Engine parameters
The Honda M-NV has 93 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/C clutch HONDA_AC_CLU_PCM
- Request
22 26 10 - Service 22
DID 2610 - Module
DA0E → 0E - Every
1 s - Testing
Bit 262 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
A/C clutch HONDA_AC_CLUTCH
- Request
22 26 10 - Service 22
DID 2610 - Module
DA10 → 10 - Every
1 s - Testing
Bit 262 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Active cylinders HONDA_ACTIVE_CYL
- Request
22 26 15 - Service 22
DID 2615 - Module
DA10 → 10 - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
val- Range
- 0 to 6
- Unit
- Number
In testing for 2021 to 2026.
Active cylinders HONDA_ACTIVE_CYL_PCM
- Request
22 26 15 - Service 22
DID 2615 - Module
DA0E → 0E - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
val- Range
- 0 to 6
- Unit
- Number
In testing for 2021 to 2026.
Air conditioner clutch HONDA_AC_CLU_DA11
- Request
22 26 10 - Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bit 262 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
Air conditioning pressure, raw count HONDA_AC_P_RAW_CNT
- Request
22 26 13 - Service 22
DID 2613 - Module
DA11 → 11 - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Air/gas ratio HONDA_AIRGAS_RAT_PCM
- Request
22 26 11 - Service 22
DID 2611 - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 29.4 ÷ 65535)- Range
- 0 to 29.4
- Unit
- Number
In testing for 2021 to 2026.
Air/gas ratio HONDA_AIRGAS_RATIO
- Request
22 26 11 - Service 22
DID 2611 - Module
DA10 → 10 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 29.4 ÷ 65535)- Range
- 0 to 29.4
- Unit
- Number
In testing for 2021 to 2026.
Air/gas ratio HONDA_AIRGAS_RATIO_PCM
- Request
22 26 11 - Service 22
DID 2611 - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 29.4 ÷ 65535)- Range
- 0 to 29.4
- Unit
- Number
In testing for 2021 to 2026.
Air/gas ratio HONDA_AIRGAS_RATIO_V2
- Request
22 26 11 - Service 22
DID 2611 - Module
DA11 → 11 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 29.4 ÷ 65535)- Range
- 0 to 29.4
- Unit
- Number
In testing for 2021 to 2026.
Ambient air temperature, cabin HONDA_AAT_CAB
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 832 to 839 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 127 °C
- Unit
- °C
In testing for 2021 to 2026.
Ambient air temperature, outside HONDA_AAT_OUT
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 840 to 847 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 127 °C
- Unit
- °C
In testing for 2021 to 2026.
Cabin air temperature HONDA_CABIN_AIR_TEMPERATURE
- Request
22 20 01 - Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val × 1.8 + 32)- Range
- 0 to 491 °F
- Unit
- °F
In testing for 2021 to 2026.
Catalyst temperature HONDA_CAT_T
- Request
22 26 62 - Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 1500 °C
- Unit
- °C
In testing for 2021 to 2026.
DC-DC converter temperature HONDA_DC_DC_CONVERTER_TEMPERATURE
- Request
22 20 10 - Service 22
DID 2010 - Module
DBEF - Every
5 s - Testing
Bits 104 to 119 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 2021 to 2026.
Electric load detector current HONDA_ELD_ELEC_LOAD_DUTY
- Request
22 26 61 - Service 22
DID 2661 - Module
DA11 → 11 - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 A
- Unit
- A
In testing for 2021 to 2026.
Electric motor load HONDA_ELEC_MOTOR_LOAD
- Request
22 26 68 - Service 22
DID 2668 - Module
DA11 → 11 - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val × 40 ÷ 51 − 100)- Range
- -100 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Electric motor load HONDA_ELEC_MOTOR_LOAD_DA10
- Request
22 26 68 - Service 22
DID 2668 - Module
DA10 → 10 - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val × 40 ÷ 51 − 100)- Range
- -100 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Engine coolant temperature sensor 1 HONDA_ECT_1
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Engine coolant temperature sensor 2 HONDA_ECT_2
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Engine coolant temperature sensor 3 HONDA_ECT_3
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Engine coolant temperature sensor 4 HONDA_ECT_4
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Engine oil level HONDA_OIL_LEVEL
- Request
22 26 66 - Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 mm
- Unit
- mm
In testing for 2021 to 2026.
Engine oil temperature, variant 1 HONDA_EOT_VAR_1
- Request
22 26 66 - Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Engine oil temperature, variant 2 HONDA_EOT_VAR_2
- Request
22 26 66 - Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Engine oil temperature, variant 3 HONDA_EOT_VAR_3
- Request
22 26 66 - Service 22
DID 2666 - Module
DA10 → 10 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Engine oil temperature, variant 3 HONDA_EOT_VAR_3_PCM
- Request
22 26 66 - Service 22
DID 2666 - Module
DA0E → 0E - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Engine oil temperature, variant 4 HONDA_EOT_VAR_4
- Request
22 26 66 - Service 22
DID 2666 - Module
DA10 → 10 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Engine oil temperature, variant 4 HONDA_EOT_VAR_4_PCM
- Request
22 26 66 - Service 22
DID 2666 - Module
DA0E → 0E - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Evaporative purge control load HONDA_EVAP_PC_LOAD
- Request
22 26 13 - Service 22
DID 2613 - Module
DA11 → 11 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 99.61 %
- Unit
- %
In testing for 2021 to 2026.
Fuel/air commanded equivalence ratio HONDA_FUELAIR_CAR
- Request
22 26 61 - Service 22
DID 2661 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 2229.081633)- Range
- 0 to 29.4
- Unit
- Number
In testing for 2021 to 2026.
Fuel/air commanded equivalence ratio HONDA_FUELAIR_CAR_PCM
- Request
22 26 61 - Service 22
DID 2661 - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 2229.081633)- Range
- 0 to 29.4
- Unit
- Number
In testing for 2021 to 2026.
Generator HONDA_GEN
- Request
22 26 10 - Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Generator HONDA_GENERATOR
- Request
22 26 10 - Service 22
DID 2610 - Module
DA10 → 10 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Generator HONDA_GENERATOR_DA11
- Request
22 26 10 - Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Generator HONDA_GENERATOR_PCM
- Request
22 26 10 - Service 22
DID 2610 - Module
DA0E → 0E - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Knock control HONDA_KNOCK_CONTROL
ECU's determination of fuel quality.
- Request
22 26 62 - Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 2 ÷ 255)- Range
- 0 to 2
- Unit
- Raw value
In testing for 2021 to 2026.
Knock control HONDA_KNOCK_CONTROL_V2
- Request
22 26 62 - Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 1.99 ÷ 255)- Range
- 0 to 1.99
- Unit
- Number
In testing for 2021 to 2026.
Maintenance, air cleaner HONDA_MAINT_AIR_CLN
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2021 to 2026.
Maintenance, cabin filter HONDA_MAINT_CABIN_FLT
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2021 to 2026.
Maintenance, engine coolant HONDA_MAINT_COOL
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2021 to 2026.
Maintenance, general inspection HONDA_MAINT_INSP
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2021 to 2026.
Maintenance, oil & filter HONDA_MAINT_OIL_FLT
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2021 to 2026.
Maintenance, rake fluid HONDA_MAINT_BRK_FLD
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2021 to 2026.
Maintenance, spark plugs & valves HONDA_MAINT_SPARK
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2021 to 2026.
Maintenance, transmission fluid HONDA_MAINT_TRANS_FLD
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 2021 to 2026.
Misfire count #1 HONDA_MIS_1
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #1, variant 1 HONDA_MIS_CNT_1_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #1, variant 1 HONDA_MISFIRE_COUNT_1_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #1, variant 2 HONDA_MISFIRE_COUNT_1_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #1, variant 3 HONDA_MIS_CNT_1_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #1, variant 3 HONDA_MISFIRE_COUNT_1_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #2 HONDA_MIS_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #2, variant 1 HONDA_MIS_CNT_2_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #2, variant 1 HONDA_MISFIRE_COUNT_2_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #2, variant 2 HONDA_MISFIRE_COUNT_2_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #2, variant 3 HONDA_MIS_CNT_2_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #2, variant 3 HONDA_MISFIRE_COUNT_2_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #3 HONDA_MIS_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #3, variant 1 HONDA_MIS_CNT_3_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #3, variant 1 HONDA_MISFIRE_COUNT_3_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #3, variant 2 HONDA_MISFIRE_COUNT_3_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #3, variant 3 HONDA_MIS_CNT_3_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #3, variant 3 HONDA_MISFIRE_COUNT_3_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #4 HONDA_MIS_4
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #4, variant 1 HONDA_MIS_CNT_4_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #4, variant 1 HONDA_MISFIRE_COUNT_4_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #4, variant 2 HONDA_MISFIRE_COUNT_4_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #4, variant 3 HONDA_MIS_CNT_4_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #4, variant 3 HONDA_MISFIRE_COUNT_4_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #5, variant 1 HONDA_MIS_CNT_5_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #5, variant 1 HONDA_MISFIRE_COUNT_5_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #5, variant 2 HONDA_MISFIRE_COUNT_5_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #5, variant 3 HONDA_MIS_CNT_5_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #5, variant 3 HONDA_MISFIRE_COUNT_5_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #6, variant 1 HONDA_MIS_CNT_6_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #6, variant 1 HONDA_MISFIRE_COUNT_6_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #6, variant 2 HONDA_MISFIRE_COUNT_6_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #6, variant 3 HONDA_MIS_CNT_6_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count #6, variant 3 HONDA_MISFIRE_COUNT_6_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count 1 HONDA_MIS_CNT_1
- Request
22 26 63 - Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count 2 HONDA_MIS_CNT_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count 3 HONDA_MIS_CNT_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Misfire count 4 HONDA_MIS_CNT_4
- Request
22 26 63 - Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2021 to 2026.
Motor inverter, current HONDA_MOTOR_INVERTER_CURRENT
- Request
22 20 01 - Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 2021 to 2026.
Outside air temperature HONDA_OUTSIDE_AIR_TEMPERATURE
- Request
22 20 01 - Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val × 1.8 + 32)- Range
- 0 to 491 °F
- Unit
- °F
In testing for 2021 to 2026.
Transmission fluid temperature, variant 4 HONDA_ATF_T_VAR_4
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 22 01 - Service 22
DID 2201 - Module
DA1E → 1E - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Variable timing control duty HONDA_VARIABLE_TIM_CTRL
- Request
22 26 62 - Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Variable timing control duty HONDA_VTC_DUTY
How long the valve is energized versus how long it's not energized, expressed as a percentage. The higher the duty percentage, the more the cam timing is advanced toward its maximum potential.
- Request
22 26 62 - Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Variable timing control duty HONDA_VTC_DUTY_DA11
- Request
22 26 62 - Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Variable valve timing duty HONDA_VTC_DUTY_PCM
- Request
22 26 62 - Service 22
DID 2662 - Module
DA0E → 0E - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
VTEC valve control HONDA_VTEC_VALVE_CTRL
VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.
- Request
22 26 12 - Service 22
DID 2612 - Module
DA11 → 11 - Every
1 s - Testing
Bit 175 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.
VTEC valve control HONDA_VTEC_VALVE_CTRL_PCM
VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.
- Request
22 26 12 - Service 22
DID 2612 - Module
DA0E → 0E - Every
250 ms - Testing
Bit 175 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2021 to 2026.