYACTRPOSITION
- Request
21 53 - Service 21
PID 53 - Module
744 → 764 - Every
1 s - Testing
Bits 16 to 23 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2013.
Ih_reserveactrposition INFINITI_IH_RESERVEACTRPOSITION
- Request
21 53 - Service 21
PID 53 - Module
744 → 764 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2013.
Ih_rightmixactrposition INFINITI_IH_RIGHTMIXACTRPOSITION
- Request
21 53 - Service 21
PID 53 - Module
744 → 764 - Every
1 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2013.
Intake air temperature IATSAE J1979Confirmed
- Request
01 0F - Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2008, 2013. Supported for 2010.
Intake camshaft advance, bank 2 INFINITI_CAM_ADV_B2
- Request
22 11 37 - Service 22
DID 1137 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2008 to 2013.
Intake valve timing solenoid duty, bank 2 INFINITI_CAM_DUTY_B2
- Request
22 11 39 - Service 22
DID 1139 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 25 ÷ 64)- Range
- 0 to 99.6 %
- Unit
- %
In testing for 2008 to 2013.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Request
01 07 - Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2008. Supported for 2010, 2013.
Long term fuel trim (bank 2) LONGFT2SAE J1979Confirmed
- Request
01 09 - Service 01
PID 09 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2008. Supported for 2010, 2013.
Low-pressure fuel pump drive duty INFINITI_LPLI_PMP_PWM_SIG
- Request
21 AD - Service 21
PID AD - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val × 0.0015259)- Range
- 0 to 99.99 %
- Unit
- %
In testing for 2008 to 2013.
Manifold pressure INFINITI_MANIFOLD_P
- Request
22 14 0E - Service 22
DID 140E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 1000)- Range
- 0 to 255000
- Unit
- Raw value
In testing for 2008 to 2013.
Manual or assisted parking brake INFINITI_MANUAL_OR_ASSISTED
- Request
22 22 2B - Service 22
DID 222B - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2013.
Mass Air Flow Sensor A MAFASAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 66 - Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 g/s
- Unit
- g/s
Confirmed for 2013. Supported for 2010.
Mass Air Flow Sensor B MAFBSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 66 - Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bits 24 to 39 of the reply, 16 bits.
- Formula
(val ÷ 32)- Range
- 0 to 2047.96875 g/s
- Unit
- g/s
Confirmed for 2013. Supported for 2010.
Mass air flow sensor voltage, bank 2 INFINITI_MAF_V_B2
- Request
22 12 05 - Service 22
DID 1205 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 200)- Range
- 0 to 327 V
- Unit
- V
In testing for 2008 to 2013.
Motor power INFINITI_MOTOR_PWR
- Request
22 11 46 - Service 22
DID 1146 - Module
797 → 79A - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 40)- Range
- 0 to 2621400 W
- Unit
- W
In testing for 2009, 2011 to 2012. Not supported for 2008, 2010, 2013.
Motor torque, actual INFINITI_MOTOR_TQ
- Request
22 12 54 - Service 22
DID 1254 - Module
797 → 79A - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.984 N·m
- Unit
- N·m
In testing for 2008 to 2013.
Motor torque, nominal INFINITI_MOTOR_TQ_NOMINAL
- Request
22 11 28 - Service 22
DID 1128 - Module
797 → 79A - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 64)- Range
- -512 to 511.984 N·m
- Unit
- N·m
In testing for 2008 to 2013.
Number of abnormal cc/sl transitions INFINITI_NUM_ABNORMAL_CC_SL
- Request
22 20 7E - Service 22
DID 207E - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2013.
Oh_defactrreq INFINITI_OH_DEFACTRREQ
- Request
21 53 - Service 21
PID 53 - Module
744 → 764 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2013.
Oh_feetventactrreq INFINITI_OH_FEETVENTACTRREQ
- Request
21 53 - Service 21
PID 53 - Module
744 → 764 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2013.
Oh_leftmixactrreq INFINITI_OH_LEFTMIXACTRREQ
- Request
21 53 - Service 21
PID 53 - Module
744 → 764 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2013.
Oh_rearmixactrreq INFINITI_OH_REARMIXACTRREQ
- Request
21 53 - Service 21
PID 53 - Module
744 → 764 - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2013.
Oh_recyactrreq INFINITI_OH_RECYACTRREQ
- Request
21 53 - Service 21
PID 53 - Module
744 → 764 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2013.
Oh_reserveactrreq INFINITI_OH_RESERVEACTRREQ
- Request
21 53 - Service 21
PID 53 - Module
744 → 764 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2013.
Oh_rightmixactrreq INFINITI_OH_RIGHTMIXACTRREQ
- Request
21 53 - Service 21
PID 53 - Module
744 → 764 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2008 to 2013.
Power switch INFINITI_IGN
- Request
22 13 04 - Service 22
DID 1304 - Module
797 → 79A - Every
1 s - Testing
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2009, 2011 to 2012. Not supported for 2008, 2010, 2013.
Reverse INFINITI_REVERSE
- Request
21 01 - Service 21
PID 01 - Module
75C → 77C - Every
250 ms - Testing
Bit 57 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2013.
Selector position INFINITI_SELECTOR_POS
- Request
21 01 - Service 21
PID 01 - Module
75C → 77C - Every
250 ms - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2008 to 2013.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2008. Supported for 2010, 2013.
Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 08 - Service 01
PID 08 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2008. Supported for 2010, 2013.
Starter button INFINITI_STARTER_BUTTON
- Request
22 20 79 - Service 22
DID 2079 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2013.
Starter wear counter INFINITI_STARTER_WEAR_CNT
- Request
22 22 AA - Service 22
DID 22AA - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 40 to 63 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215
- Unit
- Number
In testing for 2008 to 2013.
Steer angle INFINITI_STEER_ANG
- Request
21 01 - Service 21
PID 01 - Module
75C → 77C - Every
250 ms - Testing
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 °
- Unit
- °
In testing for 2008 to 2013.
Swivel angle left INFINITI_SWIVEL_ANG_LEFT
- Request
21 01 - Service 21
PID 01 - Module
75C → 77C - Every
250 ms - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 10 − 32000)- Range
- -32000 to -25447 °
- Unit
- °
In testing for 2008 to 2013.
Swivel angle right INFINITI_SWIVEL_ANG_RIGHT
- Request
21 01 - Service 21
PID 01 - Module
75C → 77C - Every
250 ms - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 10 − 32000)- Range
- -32000 to -25447 °
- Unit
- °
In testing for 2008 to 2013.
Swivel sensor left INFINITI_SWIVEL_SENS_LEFT
- Request
21 01 - Service 21
PID 01 - Module
75C → 77C - Every
250 ms - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 10 − 32000)- Range
- -32000 to -25447 °
- Unit
- °
In testing for 2008 to 2013.
Swivel sensor right INFINITI_SWIVEL_SENS_RIGHT
- Request
21 01 - Service 21
PID 01 - Module
75C → 77C - Every
250 ms - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 10 − 32000)- Range
- -32000 to -25447 °
- Unit
- °
In testing for 2008 to 2013.
Tank pressure INFINITI_TANK_P
- Request
21 AD - Service 21
PID AD - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767
- Unit
- Raw value
In testing for 2008 to 2013.
Throttle opening INFINITI_THROTTLE_OPENING
- Request
22 14 0F - Service 22
DID 140F - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 7 ÷ 20)- Range
- 0 to 89.25 °
- Unit
- °
In testing for 2008 to 2013.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2008, 2013. Supported for 2010.
Traction control/anti-yaw control INFINITI_TRACTION_CTRL_ANTI
- Request
22 20 79 - Service 22
DID 2079 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2013.
Vapor lock temperature INFINITI_VAPOR_LOCK_T
- Request
21 AD - Service 21
PID AD - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2008 to 2013.
Variable valve timing oil temperature INFINITI_VVT_EOT
- Request
22 12 66 - Service 22
DID 1266 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 3 ÷ 128 − 273)- Range
- -273 to 1262 °C
- Unit
- °C
In testing for 2008 to 2013.
Engine › Internal
MAF Sensor A supported MAFA_SUPSAE J1979Confirmed
- Request
01 66 - Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013. Supported for 2010.
MAF Sensor B supported MAFB_SUPSAE J1979Confirmed
- Request
01 66 - Service 01
PID 66 - Module
7E0 → 7E8 - Every
250 ms
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013. Supported for 2010.
Engine › OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013. Supported for 2008, 2010.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013. Supported for 2008, 2010.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013. Supported for 2008, 2010.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013. Supported for 2008, 2010.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013. Supported for 2008, 2010.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013. Supported for 2008, 2010.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013. Supported for 2008, 2010.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2013. Supported for 2008, 2010.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_VOLTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2008, 2013. Supported for 2010.
O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed
- Request
01 15 - Service 01
PID 15 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2013. Supported for 2008, 2010.
O2S Output Voltage Bank 2, Sensor 2 O2S22SAE J1979Confirmed
- Request
01 19 - Service 01
PID 19 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 200)- Range
- 0 to 1.275 V
- Unit
- V
Confirmed for 2013. Supported for 2008, 2010.
SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed
- Request
01 14 - Service 01
PID 14 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 128)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2013. Supported for 2008, 2010.
SHRTFT associated with O2S22 SHRTFT22SAE J1979Confirmed
- Request
01 19 - Service 01
PID 19 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 128)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2013. Supported for 2008, 2010.
Wide Range O2S Voltage, O2 Sensor Bank 1, Sensor 1 O2S11_VOLTSAE J1979Confirmed
- Request
01 24 - Service 01
PID 24 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 8196)- Range
- 0 to 7.999 V
- Unit
- V
Confirmed for 2008, 2013. Supported for 2010.