Control module voltage VPWRConfirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2008 to 2010, 2013, 2018, 2020, 2022. Supported for 2007, 2011 to 2012, 2014, 2019.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Control module voltage VPWRSAE J1979Confirmed

Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.

Pelican can show this parameter as the starter battery voltage.

  • Request01 42
  • Service 01PID 42
  • Module7E0 → 7E8
  • Every10 s

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 1000)
Range
0 to 65535 V
Unit
V

Confirmed for 2008 to 2010, 2013, 2018, 2020, 2022. Supported for 2007, 2011 to 2012, 2014, 2019.

Distance traveled since last charge FIT_BAT_DISTConfirmed

  • Request22 22 40
  • Service 22DID 2240
  • ModuleDA0E → 0E
  • Every1 s
  • Testing for 2001 to 2006, 2009 to 2021, 2023 to 2026

Bits 80 to 111 of the reply, 32 bits.

Formula
val
Range
0 to 250000 km
Unit
km

Confirmed for 2007 to 2008, 2022. In testing for 2001 to 2006, 2012, 2014 to 2017, 2020 to 2021, 2023 to 2026. Not supported for 2009 to 2011, 2013, 2018 to 2019.

Enhanced Hybrid/EV Vehicle Charging State EHEV_MODESAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 1 to 2 of the reply, 2 bits.

Unit
Named states
States
Raw valueStateMeaning
0CSMCharge sustaining mode
1CDMCharge depleting mode
2CIMCharge increasing mode

Confirmed for 2020, 2022.

High voltage battery cells, max state of charge FIT_CELL_MAX_SOCConfirmed

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 584 to 599 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

High voltage battery cells, max state of charge FIT_CELL_MIN_SOCConfirmed

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 600 to 615 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 100 %
Unit
%

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

High voltage battery module 1A temperature FIT_HVB_MOD_1A_TConfirmed

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 472 to 487 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

High voltage battery module 3A temperature FIT_HVB_MOD_3A_TConfirmed

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 504 to 519 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

High voltage battery total current FIT_HVB_C_TOTALConfirmed

Pelican can show this parameter as the traction battery current.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 456 to 471 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 50)
Range
-100 to 200 A
Unit
A

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

High voltage battery voltage FIT_HVB_VConfirmed

Pelican can show this parameter as the traction battery voltage.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 488 to 503 of the reply, 16 bits.

Formula
(val ÷ 20)
Range
0 to 400 V
Unit
V

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Hybrid battery pack remaining charge BAT_SOCSAE J1979Confirmed

The percent remaining level of charge for a battery pack used for propulsion, expressed as a percentage of total useable battery energy, commonly referred to as State Of Charge (SOC).

Pelican can show this parameter as the state of charge.

  • Request01 5B
  • Service 01PID 5B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2020, 2022.

Hybrid/EV Battery System Current HEV_BATT_ASAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 47 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 A
Unit
A

Confirmed for 2020, 2022.

Hybrid/EV Battery System Voltage HEV_BATT_VSAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 64)
Range
0 to 1023.98 V
Unit
V

Confirmed for 2020, 2022.

Hybrid/EV Vehicle Charging State HEV_MODESAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 0 of the reply.

Unit
Named states
States
Raw valueStateMeaning
0CSMCharge sustaining mode
1CDMCharge depleting mode

Confirmed for 2020, 2022.

State of charge FIT_SOCConfirmed

Pelican can show this parameter as the state of charge.

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Battery › Cells

Individual cell voltage A1 FIT_CEL_V_A1Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 216 to 231 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A2 FIT_CEL_V_A2Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 232 to 247 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A3 FIT_CEL_V_A3Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 248 to 263 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A4 FIT_CEL_V_A4Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 264 to 279 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A5 FIT_CEL_V_A5Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 280 to 295 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A6 FIT_CEL_V_A6Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 296 to 311 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A7 FIT_CEL_V_A7Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 312 to 327 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A8 FIT_CEL_V_A8Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 328 to 343 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A9 FIT_CEL_V_A9Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 344 to 359 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A10 FIT_CEL_V_A10Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 360 to 375 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A11 FIT_CEL_V_A11Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 376 to 391 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A12 FIT_CEL_V_A12Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 392 to 407 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A13 FIT_CEL_V_A13Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 408 to 423 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A14 FIT_CEL_V_A14Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 424 to 439 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A15 FIT_CEL_V_A15Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 440 to 455 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A16 FIT_CEL_V_A16Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 456 to 471 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A17 FIT_CEL_V_A17Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 472 to 487 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A18 FIT_CEL_V_A18Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 488 to 503 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A19 FIT_CEL_V_A19Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 504 to 519 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A20 FIT_CEL_V_A20Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 520 to 535 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A21 FIT_CEL_V_A21Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 536 to 551 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A22 FIT_CEL_V_A22Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 552 to 567 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A23 FIT_CEL_V_A23Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 568 to 583 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A24 FIT_CEL_V_A24Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 584 to 599 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A25 FIT_CEL_V_A25Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 600 to 615 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A26 FIT_CEL_V_A26Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 616 to 631 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A27 FIT_CEL_V_A27Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 632 to 647 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A28 FIT_CEL_V_A28Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 648 to 663 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A29 FIT_CEL_V_A29Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 664 to 679 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A30 FIT_CEL_V_A30Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 680 to 695 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A31 FIT_CEL_V_A31Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 696 to 711 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A32 FIT_CEL_V_A32Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 712 to 727 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A33 FIT_CEL_V_A33Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 728 to 743 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A34 FIT_CEL_V_A34Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 744 to 759 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A35 FIT_CEL_V_A35Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 760 to 775 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A36 FIT_CEL_V_A36Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 776 to 791 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A37 FIT_CEL_V_A37Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 792 to 807 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A38 FIT_CEL_V_A38Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 808 to 823 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A39 FIT_CEL_V_A39Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 824 to 839 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A40 FIT_CEL_V_A40Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 840 to 855 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A41 FIT_CEL_V_A41Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 856 to 871 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A42 FIT_CEL_V_A42Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 872 to 887 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A43 FIT_CEL_V_A43Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 888 to 903 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A44 FIT_CEL_V_A44Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 904 to 919 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A45 FIT_CEL_V_A45Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 920 to 935 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A46 FIT_CEL_V_A46Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 936 to 951 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A47 FIT_CEL_V_A47Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 952 to 967 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Individual cell voltage A48 FIT_CEL_V_A48Confirmed

  • Request22 20 28
  • Service 22DID 2028
  • ModuleDA01 → 01
  • Every1 s
  • Testing for 2001 to 2021, 2023 to 2026

Bits 968 to 983 of the reply, 16 bits.

Formula
(val ÷ 5)
Range
0 to 5000 mV
Unit
mV

Confirmed for 2022. In testing for 2020 to 2021, 2023 to 2026.

Battery › Internal

Enhanced Hybrid/EV Vehicle Charging State supported? EHEV_MODE_SUPSAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2022.

Hybrid/EV Battery Current supported? HEV_BATT_A_SUPSAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2022.

Hybrid/EV Battery Voltage supported? HEV_BATT_V_SUPSAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2022.

Hybrid/EV Vehicle Charging State supported? HEV_MODE_SUPSAE J1979Confirmed

  • Request01 9A
  • Service 01PID 9A
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2020, 2022.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.