Fuel parameters
The Hyundai Kona Electric has 16 fuel parameters.
● Confirmed◆ In testing○ Supported× Not supported
Cycle fuel consumption KONAEV_CYCLE_FUEL_CONS
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 416 to 423 of the reply, 8 bits.
- Formula
(val × 8.478 ÷ 100)- Range
- 0 to 21.6189
- Unit
- Raw value
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Fuel consumption since last DPF regeneration KONAEV_FUEL_CONS_SINCE_DPF
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 432 to 439 of the reply, 8 bits.
- Formula
(val × 1.2549)- Range
- 0 to 319 L
- Unit
- L
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Fuel cut KONAEV_FUEL_CUT
- Request
21 00 - Service 21
PID 00 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Fuel injection timing #1 KONAEV_FUEL_INJECTION_TIMING_1
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Fuel injection timing #2 KONAEV_FUEL_INJECTION_TIMING_2
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Fuel injection timing #3 KONAEV_FUEL_INJECTION_TIMING_3
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Fuel injection timing #4 KONAEV_FUEL_INJECTION_TIMING_4
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Fuel pressure KONAEV_FUEL_P
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 53067 ÷ 10000)- Range
- 0 to 347774.5845
- Unit
- Raw value
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Fuel pressure deviation KONAEV_FUEL_P_DEV
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 53067 ÷ 10000)- Range
- -173889.9456 to 173884.6389
- Unit
- Raw value
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Fuel pressure set point KONAEV_FUEL_P_SET_POINT
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 53067 ÷ 10000)- Range
- 0 to 347774.5845
- Unit
- Raw value
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Fuel pressure set point deviation KONAEV_FUEL_P_SET_POINT_DEV
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 53066 ÷ 10000)- Range
- -173886.6688 to 173881.3622
- Unit
- Raw value
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Fuel pressure, actual KONAEV_FUEL_P_ACT
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 53067 ÷ 10000)- Range
- 0 to 347774.5845
- Unit
- Raw value
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Fuel pressure, set point KONAEV_FUEL_P_SET_POINT_7E0
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 53067 ÷ 10000)- Range
- 0 to 347774.5845
- Unit
- Raw value
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Fuel temperature KONAEV_FUEL_T
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val × 7843 ÷ 10000 − 50)- Range
- -50 to 149.9965 °C
- Unit
- °C
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Short term fuel % trim, bank 1 KONAEV_STFT_B1
- Request
21 15 - Service 21
PID 15 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0030517578 − 100)- Range
- 0 to 99.99 %
- Unit
- %
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.
Short term fuel % trim, bank 1 idle KONAEV_STFT_B1_IDLE
- Request
21 15 - Service 21
PID 15 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.046875)- Range
- 0 to 100 %
- Unit
- %
In testing for 2017 to 2020, 2022 to 2023, 2025 to 2026. Not supported for 2021, 2024.