Battery parameters
The Hyundai Ioniq Electric has 506 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery charge IONIQEV_VPWR_7E2
- Request
22 E0 04 - Service 22
DID E004 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
12V battery state of charge IONIQEV_BATTERY_SOCConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing for 2016, 2019 to 2022
Example reply from a 2018 Hyundai Ioniq Electric.
Bits 48 to 55 of the reply, 8 bits.
0x4F = 79 → 79 %
- Formula
val- Range
- 0 to 255 %
- Unit
- %
Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.
A/C charger current IONIQEV_AC_CHARGER_CURRENT
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 A
- Unit
- A
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
A/C charging counter IONIQEV_HVBAT_AC_CHARGING_COUNTER
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
A/C charging time IONIQEV_VCMS__AC_CHARGING_TIME
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 h
- Unit
- h
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
A/C charging time, after plug-in IONIQEV_AC_CHARGING_TIME_AFTER_PLUG_IN
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Airbag hard-wire duty IONIQEV_AIRBAG_DUTYConfirmed
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 176 to 183 of the reply, 8 bits.
0x50 = 80 → 80
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Aux battery state of charge IONIQEV_AUX_SOC
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s - Testing for 2016, 2019 to 2022
Bits 320 to 327 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2016, 2019 to 2022. Supported for 2017 to 2018.
Aux battery state of health IONIQEV_AUX_SOH
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s - Testing for 2016, 2019 to 2022
Bits 328 to 335 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2016, 2019 to 2022. Supported for 2017 to 2018.
Auxiliary battery current IONIQEV_2025_AUX_BATTERY_CURRENT
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327)- Range
- -327 to 328.35 A
- Unit
- A
In testing for 2016 to 2022.
Auxiliary battery current IONIQEV_AUX_BATTERY_CURRENT
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 100 − 327)- Range
- -327 to 328.35 A
- Unit
- A
In testing for 2016 to 2022.
Auxiliary battery current IONIQEV_AUXILIARY_BAT
- Request
21 02 - Service 21
PID 02 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 A
- Unit
- A
In testing for 2016 to 2022.
Auxiliary battery state of charge IONIQEV_2025_AUX_BATTERY_STATE_OF_CHARGE
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2022.
Auxiliary battery state of charge IONIQEV_AUX_BATTERY_STATE_OF_CHARGE
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2022.
Auxiliary battery state of charge IONIQEV_AUXILIARY_BAT_ST_CHG
- Request
21 02 - Service 21
PID 02 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2016 to 2022.
Auxiliary battery temperature IONIQEV_2025_AUX_BATTERY_T
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 32727.5 °C
- Unit
- °C
In testing for 2016 to 2022.
Auxiliary battery temperature IONIQEV_AUX_BATTERY_T
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 32727.5 °C
- Unit
- °C
In testing for 2016 to 2022.
Auxiliary battery voltage IONIQEV_2025_AUX_BATTERY_VOLTAGE
Pelican can show this parameter as the starter battery voltage.
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 6)- Range
- 6 to 71.535 V
- Unit
- V
In testing for 2016 to 2022.
Auxiliary battery voltage IONIQEV_AUX_BATTERY_VOLTAGE_7E5
Pelican can show this parameter as the starter battery voltage.
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
(val ÷ 1000 + 6)- Range
- 6 to 71.535 V
- Unit
- V
In testing for 2016 to 2022.
Auxiliary battery voltage IONIQEV_AUXILIARY_BAT_V
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2022.
Available charge power IONIQEV_AVAILABLE_CHG_POWER
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 40 to 55 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 kW
- Unit
- kW
In testing for 2016 to 2022.
Available discharge power IONIQEV_AVAILABLE_DCHG_POWER
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 kW
- Unit
- kW
In testing for 2016 to 2022.
Battery auxiliary voltage IONIQEV_VPWR
Pelican can show this parameter as the starter battery voltage.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery capacity, battery sensor IONIQEV_BAT_CAP_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 Ah
- Unit
- Ah
In testing for 2016 to 2022.
Battery cell voltage deviation IONIQEV_HVBAT_C_DEV_VConfirmed
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 160 to 167 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 50) = 0 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery charge flag, battery sensor IONIQEV_BAT_CHG_FLAG_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 183 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Battery current IONIQEV_BAT_CURRENT
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 256 to 271 of the reply, 16 bits. The value is signed.
- Formula
(val × 1000 ÷ 10000)- Range
- -3276.8 to 3276.7 A
- Unit
- A
In testing for 2016 to 2022.
Battery current IONIQEV_BAT_CURRENT_7E4
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 A
- Unit
- A
In testing for 2016 to 2022.
Battery current, battery sensor IONIQEV_BAT_CURRENT_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 A
- Unit
- A
In testing for 2016 to 2022.
Battery DC voltage IONIQEV_BAT_DC_V
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 V
- Unit
- V
In testing for 2016 to 2022.
Battery fan duty feedback IONIQEV_HVBAT_FAN_DUTY
- Request
22 01 06 - Service 22
DID 0106 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2022.
Battery fan feedback IONIQEV_BAT_FAN_FEEDBACK
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 Hz
- Unit
- Hz
In testing for 2016 to 2022.
Battery fan status IONIQEV_BAT_FAN_STAT
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2022.
Battery health aging flag, battery sensor IONIQEV_BAT_HEALTH_AGING
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 182 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Battery heater 1 temperature IONIQEV_HVBAT_HTR1_TConfirmed
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 184 to 191 of the reply, 8 bits. The value is signed.
0x16 = 22 → 22 °C
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery heater 2 temperature IONIQEV_HVBAT_HTR2_TConfirmed
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 192 to 199 of the reply, 8 bits. The value is signed.
0x16 = 22 → 22 °C
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery inlet temperature IONIQEV_BAT_INLET_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 176 to 183 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2016 to 2022.
Battery inlet temperature IONIQEV_HVBAT_INLET_T
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery is in use to crank the engine flag, battery sensor IONIQEV_BAT_CRANK_ENG_FLAG
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 181 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Battery management state IONIQEV_BMS_STATE
- Request
22 01 06 - Service 22
DID 0106 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 15
- Unit
- Number
In testing for 2016 to 2022.
Battery max temperature IONIQEV_BAT_MAX_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2016 to 2022.
Battery min temperature IONIQEV_BAT_MIN_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 120 to 127 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2016 to 2022.
Battery module 01 temperature IONIQEV_BAT_MODULE_01_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 128 to 135 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2016 to 2022.
Battery module 02 temperature IONIQEV_BAT_MODULE_02_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 136 to 143 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2016 to 2022.
Battery module 03 temperature IONIQEV_BAT_MODULE_03_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 144 to 151 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2016 to 2022.
Battery module 04 temperature IONIQEV_BAT_MODULE_04_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 152 to 159 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2016 to 2022.
Battery module 05 temperature IONIQEV_BAT_MODULE_05_T
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 160 to 167 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2016 to 2022.
Battery module 06 temperature IONIQEV_HVBAT_MOD06_TConfirmed
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 72 to 79 of the reply, 8 bits. The value is signed.
0x16 = 22 → 22 °C
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery module 07 temperature IONIQEV_HVBAT_MOD07_TConfirmed
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 80 to 87 of the reply, 8 bits. The value is signed.
0x16 = 22 → 22 °C
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery module 08 temperature IONIQEV_HVBAT_MOD08_TConfirmed
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 88 to 95 of the reply, 8 bits. The value is signed.
0x16 = 22 → 22 °C
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery module 09 temperature IONIQEV_HVBAT_MOD09_TConfirmed
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 96 to 103 of the reply, 8 bits. The value is signed.
0x16 = 22 → 22 °C
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery module 10 temperature IONIQEV_HVBAT_MOD10_TConfirmed
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 104 to 111 of the reply, 8 bits. The value is signed.
0x16 = 22 → 22 °C
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery module 11 temperature IONIQEV_HVBAT_MOD11_TConfirmed
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 112 to 119 of the reply, 8 bits. The value is signed.
0x16 = 22 → 22 °C
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery module 12 temperature IONIQEV_HVBAT_MOD12_TConfirmed
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 120 to 127 of the reply, 8 bits. The value is signed.
0x16 = 22 → 22 °C
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery pack B17 IONIQEV_BATTERY_PACK_B17
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2016 to 2022.
Battery pack B18 IONIQEV_BATTERY_PACK_B18
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 80 °C
- Unit
- °C
In testing for 2016 to 2022.
Battery quiescent current flag, battery sensor IONIQEV_BAT_QUIESCENT
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 180 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Battery sensor invalid condition flag, battery sensor IONIQEV_BATSENS_INVALID_COND
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 179 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Battery state of charge, battery sensor IONIQEV_BAT_ST_CHG_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2022.
Battery state of function, battery sensor IONIQEV_BAT_ST_FUNCTION
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 12.75 ÷ 255)- Range
- 0 to 12.75 V
- Unit
- V
In testing for 2016 to 2022.
Battery state of health, battery sensor IONIQEV_BAT_ST_HEALTH
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2022.
Battery temperature IONIQEV_BAT_T
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5 °C
- Unit
- °C
In testing for 2016 to 2022.
Battery temperature at the power relay assembly IONIQEV_HVBAT_PRA_T
- Request
22 01 06 - Service 22
DID 0106 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 160 to 167 of the reply, 8 bits. The value is signed.
- Formula
(val × 2)- Range
- -256 to 254 °C
- Unit
- °C
In testing for 2016 to 2022.
Battery temperature at WCS input IONIQEV_HVBAT_WCS_INLET_T
- Request
22 01 06 - Service 22
DID 0106 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2016 to 2022.
Battery temperature, battery sensor IONIQEV_BAT_T_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2016 to 2022.
Battery voltage IONIQEV_BAT_V
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
(val × 10 ÷ 10000 + 6)- Range
- 0 to 71.535 V
- Unit
- V
In testing for 2016 to 2022.
Battery voltage IONIQEV_BATTERY_VConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing for 2016, 2019 to 2022
Example reply from a 2018 Hyundai Ioniq Electric.
Bits 32 to 39 of the reply, 8 bits.
0xCE = 206 → (206 × 17.37 ÷ 255) = 14.032235 V
- Formula
(val × 17.37 ÷ 255)- Range
- 0 to 17.37 V
- Unit
- V
Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.
Battery voltage after ignition IONIQEV_BATTERY_V_AFTER_IGNITIONConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing for 2016, 2019 to 2022
Example reply from a 2018 Hyundai Ioniq Electric.
Bits 40 to 47 of the reply, 8 bits.
0xCE = 206 → (206 × 17.37 ÷ 255) = 14.032235 V
- Formula
(val × 17.37 ÷ 255)- Range
- 0 to 17.37 V
- Unit
- V
Confirmed for 2017 to 2018. In testing for 2016, 2019 to 2022.
Battery voltage, battery sensor IONIQEV_BAT_V_BATSENS
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 12.75 ÷ 255 + 6)- Range
- 0 to 18.75 V
- Unit
- V
In testing for 2016 to 2022.
Charge mode A/C maximum current limit IONIQEV_CHARGE_MODE_AC_MAXIMUM_CURRENT_LIMIT
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2016 to 2022.
Charge mode DC maximum current limit IONIQEV_CHARGE_MODE_DC_MAXIMUM_CURRENT_LIMIT
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2016 to 2022.
Charge mode DC target voltage IONIQEV_CHARGE_MODE_DC_TARGET_VOLTAGE
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016 to 2022.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2018.
Control pilot duty cycle IONIQEV_HVBAT_CP_DUTY_CYCLE
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Control pilot voltage IONIQEV_HVBAT_CP_VOLTAGE
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Cumulative charge current IONIQEV_CUM_CHG_CURRENT
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 240 to 271 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2016 to 2022.
Cumulative DC charging time IONIQEV_DC_CHRG_TIME
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 h
- Unit
- h
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Cumulative discharge current IONIQEV_CUM_DCHG_CURRENT
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 272 to 303 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2016 to 2022.
Cumulative energy charged IONIQEV_CUM_ENERGY_CHARGED
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 304 to 335 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 kWh
- Unit
- kWh
In testing for 2016 to 2022.
Cumulative energy discharged IONIQEV_CUM_ENERGY
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 336 to 367 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 kWh
- Unit
- kWh
In testing for 2016 to 2022.
DC charger current capability IONIQEV_DC_CHARGER_CURRENT_CAPABILITY
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 A
- Unit
- A
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
DC charging counter IONIQEV_HVBAT_CHRG_CNT
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
DC charging time, after plug-in IONIQEV_DC_CHARGING_TIME_AFTER_PLUG_IN
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 min
- Unit
- min
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Discharge mode A/C maximum current limit IONIQEV_DISCHARGE_MODE_AC_MAXIMUM_CURRENT_LIMIT
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2016 to 2022.
Discharge mode A/C target voltage IONIQEV_DISCHARGE_MODE_V2L_AC_TARGET_VOLTAGE
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 2016 to 2022.
Discharge mode DC maximum current limit IONIQEV_DISCHARGE_MODE_DC_MAXIMUM_CURRENT_LIMIT
- Request
22 E0 01 - Service 22
DID E001 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2016 to 2022.
Electric oil pump, actual speed IONIQEV_EOP_ACTUAL_SPEED
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 20)- Range
- 0 to 5100 rpm
- Unit
- rpm
In testing for 2016 to 2022.
Electric oil pump, commanded speed IONIQEV_EOP_COMMANDED_SPEED
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val × 20)- Range
- 0 to 5100 rpm
- Unit
- rpm
In testing for 2016 to 2022.
Electric oil pump, current DC IONIQEV_EOP_CURRENT_DC
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2016 to 2022.
Electric oil pump, current IQ IONIQEV_EOP_CURRENT_IQ
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2016 to 2022.
Electric vehicle supply equipment, target current IONIQEV_HVBAT_TARGET_CURR
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Electric water pump, actual rotation speed IONIQEV_EWP_ACTUAL_ROTATION_SPEED
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2016 to 2022.
Electric water pump, commanded rotation speed IONIQEV_EWP_COMMANDED_ROTATION_SPEED
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 24)- Range
- 0 to 6120 rpm
- Unit
- rpm
In testing for 2016 to 2022.
Electric water pump, current DC IONIQEV_EWP_CURRENT_DC
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 A
- Unit
- A
In testing for 2016 to 2022.
Electric water pump, voltage DC IONIQEV_EWP_VOLTAGE_DC
- Request
22 E0 09 - Service 22
DID E009 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2022.
High voltage battery, max current IONIQEV_HVBAT_EV_MAX_CURRENT
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
High voltage battery, max voltage IONIQEV_HVBAT_EV_MAX_VOLTAGE
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
High voltage battery, state of charge IONIQEV_HVBAT_SOC_VCMS
Pelican can show this parameter as the state of charge.
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
High voltage battery, target current IONIQEV_HVBAT_BMS_TARGET_CURRENT
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
High voltage battery, target voltage IONIQEV_HVBAT_BMS_TARGET_VOLTAGE
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
High voltage battery, target voltage IONIQEV_HVBAT_TARGET_VOLT
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
High voltage battery, voltage IONIQEV_HVBAT_HV_BATTERY_VOLTAGE
Pelican can show this parameter as the traction battery voltage.
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery charge IONIQEV_HVBAT_SOC
Pelican can show this parameter as the state of charge.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery charge IONIQEV_HVBAT_SOC_DISP_7E4
Pelican can show this parameter as the state of charge.
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery charge, displayed IONIQPHEV_HVBAT_SOC_DISPConfirmed
Pelican can show this parameter as the state of charge.
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 248 to 255 of the reply, 8 bits.
0x6F = 111 → (111 ÷ 2) = 55.5 %
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
HV battery charging IONIQEV_HVBAT_CHARGING
Pelican can show this parameter as the charging state.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bit 72 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery current IONIQEV_HVBAT_CURR
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery fan IONIQEV_HVBAT_FAN
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 Hz
- Unit
- Hz
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery fan status IONIQEV_HVBAT_FAN_STATUS
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery health IONIQPHEV_HVBAT_SOHConfirmed
Pelican can show this parameter as the state of health.
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 200 to 215 of the reply, 16 bits.
0x03A6 = 934 → (934 ÷ 10) = 93.4 %
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
HV battery heater 1 temperature IONIQEV_HVBAT_HTR1_T_2
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery heater 2 temperature IONIQEV_HVBAT_HTR2_T_2
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery max deterioration cell id IONIQEV_HVBAT_DET_MAX_ID
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
val- Range
- 0 to 98
- Unit
- Number
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery min deterioration IONIQEV_HVBAT_DET_MIN_2
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery min deterioration cell id IONIQEV_HVBAT_DET_MIN_ID
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
val- Range
- 0 to 98
- Unit
- Number
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery state of health IONIQEV_HVBAT_SOH_7E4
Pelican can show this parameter as the state of health.
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery temperature, maximum IONIQEV_HVBAT_T_MAX
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery temperature, minimum IONIQEV_HVBAT_T_MIN
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery temperature, module 1 IONIQEV_HVBAT_MOD1_T
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery temperature, module 2 IONIQEV_HVBAT_MOD2_T
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery temperature, module 3 IONIQEV_HVBAT_MOD3_T
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery temperature, module 4 IONIQEV_HVBAT_MOD4_T
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -127 to 127 °C
- Unit
- °C
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery voltage, DC IONIQEV_HVBAT_VDC
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV cell deviation, voltage IONIQEV_HVBAT_C_DEV_V_2
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Ignition IONIQEV_IGN
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bit 405 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Inverter capacitor voltage IONIQEV_INVERTER_CAPACITOR_V
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2016 to 2022.
Inverter capacitor voltage IONIQEV_INVRT_CV
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Isolation resistance IONIQEV_ISO_R
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 456 to 471 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 kΩ
- Unit
- kΩ
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Least deteriorated cell number IONIQEV_HVBAT_DET_MIN_CELLConfirmed
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 240 to 247 of the reply, 8 bits.
0x0A = 10 → 10
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Low-voltage dc-dc converter, input voltage IONIQEV_2025_LDC_INPUT_VOLTAGE
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016 to 2022.
Low-voltage dc-dc converter, input voltage IONIQEV_LDC_INPUT_VOLTAGE
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016 to 2022.
Low-voltage dc-dc converter, output current IONIQEV_2025_LDC_OUTPUT_CURRENT
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 10 ÷ 1000)- Range
- 0 to 655.35 A
- Unit
- A
In testing for 2016 to 2022.
Low-voltage dc-dc converter, output current IONIQEV_LDC_OUTPUT_CURRENT
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 10 ÷ 1000)- Range
- 0 to 655.35 A
- Unit
- A
In testing for 2016 to 2022.
Low-voltage dc-dc converter, output voltage IONIQEV_2025_LDC_OUTPUT_VOLTAGE
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2022.
Low-voltage dc-dc converter, output voltage IONIQEV_LDC_OUTPUT_VOLTAGE
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016 to 2022.
Low-voltage dc-dc converter, temperature IONIQEV_2025_LDC_T
- Request
22 E1 01 - Service 22
DID E101 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2016 to 2022.
Low-voltage dc-dc converter, temperature IONIQEV_LDC_T
- Request
22 E0 11 - Service 22
DID E011 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2016 to 2022.
Maximum cell voltage IONIQEV_C_V_MAX
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Maximum cell voltage IONIQEV_MAX_CELL_V
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016 to 2022.
Maximum cell voltage id IONIQEV_C_V_MAX_ID
The id of the cell with the highest voltage.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Maximum cell voltage no. IONIQEV_MAX_CELL_V_NO
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2022.
Minimum cell deterioration IONIQEV_HVBAT_DET_MINConfirmed
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 224 to 239 of the reply, 16 bits.
0x03E8 = 1000 → (1000 ÷ 10) = 100 %
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 %
- Unit
- %
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Minimum cell voltage IONIQEV_C_V_MIN
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Minimum cell voltage IONIQEV_MIN_CELL_V
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016 to 2022.
Minimum cell voltage id IONIQEV_C_V_MIN_ID
The id of the cell with the lowest voltage.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Minimum cell voltage no. IONIQEV_MIN_CELL_V_NO
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2022.
Most deteriorated cell number IONIQEV_HVBAT_DET_MAX_CELLConfirmed
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 216 to 223 of the reply, 8 bits.
0x5A = 90 → 90
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Normal charge port IONIQEV_NORMAL_CHG_PORT
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bit 74 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Normal charge port state IONIQEV_HVBAT_PLUG_NORM
Pelican can show this parameter as the plug state.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bit 74 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Normal charging energy, total IONIQEV_NORMAL_CHARGING_ENERGY_TOT
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 127 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 kWh
- Unit
- kWh
In testing for 2016 to 2022.
Normal charging, count IONIQEV_NORMAL_CHARGING_COUNT
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2016 to 2022.
On-board charger charger AC input current, RMS IONIQEV_ON_BOARD_CHARGER
- Request
21 01 - Service 21
PID 01 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val × 64 ÷ 25)- Range
- 0 to 652 A
- Unit
- A
In testing for 2016 to 2022.
On-board charger charger AC input voltage, instant IONIQEV_ON_BOARD_CHARGER_CHARGER_V
- Request
21 01 - Service 21
PID 01 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
(val × 64 ÷ 25 − 100)- Range
- -100 to 552 V
- Unit
- V
In testing for 2016 to 2022.
On-board charger charger AC input voltage, RMS IONIQEV_ON_BOARD_CHARGER_V
- Request
21 01 - Service 21
PID 01 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 64 ÷ 25)- Range
- 0 to 652 V
- Unit
- V
In testing for 2016 to 2022.
On-board charger charger temperature a IONIQEV_ON_BOARD_CHARGER_T
- Request
21 01 - Service 21
PID 01 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2016 to 2022.
On-board charger charger temperature b IONIQEV_ON_BOARD_CHARGER_T_B
- Request
21 01 - Service 21
PID 01 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 336 to 343 of the reply, 8 bits.
- Formula
(val − 100)- Range
- -100 to 155 °C
- Unit
- °C
In testing for 2016 to 2022.
Proximity detection voltage IONIQEV_HVBAT_PD_VOLTAGE
- Request
22 E0 03 - Service 22
DID E003 - Module
744 → 74C - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val × 10 ÷ 10000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Quick charging energy, total IONIQEV_QUICK_CHARGING_ENERGY_TOT
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 159 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 kWh
- Unit
- kWh
In testing for 2016 to 2022.
Quick charging, count IONIQEV_QUICK_CHARGING_COUNT
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 95 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2016 to 2022.
Rapid charge port IONIQEV_RAPID_CHG_PORT
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bit 73 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Rapid charge port state IONIQEV_HVBAT_PLUG_RAPD
Pelican can show this parameter as the plug state.
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bit 73 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Relative accelerator pedal position voltage IONIQEV_RELATIVE_ACCELERATOR_PEDAL_POSITION_VOLTAGE
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 112 to 127 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 5)- Range
- -6553.6 to 6553.4 V
- Unit
- V
In testing for 2016 to 2022.
Response error from battery sensor flag, battery sensor IONIQEV_RESPONSE_ERROR
- Request
22 ED 27 - Service 22
DID ED27 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 178 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
State of charge BMS IONIQEV_ST_CHG_BMS
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 %
- Unit
- %
In testing for 2016 to 2022.
Supply voltage IONIQEV_SUPPLY_VOLTAGE
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2022.
System voltage IONIQEV_SYSTEM_VOLTAGE
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
In testing for 2016 to 2022.
Throttle position sensor voltage #1 IONIQEV_THROTTLE_POSITION_SENSOR_VOLTAGE__1
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0012207031)- Range
- 0 to 79 V
- Unit
- V
In testing for 2016 to 2022.
Throttle position sensor voltage #2 IONIQEV_THROTTLE_POSITION_SENSOR_VOLTAGE__2
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0012207031)- Range
- 0 to 79 V
- Unit
- V
In testing for 2016 to 2022.
Total charge, current IONIQEV_HVBAT_CHRG_TOT_C
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 271 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Total charge, energy IONIQEV_HVBAT_CHRG_TOT_E
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 304 to 335 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 kWh
- Unit
- kWh
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Total discharge, current IONIQEV_HVBAT_DSCH_TOT_C
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 303 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 Ah
- Unit
- Ah
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Total discharge, energy IONIQEV_HVBAT_DSCH_TOT_E
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 336 to 367 of the reply, 32 bits.
- Formula
(val ÷ 10)- Range
- 0 to 429496729 kWh
- Unit
- kWh
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Wastegate position voltage IONIQEV_WASTEGATE_POS_V
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- -5.01 to 5.01 V
- Unit
- V
In testing for 2016 to 2022.
Battery › Charging
400V relay on/off request IONIQEV_400V_RELAY_ON_OFF_REQUEST
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing
Bit 43 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
400V relay status IONIQEV_400V_RELAY_STATUS
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing
Bit 42 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
AC charging state IONIQEV_AC_CHRG_STATE
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bit 141 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
AC inlet temperature 1 IONIQEV_AC_INLET_T_1
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2016 to 2022.
Auxiliary battery voltage IONIQEV_AUX_BATTERY_VOLTAGE
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery main relay status IONIQEV_BATTERY_MAIN_RELAY_STATUS
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing
Bit 37 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
Charging socket connected IONIQEV_CHARGING_SOCKET_CONNECTED
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing
Bit 38 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2022.
DC charging state IONIQEV_DC_CHRG_STATE
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bit 140 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
DC inlet temperature 1 IONIQEV_DC_INLET_T_1
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2016 to 2022.
DC inlet temperature 2 IONIQEV_DC_INLET_T_2
- Request
22 E0 04 - Service 22
DID E004 - Module
744 → 74C - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2016 to 2022.
Electric vehicle supply equipment, current IONIQEV_EVSE_C
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2016 to 2022.
Electric vehicle supply equipment, current, max IONIQEV_EVSE_MAXIMUM_CURRENT_VALUE
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2016 to 2022.
Electric vehicle supply equipment, current, min IONIQEV_EVSE_MINIMUM_CURRENT_VALUE
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2016 to 2022.
Electric vehicle supply equipment, power, delivered IONIQEV_EVSE_DELIVERED_POWER_VALUE
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
(val × 10 ÷ 1000)- Range
- 0 to 655.35 kWh
- Unit
- kWh
In testing for 2016 to 2022.
Electric vehicle supply equipment, power, main IONIQEV_EVSE_MAIN_POWER
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kW
- Unit
- kW
In testing for 2016 to 2022.
Electric vehicle supply equipment, power, max IONIQEV_EVSE_MAXIMUM_POWER_VALUE
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 W
- Unit
- W
In testing for 2016 to 2022.
Electric vehicle supply equipment, regulation tolerance IONIQEV_EVSE_CURRENT_REGULATION_TOLERANCE_VALUE
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 A
- Unit
- A
In testing for 2016 to 2022.
Electric vehicle supply equipment, voltage IONIQEV_EVSE_V
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 136 to 151 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016 to 2022.
Electric vehicle supply equipment, voltage, max IONIQEV_EVSE_MAXIMUM_VOLTAGE_VALUE
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016 to 2022.
Electric vehicle supply equipment, voltage, min IONIQEV_EVSE_MINIMUM_VOLTAGE_VALUE
- Request
22 E0 02 - Service 22
DID E002 - Module
744 → 74C - Every
250 ms - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016 to 2022.
Estimated charging power IONIQEV_ESTIMATED_CHRG_POWER
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 10 − 50)- Range
- -50 to 655300 W
- Unit
- W
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
On-board charger, AC current a IONIQEV_OBC_AC_CURRENT_A_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2016 to 2022.
On-board charger, AC current b IONIQEV_OBC_AC_CURRENT_B_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2016 to 2022.
On-board charger, AC frequency IONIQEV_OBC_AC_FREQUENCY
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 Hz
- Unit
- Hz
In testing for 2016 to 2022.
On-board charger, AC input current sensor a signal voltage IONIQEV_OBC_AC_INPUT_CURRENT_SENSOR_A_SIGNAL_VOLTAGE
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
In testing for 2016 to 2022.
On-board charger, AC input current sensor b signal voltage IONIQEV_OBC_AC_INPUT_CURRENT_SENSOR_B_SIGNAL_VOLTAGE
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
In testing for 2016 to 2022.
On-board charger, AC total current IONIQEV_OBC_AC_TOTAL_CURRENT_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2016 to 2022.
On-board charger, AC voltage a IONIQEV_OBC_AC_VOLTAGE_A_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016 to 2022.
On-board charger, AC voltage b IONIQEV_OBC_AC_VOLTAGE_B_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016 to 2022.
On-board charger, charge mode DC target current IONIQEV_OBC_CHARGE_MODE_DC_TARGET_CURRENT
- Request
22 E0 03 - Service 22
DID E003 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2016 to 2022.
On-board charger, charge mode DC target voltage IONIQEV_OBC_CHARGE_MODE_DC_TARGET_VOLTAGE
- Request
22 E0 03 - Service 22
DID E003 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016 to 2022.
On-board charger, charging AC current IONIQEV_OBC_CHRG_AC_CURRENT
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
On-board charger, charging AC voltage IONIQEV_OBC_CHRG_AC_VOLTAGE
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
On-board charger, charging DC current IONIQEV_OBC_CHRG_DC_CURRENT
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
On-board charger, charging DC voltage IONIQEV_OBC_CHRG_DC_VOLTAGE
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
On-board charger, DC current a IONIQEV_OBC_DC_CURRENT_A_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2016 to 2022.
On-board charger, DC current b IONIQEV_OBC_DC_CURRENT_B_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2016 to 2022.
On-board charger, DC current total IONIQEV_OBC_DC_CURRENT_TOTAL_RMS
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2016 to 2022.
On-board charger, DC voltage IONIQEV_OBC_DC_VOLTAGE
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
In testing for 2016 to 2022.
On-board charger, discharging AC current IONIQEV_OBC_DCHRG_AC_CURRENT
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
On-board charger, discharging DC current IONIQEV_OBC_DCHRG_DC_CURRENT
- Request
22 E0 01 - Service 22
DID E001 - Module
744 → 74C - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 A
- Unit
- A
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
On-board charger, temperature a IONIQEV_OBC_T_A
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2022.
On-board charger, temperature b IONIQEV_OBC_T_B
- Request
22 E0 02 - Service 22
DID E002 - Module
7E5 → 7ED - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2022.
Battery › Modules › 001
HV battery module 001 voltage IONIQEV_HVBAT_CMU001_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 001 voltage IONIQPHEV_HVBAT_CMU001_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 32 to 39 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 002
HV battery module 002 voltage IONIQEV_HVBAT_CMU002_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 002 voltage IONIQPHEV_HVBAT_CMU002_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 40 to 47 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 003
HV battery module 003 voltage IONIQEV_HVBAT_CMU003_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 003 voltage IONIQPHEV_HVBAT_CMU003_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 48 to 55 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 004
HV battery module 004 voltage IONIQEV_HVBAT_CMU004_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 004 voltage IONIQPHEV_HVBAT_CMU004_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 56 to 63 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 005
HV battery module 005 voltage IONIQEV_HVBAT_CMU005_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 005 voltage IONIQPHEV_HVBAT_CMU005_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 64 to 71 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 006
HV battery module 006 voltage IONIQEV_HVBAT_CMU006_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 006 voltage IONIQPHEV_HVBAT_CMU006_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 72 to 79 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 007
HV battery module 007 voltage IONIQEV_HVBAT_CMU007_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 007 voltage IONIQPHEV_HVBAT_CMU007_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 80 to 87 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 008
HV battery module 008 voltage IONIQEV_HVBAT_CMU008_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 008 voltage IONIQPHEV_HVBAT_CMU008_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 88 to 95 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 009
HV battery module 009 voltage IONIQEV_HVBAT_CMU009_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 009 voltage IONIQPHEV_HVBAT_CMU009_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 96 to 103 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 010
HV battery module 010 voltage IONIQEV_HVBAT_CMU010_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 010 voltage IONIQPHEV_HVBAT_CMU010_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 104 to 111 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 011
HV battery module 011 voltage IONIQEV_HVBAT_CMU011_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 011 voltage IONIQPHEV_HVBAT_CMU011_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 112 to 119 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 012
HV battery module 012 voltage IONIQEV_HVBAT_CMU012_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 012 voltage IONIQPHEV_HVBAT_CMU012_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 120 to 127 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 013
HV battery module 013 voltage IONIQEV_HVBAT_CMU013_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 013 voltage IONIQPHEV_HVBAT_CMU013_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 128 to 135 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 014
HV battery module 014 voltage IONIQEV_HVBAT_CMU014_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 014 voltage IONIQPHEV_HVBAT_CMU014_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 136 to 143 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 015
HV battery module 015 voltage IONIQEV_HVBAT_CMU015_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 015 voltage IONIQPHEV_HVBAT_CMU015_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 144 to 151 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 016
HV battery module 016 voltage IONIQEV_HVBAT_CMU016_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 016 voltage IONIQPHEV_HVBAT_CMU016_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 152 to 159 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 017
HV battery module 017 voltage IONIQEV_HVBAT_CMU017_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 017 voltage IONIQPHEV_HVBAT_CMU017_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 160 to 167 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 018
HV battery module 018 voltage IONIQEV_HVBAT_CMU018_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 018 voltage IONIQPHEV_HVBAT_CMU018_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 168 to 175 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 019
HV battery module 019 voltage IONIQEV_HVBAT_CMU019_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 019 voltage IONIQPHEV_HVBAT_CMU019_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 176 to 183 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 020
HV battery module 020 voltage IONIQEV_HVBAT_CMU020_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 020 voltage IONIQPHEV_HVBAT_CMU020_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 184 to 191 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 021
HV battery module 021 voltage IONIQEV_HVBAT_CMU021_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 021 voltage IONIQPHEV_HVBAT_CMU021_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 192 to 199 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 022
HV battery module 022 voltage IONIQEV_HVBAT_CMU022_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 022 voltage IONIQPHEV_HVBAT_CMU022_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 200 to 207 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 023
HV battery module 023 voltage IONIQEV_HVBAT_CMU023_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 023 voltage IONIQPHEV_HVBAT_CMU023_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 208 to 215 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 024
HV battery module 024 voltage IONIQEV_HVBAT_CMU024_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 024 voltage IONIQPHEV_HVBAT_CMU024_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 216 to 223 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 025
HV battery module 025 voltage IONIQEV_HVBAT_CMU025_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 025 voltage IONIQPHEV_HVBAT_CMU025_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 224 to 231 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 026
HV battery module 026 voltage IONIQEV_HVBAT_CMU026_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 026 voltage IONIQPHEV_HVBAT_CMU026_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 232 to 239 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 027
HV battery module 027 voltage IONIQEV_HVBAT_CMU027_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 027 voltage IONIQPHEV_HVBAT_CMU027_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 240 to 247 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 028
HV battery module 028 voltage IONIQEV_HVBAT_CMU028_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 028 voltage IONIQPHEV_HVBAT_CMU028_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 248 to 255 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 029
HV battery module 029 voltage IONIQEV_HVBAT_CMU029_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 029 voltage IONIQPHEV_HVBAT_CMU029_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 256 to 263 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 030
HV battery module 030 voltage IONIQEV_HVBAT_CMU030_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 030 voltage IONIQPHEV_HVBAT_CMU030_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 264 to 271 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 031
HV battery module 031 voltage IONIQEV_HVBAT_CMU031_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 031 voltage IONIQPHEV_HVBAT_CMU031_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 272 to 279 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 032
HV battery module 032 voltage IONIQEV_HVBAT_CMU032_VOLT_7E4
- Request
22 01 02 - Service 22
DID 0102 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 032 voltage IONIQPHEV_HVBAT_CMU032_VOLTConfirmed
- Request
21 02 - Service 21
PID 02 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 280 to 287 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 033
HV battery module 033 voltage IONIQEV_HVBAT_CMU033_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 033 voltage IONIQPHEV_HVBAT_CMU033_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 32 to 39 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 034
HV battery module 034 voltage IONIQEV_HVBAT_CMU034_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 034 voltage IONIQPHEV_HVBAT_CMU034_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 40 to 47 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 035
HV battery module 035 voltage IONIQEV_HVBAT_CMU035_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 035 voltage IONIQPHEV_HVBAT_CMU035_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 48 to 55 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 036
HV battery module 036 voltage IONIQEV_HVBAT_CMU036_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 036 voltage IONIQPHEV_HVBAT_CMU036_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 56 to 63 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 037
HV battery module 037 voltage IONIQEV_HVBAT_CMU037_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 037 voltage IONIQPHEV_HVBAT_CMU037_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 64 to 71 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 038
HV battery module 038 voltage IONIQEV_HVBAT_CMU038_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 038 voltage IONIQPHEV_HVBAT_CMU038_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 72 to 79 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 039
HV battery module 039 voltage IONIQEV_HVBAT_CMU039_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 039 voltage IONIQPHEV_HVBAT_CMU039_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 80 to 87 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 040
HV battery module 040 voltage IONIQEV_HVBAT_CMU040_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 040 voltage IONIQPHEV_HVBAT_CMU040_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 88 to 95 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 041
HV battery module 041 voltage IONIQEV_HVBAT_CMU041_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 041 voltage IONIQPHEV_HVBAT_CMU041_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 96 to 103 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 042
HV battery module 042 voltage IONIQEV_HVBAT_CMU042_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 042 voltage IONIQPHEV_HVBAT_CMU042_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 104 to 111 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 043
HV battery module 043 voltage IONIQEV_HVBAT_CMU043_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 043 voltage IONIQPHEV_HVBAT_CMU043_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 112 to 119 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 044
HV battery module 044 voltage IONIQEV_HVBAT_CMU044_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 044 voltage IONIQPHEV_HVBAT_CMU044_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 120 to 127 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 045
HV battery module 045 voltage IONIQEV_HVBAT_CMU045_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 045 voltage IONIQPHEV_HVBAT_CMU045_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 128 to 135 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 046
HV battery module 046 voltage IONIQEV_HVBAT_CMU046_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 046 voltage IONIQPHEV_HVBAT_CMU046_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 136 to 143 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 047
HV battery module 047 voltage IONIQEV_HVBAT_CMU047_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 047 voltage IONIQPHEV_HVBAT_CMU047_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 144 to 151 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 048
HV battery module 048 voltage IONIQEV_HVBAT_CMU048_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 048 voltage IONIQPHEV_HVBAT_CMU048_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 152 to 159 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 049
HV battery module 049 voltage IONIQEV_HVBAT_CMU049_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 049 voltage IONIQPHEV_HVBAT_CMU049_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 160 to 167 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 050
HV battery module 050 voltage IONIQEV_HVBAT_CMU050_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 050 voltage IONIQPHEV_HVBAT_CMU050_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 168 to 175 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 051
HV battery module 051 voltage IONIQEV_HVBAT_CMU051_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 051 voltage IONIQPHEV_HVBAT_CMU051_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 176 to 183 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 052
HV battery module 052 voltage IONIQEV_HVBAT_CMU052_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 052 voltage IONIQPHEV_HVBAT_CMU052_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 184 to 191 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 053
HV battery module 053 voltage IONIQEV_HVBAT_CMU053_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 053 voltage IONIQPHEV_HVBAT_CMU053_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 192 to 199 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 054
HV battery module 054 voltage IONIQEV_HVBAT_CMU054_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 054 voltage IONIQPHEV_HVBAT_CMU054_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 200 to 207 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 055
HV battery module 055 voltage IONIQEV_HVBAT_CMU055_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 055 voltage IONIQPHEV_HVBAT_CMU055_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 208 to 215 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 056
HV battery module 056 voltage IONIQEV_HVBAT_CMU056_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 056 voltage IONIQPHEV_HVBAT_CMU056_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 216 to 223 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 057
HV battery module 057 voltage IONIQEV_HVBAT_CMU057_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 057 voltage IONIQPHEV_HVBAT_CMU057_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 224 to 231 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 058
HV battery module 058 voltage IONIQEV_HVBAT_CMU058_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 058 voltage IONIQPHEV_HVBAT_CMU058_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 232 to 239 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 059
HV battery module 059 voltage IONIQEV_HVBAT_CMU059_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 059 voltage IONIQPHEV_HVBAT_CMU059_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 240 to 247 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 060
HV battery module 060 voltage IONIQEV_HVBAT_CMU060_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 060 voltage IONIQPHEV_HVBAT_CMU060_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 248 to 255 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 061
HV battery module 061 voltage IONIQEV_HVBAT_CMU061_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 061 voltage IONIQPHEV_HVBAT_CMU061_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 256 to 263 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 062
HV battery module 062 voltage IONIQEV_HVBAT_CMU062_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 062 voltage IONIQPHEV_HVBAT_CMU062_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 264 to 271 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 063
HV battery module 063 voltage IONIQEV_HVBAT_CMU063_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 063 voltage IONIQPHEV_HVBAT_CMU063_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 272 to 279 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 064
HV battery module 064 voltage IONIQEV_HVBAT_CMU064_VOLT_7E4
- Request
22 01 03 - Service 22
DID 0103 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 064 voltage IONIQPHEV_HVBAT_CMU064_VOLTConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 280 to 287 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 065
HV battery module 065 voltage IONIQEV_HVBAT_CMU065_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 065 voltage IONIQPHEV_HVBAT_CMU065_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 32 to 39 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 066
HV battery module 066 voltage IONIQEV_HVBAT_CMU066_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 066 voltage IONIQPHEV_HVBAT_CMU066_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 40 to 47 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 067
HV battery module 067 voltage IONIQEV_HVBAT_CMU067_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 067 voltage IONIQPHEV_HVBAT_CMU067_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 48 to 55 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 068
HV battery module 068 voltage IONIQEV_HVBAT_CMU068_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 068 voltage IONIQPHEV_HVBAT_CMU068_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 56 to 63 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 069
HV battery module 069 voltage IONIQEV_HVBAT_CMU069_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 069 voltage IONIQPHEV_HVBAT_CMU069_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 64 to 71 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 070
HV battery module 070 voltage IONIQEV_HVBAT_CMU070_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 070 voltage IONIQPHEV_HVBAT_CMU070_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 72 to 79 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 071
HV battery module 071 voltage IONIQEV_HVBAT_CMU071_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 071 voltage IONIQPHEV_HVBAT_CMU071_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 80 to 87 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 072
HV battery module 072 voltage IONIQEV_HVBAT_CMU072_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 072 voltage IONIQPHEV_HVBAT_CMU072_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 88 to 95 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 073
HV battery module 073 voltage IONIQEV_HVBAT_CMU073_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 073 voltage IONIQPHEV_HVBAT_CMU073_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 96 to 103 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 074
HV battery module 074 voltage IONIQEV_HVBAT_CMU074_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 074 voltage IONIQPHEV_HVBAT_CMU074_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 104 to 111 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 075
HV battery module 075 voltage IONIQEV_HVBAT_CMU075_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 075 voltage IONIQPHEV_HVBAT_CMU075_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 112 to 119 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 076
HV battery module 076 voltage IONIQEV_HVBAT_CMU076_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 076 voltage IONIQPHEV_HVBAT_CMU076_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 120 to 127 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 077
HV battery module 077 voltage IONIQEV_HVBAT_CMU077_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 077 voltage IONIQPHEV_HVBAT_CMU077_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 128 to 135 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 078
HV battery module 078 voltage IONIQEV_HVBAT_CMU078_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 078 voltage IONIQPHEV_HVBAT_CMU078_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 136 to 143 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 079
HV battery module 079 voltage IONIQEV_HVBAT_CMU079_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 079 voltage IONIQPHEV_HVBAT_CMU079_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 144 to 151 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 080
HV battery module 080 voltage IONIQEV_HVBAT_CMU080_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 080 voltage IONIQPHEV_HVBAT_CMU080_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 152 to 159 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 081
HV battery module 081 voltage IONIQEV_HVBAT_CMU081_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 081 voltage IONIQPHEV_HVBAT_CMU081_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 160 to 167 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 082
HV battery module 082 voltage IONIQEV_HVBAT_CMU082_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 082 voltage IONIQPHEV_HVBAT_CMU082_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 168 to 175 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 083
HV battery module 083 voltage IONIQEV_HVBAT_CMU083_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 083 voltage IONIQPHEV_HVBAT_CMU083_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 176 to 183 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 084
HV battery module 084 voltage IONIQEV_HVBAT_CMU084_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 084 voltage IONIQPHEV_HVBAT_CMU084_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 184 to 191 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 085
HV battery module 085 voltage IONIQEV_HVBAT_CMU085_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 085 voltage IONIQPHEV_HVBAT_CMU085_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 192 to 199 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 086
HV battery module 086 voltage IONIQEV_HVBAT_CMU086_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 086 voltage IONIQPHEV_HVBAT_CMU086_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 200 to 207 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 087
HV battery module 087 voltage IONIQEV_HVBAT_CMU087_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 087 voltage IONIQPHEV_HVBAT_CMU087_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 208 to 215 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 088
HV battery module 088 voltage IONIQEV_HVBAT_CMU088_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 088 voltage IONIQPHEV_HVBAT_CMU088_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 216 to 223 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 089
HV battery module 089 voltage IONIQEV_HVBAT_CMU089_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 089 voltage IONIQPHEV_HVBAT_CMU089_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 224 to 231 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 090
HV battery module 090 voltage IONIQEV_HVBAT_CMU090_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 090 voltage IONIQPHEV_HVBAT_CMU090_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 232 to 239 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 091
HV battery module 091 voltage IONIQEV_HVBAT_CMU091_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 091 voltage IONIQPHEV_HVBAT_CMU091_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 240 to 247 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 092
HV battery module 092 voltage IONIQEV_HVBAT_CMU092_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 092 voltage IONIQPHEV_HVBAT_CMU092_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 248 to 255 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 093
HV battery module 093 voltage IONIQEV_HVBAT_CMU093_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 093 voltage IONIQPHEV_HVBAT_CMU093_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 256 to 263 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 094
HV battery module 094 voltage IONIQEV_HVBAT_CMU094_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 094 voltage IONIQPHEV_HVBAT_CMU094_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 264 to 271 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 095
HV battery module 095 voltage IONIQEV_HVBAT_CMU095_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 095 voltage IONIQPHEV_HVBAT_CMU095_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 272 to 279 of the reply, 8 bits.
0xB8 = 184 → (184 ÷ 50) = 3.68 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 096
HV battery module 096 voltage IONIQEV_HVBAT_CMU096_VOLT_7E4
- Request
22 01 04 - Service 22
DID 0104 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 096 voltage IONIQPHEV_HVBAT_CMU096_VOLTConfirmed
- Request
21 04 - Service 21
PID 04 - Module
7E4 → 7EC - Every
1 s - Testing for 2016, 2020 to 2022
Example reply from a 2019 Hyundai Ioniq Electric.
Bits 280 to 287 of the reply, 8 bits.
0xB7 = 183 → (183 ÷ 50) = 3.66 V
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
Confirmed for 2017 to 2019. In testing for 2016, 2022. Not supported for 2020 to 2021.
Battery › Modules › 097
HV battery module 097 voltage IONIQEV_HVBAT_CMU097_VOLT
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 097 voltage IONIQEV_HVBAT_CMU097_VOLT_7E4
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 098
HV battery module 098 voltage IONIQEV_HVBAT_CMU098_VOLT
- Request
22 01 05 - Service 22
DID 0105 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 2.8 to 4.2 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
HV battery module 098 voltage IONIQEV_HVBAT_CMU098_VOLT_7E4
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 099
HV battery module 099 voltage IONIQEV_HVBAT_CMU099_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 100
HV battery module 100 voltage IONIQEV_HVBAT_CMU100_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 101
HV battery module 101 voltage IONIQEV_HVBAT_CMU101_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 102
HV battery module 102 voltage IONIQEV_HVBAT_CMU102_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 103
HV battery module 103 voltage IONIQEV_HVBAT_CMU103_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 104
HV battery module 104 voltage IONIQEV_HVBAT_CMU104_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 105
HV battery module 105 voltage IONIQEV_HVBAT_CMU105_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 106
HV battery module 106 voltage IONIQEV_HVBAT_CMU106_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 107
HV battery module 107 voltage IONIQEV_HVBAT_CMU107_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 108
HV battery module 108 voltage IONIQEV_HVBAT_CMU108_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 109
HV battery module 109 voltage IONIQEV_HVBAT_CMU109_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 110
HV battery module 110 voltage IONIQEV_HVBAT_CMU110_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 111
HV battery module 111 voltage IONIQEV_HVBAT_CMU111_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 112
HV battery module 112 voltage IONIQEV_HVBAT_CMU112_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 113
HV battery module 113 voltage IONIQEV_HVBAT_CMU113_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 114
HV battery module 114 voltage IONIQEV_HVBAT_CMU114_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 115
HV battery module 115 voltage IONIQEV_HVBAT_CMU115_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 116
HV battery module 116 voltage IONIQEV_HVBAT_CMU116_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 117
HV battery module 117 voltage IONIQEV_HVBAT_CMU117_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 118
HV battery module 118 voltage IONIQEV_HVBAT_CMU118_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 119
HV battery module 119 voltage IONIQEV_HVBAT_CMU119_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 120
HV battery module 120 voltage IONIQEV_HVBAT_CMU120_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 121
HV battery module 121 voltage IONIQEV_HVBAT_CMU121_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 122
HV battery module 122 voltage IONIQEV_HVBAT_CMU122_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 123
HV battery module 123 voltage IONIQEV_HVBAT_CMU123_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 124
HV battery module 124 voltage IONIQEV_HVBAT_CMU124_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 125
HV battery module 125 voltage IONIQEV_HVBAT_CMU125_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 126
HV battery module 126 voltage IONIQEV_HVBAT_CMU126_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 127
HV battery module 127 voltage IONIQEV_HVBAT_CMU127_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 128
HV battery module 128 voltage IONIQEV_HVBAT_CMU128_VOLT
- Request
22 01 0A - Service 22
DID 010A - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 129
HV battery module 129 voltage IONIQEV_HVBAT_CMU129_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 130
HV battery module 130 voltage IONIQEV_HVBAT_CMU130_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 131
HV battery module 131 voltage IONIQEV_HVBAT_CMU131_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 132
HV battery module 132 voltage IONIQEV_HVBAT_CMU132_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 133
HV battery module 133 voltage IONIQEV_HVBAT_CMU133_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 134
HV battery module 134 voltage IONIQEV_HVBAT_CMU134_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 135
HV battery module 135 voltage IONIQEV_HVBAT_CMU135_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 136
HV battery module 136 voltage IONIQEV_HVBAT_CMU136_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 137
HV battery module 137 voltage IONIQEV_HVBAT_CMU137_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 138
HV battery module 138 voltage IONIQEV_HVBAT_CMU138_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 139
HV battery module 139 voltage IONIQEV_HVBAT_CMU139_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 140
HV battery module 140 voltage IONIQEV_HVBAT_CMU140_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 141
HV battery module 141 voltage IONIQEV_HVBAT_CMU141_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 142
HV battery module 142 voltage IONIQEV_HVBAT_CMU142_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 143
HV battery module 143 voltage IONIQEV_HVBAT_CMU143_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 144
HV battery module 144 voltage IONIQEV_HVBAT_CMU144_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 145
HV battery module 145 voltage IONIQEV_HVBAT_CMU145_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 146
HV battery module 146 voltage IONIQEV_HVBAT_CMU146_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 147
HV battery module 147 voltage IONIQEV_HVBAT_CMU147_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 148
HV battery module 148 voltage IONIQEV_HVBAT_CMU148_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 149
HV battery module 149 voltage IONIQEV_HVBAT_CMU149_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 150
HV battery module 150 voltage IONIQEV_HVBAT_CMU150_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 151
HV battery module 151 voltage IONIQEV_HVBAT_CMU151_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 152
HV battery module 152 voltage IONIQEV_HVBAT_CMU152_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 153
HV battery module 153 voltage IONIQEV_HVBAT_CMU153_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 154
HV battery module 154 voltage IONIQEV_HVBAT_CMU154_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 155
HV battery module 155 voltage IONIQEV_HVBAT_CMU155_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 156
HV battery module 156 voltage IONIQEV_HVBAT_CMU156_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 157
HV battery module 157 voltage IONIQEV_HVBAT_CMU157_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 158
HV battery module 158 voltage IONIQEV_HVBAT_CMU158_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 159
HV battery module 159 voltage IONIQEV_HVBAT_CMU159_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 160
HV battery module 160 voltage IONIQEV_HVBAT_CMU160_VOLT
- Request
22 01 0B - Service 22
DID 010B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 161
HV battery module 161 voltage IONIQEV_HVBAT_CMU161_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 162
HV battery module 162 voltage IONIQEV_HVBAT_CMU162_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 163
HV battery module 163 voltage IONIQEV_HVBAT_CMU163_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 164
HV battery module 164 voltage IONIQEV_HVBAT_CMU164_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 165
HV battery module 165 voltage IONIQEV_HVBAT_CMU165_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 166
HV battery module 166 voltage IONIQEV_HVBAT_CMU166_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 167
HV battery module 167 voltage IONIQEV_HVBAT_CMU167_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 168
HV battery module 168 voltage IONIQEV_HVBAT_CMU168_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 169
HV battery module 169 voltage IONIQEV_HVBAT_CMU169_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 170
HV battery module 170 voltage IONIQEV_HVBAT_CMU170_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 171
HV battery module 171 voltage IONIQEV_HVBAT_CMU171_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 172
HV battery module 172 voltage IONIQEV_HVBAT_CMU172_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 173
HV battery module 173 voltage IONIQEV_HVBAT_CMU173_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 174
HV battery module 174 voltage IONIQEV_HVBAT_CMU174_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 175
HV battery module 175 voltage IONIQEV_HVBAT_CMU175_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 176
HV battery module 176 voltage IONIQEV_HVBAT_CMU176_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 177
HV battery module 177 voltage IONIQEV_HVBAT_CMU177_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 178
HV battery module 178 voltage IONIQEV_HVBAT_CMU178_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 179
HV battery module 179 voltage IONIQEV_HVBAT_CMU179_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 180
HV battery module 180 voltage IONIQEV_HVBAT_CMU180_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 181
HV battery module 181 voltage IONIQEV_HVBAT_CMU181_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 182
HV battery module 182 voltage IONIQEV_HVBAT_CMU182_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 183
HV battery module 183 voltage IONIQEV_HVBAT_CMU183_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 184
HV battery module 184 voltage IONIQEV_HVBAT_CMU184_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 185
HV battery module 185 voltage IONIQEV_HVBAT_CMU185_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 186
HV battery module 186 voltage IONIQEV_HVBAT_CMU186_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 232 to 239 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 187
HV battery module 187 voltage IONIQEV_HVBAT_CMU187_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 188
HV battery module 188 voltage IONIQEV_HVBAT_CMU188_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 189
HV battery module 189 voltage IONIQEV_HVBAT_CMU189_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 190
HV battery module 190 voltage IONIQEV_HVBAT_CMU190_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 191
HV battery module 191 voltage IONIQEV_HVBAT_CMU191_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.
Battery › Modules › 192
HV battery module 192 voltage IONIQEV_HVBAT_CMU192_VOLT
- Request
22 01 0C - Service 22
DID 010C - Module
7E4 → 7EC - Every
1 s - Testing
Bits 280 to 287 of the reply, 8 bits.
- Formula
(val ÷ 50)- Range
- 0 to 5.1 V
- Unit
- V
In testing for 2016, 2019 to 2022. Not supported for 2017 to 2018.