Connectable parameters
The Honda M-NV has 22 Connectables, parameters that Pelican can monitor automatically.
● Confirmed◆ In testing○ Supported× Not supported
State of charge
State of charge HONDA_SOC
Pelican can show this parameter as the state of charge.
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2026.
Fuel tank level
Fuel level HONDA_FLV
Pelican can show this parameter as the fuel tank level.
- Request
22 70 29 - Service 22
DID 7029 - Module
DA60 → 60 - Every
30 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655 L
- Unit
- L
In testing for 2021 to 2026.
Odometer
Odometer HONDA_ODO_PCM
Pelican can show this parameter as the odometer.
- Request
22 26 60 - Service 22
DID 2660 - Module
DA0E → 0E - Every
30 s - Testing
Bits 344 to 367 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2021 to 2026.
Odometer HONDA_ODO
Pelican can show this parameter as the odometer.
- Request
22 26 60 - Service 22
DID 2660 - Module
DA10 → 10 - Every
5 s - Testing
Bits 344 to 367 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2021 to 2026.
Odometer HONDA_ODO_V2
Pelican can show this parameter as the odometer.
- Request
22 26 60 - Service 22
DID 2660 - Module
DA1D → 1D - Every
30 s - Testing
Bits 344 to 367 of the reply, 24 bits.
- Formula
val- Range
- 0 to 16777215 km
- Unit
- km
In testing for 2021 to 2026.
Front left tire pressure
Front left tire pressure HONDA_TP_FL
Pelican can show this parameter as the front left tire pressure.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 80 to 95 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Front right tire pressure
Front right tire pressure HONDA_TP_FR
Pelican can show this parameter as the front right tire pressure.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Rear left tire pressure
Rear left tire pressure HONDA_TP_RL
Pelican can show this parameter as the rear left tire pressure.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Rear right tire pressure
Rear right tire pressure HONDA_TP_RR
Pelican can show this parameter as the rear right tire pressure.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 kPa
- Unit
- kPa
In testing for 2021 to 2026.
Engine coolant temperature
Engine coolant temperature sensor 1 HONDA_ECT_1
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Engine coolant temperature sensor 2 HONDA_ECT_2
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Engine coolant temperature sensor 3 HONDA_ECT_3
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Engine coolant temperature sensor 4 HONDA_ECT_4
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.
Front left tire temperature
Front left tire temperature HONDA_TT_FL
Pelican can show this parameter as the front left tire temperature.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 200 to 207 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2021 to 2026.
Front right tire temperature
Front right tire temperature HONDA_TT_FR
Pelican can show this parameter as the front right tire temperature.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 192 to 199 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2021 to 2026.
Rear left tire temperature
Rear left tire temperature HONDA_TT_RL
Pelican can show this parameter as the rear left tire temperature.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 216 to 223 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2021 to 2026.
Rear right tire temperature
Rear right tire temperature HONDA_TT_RR
Pelican can show this parameter as the rear right tire temperature.
- Request
22 60 01 - Service 22
DID 6001 - Module
DA26 → 26 - Every
15 s - Testing
Bits 208 to 215 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 °C
- Unit
- °C
In testing for 2021 to 2026.
Starter battery voltage
High voltage battery voltage, line B HONDA_HVB_V_B
Pelican can show this parameter as the starter battery voltage.
- Request
22 20 2A - Service 22
DID 202A - Module
DA16 → 16 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 400 V
- Unit
- V
In testing for 2021 to 2026.
Traction battery current
High voltage battery total current HONDA_HVB_C_TOTAL
Pelican can show this parameter as the traction battery current.
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 456 to 471 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -100 to 200 A
- Unit
- A
In testing for 2021 to 2026.
Traction battery voltage
High voltage battery voltage HONDA_HVB_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 488 to 503 of the reply, 16 bits.
- Formula
(val ÷ 20)- Range
- 0 to 400 V
- Unit
- V
In testing for 2021 to 2026.
Transmission fluid temperature
Transmission fluid temperature HONDA_ATF_T_V2
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 30 83 - Service 22
DID 3083 - Module
DA1E → 1E - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 200 °C
- Unit
- °C
In testing for 2021 to 2026.
Transmission fluid temperature, variant 4 HONDA_ATF_T_VAR_4
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 22 01 - Service 22
DID 2201 - Module
DA1E → 1E - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2026.