Hyundai Veloster

Climate parameters

The Hyundai Veloster has 9 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Defogging? VELOSTER_DEFOG_SWConfirmed

  • Request22 BC 03
  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing for 2011 to 2018, 2022

Example reply from a 2021 Hyundai Veloster.

Bit 62 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019 to 2021. In testing for 2011 to 2016, 2018, 2022. Not supported for 2017.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Ambient temperature, vehicle control unit VELOSTER_AAT_VMCU

  • Request21 80
  • Service 21PID 80
  • Module7E6 → 7EE
  • Every30 s
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 2 − 40)
Range
-104 to 23.5 °C
Unit
°C

In testing for 2011 to 2022.

Defog light on VELOSTER_DEFOG_LIGHTConfirmed

  • Request22 BC 07
  • Service 22DID BC07
  • Module770 → 778
  • Every1 s
  • Testing for 2011 to 2018, 2022

Bits 40 to 47 of the reply, 8 bits.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019 to 2021. In testing for 2011 to 2016, 2018, 2022. Not supported for 2017.

Defogging? VELOSTER_DEFOG_SWConfirmed

  • Request22 BC 03
  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing for 2011 to 2018, 2022

Example reply from a 2021 Hyundai Veloster.

Bit 62 of the reply.

0b0 = 0 → 0

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2019 to 2021. In testing for 2011 to 2016, 2018, 2022. Not supported for 2017.

Exterior temperature VELOSTER_TEMP_EXTConfirmed

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2011 to 2019, 2021 to 2022

Example reply from a 2020 Hyundai Veloster.

Bits 48 to 55 of the reply, 8 bits.

0x7C = 124 → (124 ÷ 2 − 40) = 22 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 80 °C
Unit
°C

Confirmed for 2020. In testing for 2011 to 2019, 2021 to 2022.

Heated steering wheel VELOSTER_HEATED_WHEEL

  • Request22 B0 0C
  • Service 22DID B00C
  • Module7A0 → 7A8
  • Every5 s
  • Testing

Bit 34 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2022.

Heated steering wheel, alternate bit VELOSTER_HEATED_WHEEL_ALT

  • Request22 B0 0C
  • Service 22DID B00C
  • Module7A0 → 7A8
  • Every5 s
  • Testing

Bit 42 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2011 to 2022.

Interior temperature VELOSTER_TEMP_INTConfirmed

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every250 ms
  • Testing for 2011 to 2019, 2021 to 2022

Example reply from a 2020 Hyundai Veloster.

Bits 40 to 47 of the reply, 8 bits.

0x89 = 137 → (137 ÷ 2 − 40) = 28.5 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 80 °C
Unit
°C

Confirmed for 2020. In testing for 2011 to 2019, 2021 to 2022.

Interior temperature, passenger legs vent VELOSTER_HVAC_IAT_PASSENGER_LEGS_VENT

  • Request22 01 01
  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2011 to 2022.

Interior temperature, passenger vent VELOSTER_HVAC_IAT_PASSENGER_VENT

  • Request22 01 01
  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2011 to 2022.