Fuel parameters
The Hyundai Elantra has 22 fuel parameters.
● Confirmed◆ In testing○ Supported× Not supported
Cycle fuel consumption ELANTRA_CYCLE_FUEL_CONSConfirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 1990 to 2021, 2026
Example reply from a 2025 Hyundai Elantra.
Bits 416 to 423 of the reply, 8 bits.
0x00 = 0 → (0 × 8.478 ÷ 100) = 0
- Formula
(val × 8.478 ÷ 100)- Range
- 0 to 21.6189
- Unit
- Raw value
Confirmed for 2025. In testing for 1990 to 2015, 2017 to 2021, 2026. Supported for 2022 to 2024. Not supported for 2016.
Engine exhaust flow rate EXH_RATESAE J1979Confirmed
- Request
01 9E - Service 01
PID 9E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 5)- Range
- 0 to 13107 kg/h
- Unit
- kg/h
Confirmed for 2019, 2022 to 2025.
Engine fuel rate FUEL_RATESAE J1979Confirmed
Measured in units per hour
Pelican can show this parameter as the fuel rate.
- Request
01 5E - Service 01
PID 5E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 3212.75 L/h
- Unit
- L/h
Confirmed for 2024 to 2025. Supported for 2022.
Engine fuel rate (alternate) FUEL_RATE_ALTSAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s
Confirmed for 2019, 2022 to 2025.
Fuel cut ELANTRA_FUEL_CUTConfirmed
- Request
21 00 - Service 21
PID 00 - Module
7E0 → 7E8 - Every
1 s - Testing for 1990 to 2011, 2013 to 2015, 2017 to 2026
Example reply from a 2016 Hyundai Elantra.
Bits 88 to 95 of the reply, 8 bits.
0x0E = 14 → 14
- Formula
val- Range
- 0 to 255
- Unit
- Number
Confirmed for 2012, 2016. In testing for 1990 to 2008, 2011, 2020, 2026. Not supported for 2009 to 2010, 2013 to 2015, 2017 to 2019, 2021 to 2025.
Fuel injection timing #1 ELANTRA_FUEL_INJECTION_TIMING_1Confirmed
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing for 1990 to 2008, 2011, 2017 to 2026
Example reply from a 2016 Hyundai Elantra.
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
0x0004 = 4 → (4 × 0.8192) = 3.2768 ms
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
Confirmed for 2009 to 2010, 2012 to 2016. In testing for 1990 to 2008, 2011, 2020, 2026. Not supported for 2017 to 2019, 2021 to 2025.
Fuel injection timing #2 ELANTRA_FUEL_INJECTION_TIMING_2Confirmed
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing for 1990 to 2008, 2011, 2017 to 2026
Example reply from a 2016 Hyundai Elantra.
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
0x0004 = 4 → (4 × 0.8192) = 3.2768 ms
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
Confirmed for 2009 to 2010, 2012 to 2016. In testing for 1990 to 2008, 2011, 2020, 2026. Not supported for 2017 to 2019, 2021 to 2025.
Fuel injection timing #3 ELANTRA_FUEL_INJECTION_TIMING_3Confirmed
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing for 1990 to 2008, 2011, 2017 to 2026
Example reply from a 2016 Hyundai Elantra.
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
0x0004 = 4 → (4 × 0.8192) = 3.2768 ms
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
Confirmed for 2009 to 2010, 2012 to 2016. In testing for 1990 to 2008, 2011, 2020, 2026. Not supported for 2017 to 2019, 2021 to 2025.
Fuel injection timing #4 ELANTRA_FUEL_INJECTION_TIMING_4Confirmed
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing for 1990 to 2008, 2011, 2017 to 2026
Example reply from a 2016 Hyundai Elantra.
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
0x0004 = 4 → (4 × 0.8192) = 3.2768 ms
- Formula
(val × 0.8192)- Range
- 0 to 53686.272 ms
- Unit
- ms
Confirmed for 2009 to 2010, 2012 to 2016. In testing for 1990 to 2008, 2011, 2020, 2026. Not supported for 2017 to 2019, 2021 to 2025.
Fuel level (volume) ELANTRA_FLI_VOLConfirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 B0 02 - Service 22
DID B002 - Module
7C6 → 7CE - Every
1 s - Testing for 1990 to 2015, 2026
Example reply from a 2025 Hyundai Elantra.
Bits 32 to 39 of the reply, 8 bits.
0x04 = 4 → (4 ÷ 2) = 2 L
- Formula
(val ÷ 2)- Range
- 0 to 127.5 L
- Unit
- L
Confirmed for 2016 to 2025. In testing for 1990 to 2008, 2011, 2026. Not supported for 2009 to 2010, 2012 to 2015.
Fuel pressure ELANTRA_FUEL_P
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 53067 ÷ 10000)- Range
- 0 to 347774.5845
- Unit
- Raw value
In testing for 1990 to 2015, 2017 to 2021, 2026. Not supported for 2016, 2022 to 2025.
Fuel pressure deviation ELANTRA_FUEL_P_DEV
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 53067 ÷ 10000)- Range
- -173889.9456 to 173884.6389
- Unit
- Raw value
In testing for 1990 to 2015, 2017 to 2021, 2026. Not supported for 2016, 2022 to 2025.
Fuel pressure set point ELANTRA_FUEL_P_SET_POINT
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 53067 ÷ 10000)- Range
- 0 to 347774.5845
- Unit
- Raw value
In testing for 1990 to 2015, 2017 to 2021, 2026. Not supported for 2016, 2022 to 2025.
Fuel pressure set point deviation ELANTRA_FUEL_P_SET_POINT_DEVConfirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 1990 to 2021, 2026
Example reply from a 2025 Hyundai Elantra.
Bits 80 to 95 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
0x0000 = 0 → (0 × 53066 ÷ 10000) = 0
- Formula
(val × 53066 ÷ 10000)- Range
- -173886.6688 to 173881.3622
- Unit
- Raw value
Confirmed for 2022 to 2025. In testing for 1990 to 2015, 2017 to 2021, 2026. Not supported for 2016.
Fuel pressure, actual ELANTRA_FUEL_P_ACTConfirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 1990 to 2021, 2026
Example reply from a 2025 Hyundai Elantra.
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 53067 ÷ 10000) = 0
- Formula
(val × 53067 ÷ 10000)- Range
- 0 to 347774.5845
- Unit
- Raw value
Confirmed for 2022 to 2025. In testing for 1990 to 2015, 2017 to 2021, 2026. Not supported for 2016.
Fuel pressure, set point ELANTRA_FUEL_P_SET_POINT_7E0Confirmed
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing for 1990 to 2021, 2026
Example reply from a 2025 Hyundai Elantra.
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
0x0000 = 0 → (0 × 53067 ÷ 10000) = 0
- Formula
(val × 53067 ÷ 10000)- Range
- 0 to 347774.5845
- Unit
- Raw value
Confirmed for 2022 to 2025. In testing for 1990 to 2015, 2017 to 2021, 2026. Not supported for 2016.
Fuel system 1 status FUELSYS1SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2009, 2013, 2016 to 2017, 2019, 2022 to 2025. Supported for 1993, 2010, 2012, 2014 to 2015, 2018, 2020 to 2021.
Fuel system 2 status FUELSYS2SAE J1979Confirmed
- Request
01 03 - Service 01
PID 03 - Module
7E0 → 7E8 - Every
250 ms
Bits 8 to 15 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | OFF | Engine is off |
1 | OL | Open loop - has not yet satisfied conditions to go closed loop |
2 | CL | Closed loop - using oxygen sensor(s) as feedback for fuel control |
4 | OL-Drive | Open loop due to driving conditions (e.g. power enrichment, deceleration enleanment) |
8 | OL-Fault | Open loop - due to detected system fault |
16 | CL-Fault | Closed loop, but fault with at least one oxygen sensor - may be using single oxygen sensor for fuel control |
32 | OL B2 | Open loop - has not yet satisfied conditions to go closed loop (Bank 2) |
64 | OL-Drive B2 | Open loop due to driving conditions (Bank 2) (e.g. power enrichment, deceleration enleanment, cylinder deactivation) |
128 | OL-Fault B2 | Open loop - due to detected system fault (Bank 2) |
Confirmed for 2009, 2013, 2016 to 2017, 2019, 2022 to 2025. Supported for 1993, 2010, 2012, 2014 to 2015, 2018, 2020 to 2021.
Fuel tank level FLISAE J1979Confirmed
Pelican can show this parameter as the fuel tank level.
- Request
01 2F - Service 01
PID 2F - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2009, 2012 to 2014, 2016 to 2025. Supported for 1993, 2010, 2015.
Short term fuel % trim, bank 1 ELANTRA_STFT_B1
- Request
21 15 - Service 21
PID 15 - Module
7E0 → 7E8 - Every
1 s - Testing for 1990 to 2012, 2017 to 2026
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 0.0030517578 − 100)- Range
- 0 to 100 %
- Unit
- %
In testing for 1990 to 2008, 2011, 2020, 2026. Supported for 2013 to 2016. Not supported for 2009 to 2010, 2012, 2017 to 2019, 2021 to 2025.
Short term fuel % trim, bank 1 idle ELANTRA_STFT_B1_IDLE
- Request
21 15 - Service 21
PID 15 - Module
7E0 → 7E8 - Every
1 s - Testing for 1990 to 2012, 2017 to 2026
Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.046875)- Range
- 0 to 100 %
- Unit
- %
In testing for 1990 to 2008, 2011, 2020, 2026. Supported for 2013 to 2016. Not supported for 2009 to 2010, 2012, 2017 to 2019, 2021 to 2025.
Vehicle fuel rate VFUEL_RATESAE J1979Confirmed
- Request
01 9D - Service 01
PID 9D - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 50)- Range
- 0 to 1310.7 g/s
- Unit
- g/s