Honda City

Engine parameters

The Honda City has 113 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C clutch HONDA_AC_CLU_PCM

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C clutch HONDA_AC_CLU_PCM

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

A/C clutch HONDA_AC_CLUTCHConfirmed

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.

Absolute load value LOAD_ABSSAE J1979Confirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2014, 2023.

Active cylinders HONDA_ACTIVE_CYL

  • Request22 26 15
  • Service 22DID 2615
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2023.

Active cylinders HONDA_ACTIVE_CYL_PCM

  • Request22 26 15
  • Service 22DID 2615
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 400 to 407 of the reply, 8 bits.

Formula
val
Range
0 to 6
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Air conditioner clutch HONDA_AC_CLU_DA11

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bit 262 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Air conditioning pressure, raw count HONDA_AC_P_RAW_CNT

  • Request22 26 13
  • Service 22DID 2613
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 120 to 135 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2026.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2014, 2023.

Air/gas ratio HONDA_AIRGAS_RAT_PCM

  • Request22 26 11
  • Service 22DID 2611
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 29.4 ÷ 65535)
Range
0 to 29.4
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Air/gas ratio HONDA_AIRGAS_RATIOConfirmed

  • Request22 26 11
  • Service 22DID 2611
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 29.4 ÷ 65535)
Range
0 to 29.4
Unit
Number

Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.

Air/gas ratio HONDA_AIRGAS_RATIO_PCM

  • Request22 26 11
  • Service 22DID 2611
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 29.4 ÷ 65535)
Range
0 to 29.4
Unit
Number

In testing for 1988 to 1994, 1996 to 2026.

Air/gas ratio HONDA_AIRGAS_RATIO_V2

  • Request22 26 11
  • Service 22DID 2611
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val × 29.4 ÷ 65535)
Range
0 to 29.4
Unit
Number

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2023.

Ambient air temperature, cabin HONDA_AAT_CAB

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 832 to 839 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 127 °C
Unit
°C

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.

Ambient air temperature, outside HONDA_AAT_OUT

  • Request22 20 2A
  • Service 22DID 202A
  • ModuleDA01 → 01
  • Every1 s
  • Testing

Bits 840 to 847 of the reply, 8 bits. The value is signed.

Formula
val
Range
-40 to 127 °C
Unit
°C

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Request01 33
  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2014. Supported for 2023.

Cabin air temperature HONDA_CABIN_AIR_TEMPERATURE

  • Request22 20 01
  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
(val × 1.8 + 32)
Range
0 to 491 °F
Unit
°F

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2014, 2023. Supported for 2006.

Catalyst temperature HONDA_CAT_T

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 96 to 111 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 1500 °C
Unit
°C

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2023.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Request01 3C
  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2014.

Commanded EGR EGR_PCTSAE J1979Confirmed

  • Request01 2C
  • Service 01PID 2C
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2014. Supported for 2023.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2014, 2023.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Request01 2E
  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2014. Supported for 2023.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Request01 4C
  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2014. Supported for 2023.

DC-DC converter temperature HONDA_DC_DC_CONVERTER_TEMPERATURE

  • Request22 20 10
  • Service 22DID 2010
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 3276.7 °C
Unit
°C

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

EGR error EGR_ERRSAE J1979Confirmed

  • Request01 2D
  • Service 01PID 2D
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2014. Supported for 2023.

Electric load detector current HONDA_ELD_ELEC_LOAD_DUTY

  • Request22 26 61
  • Service 22DID 2661
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 136 to 143 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 A
Unit
A

In testing for 1988 to 1994, 1996 to 2026.

Electric motor load HONDA_ELEC_MOTOR_LOAD

  • Request22 26 68
  • Service 22DID 2668
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
(val × 40 ÷ 51 − 100)
Range
-100 to 100 %
Unit
%

In testing for 1988 to 1994, 1996 to 2026.

Electric motor load HONDA_ELEC_MOTOR_LOAD_DA10

  • Request22 26 68
  • Service 22DID 2668
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 216 to 223 of the reply, 8 bits.

Formula
(val × 40 ÷ 51 − 100)
Range
-100 to 100 %
Unit
%

In testing for 1988 to 1994, 1996 to 2026.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2014. Supported for 2006, 2023.

Engine coolant temperature sensor 1 HONDA_ECT_1

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.

Engine coolant temperature sensor 2 HONDA_ECT_2

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.

Engine coolant temperature sensor 3 HONDA_ECT_3

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.

Engine coolant temperature sensor 4 HONDA_ECT_4

Pelican can show this parameter as the engine coolant temperature.

  • Request22 20 2C
  • Service 22DID 202C
  • ModuleDA01 → 01
  • Every5 s
  • Testing

Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.

Engine oil level HONDA_OIL_LEVEL

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 mm
Unit
mm

In testing for 1988 to 1994, 1996 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2014, 2023.

Engine oil temperature, variant 1 HONDA_EOT_VAR_1

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1994, 1996 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2014, 2023.

Engine oil temperature, variant 2 HONDA_EOT_VAR_2

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1994, 1996 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2014, 2023.

Engine oil temperature, variant 3 HONDA_EOT_VAR_3

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Engine oil temperature, variant 3 HONDA_EOT_VAR_3_PCM

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA0E → 0E
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Engine oil temperature, variant 4 HONDA_EOT_VAR_4

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA10 → 10
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Engine oil temperature, variant 4 HONDA_EOT_VAR_4_PCM

  • Request22 26 66
  • Service 22DID 2666
  • ModuleDA0E → 0E
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2014, 2023. Supported for 2006.

Evaporative purge control load HONDA_EVAP_PC_LOAD

  • Request22 26 13
  • Service 22DID 2613
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 99.61 %
Unit
%

In testing for 1988 to 1994, 1996 to 2026.

Fuel/air commanded equivalence ratio HONDA_FUELAIR_CARConfirmed

  • Request22 26 61
  • Service 22DID 2661
  • ModuleDA10 → 10
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 2229.081633)
Range
0 to 29.4
Unit
Number

Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.

Fuel/air commanded equivalence ratio HONDA_FUELAIR_CAR_PCM

  • Request22 26 61
  • Service 22DID 2661
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits.

Formula
(val ÷ 2229.081633)
Range
0 to 29.4
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Generator HONDA_GEN

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Generator HONDA_GENERATORConfirmed

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.

Generator HONDA_GENERATOR_DA11

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Generator HONDA_GENERATOR_PCM

  • Request22 26 10
  • Service 22DID 2610
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Intake air temperature IATSAE J1979Confirmed

  • Request01 0F
  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2014. Supported for 2006.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Request01 0B
  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2014. Supported for 2006, 2023.

Knock control HONDA_KNOCK_CONTROLConfirmed

ECU's determination of fuel quality.

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
(val × 2 ÷ 255)
Range
0 to 2
Unit
Raw value

Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.

Knock control HONDA_KNOCK_CONTROL_V2

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
(val × 1.99 ÷ 255)
Range
0 to 1.99
Unit
Number

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2023.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Request01 07
  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2014. Supported for 2006, 2023.

Maintenance, air cleaner HONDA_MAINT_AIR_CLN

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.

Maintenance, cabin filter HONDA_MAINT_CABIN_FLT

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.

Maintenance, engine coolant HONDA_MAINT_COOL

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.

Maintenance, general inspection HONDA_MAINT_INSP

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.

Maintenance, oil & filter HONDA_MAINT_OIL_FLT

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 112 to 127 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.

Maintenance, rake fluid HONDA_MAINT_BRK_FLD

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.

Maintenance, spark plugs & valves HONDA_MAINT_SPARK

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.

Maintenance, transmission fluid HONDA_MAINT_TRANS_FLD

  • Request22 70 60
  • Service 22DID 7060
  • ModuleDA60 → 60
  • Every30 s
  • Testing

Bits 256 to 271 of the reply, 16 bits.

Formula
val
Range
0 to 9999
Unit
Raw value

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.

Misfire count #1 HONDA_MIS_1Confirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.

Misfire count #1, variant 1 HONDA_MIS_CNT_1_VAR_1_PCM

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #1, variant 1 HONDA_MISFIRE_COUNT_1_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #1, variant 2 HONDA_MISFIRE_COUNT_1_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #1, variant 3 HONDA_MIS_CNT_1_VAR_3_PCM

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #1, variant 3 HONDA_MISFIRE_COUNT_1_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #2 HONDA_MIS_2Confirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.

Misfire count #2, variant 1 HONDA_MIS_CNT_2_VAR_1_PCM

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #2, variant 1 HONDA_MISFIRE_COUNT_2_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #2, variant 2 HONDA_MISFIRE_COUNT_2_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #2, variant 3 HONDA_MIS_CNT_2_VAR_3_PCM

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #2, variant 3 HONDA_MISFIRE_COUNT_2_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #3 HONDA_MIS_3Confirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.

Misfire count #3, variant 1 HONDA_MIS_CNT_3_VAR_1_PCM

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #3, variant 1 HONDA_MISFIRE_COUNT_3_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #3, variant 2 HONDA_MISFIRE_COUNT_3_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #3, variant 3 HONDA_MIS_CNT_3_VAR_3_PCM

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #3, variant 3 HONDA_MISFIRE_COUNT_3_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #4 HONDA_MIS_4Confirmed

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA10 → 10
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.

Misfire count #4, variant 1 HONDA_MIS_CNT_4_VAR_1_PCM

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #4, variant 1 HONDA_MISFIRE_COUNT_4_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #4, variant 2 HONDA_MISFIRE_COUNT_4_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #4, variant 3 HONDA_MIS_CNT_4_VAR_3_PCM

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #4, variant 3 HONDA_MISFIRE_COUNT_4_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #5, variant 1 HONDA_MIS_CNT_5_VAR_1_PCM

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #5, variant 1 HONDA_MISFIRE_COUNT_5_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 80 to 87 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #5, variant 2 HONDA_MISFIRE_COUNT_5_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #5, variant 3 HONDA_MIS_CNT_5_VAR_3_PCM

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #5, variant 3 HONDA_MISFIRE_COUNT_5_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #6, variant 1 HONDA_MIS_CNT_6_VAR_1_PCM

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #6, variant 1 HONDA_MISFIRE_COUNT_6_VAR_1

  • Request22 26 6C
  • Service 22DID 266C
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #6, variant 2 HONDA_MISFIRE_COUNT_6_VAR_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #6, variant 3 HONDA_MIS_CNT_6_VAR_3_PCM

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count #6, variant 3 HONDA_MISFIRE_COUNT_6_VAR_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bits 240 to 255 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count 1 HONDA_MIS_CNT_1

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count 2 HONDA_MIS_CNT_2

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count 3 HONDA_MIS_CNT_3

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Misfire count 4 HONDA_MIS_CNT_4

  • Request22 26 63
  • Service 22DID 2663
  • ModuleDA1D → 1D
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Motor inverter, current HONDA_MOTOR_INVERTER_CURRENT

  • Request22 20 01
  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327.68 to 327.67 A
Unit
A

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Outside air temperature HONDA_OUTSIDE_AIR_TEMPERATURE

  • Request22 20 01
  • Service 22DID 2001
  • ModuleDBEF
  • Every5 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
(val × 1.8 + 32)
Range
0 to 491 °F
Unit
°F

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2014, 2023. Supported for 2006.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Request01 0E
  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

Confirmed for 2014. Supported for 2006, 2023.

Transmission fluid temperature, variant 4 HONDA_ATF_T_VAR_4

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 22 01
  • Service 22DID 2201
  • ModuleDA1E → 1E
  • Every5 s
  • Testing

Bits 208 to 215 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Request01 51
  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2014. Supported for 2023.

Variable timing control duty HONDA_VARIABLE_TIM_CTRL

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2023.

Variable timing control duty HONDA_VTC_DUTYConfirmed

How long the valve is energized versus how long it's not energized, expressed as a percentage. The higher the duty percentage, the more the cam timing is advanced toward its maximum potential.

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA10 → 10
  • Every250 ms
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.

Variable timing control duty HONDA_VTC_DUTY_DA11

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA11 → 11
  • Every5 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2023.

Variable valve timing duty HONDA_VTC_DUTY_PCM

  • Request22 26 62
  • Service 22DID 2662
  • ModuleDA0E → 0E
  • Every1 s
  • Testing

Bits 224 to 231 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

VTEC valve control HONDA_VTEC_VALVE_CTRL

VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.

  • Request22 26 12
  • Service 22DID 2612
  • ModuleDA11 → 11
  • Every1 s
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2023.

VTEC valve control HONDA_VTEC_VALVE_CTRL_PCM

VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.

  • Request22 26 12
  • Service 22DID 2612
  • ModuleDA0E → 0E
  • Every250 ms
  • Testing

Bit 175 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.

Engine › OxygenSensors

Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed

Pelican can show this parameter as the O2 lambda.

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 32768)
Range
0 to 1.99
Unit
Number

Confirmed for 2023.

Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed

  • Request01 34
  • Service 01PID 34
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 256 − 128)
Range
-128 to 127.996 mA
Unit
mA

Confirmed for 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.