Honda Fit

Electrical parameters

The Honda Fit has 6 electrical parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Brake fluid pressure FIT_BRK_FLD_PConfirmed

  • Request22 42 01
  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 168 to 183 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 5
Unit
Raw value

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Brake fluid pressure FIT_BRK_FLD_PConfirmed

  • Request22 42 01
  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 168 to 183 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 5
Unit
Raw value

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Brake pedal stroke FIT_BRK_PED_STKConfirmed

  • Request22 42 01
  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 88 to 103 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 50 mm
Unit
mm

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Brake pressure FIT_BRK_PConfirmed

  • Request22 40 05
  • Service 22DID 4005
  • ModuleDA28 → 28
  • Every1 s
  • Testing for 2001 to 2017, 2020 to 2021, 2023 to 2026

Bits 56 to 71 of the reply, 16 bits.

Formula
(val − 25)
Range
0 to 120 bar
Unit
bar

Confirmed for 2018 to 2019, 2022. In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013.

Brake switch FIT_BRK_SWConfirmed

  • Request22 40 04
  • Service 22DID 4004
  • ModuleDA28 → 28
  • Every1 s
  • Testing for 2001 to 2017, 2020 to 2021, 2023 to 2026

Bit 127 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2018 to 2019, 2022. In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2007 to 2011, 2013.

Master cylinder stroke FIT_MSTR_CYL_STKConfirmed

  • Request22 42 01
  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 232 to 247 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 mm
Unit
mm

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Slave cylinder stroke FIT_SLV_CYL_STKConfirmed

  • Request22 42 01
  • Service 22DID 4201
  • ModuleDA2A → 2A
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 248 to 263 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553.5 mm
Unit
mm

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.