Battery parameters
The Hyundai Tucson has 55 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12v battery charge TUCSON_VPWR_V3
- Request
22 E0 04 - Service 22
DID E004 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
12V battery state of charge TUCSON_BATTERY_SOCConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing for 2004 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Hyundai Tucson.
Bits 48 to 55 of the reply, 8 bits.
0x4C = 76 → 76 %
- Formula
val- Range
- 0 to 255 %
- Unit
- %
Confirmed for 2022, 2024. In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018.
48 battery state of charge TUCSON_48_BAT_ST_CHG
- Request
22 02 01 - Service 22
DID 0201 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
48 battery state of charge 2 TUCSON_48_BAT_ST_CHG_2
- Request
22 02 05 - Service 22
DID 0205 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
48V battery charge limit TUCSON_48V_BAT_CHG_LIM
- Request
22 02 05 - Service 22
DID 0205 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 216 to 231 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 A
- Unit
- A
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
48V battery current TUCSON_48V_BAT_CURRENT_7E4
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 A
- Unit
- A
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
48V battery current monitoring TUCSON_48V_BAT_CURRENT
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 A
- Unit
- A
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
48V battery voltage TUCSON_48V_BAT_V
- Request
22 02 05 - Service 22
DID 0205 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 328 to 343 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Aux battery state of charge TUCSON_AUX_SOC
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s - Testing for 2004 to 2021, 2023, 2025 to 2026
Bits 320 to 327 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Supported for 2022, 2024. Not supported for 2018.
Aux battery state of health TUCSON_AUX_SOH
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s - Testing for 2004 to 2021, 2023, 2025 to 2026
Bits 328 to 335 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Supported for 2022, 2024. Not supported for 2018.
Battery capacity, battery sensor TUCSON_BAT_CAP_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 Ah
- Unit
- Ah
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery charge flag, battery sensor TUCSON_BAT_CHG_FLAG_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 183 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery current TUCSON_BAT_CURRENT
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 256 to 271 of the reply, 16 bits. The value is signed.
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7 A
- Unit
- A
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery current, battery sensor TUCSON_BAT_CURRENT_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 A
- Unit
- A
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery current, battery sensor TUCSON_BAT_CURRENT_BATSENS_7E0
- Request
21 27 - Service 21
PID 27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 A
- Unit
- A
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery health aging flag, battery sensor TUCSON_BAT_HEALTH_AGING
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 182 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery is in use to crank the engine flag, battery sensor TUCSON_BAT_CRANK_ENG_FLAG
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 181 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery quiescent current flag, battery sensor TUCSON_BAT_QUIESCENT
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 180 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery sensor invalid condition flag, battery sensor TUCSON_BATSENS_INVALID_COND
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 179 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery state of charge, battery sensor TUCSON_BAT_ST_CHG_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery state of charge, battery sensor TUCSON_BAT_ST_CHG_BATSENS_7E0
- Request
21 27 - Service 21
PID 27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery state of function, battery sensor TUCSON_BAT_ST_FUNCTION
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 12.75 ÷ 255)- Range
- 0 to 12.75 V
- Unit
- V
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery state of function, battery sensor TUCSON_BAT_ST_FUNCTION_BATSENS
- Request
21 27 - Service 21
PID 27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 20)- Range
- 0 to 12.75 V
- Unit
- V
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery state of health, battery sensor TUCSON_BAT_ST_HEALTH
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery temperature TUCSON_BAT_T
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 °C
- Unit
- °C
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery temperature 1 TUCSON_BAT_T_1
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery temperature 2 TUCSON_BAT_T_2
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 112 to 127 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery temperature, battery sensor TUCSON_BAT_T_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery temperature, battery sensor TUCSON_BAT_T_BATSENS_7E0
- Request
21 27 - Service 21
PID 27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 32727 °C
- Unit
- °C
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery voltage TUCSON_BAT_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val × 10 ÷ 10000 + 6)- Range
- 0 to 71.535 V
- Unit
- V
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery voltage TUCSON_BATTERY_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing for 2004 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Hyundai Tucson.
Bits 32 to 39 of the reply, 8 bits.
0xB8 = 184 → (184 × 17.37 ÷ 255) = 12.533647 V
- Formula
(val × 17.37 ÷ 255)- Range
- 0 to 17.37 V
- Unit
- V
Confirmed for 2022, 2024. In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018.
Battery voltage after ignition TUCSON_BATTERY_V_AFTER_IGNITIONConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing for 2004 to 2021, 2023, 2025 to 2026
Example reply from a 2024 Hyundai Tucson.
Bits 40 to 47 of the reply, 8 bits.
0x00 = 0 → (0 × 17.37 ÷ 255) = 0 V
- Formula
(val × 17.37 ÷ 255)- Range
- 0 to 17.37 V
- Unit
- V
Confirmed for 2022, 2024. In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018.
Battery voltage, battery sensor TUCSON_BAT_V_BATSENS
Pelican can show this parameter as the starter battery voltage.
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 12.75 ÷ 255 + 6)- Range
- 0 to 18.75 V
- Unit
- V
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Battery voltage, battery sensor TUCSON_BAT_V_BATSENS_7E0
Pelican can show this parameter as the starter battery voltage.
- Request
21 27 - Service 21
PID 27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 6)- Range
- 0 to 71.53 V
- Unit
- V
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Control module voltage TUCSON_CONTROL_MODULE_VOLTAGEConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2004 to 2017, 2019 to 2026
Example reply from a 2018 Hyundai Tucson.
Bits 40 to 47 of the reply, 8 bits.
0xCC = 204 → 204 V
- Formula
val- Range
- 0 to 255 V
- Unit
- V
Confirmed for 2018. In testing for 2004 to 2017, 2019 to 2021. Not supported for 2022.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2015 to 2016, 2018 to 2019, 2023 to 2025. Supported for 2008, 2014, 2020, 2022, 2026.
Control module voltage after ignition TUCSON_CONTROL_MODULE_VOLTAGE_AFTER_IGNITIONConfirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2004 to 2017, 2019 to 2026
Example reply from a 2018 Hyundai Tucson.
Bits 48 to 55 of the reply, 8 bits.
0xB5 = 181 → 181 V
- Formula
val- Range
- 0 to 255 V
- Unit
- V
Confirmed for 2018. In testing for 2004 to 2017, 2019 to 2021. Not supported for 2022.
Coolant temperature sensor voltage TUCSON_COOLANT_T_SENSOR_VOLTAGEConfirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2004 to 2017, 2019 to 2026
Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0048828125)- Range
- 0 to 319 V
- Unit
- V
Confirmed for 2018. In testing for 2004 to 2017, 2019 to 2021. Not supported for 2022.
Current sensor narrow range, volts TUCSON_CURRENT_SENS_NARROW_RANGE
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val × 26651 ÷ 21845000)- Range
- 0 to 79.95 V
- Unit
- V
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Current sensor wide range, volts TUCSON_CURRENT_SENS_WIDE_RANGE
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val × 26651 ÷ 21845000)- Range
- 0 to 79.95 A
- Unit
- A
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Desired alternator voltage duty cycle, battery sensor TUCSON_DES_ALTERNATOR_V
- Request
21 27 - Service 21
PID 27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val × 20 ÷ 13107)- Range
- 0 to 100 %
- Unit
- %
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Gasoline particulate filter charge state TUCSON_GPF_CHG_ST
- Request
22 E0 09 - Service 22
DID E009 - Module
7E0 → 7E8 - Every
30 s - Testing for 2004 to 2021, 2023, 2025 to 2026
Bits 320 to 327 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Supported for 2022, 2024. Not supported for 2018.
Gasoline particulate filter inlet temperature sensor raw voltage TUCSON_GPF_INLET_T_SENS_RAW_V
- Request
22 E0 09 - Service 22
DID E009 - Module
7E0 → 7E8 - Every
30 s - Testing for 2004 to 2021, 2023, 2025 to 2026
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 21333 ÷ 4369000)- Range
- 0 to 319 V
- Unit
- V
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Supported for 2022, 2024. Not supported for 2018.
Gasoline particulate filter outlet temperature sensor raw voltage TUCSON_GPF_OUTLET_T_SENS_V
- Request
22 E0 09 - Service 22
DID E009 - Module
7E0 → 7E8 - Every
30 s - Testing for 2004 to 2021, 2023, 2025 to 2026
Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 21333 ÷ 4369000)- Range
- 0 to 319 V
- Unit
- V
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Supported for 2022, 2024. Not supported for 2018.
IAT sensor voltage TUCSON_IAT_SENSOR_VOLTAGEConfirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2004 to 2017, 2019 to 2026
Example reply from a 2018 Hyundai Tucson.
Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.
0x03FF = 1023 → (1023 × 0.0048828125) = 4.995117 V
- Formula
(val × 0.0048828125)- Range
- 0 to 319 V
- Unit
- V
Confirmed for 2018. In testing for 2004 to 2017, 2019 to 2021. Not supported for 2022.
Manifold absolute pressure sensor voltage TUCSON_MAP_SENSOR_VOLTAGEConfirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing for 2004 to 2017, 2019 to 2026
Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0048828125)- Range
- 0 to 319 V
- Unit
- V
Confirmed for 2018. In testing for 2004 to 2017, 2019 to 2021. Not supported for 2022.
Maximum 48V battery voltage TUCSON_MAX_48V_BAT_V
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Minimum 48V battery voltage TUCSON_MIN_48V_BAT_V
- Request
22 02 04 - Service 22
DID 0204 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 mV
- Unit
- mV
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Relative accelerator pedal position voltage TUCSON_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 V
- Unit
- V
In testing for 2004 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Response error from battery sensor flag, battery sensor TUCSON_RESPONSE_ERROR
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 178 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Supply voltage TUCSON_SUPPLY_VOLTAGE
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
System voltage TUCSON_SYSTEM_VOLTAGE
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.
Throttle position sensor voltage #1 TUCSON_THROTTLE_POSITION_SENSOR_VOLTAGE__1
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0012207031)- Range
- 0 to 79 V
- Unit
- V
In testing for 2004 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Throttle position sensor voltage #2 TUCSON_THROTTLE_POSITION_SENSOR_VOLTAGE__2
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0012207031)- Range
- 0 to 79 V
- Unit
- V
In testing for 2004 to 2017, 2019 to 2021. Not supported for 2018, 2022.
Wastegate position voltage TUCSON_WASTEGATE_POS_V
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- -5.01 to 5.01 V
- Unit
- V
In testing for 2004 to 2017, 2019 to 2021, 2023, 2025 to 2026. Not supported for 2018, 2022, 2024.