Engine parameters
The Hyundai i10 has 406 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
4WD calculated clutch power HYUNDAI_AWD_CALC_CLU_POWER
- Request
22 01 A3 - Service 22
DID 01A3 - Module
740 → 748 - Every
250 ms - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 39.062 ÷ 10000)- Range
- 0 to 255 kWh
- Unit
- kWh
In testing for 2007 to 2026.
4WD calculated engine power HYUNDAI_AWD_CALC_ENG_POWER
- Request
22 01 A3 - Service 22
DID 01A3 - Module
740 → 748 - Every
250 ms - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val × 9.766 ÷ 10000)- Range
- 0 to 64 kWh
- Unit
- kWh
In testing for 2007 to 2026.
4WD calculated, commanded torque HYUNDAI_AWD_CALC_CMD_TQ
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 40 to 55 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 8)- Range
- -4096 to 4095.875 N·m
- Unit
- N·m
In testing for 2007 to 2026.
4WD clutch duty HYUNDAI_AWD_CLU_DUTY
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 72 to 87 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 100 %
- Unit
- %
In testing for 2007 to 2026.
4WD clutch pressure HYUNDAI_AWD_CLU_P
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 216 to 231 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.001953)- Range
- -63.99 to 63.99 bar
- Unit
- bar
In testing for 2007 to 2026.
4WD clutch stress HYUNDAI_AWD_CLU_STRESS
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 104 to 119 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.001953)- Range
- -63.99 to 63.99 %
- Unit
- %
In testing for 2007 to 2026.
4WD clutch torque HYUNDAI_AWD_CLU_TQ
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 200 to 215 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.9375 N·m
- Unit
- N·m
In testing for 2007 to 2026.
4WD clutch, actual pressure HYUNDAI_AWD_CLU_ACT_P
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 144 to 159 of the reply, 16 bits. The value is signed.
- Formula
(val × 19.53 ÷ 10000)- Range
- -63.99 to 63.99 bar
- Unit
- bar
In testing for 2007 to 2026.
4WD clutch, actual torque HYUNDAI_AWD_CLU_ACT_TQ
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 128 to 143 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 8)- Range
- -4096 to 4095.875 N·m
- Unit
- N·m
In testing for 2007 to 2026.
4WD front axle ratio HYUNDAI_AWD_FRONT_AXLE_RAT
- Request
22 01 A3 - Service 22
DID 01A3 - Module
740 → 748 - Every
250 ms - Testing
Bits 56 to 71 of the reply, 16 bits. The value is signed.
- Formula
(val × 2 ÷ 65535)- Range
- -1 to 0.999
- Unit
- Number
In testing for 2007 to 2026.
4WD max clutch stress HYUNDAI_AWD_MAX_CLU_STRESS
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val × 19.531 ÷ 10000)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
4WD pump current HYUNDAI_AWD_PMP_CURRENT
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 112 to 127 of the reply, 16 bits. The value is signed.
- Formula
(val × 78.125 ÷ 10000)- Range
- -256 to 255 A
- Unit
- A
In testing for 2007 to 2026.
4WD pump PWM duty HYUNDAI_AWD_PMP_PWM_DUTY
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 56 to 71 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Absolute load value LOAD_ABSSAE J1979Confirmed
- Request
01 43 - Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2024. Supported for 2015 to 2018.
Accumulated normal charging energy HYUNDAI_ACCUMULATED_NORMAL
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 96 to 127 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 kWh
- Unit
- kWh
In testing for 2007 to 2026.
Adaptation value for lower stop of wastegate actuator HYUNDAI_ADPT_LO_STOP
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- -5.01 to 5.01 V
- Unit
- V
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Air conditioning pressure HYUNDAI_AC_P
- Request
22 E0 14 - Service 22
DID E014 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 13.79)- Range
- 0 to 3516.45 kPa
- Unit
- kPa
In testing for 2007 to 2026.
Air conditioning relay HYUNDAI_AC_RELAY
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 101 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2024.
Automatic transmission fluid temperature HYUNDAI_ATF_T
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 A0 - Service 21
PID A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Automatic transmission fluid temperature HYUNDAI_ATF_T_7E1
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2026.
AUX amps LDC HYUNDAI_AUX_AMPS_LDC
- Request
21 02 - Service 21
PID 02 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 A
- Unit
- A
In testing for 2007 to 2026.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2024. Supported for 2015 to 2018.
Barometric pressure HYUNDAI_BAROMETRIC_PRESSURE
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 319 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 kPa
- Unit
- kPa
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Battery management ignition HYUNDAI_BAT_MANAGEMENT_IGN
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bit 405 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Battery management main relay HYUNDAI_BAT_MANAGEMENT_MAIN
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bit 79 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Boost pressure HYUNDAI_BOOST_P
- Request
22 E0 F2 - Service 22
DID E0F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 496 to 511 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767
- Unit
- Raw value
In testing for 2007 to 2026.
Boost pressure HYUNDAI_BOOST_P_V2
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val × 1372549 ÷ 100000)- Range
- 0 to 3499.9999
- Unit
- Raw value
In testing for 2007 to 2026.
Boost pressure upstream HYUNDAI_BOOST_P_UP
- Request
22 E0 03 - Service 22
DID E003 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 39 ÷ 500)- Range
- 0 to 5111
- Unit
- Raw value
In testing for 2007 to 2026.
Boost pressure upstream, desired HYUNDAI_BOOST_P_UP_DES
- Request
22 E0 03 - Service 22
DID E003 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 39 ÷ 500)- Range
- 0 to 5111
- Unit
- Raw value
In testing for 2007 to 2026.
Boost regulator duty HYUNDAI_BOOST_REGULATOR_DUTY
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2015 to 2018.
Calculated oil temperature HYUNDAI_CALC_OIL_T
Pelican can show this parameter as the engine oil temperature.
- Request
22 E0 11 - Service 22
DID E011 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2026.
Calculated oil temperature HYUNDAI_CRUZ_CALC_OIL_T
- Request
22 E0 11 - Service 22
DID E011 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2026.
Camshaft exhaust position, actual HYUNDAI_CAM_EXH_POS_ACT
- Request
21 20 - Service 21
PID 20 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × -3 ÷ 8 − 40)- Range
- -135 to -40 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft exhaust position, commanded HYUNDAI_CAM_EXH_POS_CMD
- Request
21 20 - Service 21
PID 20 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × -3 ÷ 8 − 40)- Range
- -135 to -40 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft intake position, actual HYUNDAI_CAM_INT_POS_ACT
- Request
21 20 - Service 21
PID 20 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 + 60)- Range
- 0 to 155 °
- Unit
- °
In testing for 2007 to 2026.
Camshaft intake position, commanded HYUNDAI_CAM_INT_POS_CMD
- Request
21 20 - Service 21
PID 20 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val × 3 ÷ 8 + 60)- Range
- 0 to 155 °
- Unit
- °
In testing for 2007 to 2026.
Catalyst damaging misfires total all cylinders HYUNDAI_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERSConfirmed
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Catalyst damaging misfires total all cylinders HYUNDAI_CATDMG_MIS_TOT_ALL
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Catalyst damaging misfires total, cylinder 1 HYUNDAI_CATALYST_DAMAGING_MISFIRES_TOTAL_C1Confirmed
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Catalyst damaging misfires total, cylinder 1 HYUNDAI_CATDMG_MIS_TOT_1
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Catalyst damaging misfires total, cylinder 1 HYUNDAI_CATDMG_MIS_TOT_1_V2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Catalyst damaging misfires total, cylinder 2 HYUNDAI_CATALYST_DAMAGING_MISFIRES_TOTAL_C2Confirmed
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Catalyst damaging misfires total, cylinder 2 HYUNDAI_CATDMG_MIS_TOT_2
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Catalyst damaging misfires total, cylinder 2 HYUNDAI_CATDMG_MIS_TOT_2_V2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Catalyst damaging misfires total, cylinder 3 HYUNDAI_CATALYST_DAMAGING_MISFIRES_TOTAL_C3Confirmed
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Catalyst damaging misfires total, cylinder 3 HYUNDAI_CATDMG_MIS_TOT_3
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Catalyst damaging misfires total, cylinder 3 HYUNDAI_CATDMG_MIS_TOT_3_V2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Catalyst damaging misfires total, cylinder 4 HYUNDAI_CATALYST_DAMAGING_MISFIRES_TOTAL_C4Confirmed
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Catalyst damaging misfires total, cylinder 4 HYUNDAI_CATDMG_MIS_TOT_4
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Catalyst damaging misfires total, cylinder 4 HYUNDAI_CATDMG_MIS_TOT_4_V2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Catalyst damaging misfires total, cylinder 5 HYUNDAI_CATDMG_MIS_TOT_5
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Catalyst damaging misfires total, cylinder 5 HYUNDAI_CATDMG_MIS_TOT_5_V2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Catalyst damaging misfires total, cylinder 6 HYUNDAI_CATDMG_MIS_TOT_6
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Catalyst damaging misfires total, cylinder 6 HYUNDAI_CATDMG_MIS_TOT_6_V2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2024. Supported for 2015 to 2018.
Clutch solenoid duty HYUNDAI_CLUTCH_SOLENOID_DUTY
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Commanded EGR EGR_PCTSAE J1979Confirmed
- Request
01 2C - Service 01
PID 2C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2024. Supported for 2015 to 2018.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Request
01 2E - Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2015 to 2018.
Commanded throttle actuator HYUNDAI_COMMANDED_THROTTLE_ACTUATOR
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.390625)- Range
- 0 to 99.6093 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2024. Supported for 2018.
Commanded torque HYUNDAI_COMMANDED_TORQUE
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 10)- Range
- 0 to 2550 N·m
- Unit
- N·m
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Coolant fan duty HYUNDAI_COOLANT_FAN_PWM
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Coolant fan PWM HYUNDAI_CLT_FAN_PWM
- Request
22 E0 14 - Service 22
DID E014 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val × 15.21 ÷ 10000)- Range
- 0 to 99.67 %
- Unit
- %
In testing for 2007 to 2026.
Coolant temperature HYUNDAI_HVAC_COOLANT_T
- Request
22 01 02 - Service 22
DID 0102 - Module
7B3 → 7BB - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Coverage driven length HYUNDAI_CRUZ_COVERAGE_DRIVEN
- Request
22 E0 09 - Service 22
DID E009 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 392 to 423 of the reply, 32 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1000)- Range
- 0 to 4294967 km
- Unit
- km
In testing for 2007 to 2026.
Crankshaft torque HYUNDAI_CRANK_TQ
- Request
22 ED 05 - Service 22
DID ED05 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val × 600 ÷ 255)- Range
- 0 to 600 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Cylinder 1 injection time, 1st pulse HYUNDAI_CYL_1_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Cylinder 1 injection time, 2nd pulse HYUNDAI_CYL_1_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Cylinder 2 injection time, 1st pulse HYUNDAI_CYL_2_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Cylinder 2 injection time, 2nd pulse HYUNDAI_CYL_2_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Cylinder 3 injection time, 1st pulse HYUNDAI_CYL_3_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Cylinder 3 injection time, 2nd pulse HYUNDAI_CYL_3_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Cylinder 4 injection time, 1st pulse HYUNDAI_CYL_4_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Cylinder 4 injection time, 2nd pulse HYUNDAI_CYL_4_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Cylinder 5 injection time 1st pulse HYUNDAI_CYL_5_INJ_TIME_1ST
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Cylinder 5 injection time 2nd pulse HYUNDAI_CYL_5_INJ_TIME_2ND
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Cylinder 6 injection time 1st pulse HYUNDAI_CYL_6_INJ_TIME_1ST
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Cylinder 6 injection time 2nd pulse HYUNDAI_CYL_6_INJ_TIME_2ND
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Diesel particulate filter differential pressure HYUNDAI_DPF_DIFF_P
- Request
22 E0 F1 - Service 22
DID E0F1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 248 to 255 of the reply, 8 bits.
- Formula
(val × 4.3137 − 100)- Range
- -100 to 999.9935
- Unit
- Raw value
In testing for 2007 to 2026.
Diesel particulate filter differential pressure HYUNDAI_DPF_DIFF_P_7E0
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 288 to 295 of the reply, 8 bits.
- Formula
(val × 431.373 ÷ 100)- Range
- 0 to 1100
- Unit
- Raw value
In testing for 2007 to 2026.
Diesel particulate filter differential pressure HYUNDAI_DPF_DIFFERENTIAL_PRESSURE
- Request
21 1B - Service 21
PID 1B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2)- Range
- 0 to 32767.5
- Unit
- Raw value
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Diesel particulate filter load, from model HYUNDAI_DPF_LOAD_MODEL
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 296 to 303 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Diesel particulate filter regen demand counter HYUNDAI_DPF_REGEN_DEMAND_CNT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 432 to 439 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Diesel particulate filter regen success state HYUNDAI_DPF_REGEN_SUCCESS_ST
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 407 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Diesel particulate filter regen, completed state HYUNDAI_DPF_REGEN_COMPLETED
- Request
22 ED 06 - Service 22
DID ED06 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Diesel particulate filter regeneration count HYUNDAI_DPF_REGEN_CNT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 440 to 447 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Diesel particulate filter regeneration state HYUNDAI_DPF_REGEN_ST
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bit 431 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Diesel particulate filter regeneration state HYUNDAI_DPF_REGENERATION_STATEConfirmed
- Request
21 06 - Service 21
PID 06 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bit 207 of the reply.
0b0 = 0 → 0
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Diesel particulate filter soot HYUNDAI_DPF_SOOT
- Request
22 ED 1D - Service 22
DID ED1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 256 ÷ 65535)- Range
- 0 to 256
- Unit
- Raw value
In testing for 2007 to 2026.
Diesel particulate filter soot mass HYUNDAI_DPF_SOOT_MASS
- Request
22 ED 94 - Service 22
DID ED94 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val × 99 ÷ 255)- Range
- 0 to 99 g
- Unit
- g
In testing for 2007 to 2026.
Diesel particulate filter successful regeneration count HYUNDAI_DPF_SUCCESSFUL_REGEN
- Request
22 E0 F2 - Service 22
DID E0F2 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Diesel particulate filter total sulfur mass HYUNDAI_DPF_TOT_SULFUR_MASS
- Request
22 ED 29 - Service 22
DID ED29 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 0.15259)- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2007 to 2026.
Direct injection time 1 HYUNDAI_DI_TIME_1
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 1st pulse, cylinder 1 HYUNDAI_DI_TIME_1ST_CYL_1
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 1st pulse, cylinder 2 HYUNDAI_DI_TIME_1ST_CYL_2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 1st pulse, cylinder 3 HYUNDAI_DI_TIME_1ST_CYL_3
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 1st pulse, cylinder 4 HYUNDAI_DI_TIME_1ST_CYL_4
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 1st pulse, cylinder 5 HYUNDAI_CYL5_INJ_TIME_1ST
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 1st pulse, cylinder 6 HYUNDAI_CYL6_INJ_TIME_1ST
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 2 HYUNDAI_DI_TIME_2
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 2nd pulse, cylinder 1 HYUNDAI_DI_TIME_2ND_CYL_1
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 2nd pulse, cylinder 2 HYUNDAI_DI_TIME_2ND_CYL_2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 2nd pulse, cylinder 3 HYUNDAI_DI_TIME_2ND_CYL_3
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 2nd pulse, cylinder 4 HYUNDAI_DI_TIME_2ND_CYL_4
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 2nd pulse, cylinder 5 HYUNDAI_CYL5_INJ_TIME_2ND
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 2nd pulse, cylinder 6 HYUNDAI_CYL6_INJ_TIME_2ND
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 3 HYUNDAI_DI_TIME_3
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 4 HYUNDAI_DI_TIME_4
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 5 HYUNDAI_DI_TIME_5
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2007 to 2026.
Direct injection time 6 HYUNDAI_DI_TIME_6
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2007 to 2026.
Disconnector actuator motor current HYUNDAI_DISCONNECTOR_ACTUATOR_MOTOR_CURRENT
- Request
22 E0 05 - Service 22
DID E005 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits. The value is signed.
- Formula
(val × 2)- Range
- -256 to 254 A
- Unit
- A
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Disconnector disengage last time HYUNDAI_DISCONNECTOR_DISENGAGE_LAST_TIME
- Request
22 E0 05 - Service 22
DID E005 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 ms
- Unit
- ms
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Disconnector end point HYUNDAI_DISCONNECTOR_END_POINT
- Request
22 E0 05 - Service 22
DID E005 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- 0 to 511 mm
- Unit
- mm
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Disconnector inverter PWM duty HYUNDAI_DISCONNECTOR_INVERTER_PWM_DUTY
- Request
22 E0 05 - Service 22
DID E005 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 78.125 ÷ 10000)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Disconnector meet point HYUNDAI_DISCONNECTOR_MEET_POINT
- Request
22 E0 05 - Service 22
DID E005 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- 0 to 511 mm
- Unit
- mm
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Disconnector stroke position HYUNDAI_DISCONNECTOR_STROKE_POSITION
- Request
22 E0 05 - Service 22
DID E005 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- 0 to 511 mm
- Unit
- mm
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Disconnector zero count offset HYUNDAI_DISCONNECTOR_ZERO_COUNT_OFFSET
- Request
22 E0 05 - Service 22
DID E005 - Module
7E2 → 7EA - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
val- Range
- -32768 to 32767
- Unit
- Number
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Drive motor speed HYUNDAI_RPM_7E4
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 424 to 439 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2007 to 2026.
Drive motor speed HYUNDAI_RPM_V2
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 424 to 439 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Drive motor speed 2 HYUNDAI_RPM_2
- Request
22 01 01 - Service 22
DID 0101 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 440 to 455 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2007 to 2026.
Drive motor temperature HYUNDAI_DRIVE_MOTOR_T
- Request
22 E0 02 - Service 22
DID E002 - Module
7E3 → 7EB - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 100)- Range
- -327 to 327 °C
- Unit
- °C
In testing for 2007 to 2026.
Drive motor torque reference HYUNDAI_DRIVE_MOTOR_TQ
- Request
22 E0 02 - Service 22
DID E002 - Module
7E3 → 7EB - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Drive motor torque, actual HYUNDAI_DRIVE_MOTOR_TQ_ACT
- Request
22 E0 02 - Service 22
DID E002 - Module
7E3 → 7EB - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Dual-clutch transmission clutch 1, pressure sensor A HYUNDAI_DUAL_CLU_TRANS_CLU_1_P
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val × 19.53 ÷ 10000)- Range
- 0 to 127 bar
- Unit
- bar
In testing for 2007 to 2026.
Dual-clutch transmission clutch 2, pressure sensor B HYUNDAI_DUAL_CLU_TRANS_CLU_2_P_B
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val × 19.53 ÷ 10000)- Range
- 0 to 127 bar
- Unit
- bar
In testing for 2007 to 2026.
Dual-clutch transmission fluid temperature 1 HYUNDAI_DUAL_CLU_ATF_T_1
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2026.
Dual-clutch transmission fluid temperature 2 HYUNDAI_DUAL_CLU_ATF_T_2
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2026.
Dual-clutch transmission line pressure, sensor C HYUNDAI_DUAL_CLU_TRANS_LINE_P_C
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 19.53 ÷ 10000)- Range
- 0 to 127 bar
- Unit
- bar
In testing for 2007 to 2026.
EGR error EGR_ERRSAE J1979Confirmed
- Request
01 2D - Service 01
PID 2D - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2024.
Emission relevant misfires total all cylinders HYUNDAI_EMIS_MIS_TOT_ALL
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Emission relevant misfires total all cylinders HYUNDAI_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERSConfirmed
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Emission relevant misfires total, cylinder 1 HYUNDAI_EMIS_MIS_TOT_1
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Emission relevant misfires total, cylinder 1 HYUNDAI_EMIS_MIS_TOT_1_V2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Emission relevant misfires total, cylinder 1 HYUNDAI_EMISSION_RELEVANT_MISFIRES_TOTAL_C1Confirmed
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Emission relevant misfires total, cylinder 2 HYUNDAI_EMIS_MIS_TOT_2
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Emission relevant misfires total, cylinder 2 HYUNDAI_EMIS_MIS_TOT_2_V2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Emission relevant misfires total, cylinder 2 HYUNDAI_EMISSION_RELEVANT_MISFIRES_TOTAL_C2Confirmed
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Emission relevant misfires total, cylinder 3 HYUNDAI_EMIS_MIS_TOT_3
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Emission relevant misfires total, cylinder 3 HYUNDAI_EMIS_MIS_TOT_3_V2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Emission relevant misfires total, cylinder 3 HYUNDAI_EMISSION_RELEVANT_MISFIRES_TOTAL_C3Confirmed
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Emission relevant misfires total, cylinder 4 HYUNDAI_EMIS_MIS_TOT_4
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Emission relevant misfires total, cylinder 4 HYUNDAI_EMIS_MIS_TOT_4_V2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Emission relevant misfires total, cylinder 4 HYUNDAI_EMISSION_RELEVANT_MISFIRES_TOTAL_C4Confirmed
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Emission relevant misfires total, cylinder 5 HYUNDAI_EMIS_MIS_TOT_5
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Emission relevant misfires total, cylinder 5 HYUNDAI_EMIS_MIS_TOT_5_V2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Emission relevant misfires total, cylinder 6 HYUNDAI_EMIS_MIS_TOT_6
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Emission relevant misfires total, cylinder 6 HYUNDAI_EMIS_MIS_TOT_6_V2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024. Supported for 2015 to 2018.
Engine coolant temperature HYUNDAI_ENGINE_COOLANT_TConfirmed
Pelican can show this parameter as the engine coolant temperature.
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 200 to 207 of the reply, 8 bits.
0x66 = 102 → (102 × 0.75 − 48) = 28.5 °C
- Formula
(val × 0.75 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Engine coolant temperature 1 ECT_1SAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024.
Engine coolant temperature 2 ECT_2SAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bits 16 to 23 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024.
Engine oil temperature HYUNDAI_ENGINE_OIL_TConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 272 to 279 of the reply, 8 bits.
0x64 = 100 → (100 × 0.75 − 48) = 27 °C
- Formula
(val × 0.75 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Engine oil temperature HYUNDAI_EOTConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 272 to 279 of the reply, 8 bits.
0xBB = 187 → (187 × 3 ÷ 4 − 48) = 92.25 °C
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Engine oil temperature HYUNDAI_EOT_7E0
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
In testing for 2007 to 2026.
Engine oil temperature HYUNDAI_EOT_7E0_7E0
- Request
22 ED 07 - Service 22
DID ED07 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val × 0.7843 − 50)- Range
- -50 to 149.9965 °C
- Unit
- °C
In testing for 2007 to 2026.
Engine oil temperature HYUNDAI_EOT_7E0_V2
Pelican can show this parameter as the engine oil temperature.
- Request
22 ED 07 - Service 22
DID ED07 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val × 0.7843 − 50)- Range
- -50 to 149.9965 °C
- Unit
- °C
In testing for 2007 to 2026.
Engine oil temperature HYUNDAI_EOT_V2
Pelican can show this parameter as the engine oil temperature.
- Request
22 ED 02 - Service 22
DID ED02 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val − 4)- Range
- -4 to 251 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Engine Oil Temperature HYUNDAI_OIL_TEMPConfirmed
Pelican can show this parameter as the engine oil temperature.
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 272 to 279 of the reply, 8 bits.
0xBB = 187 → (187 ÷ 1.3333 − 48) = 92.253506 °C
- Formula
(val ÷ 1.3333 − 48)- Range
- 0 to 143.254781 °C
- Unit
- °C
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Engine RPM HYUNDAI_ENGINE_RPM_TCM
Pelican can show this parameter as the engine speed.
- Request
21 A0 - Service 21
PID A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Engine RPM HYUNDAI_RPM_7E5
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2007 to 2026.
Engine RPM HYUNDAI_RPM_V3
Pelican can show this parameter as the engine speed.
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2024. Supported for 2015 to 2018.
Engine run time, total HYUNDAI_ENG_RUN_TIME_TOT
- Request
21 0E - Service 21
PID 0E - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 6)- Range
- 0 to 393209.9999 min
- Unit
- min
In testing for 2007 to 2026.
Engine, actual torque HYUNDAI_ENG_ACT_TQ
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val × 23529 ÷ 10000)- Range
- 0 to 599.9895 N·m
- Unit
- N·m
In testing for 2007 to 2026.
Exhaust cam oil control valve duty HYUNDAI_OIL_CTRL_VLV_IMPULSE_WIDTH
- Request
21 20 - Service 21
PID 20 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Exhaust camshaft position HYUNDAI_EXH_CAM_POS
- Request
22 E0 20 - Service 22
DID E020 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
In testing for 2007 to 2026.
Exhaust gas flow in the particulate filter HYUNDAI_EXH_GAS_FLOW_PF
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 256 to 263 of the reply, 8 bits.
- Formula
(val × 392157 ÷ 50)- Range
- 0 to 2000000.7 L
- Unit
- L
In testing for 2007 to 2026.
Exhaust gas temperature HYUNDAI_EXH_GAS_T
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 632 to 639 of the reply, 8 bits.
- Formula
(val × 5 − 50)- Range
- -50 to 1225 °C
- Unit
- °C
In testing for 2007 to 2026.
Exhaust gas temperature HYUNDAI_EXHAUST_GAS_TConfirmed
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
5 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 368 to 375 of the reply, 8 bits.
0x00 = 0 → (0 × 4.709803922 + 99) = 99 °C
- Formula
(val × 4.709803922 + 99)- Range
- 99 to 1300 °C
- Unit
- °C
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Exhaust gas temperature at catalyst HYUNDAI_EXH_GAS_T_CAT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val × 471 ÷ 100 + 99)- Range
- 0 to 1300.05 °C
- Unit
- °C
In testing for 2007 to 2026.
Exhaust gas temperature before gasoline particulate filter sensor 1 HYUNDAI_CRUZ_EXH_GAS_T_BEFORE_GPF_1
- Request
22 E0 09 - Service 22
DID E009 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 12 ÷ 125)- Range
- 0 to 6291 °C
- Unit
- °C
In testing for 2007 to 2026.
Exhaust gas temperature before gasoline particulate filter sensor 2 HYUNDAI_CRUZ_EXH_GAS_T_BEFORE_GPF_2
- Request
22 E0 09 - Service 22
DID E009 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 12 ÷ 125)- Range
- 0 to 6291 °C
- Unit
- °C
In testing for 2007 to 2026.
Exhaust gas volume flow HYUNDAI_EXH_GAS_VOLUME_FLOW
- Request
22 E0 F1 - Service 22
DID E0F1 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val × 78449 ÷ 10000)- Range
- 0 to 2000
- Unit
- Raw value
In testing for 2007 to 2026.
Exhaust temperature 1, upstream of oxidation catalyst HYUNDAI_EXH_T_1_UP_OXICAT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 296 to 303 of the reply, 8 bits.
- Formula
(val × 4.7098 + 99)- Range
- 0 to 1299.999 °C
- Unit
- °C
In testing for 2007 to 2026.
Exhaust temperature 2, upstream of DPF HYUNDAI_EXH_T_2_UP_DPF
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
(val × 4.7098 + 99)- Range
- 0 to 1299.999 °C
- Unit
- °C
In testing for 2007 to 2026.
Front left tire temperature HYUNDAI_FL_TT
Pelican can show this parameter as the front left tire temperature.
- Request
21 06 - Service 21
PID 06 - Module
7D6 → 7DE - Every
15 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Front right tire temperature HYUNDAI_FR_TT
Pelican can show this parameter as the front right tire temperature.
- Request
21 06 - Service 21
PID 06 - Module
7D6 → 7DE - Every
15 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Gasoline direct injection time bank a, 1 HYUNDAI_GDI_IT_A1Confirmed
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 10) = 0 ms
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Gasoline direct injection time bank a, 2 HYUNDAI_GDI_IT_A2Confirmed
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 10) = 0 ms
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Gasoline direct injection time bank a, 3 HYUNDAI_GDI_IT_A3Confirmed
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 10) = 0 ms
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Gasoline direct injection time bank a, 4 HYUNDAI_GDI_IT_A4Confirmed
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 10) = 0 ms
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Gasoline direct injection time bank b, 1 HYUNDAI_GDI_IT_B1Confirmed
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 10) = 0 ms
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Gasoline direct injection time bank b, 2 HYUNDAI_GDI_IT_B2Confirmed
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 10) = 0 ms
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Gasoline direct injection time bank b, 3 HYUNDAI_GDI_IT_B3Confirmed
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 10) = 0 ms
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Gasoline direct injection time bank b, 4 HYUNDAI_GDI_IT_B4Confirmed
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 10) = 0 ms
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Glow relay duty HYUNDAI_GLOW_RELAY_DUTY
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val × 2451 ÷ 6250)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Heat HYUNDAI_HEAT
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Heat sink temperature HYUNDAI_HEAT_SINK_T
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Heat sink temperature HYUNDAI_HEAT_SINK_T_7E3
- Request
22 E0 02 - Service 22
DID E002 - Module
7E3 → 7EB - Every
5 s - Testing
Bits 344 to 359 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- -3276 to 3276 °C
- Unit
- °C
In testing for 2007 to 2026.
Hv_charging HYUNDAI_HV_CHG
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bit 72 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Idle control mode HYUNDAI_IDLE_CONTROL_MODEConfirmed
- Request
21 00 - Service 21
PID 00 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 120 to 127 of the reply, 8 bits.
0x01 = 1 → 1
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Ignition retard due to knock control 1 HYUNDAI_IGN_RETARD_KNOCK_1
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Ignition retard due to knock control 2 HYUNDAI_IGN_RETARD_KNOCK_2
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Ignition retard due to knock control 3 HYUNDAI_IGN_RETARD_KNOCK_3
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Ignition retard due to knock control 4 HYUNDAI_IGN_RETARD_KNOCK_4
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Ignition voltage HYUNDAI_IGN_VOLTAGE
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 10 ÷ 10000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Injection duration cylinder 1 HYUNDAI_CRUZ_INJ_DUR_1
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 ms
- Unit
- ms
In testing for 2007 to 2026.
Injection duration cylinder 1 HYUNDAI_INJ_DUR_1Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 1220.7) = 0 s
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 s
- Unit
- s
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Injection duration cylinder 2 HYUNDAI_CRUZ_INJ_DUR_2
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 ms
- Unit
- ms
In testing for 2007 to 2026.
Injection duration cylinder 2 HYUNDAI_INJ_DUR_2Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 1220.7) = 0 s
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 s
- Unit
- s
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Injection duration cylinder 3 HYUNDAI_CRUZ_INJ_DUR_3
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 ms
- Unit
- ms
In testing for 2007 to 2026.
Injection duration cylinder 3 HYUNDAI_INJ_DUR_3Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 1220.7) = 0 s
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 s
- Unit
- s
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Injection duration cylinder 4 HYUNDAI_CRUZ_INJ_DUR_4
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 ms
- Unit
- ms
In testing for 2007 to 2026.
Injection duration cylinder 4 HYUNDAI_INJ_DUR_4Confirmed
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 ÷ 1220.7) = 0 s
- Formula
(val ÷ 1220.7)- Range
- 0 to 53 s
- Unit
- s
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Injection duration cylinder 5 HYUNDAI_INJ_DUR_5
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.68 s
- Unit
- s
In testing for 2007 to 2026.
Injection duration cylinder 6 HYUNDAI_INJ_DUR_6
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.68 s
- Unit
- s
In testing for 2007 to 2026.
Injection impulse 1, cylinder 1 HYUNDAI_INJ_IMPULSE_1_CYL_1
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Injection impulse 1, cylinder 2 HYUNDAI_INJ_IMPULSE_1_CYL_2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Injection impulse 1, cylinder 3 HYUNDAI_INJ_IMPULSE_1_CYL_3
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Injection impulse 1, cylinder 4 HYUNDAI_INJ_IMPULSE_1_CYL_4
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Injection impulse 2, cylinder 1 HYUNDAI_INJ_IMPULSE_2_CYL_1
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Injection impulse 2, cylinder 2 HYUNDAI_INJ_IMPULSE_2_CYL_2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Injection impulse 2, cylinder 3 HYUNDAI_INJ_IMPULSE_2_CYL_3
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Injection impulse 2, cylinder 4 HYUNDAI_INJ_IMPULSE_2_CYL_4
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 250)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2007 to 2026.
Injection impulse 3, cylinder 1 HYUNDAI_INJ_IMPULSE_3_CYL_1
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 328 to 343 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 25)- Range
- 0 to 2621.4 ms
- Unit
- ms
In testing for 2007 to 2026.
Injection impulse 3, cylinder 2 HYUNDAI_INJ_IMPULSE_3_CYL_2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 344 to 359 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 25)- Range
- 0 to 2621.4 ms
- Unit
- ms
In testing for 2007 to 2026.
Injection impulse 3, cylinder 3 HYUNDAI_INJ_IMPULSE_3_CYL_3
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 25)- Range
- 0 to 2621.4 ms
- Unit
- ms
In testing for 2007 to 2026.
Injection impulse 3, cylinder 4 HYUNDAI_INJ_IMPULSE_3_CYL_4
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 25)- Range
- 0 to 2621.4 ms
- Unit
- ms
In testing for 2007 to 2026.
Injector correction factor 1 HYUNDAI_CRUZ_INJ_CORR_FACTOR_1
- Request
22 E0 07 - Service 22
DID E007 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 2
- Unit
- Number
In testing for 2007 to 2026.
Injector correction factor 2 HYUNDAI_CRUZ_INJ_CORR_FACTOR_2
- Request
22 E0 07 - Service 22
DID E007 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 2
- Unit
- Number
In testing for 2007 to 2026.
Injector correction factor 3 HYUNDAI_CRUZ_INJ_CORR_FACTOR_3
- Request
22 E0 07 - Service 22
DID E007 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 2
- Unit
- Number
In testing for 2007 to 2026.
Injector correction factor 4 HYUNDAI_CRUZ_INJ_CORR_FACTOR_4
- Request
22 E0 07 - Service 22
DID E007 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 2
- Unit
- Number
In testing for 2007 to 2026.
Intake air temperature HYUNDAI_EITConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 264 to 271 of the reply, 8 bits.
0x82 = 130 → (130 × 3 ÷ 4 − 48) = 49.5 °C
- Formula
(val × 3 ÷ 4 − 48)- Range
- -48 to 143 °C
- Unit
- °C
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Intake air temperature HYUNDAI_IAT
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 1.3333 − 48)- Range
- 0 to 143 °C
- Unit
- °C
In testing for 2007 to 2026.
Intake air temperature HYUNDAI_INTAKE_AIR_TConfirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 264 to 271 of the reply, 8 bits.
0x63 = 99 → (99 × 0.75 − 48) = 26.25 °C
- Formula
(val × 0.75 − 48)- Range
- -48 to 143.25 °C
- Unit
- °C
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Intake Air Temperature HYUNDAI_INTAKE_TEMPConfirmed
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
5 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 264 to 271 of the reply, 8 bits.
0x82 = 130 → (130 ÷ 1.3333 − 48) = 49.502438 °C
- Formula
(val ÷ 1.3333 − 48)- Range
- 0 to 143.254781 °C
- Unit
- °C
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Intake air temperature IATSAE J1979Confirmed
- Request
01 0F - Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2024. Supported for 2015 to 2018.
Intake cam oil control valve duty HYUNDAI_OIL_CTRL_VLV_IMPULSE
- Request
21 20 - Service 21
PID 20 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 144 to 151 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Intake camshaft position HYUNDAI_INT_CAM_POS
- Request
22 E0 20 - Service 22
DID E020 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
In testing for 2007 to 2026.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Request
01 0B - Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2024. Supported for 2015 to 2018.
Inverter temperature HYUNDAI_HVAC_INVERTER_T
- Request
22 01 02 - Service 22
DID 0102 - Module
7B3 → 7BB - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Inverter temperature HYUNDAI_INVERTER_T
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Inverter temperature HYUNDAI_INVERTER_T_7E3
- Request
22 01 02 - Service 22
DID 0102 - Module
7E3 → 7EB - Every
5 s - Testing
Bits 96 to 103 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2007 to 2026.
Isolation resistance HYUNDAI_ISOLATION_RES
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 456 to 471 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 kΩ
- Unit
- kΩ
In testing for 2007 to 2026.
Knock control adaptation value, cylinder 1 HYUNDAI_KNOCK_CTRL_ADPT_CYL_1
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 552 to 559 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock control adaptation value, cylinder 2 HYUNDAI_KNOCK_CTRL_ADPT_CYL_2
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 560 to 567 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock control adaptation value, cylinder 3 HYUNDAI_KNOCK_CTRL_ADPT_CYL_3
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 568 to 575 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock control adaptation value, cylinder 4 HYUNDAI_KNOCK_CTRL_ADPT_CYL_4
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 576 to 583 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock control adaptation value, cylinder 5 HYUNDAI_KNOCK_CTRL_ADPT_CYL_5
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 584 to 591 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock control adaptation value, cylinder 6 HYUNDAI_KNOCK_CTRL_ADPT_CYL_6
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 592 to 599 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock detected HYUNDAI_KNOCK_DETECTEDConfirmed
- Request
21 00 - Service 21
PID 00 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 200 to 207 of the reply, 8 bits.
0x00 = 0 → 0
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Knock detected HYUNDAI_KNOCK_DETECTED_7E0
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Knock learn, cylinder 1 HYUNDAI_KNOCK_LEARN_1Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 160 to 167 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Knock learn, cylinder 2 HYUNDAI_KNOCK_LEARN_2Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 168 to 175 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Knock learn, cylinder 3 HYUNDAI_KNOCK_LEARN_3Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 176 to 183 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Knock learn, cylinder 4 HYUNDAI_KNOCK_LEARN_4Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 184 to 191 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Knock retard cylinder 1 HYUNDAI_KNOCK_RETARD_1_E00AConfirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 96 to 103 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Knock retard cylinder 1 HYUNDAI_KNOCK_RETARD_CYL_1
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Knock retard cylinder 1 HYUNDAI_KNOCK_RETARD_CYL_1_V2
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 488 to 495 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock retard cylinder 1, alternate HYUNDAI_KNOCK_RETARD_1_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Knock retard cylinder 1, alternate HYUNDAI_KNOCK_RETARD_CYL_1_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock retard cylinder 2 HYUNDAI_KNOCK_RETARD_2_E00AConfirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 104 to 111 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Knock retard cylinder 2 HYUNDAI_KNOCK_RETARD_CYL_2
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Knock retard cylinder 2 HYUNDAI_KNOCK_RETARD_CYL_2_V2
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 496 to 503 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock retard cylinder 2, alternate HYUNDAI_KNOCK_RETARD_2_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Knock retard cylinder 2, alternate HYUNDAI_KNOCK_RETARD_CYL_2_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock retard cylinder 3 HYUNDAI_KNOCK_RETARD_3_E00AConfirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 112 to 119 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Knock retard cylinder 3 HYUNDAI_KNOCK_RETARD_CYL_3
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Knock retard cylinder 3 HYUNDAI_KNOCK_RETARD_CYL_3_V2
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 504 to 511 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock retard cylinder 3, alternate HYUNDAI_KNOCK_RETARD_3_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Knock retard cylinder 3, alternate HYUNDAI_KNOCK_RETARD_CYL_3_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock retard cylinder 4 HYUNDAI_KNOCK_RETARD_4_E00AConfirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 120 to 127 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Knock retard cylinder 4 HYUNDAI_KNOCK_RETARD_CYL_4
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Knock retard cylinder 4 HYUNDAI_KNOCK_RETARD_CYL_4_V2
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 512 to 519 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock retard cylinder 4, alternate HYUNDAI_KNOCK_RETARD_4_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Knock retard cylinder 4, alternate HYUNDAI_KNOCK_RETARD_CYL_4_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock retard cylinder 5 HYUNDAI_KNOCK_RETARD_CYL_5
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 520 to 527 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock retard cylinder 6 HYUNDAI_KNOCK_RETARD_CYL_6
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 528 to 535 of the reply, 8 bits. The value is signed.
- Formula
(val × 3 ÷ 4)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2026.
Knock retard, cylinder 1 HYUNDAI_KNOCK_RETARD_1Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 96 to 103 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Knock retard, cylinder 2 HYUNDAI_KNOCK_RETARD_2Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 104 to 111 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Knock retard, cylinder 3 HYUNDAI_KNOCK_RETARD_3Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 112 to 119 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Knock retard, cylinder 4 HYUNDAI_KNOCK_RETARD_4Confirmed
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 120 to 127 of the reply, 8 bits. The value is signed.
0x00 = 0 → (0 ÷ 5) = 0 °
- Formula
(val ÷ 5)- Range
- -25 to 25 °
- Unit
- °
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Lock switch HYUNDAI_LOCK_SWITCH
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bit 151 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Request
01 07 - Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2024. Supported for 2015 to 2018.
Long term secondary O2 sensor fuel trim (bank 1) LGSO2FT1SAE J1979Confirmed
- Request
01 56 - Service 01
PID 56 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2024.
Main injection volume HYUNDAI_MAIN_INJECTION_QTYConfirmed
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 96 to 103 of the reply, 8 bits.
0x00 = 0 → (0 × 0.392156863) = 0 L
- Formula
(val × 0.392156863)- Range
- 0 to 100 L
- Unit
- L
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Malfunction indicator HYUNDAI_MALFUNCTION_INDICATOR
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bit 175 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Mass air flow rate HYUNDAI_MAF_RATE
- Request
22 E0 10 - Service 22
DID E010 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.
- Formula
(val × 0.04239)- Range
- 0 to 10.8
- Unit
- Raw value
In testing for 2007 to 2026.
Max adaptation value for lower mechanical stop of the boost pressure actuator during engine running HYUNDAI_MAX_ADPT_LO_MECH_STOP_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 480 to 495 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Max adaptation value for lower mechanical stop of the boost pressure actuator during engine stop HYUNDAI_MAX_ADPT_LO_MECH_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 464 to 479 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Min adaptation value for lower mechanical stop of the boost pressure actuator during engine running HYUNDAI_MIN_ADPT_LO_MECH_STOP_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 512 to 527 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Min adaptation value for lower mechanical stop of the boost pressure actuator during engine stop HYUNDAI_MIN_ADPT_LO_MECH_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 496 to 511 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Misfire count #1 HYUNDAI_MIS_1Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 56 to 71 of the reply, 16 bits. The bytes are in little-endian order.
0x0B0A = 2826 → 2,826
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfire count #2 HYUNDAI_MIS_2Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 72 to 87 of the reply, 16 bits. The bytes are in little-endian order.
0x0046 = 70 → 70
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfire count #3 HYUNDAI_MIS_3Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 88 to 103 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfire count #4 HYUNDAI_MIS_4Confirmed
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 104 to 119 of the reply, 16 bits. The bytes are in little-endian order.
0x3C00 = 15360 → 15,360
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfires current total HYUNDAI_MIS_CURRENT_TOT
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 584 to 591 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Misfires current, cylinder 1 HYUNDAI_MIS_CURRENT_1
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 536 to 543 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Misfires current, cylinder 2 HYUNDAI_MIS_CURRENT_2
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 544 to 551 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Misfires current, cylinder 3 HYUNDAI_MIS_CURRENT_3
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 552 to 559 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Misfires current, cylinder 4 HYUNDAI_MIS_CURRENT_4
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 560 to 567 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Misfires current, cylinder 5 HYUNDAI_MIS_CURRENT_5
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 568 to 575 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Misfires current, cylinder 6 HYUNDAI_MIS_CURRENT_6
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 576 to 583 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Misfires harmful for catalyst, cylinder 1 HYUNDAI_MIS_HARMFUL_CAT_1
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires harmful for catalyst, cylinder 2 HYUNDAI_MIS_HARMFUL_CAT_2
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires harmful for catalyst, cylinder 3 HYUNDAI_MIS_HARMFUL_CAT_3
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires harmful for catalyst, cylinder 4 HYUNDAI_MIS_HARMFUL_CAT_4
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires, current, cylinder 1 HYUNDAI_MISFIRES_C1_CURConfirmed
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfires, current, cylinder 2 HYUNDAI_MISFIRES_C2_CURConfirmed
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfires, current, cylinder 3 HYUNDAI_MISFIRES_C3_CURConfirmed
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfires, current, cylinder 4 HYUNDAI_MISFIRES_C4_CURConfirmed
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfires, cylinder 1 HYUNDAI_MIS_1_7E0
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires, cylinder 2 HYUNDAI_MIS_2_7E0
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires, cylinder 3 HYUNDAI_MIS_3_7E0
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Misfires, cylinder 4 HYUNDAI_MIS_4_7E0
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2026.
Motor actual torque HYUNDAI_MOTOR_ACTUAL_TORQUE
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 168 to 183 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Motor phase current HYUNDAI_MOTOR_PHASE_CURRENT_RMS
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 184 to 199 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 A
- Unit
- A
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Motor RPM HYUNDAI_MOTOR_RPM
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 136 to 151 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Motor temperature HYUNDAI_MOTOR_T
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Motor temperature HYUNDAI_MOTOR_T_7E3
- Request
22 01 02 - Service 22
DID 0102 - Module
7E3 → 7EB - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2007 to 2026.
Motor-driven power steering current HYUNDAI_MDPS_MOTOR_CURRENTConfirmed
- Request
22 01 01 - Service 22
DID 0101 - Module
7D4 → 7DC - Every
250 ms - Testing
Example reply from a 2024 Hyundai i10.
Bits 88 to 95 of the reply, 8 bits. The value is signed.
0x03 = 3 → 3 A
- Formula
val- Range
- -128 to 127 A
- Unit
- A
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Niro_maximum deterioration HYUNDAI_MAX
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2007 to 2026.
Niro_minimum deterioration HYUNDAI_MIN
- Request
21 05 - Service 21
PID 05 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553 %
- Unit
- %
In testing for 2007 to 2026.
Nominal torque value HYUNDAI_NOMINAL_TORQUE_VALUE
- Request
22 E0 01 - Service 22
DID E001 - Module
7E3 → 7EB - Every
1 s - Testing
Bits 152 to 167 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 N·m
- Unit
- N·m
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
NOx trap outlet pressure HYUNDAI_NOX_TRAP_OUTLET_P
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 288 to 295 of the reply, 8 bits.
- Formula
(val × 3212451 ÷ 25000)- Range
- 0 to 32767.0002
- Unit
- Raw value
In testing for 2007 to 2026.
Number of quick charging HYUNDAI_NUM_QUICK_CHG
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 64 to 95 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2007 to 2026.
Number of standard charging HYUNDAI_NUM_STANDARD_CHG
- Request
22 01 11 - Service 22
DID 0111 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 32 to 63 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295
- Unit
- Number
In testing for 2007 to 2026.
Oil pump PWM HYUNDAI_OIL_PMP_PWM
- Request
22 ED 13 - Service 22
DID ED13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 71 of the reply.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 0.392
- Unit
- Off or on
In testing for 2007 to 2026.
Operating time HYUNDAI_OP_TIME
- Request
21 01 - Service 21
PID 01 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 368 to 399 of the reply, 32 bits.
- Formula
(val ÷ 3600)- Range
- 0 to 1193046
- Unit
- Raw value
In testing for 2007 to 2026.
Output speed HYUNDAI_OUTPUT_SPEED
- Request
21 A0 - Service 21
PID A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 88 to 103 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Overheat protection, active HYUNDAI_OVERHEAT_PROTECTION
- Request
22 E0 14 - Service 22
DID E014 - Module
7E0 → 7E8 - Every
1 s - Testing
Bit 132 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2007 to 2026.
Parking sensor rear center left level HYUNDAI_CRUZ_PARKING_SENS_REAR
- Request
22 B0 09 - Service 22
DID B009 - Module
7A0 → 7A8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Parking sensor rear center right level HYUNDAI_CRUZ_PARKING_SENS_REAR_CENTER
- Request
22 B0 09 - Service 22
DID B009 - Module
7A0 → 7A8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Pilot injection volume HYUNDAI_PILOT_INJECTION_QTYConfirmed
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 104 to 119 of the reply, 16 bits.
0x0000 = 0 → 0 L
- Formula
val- Range
- 0 to 65535 L
- Unit
- L
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Post injection volume HYUNDAI_POST_INJECTION_QTYConfirmed
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 128 to 143 of the reply, 16 bits.
0x0000 = 0 → 0 L
- Formula
val- Range
- 0 to 65535 L
- Unit
- L
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Pressure sensor HYUNDAI_PRESSURE_SENSOR
- Request
21 C0 - Service 21
PID C0 - Module
7E5 - Every
250 ms - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 4)- Range
- 0 to 63.75 bar
- Unit
- bar
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Rail pressure control valve HYUNDAI_RAIL_P_CTRL_VLV
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 55 of the reply.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 0.3921
- Unit
- Off or on
In testing for 2007 to 2026.
Rear left tire temperature HYUNDAI_RL_TT
Pelican can show this parameter as the rear left tire temperature.
- Request
21 06 - Service 21
PID 06 - Module
7D6 → 7DE - Every
15 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Rear right tire temperature HYUNDAI_RR_TT
Pelican can show this parameter as the rear right tire temperature.
- Request
21 06 - Service 21
PID 06 - Module
7D6 → 7DE - Every
15 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Regeneration demand counter by soot load HYUNDAI_REGEN_DEMAND_CNT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 320 to 327 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Requested torque HYUNDAI_REQUESTED_TORQUE
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 0.001526)- Range
- 0 to 100.0064 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Requested torque limitation from traction control HYUNDAI_REQ_TQ_LIM_TRACTION
- Request
22 ED 06 - Service 22
DID ED06 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2026.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2024. Supported for 2015 to 2018.
Short term secondary O2 sensor fuel trim (bank 1) STSO2FT1SAE J1979Confirmed
- Request
01 55 - Service 01
PID 55 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2024.
Successful regeneration state HYUNDAI_SUCCESSFUL_REGEN_ST
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
3600 s - Testing
Bits 424 to 431 of the reply, 8 bits.
- Formula
val- Range
- 0 to 1
- Unit
- Number
In testing for 2007 to 2026.
Throttle position #1 HYUNDAI_THROTTLE_POS_1
Pelican can show this parameter as the throttle position.
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.0244140625)- Range
- -800 to 799 %
- Unit
- %
In testing for 2007 to 2026.
Throttle position #1 HYUNDAI_THROTTLE_POSITION__1
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.0244140625)- Range
- -800 to 799 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Throttle position #2 HYUNDAI_THROTTLE_POS_2
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.0244140625)- Range
- -800 to 799 %
- Unit
- %
In testing for 2007 to 2026.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2024. Supported for 2015 to 2018.
Timing advance #1 HYUNDAI_TIMING_ADVANCE_1
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Timing advance #2 HYUNDAI_TIMING_ADVANCE_2
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Timing advance #3 HYUNDAI_TIMING_ADVANCE_3
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Timing advance #4 HYUNDAI_TIMING_ADVANCE_4
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Torque converter slip HYUNDAI_TORQUE_CONVERTER_SLIP
- Request
21 A0 - Service 21
PID A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 rpm
- Unit
- rpm
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Torque converter slip HYUNDAI_TORQUE_CONVERTER_SLIP_7E1
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 rpm
- Unit
- rpm
In testing for 2007 to 2026.
Torque converter slip HYUNDAI_TQ_CONV_SLIP
- Request
21 A0 - Service 21
PID A0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 rpm
- Unit
- rpm
In testing for 2007 to 2026.
Torque, actual HYUNDAI_TQ_ACT
- Request
21 05 - Service 21
PID 05 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 61 ÷ 40000)- Range
- 0 to 99.94 %
- Unit
- %
In testing for 2007 to 2026.
Total sulfur mass HYUNDAI_TOT_SULFUR_MASS
- Request
22 ED 29 - Service 22
DID ED29 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 15259 ÷ 100000)- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2007 to 2026.
Transmission fluid temperature HYUNDAI_ATF_T_7E0
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 A0 - Service 21
PID A0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2007 to 2026.
Turbine speed HYUNDAI_TURBINE_SPEED
- Request
21 A0 - Service 21
PID A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Turbo boost pressure HYUNDAI_CRUZ_TB_PRES
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 0.008291)- Range
- 0 to 543 kPa
- Unit
- kPa
In testing for 2007 to 2026.
Turbo boost pressure HYUNDAI_TB_PRES
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 0.008291)- Range
- 0 to 543.350685 kPa
- Unit
- kPa
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Turbo boost pressure HYUNDAI_TURBO_BOOST_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 829.1 ÷ 10000)- Range
- 0 to 5433
- Unit
- Raw value
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Turbo boost pressure HYUNDAI_TURBO_BOOST_P_7E0
- Request
21 21 - Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 0.008291)- Range
- 0 to 543
- Unit
- Number
In testing for 2007 to 2026.
Turbo boost pressure, absolute HYUNDAI_TURBO_BOOST
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 0.008291)- Range
- 0 to 543 kPa
- Unit
- kPa
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Request
01 51 - Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2024.
Variable valve timing temperature HYUNDAI_CVVT_T
Continuously variable valve timing temperature.
- Request
21 18 - Service 21
PID 18 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val − 48)- Range
- -48 to 207 °C
- Unit
- °C
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Waste gate duty HYUNDAI_CRUZ_WG_DUTY
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
(val × 0.00305176)- Range
- 0 to 199 %
- Unit
- %
In testing for 2007 to 2026.
Waste gate duty HYUNDAI_WASTE_GATE_DUTY
- Request
21 21 - Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
(val × 0.00305176)- Range
- 0 to 199 %
- Unit
- %
In testing for 2007 to 2026.
Waste gate duty HYUNDAI_WG_DUTY
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
(val × 0.00305176)- Range
- 0 to 199.9970916 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Waste gate position HYUNDAI_WASTE_GATE_POS
- Request
21 21 - Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 424 to 439 of the reply, 16 bits.
- Formula
(val × 0.00610352)- Range
- 0 to 399 %
- Unit
- %
In testing for 2007 to 2026.
Waste gate position HYUNDAI_WG_POS
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 - Every
1 s - Testing
Bits 424 to 439 of the reply, 16 bits.
- Formula
(val × 0.00610352)- Range
- 0 to 399.9941832 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Waste gate position HYUNDAI_WG_POSITION
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 - Every
1 s - Testing
Bits 424 to 439 of the reply, 16 bits.
- Formula
(val × 400 ÷ 65535)- Range
- 0 to 400 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Waste gate set point HYUNDAI_WG_SETPOINT
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 - Every
1 s - Testing
Bits 440 to 455 of the reply, 16 bits.
- Formula
(val × 400 ÷ 65535)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Waste gate setpoint HYUNDAI_WG_SP
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 - Every
1 s - Testing
Bits 440 to 455 of the reply, 16 bits.
- Formula
(val × 0.00610352)- Range
- 0 to 399.9941832 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Waste gate target HYUNDAI_WASTE_GATE_TGT
- Request
21 21 - Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 440 to 455 of the reply, 16 bits.
- Formula
(val × 0.00610352)- Range
- 0 to 399 %
- Unit
- %
In testing for 2007 to 2026.
Waste gate voltage HYUNDAI_CRUZ_WG_V
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val × 0.000152588)- Range
- 0 to 9.99 V
- Unit
- V
In testing for 2007 to 2026.
Waste gate voltage HYUNDAI_WG_V
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val × 0.000152588)- Range
- 0 to 9.99985458 V
- Unit
- V
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Waste gate voltage HYUNDAI_WG_VOLTAGE
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val × 10 ÷ 65535)- Range
- 0 to 10 V
- Unit
- V
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Wastegate control PWM, wastegate actuator HYUNDAI_WASTEGATE_CTRL_PWM
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 416 to 431 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 32767)- Range
- -100 to 100 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Wastegate position target, wastegate actuator HYUNDAI_WASTEGATE_POS_TGT
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 200 ÷ 32767)- Range
- -200 to 200 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Wastegate position, wastegate actuator HYUNDAI_WASTEGATE_POS
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 200 ÷ 32767)- Range
- -200 to 200 %
- Unit
- %
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Wide open throttle HYUNDAI_WIDE_OPEN_THROTTLE
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2007 to 2026.
Engine › Internal
Is ECT sensor 1 supported? ECT_1_SUPSAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2024.
Is ECT sensor 2 supported? ECT_2_SUPSAE J1979Confirmed
- Request
01 67 - Service 01
PID 67 - Module
7E0 → 7E8 - Every
1 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Number
Confirmed for 2024.
Engine › Misfires
Emission-relevant misfires, cylinder #1 HYUNDAI_MIS_CNT_EMIS_1Confirmed
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Emission-relevant misfires, cylinder #2 HYUNDAI_MIS_CNT_EMIS_2Confirmed
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Emission-relevant misfires, cylinder #3 HYUNDAI_MIS_CNT_EMIS_3Confirmed
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Emission-relevant misfires, cylinder #4 HYUNDAI_MIS_CNT_EMIS_4Confirmed
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfires harmful for catalyst cylinder 1 HYUNDAI_MIS_CAT_1
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Misfires harmful for catalyst cylinder 2 HYUNDAI_MIS_CAT_2
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Misfires harmful for catalyst cylinder 3 HYUNDAI_MIS_CAT_3
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Misfires harmful for catalyst cylinder 4 HYUNDAI_MIS_CAT_4
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Misfires total counter, all cylinders HYUNDAI_MIS_CNT_ALLConfirmed
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfires total counter, cylinder #1 HYUNDAI_MIS_CNT_1Confirmed
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfires total counter, cylinder #2 HYUNDAI_MIS_CNT_2Confirmed
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfires total counter, cylinder #3 HYUNDAI_MIS_CNT_3Confirmed
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfires total counter, cylinder #4 HYUNDAI_MIS_CNT_4Confirmed
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Example reply from a 2024 Hyundai i10.
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → 0
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2024. In testing for 2007 to 2023, 2025 to 2026.
Misfires, cylinder 1 HYUNDAI_MIS_1_V2
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Misfires, cylinder 2 HYUNDAI_MIS_2_V2
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Misfires, cylinder 3 HYUNDAI_MIS_3_V2
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Misfires, cylinder 4 HYUNDAI_MIS_4_V2
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2007 to 2023, 2025 to 2026. Not supported for 2024.
Engine › OxygenSensors
02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2015 to 2018.
02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2015 to 2018.
02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2015 to 2018.
02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2015 to 2018.
02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2015 to 2018.
02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2015 to 2018.
02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 1 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2015 to 2018.
02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed
- Request
01 13 - Service 01
PID 13 - Module
7E0 → 7E8 - Every
3600 s
Bit 0 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- No or yes
Confirmed for 2024. Supported for 2015 to 2018.
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2024.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2024.
Engine › Unknown
Engine status byte HYUNDAI_E004_BYTE0
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100
- Unit
- Number
In testing for 2007 to 2026.