Engine parameters
The Honda City has 113 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/C clutch HONDA_AC_CLU_PCM
- Request
22 26 10 - Service 22
DID 2610 - Module
DA0E → 0E - Every
1 s - Testing
Bit 262 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
A/C clutch HONDA_AC_CLUTCHConfirmed
- Request
22 26 10 - Service 22
DID 2610 - Module
DA10 → 10 - Every
1 s - Testing
Bit 262 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.
Absolute load value LOAD_ABSSAE J1979Confirmed
- Request
01 43 - Service 01
PID 43 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 25700 %
- Unit
- %
Confirmed for 2014, 2023.
Active cylinders HONDA_ACTIVE_CYL
- Request
22 26 15 - Service 22
DID 2615 - Module
DA10 → 10 - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
val- Range
- 0 to 6
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2023.
Active cylinders HONDA_ACTIVE_CYL_PCM
- Request
22 26 15 - Service 22
DID 2615 - Module
DA0E → 0E - Every
1 s - Testing
Bits 400 to 407 of the reply, 8 bits.
- Formula
val- Range
- 0 to 6
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Air conditioner clutch HONDA_AC_CLU_DA11
- Request
22 26 10 - Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bit 262 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Air conditioning pressure, raw count HONDA_AC_P_RAW_CNT
- Request
22 26 13 - Service 22
DID 2613 - Module
DA11 → 11 - Every
1 s - Testing
Bits 120 to 135 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2026.
Air flow rate from mass air flow sensor MAFSAE J1979Confirmed
Pelican can show this parameter as the mass air flow.
- Request
01 10 - Service 01
PID 10 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 g/s
- Unit
- g/s
Confirmed for 2014, 2023.
Air/gas ratio HONDA_AIRGAS_RAT_PCM
- Request
22 26 11 - Service 22
DID 2611 - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 29.4 ÷ 65535)- Range
- 0 to 29.4
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Air/gas ratio HONDA_AIRGAS_RATIOConfirmed
- Request
22 26 11 - Service 22
DID 2611 - Module
DA10 → 10 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 29.4 ÷ 65535)- Range
- 0 to 29.4
- Unit
- Number
Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.
Air/gas ratio HONDA_AIRGAS_RATIO_PCM
- Request
22 26 11 - Service 22
DID 2611 - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 29.4 ÷ 65535)- Range
- 0 to 29.4
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2026.
Air/gas ratio HONDA_AIRGAS_RATIO_V2
- Request
22 26 11 - Service 22
DID 2611 - Module
DA11 → 11 - Every
5 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val × 29.4 ÷ 65535)- Range
- 0 to 29.4
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2023.
Ambient air temperature, cabin HONDA_AAT_CAB
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 832 to 839 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 127 °C
- Unit
- °C
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.
Ambient air temperature, outside HONDA_AAT_OUT
- Request
22 20 2A - Service 22
DID 202A - Module
DA01 → 01 - Every
1 s - Testing
Bits 840 to 847 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -40 to 127 °C
- Unit
- °C
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.
Barometric pressure BAROSAE J1979Confirmed
Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.
- Request
01 33 - Service 01
PID 33 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2014. Supported for 2023.
Cabin air temperature HONDA_CABIN_AIR_TEMPERATURE
- Request
22 20 01 - Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
(val × 1.8 + 32)- Range
- 0 to 491 °F
- Unit
- °F
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Calculated engine load LOAD_PCTSAE J1979Confirmed
Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.
Pelican can show this parameter as the engine load.
- Request
01 04 - Service 01
PID 04 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2014, 2023. Supported for 2006.
Catalyst temperature HONDA_CAT_T
- Request
22 26 62 - Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 1500 °C
- Unit
- °C
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2023.
Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed
- Request
01 3C - Service 01
PID 3C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
Confirmed for 2014.
Commanded EGR EGR_PCTSAE J1979Confirmed
- Request
01 2C - Service 01
PID 2C - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2014. Supported for 2023.
Commanded equivalence ratio EQ_RATSAE J1979Confirmed
Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.
Pelican can show this parameter as the commanded lambda.
- Request
01 44 - Service 01
PID 44 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 2 ÷ 65535)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2014, 2023.
Commanded evaporative purge EVAP_PCTSAE J1979Confirmed
- Request
01 2E - Service 01
PID 2E - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2014. Supported for 2023.
Commanded throttle actuator control TAC_PCTSAE J1979Confirmed
- Request
01 4C - Service 01
PID 4C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2014. Supported for 2023.
DC-DC converter temperature HONDA_DC_DC_CONVERTER_TEMPERATURE
- Request
22 20 10 - Service 22
DID 2010 - Module
DBEF - Every
5 s - Testing
Bits 104 to 119 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 3276.7 °C
- Unit
- °C
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
EGR error EGR_ERRSAE J1979Confirmed
- Request
01 2D - Service 01
PID 2D - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.22 %
- Unit
- %
Confirmed for 2014. Supported for 2023.
Electric load detector current HONDA_ELD_ELEC_LOAD_DUTY
- Request
22 26 61 - Service 22
DID 2661 - Module
DA11 → 11 - Every
1 s - Testing
Bits 136 to 143 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127 A
- Unit
- A
In testing for 1988 to 1994, 1996 to 2026.
Electric motor load HONDA_ELEC_MOTOR_LOAD
- Request
22 26 68 - Service 22
DID 2668 - Module
DA11 → 11 - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val × 40 ÷ 51 − 100)- Range
- -100 to 100 %
- Unit
- %
In testing for 1988 to 1994, 1996 to 2026.
Electric motor load HONDA_ELEC_MOTOR_LOAD_DA10
- Request
22 26 68 - Service 22
DID 2668 - Module
DA10 → 10 - Every
1 s - Testing
Bits 216 to 223 of the reply, 8 bits.
- Formula
(val × 40 ÷ 51 − 100)- Range
- -100 to 100 %
- Unit
- %
In testing for 1988 to 1994, 1996 to 2026.
Engine coolant temperature ECTSAE J1979Confirmed
Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.
Pelican can show this parameter as the engine coolant temperature.
- Request
01 05 - Service 01
PID 05 - Module
7E0 → 7E8 - Every
500 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2014. Supported for 2006, 2023.
Engine coolant temperature sensor 1 HONDA_ECT_1
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,608 to 1,623 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.
Engine coolant temperature sensor 2 HONDA_ECT_2
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,624 to 1,639 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.
Engine coolant temperature sensor 3 HONDA_ECT_3
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,640 to 1,655 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.
Engine coolant temperature sensor 4 HONDA_ECT_4
Pelican can show this parameter as the engine coolant temperature.
- Request
22 20 2C - Service 22
DID 202C - Module
DA01 → 01 - Every
5 s - Testing
Bits 1,656 to 1,671 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.
Engine oil level HONDA_OIL_LEVEL
- Request
22 26 66 - Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 mm
- Unit
- mm
In testing for 1988 to 1994, 1996 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2014, 2023.
Engine oil temperature, variant 1 HONDA_EOT_VAR_1
- Request
22 26 66 - Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1994, 1996 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2014, 2023.
Engine oil temperature, variant 2 HONDA_EOT_VAR_2
- Request
22 26 66 - Service 22
DID 2666 - Module
DA11 → 11 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1994, 1996 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2014, 2023.
Engine oil temperature, variant 3 HONDA_EOT_VAR_3
- Request
22 26 66 - Service 22
DID 2666 - Module
DA10 → 10 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Engine oil temperature, variant 3 HONDA_EOT_VAR_3_PCM
- Request
22 26 66 - Service 22
DID 2666 - Module
DA0E → 0E - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Engine oil temperature, variant 4 HONDA_EOT_VAR_4
- Request
22 26 66 - Service 22
DID 2666 - Module
DA10 → 10 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Engine oil temperature, variant 4 HONDA_EOT_VAR_4_PCM
- Request
22 26 66 - Service 22
DID 2666 - Module
DA0E → 0E - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Engine RPM RPMSAE J1979Confirmed
- Request
01 0C - Service 01
PID 0C - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 rpm
- Unit
- rpm
Confirmed for 2014, 2023. Supported for 2006.
Evaporative purge control load HONDA_EVAP_PC_LOAD
- Request
22 26 13 - Service 22
DID 2613 - Module
DA11 → 11 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 99.61 %
- Unit
- %
In testing for 1988 to 1994, 1996 to 2026.
Fuel/air commanded equivalence ratio HONDA_FUELAIR_CARConfirmed
- Request
22 26 61 - Service 22
DID 2661 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 2229.081633)- Range
- 0 to 29.4
- Unit
- Number
Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.
Fuel/air commanded equivalence ratio HONDA_FUELAIR_CAR_PCM
- Request
22 26 61 - Service 22
DID 2661 - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits.
- Formula
(val ÷ 2229.081633)- Range
- 0 to 29.4
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Generator HONDA_GEN
- Request
22 26 10 - Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Generator HONDA_GENERATORConfirmed
- Request
22 26 10 - Service 22
DID 2610 - Module
DA10 → 10 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.
Generator HONDA_GENERATOR_DA11
- Request
22 26 10 - Service 22
DID 2610 - Module
DA11 → 11 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Generator HONDA_GENERATOR_PCM
- Request
22 26 10 - Service 22
DID 2610 - Module
DA0E → 0E - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Intake air temperature IATSAE J1979Confirmed
- Request
01 0F - Service 01
PID 0F - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
Confirmed for 2014. Supported for 2006.
Intake manifold absolute pressure MAPSAE J1979Confirmed
- Request
01 0B - Service 01
PID 0B - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255 kPa
- Unit
- kPa
Confirmed for 2014. Supported for 2006, 2023.
Knock control HONDA_KNOCK_CONTROLConfirmed
ECU's determination of fuel quality.
- Request
22 26 62 - Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 2 ÷ 255)- Range
- 0 to 2
- Unit
- Raw value
Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.
Knock control HONDA_KNOCK_CONTROL_V2
- Request
22 26 62 - Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 1.99 ÷ 255)- Range
- 0 to 1.99
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2023.
Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed
- Request
01 07 - Service 01
PID 07 - Module
7E0 → 7E8 - Every
1 s
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2014. Supported for 2006, 2023.
Maintenance, air cleaner HONDA_MAINT_AIR_CLN
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.
Maintenance, cabin filter HONDA_MAINT_CABIN_FLT
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.
Maintenance, engine coolant HONDA_MAINT_COOL
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.
Maintenance, general inspection HONDA_MAINT_INSP
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.
Maintenance, oil & filter HONDA_MAINT_OIL_FLT
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 112 to 127 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.
Maintenance, rake fluid HONDA_MAINT_BRK_FLD
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.
Maintenance, spark plugs & valves HONDA_MAINT_SPARK
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.
Maintenance, transmission fluid HONDA_MAINT_TRANS_FLD
- Request
22 70 60 - Service 22
DID 7060 - Module
DA60 → 60 - Every
30 s - Testing
Bits 256 to 271 of the reply, 16 bits.
- Formula
val- Range
- 0 to 9999
- Unit
- Raw value
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2022, 2024 to 2026. Not supported for 2006, 2023.
Misfire count #1 HONDA_MIS_1Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.
Misfire count #1, variant 1 HONDA_MIS_CNT_1_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #1, variant 1 HONDA_MISFIRE_COUNT_1_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #1, variant 2 HONDA_MISFIRE_COUNT_1_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #1, variant 3 HONDA_MIS_CNT_1_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #1, variant 3 HONDA_MISFIRE_COUNT_1_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #2 HONDA_MIS_2Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.
Misfire count #2, variant 1 HONDA_MIS_CNT_2_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #2, variant 1 HONDA_MISFIRE_COUNT_2_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #2, variant 2 HONDA_MISFIRE_COUNT_2_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #2, variant 3 HONDA_MIS_CNT_2_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #2, variant 3 HONDA_MISFIRE_COUNT_2_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #3 HONDA_MIS_3Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.
Misfire count #3, variant 1 HONDA_MIS_CNT_3_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #3, variant 1 HONDA_MISFIRE_COUNT_3_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 64 to 71 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #3, variant 2 HONDA_MISFIRE_COUNT_3_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #3, variant 3 HONDA_MIS_CNT_3_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #3, variant 3 HONDA_MISFIRE_COUNT_3_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #4 HONDA_MIS_4Confirmed
- Request
22 26 63 - Service 22
DID 2663 - Module
DA10 → 10 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.
Misfire count #4, variant 1 HONDA_MIS_CNT_4_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #4, variant 1 HONDA_MISFIRE_COUNT_4_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #4, variant 2 HONDA_MISFIRE_COUNT_4_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #4, variant 3 HONDA_MIS_CNT_4_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #4, variant 3 HONDA_MISFIRE_COUNT_4_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #5, variant 1 HONDA_MIS_CNT_5_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #5, variant 1 HONDA_MISFIRE_COUNT_5_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #5, variant 2 HONDA_MISFIRE_COUNT_5_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #5, variant 3 HONDA_MIS_CNT_5_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #5, variant 3 HONDA_MISFIRE_COUNT_5_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #6, variant 1 HONDA_MIS_CNT_6_VAR_1_PCM
- Request
22 26 6C - Service 22
DID 266C - Module
DA0E → 0E - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #6, variant 1 HONDA_MISFIRE_COUNT_6_VAR_1
- Request
22 26 6C - Service 22
DID 266C - Module
DA11 → 11 - Every
1 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #6, variant 2 HONDA_MISFIRE_COUNT_6_VAR_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #6, variant 3 HONDA_MIS_CNT_6_VAR_3_PCM
- Request
22 26 63 - Service 22
DID 2663 - Module
DA0E → 0E - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count #6, variant 3 HONDA_MISFIRE_COUNT_6_VAR_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA11 → 11 - Every
1 s - Testing
Bits 240 to 255 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count 1 HONDA_MIS_CNT_1
- Request
22 26 63 - Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count 2 HONDA_MIS_CNT_2
- Request
22 26 63 - Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count 3 HONDA_MIS_CNT_3
- Request
22 26 63 - Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Misfire count 4 HONDA_MIS_CNT_4
- Request
22 26 63 - Service 22
DID 2663 - Module
DA1D → 1D - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Motor inverter, current HONDA_MOTOR_INVERTER_CURRENT
- Request
22 20 01 - Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 100)- Range
- -327.68 to 327.67 A
- Unit
- A
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Outside air temperature HONDA_OUTSIDE_AIR_TEMPERATURE
- Request
22 20 01 - Service 22
DID 2001 - Module
DBEF - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val × 1.8 + 32)- Range
- 0 to 491 °F
- Unit
- °F
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed
Correction being used by the closed-loop fuel algorithm.
Pelican can show this parameter as the short term fuel trim.
- Request
01 06 - Service 01
PID 06 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 128 − 100)- Range
- -100 to 99.2 %
- Unit
- %
Confirmed for 2014, 2023. Supported for 2006.
Timing advance SPARKADVSAE J1979Confirmed
Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.
- Request
01 0E - Service 01
PID 0E - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2 − 64)- Range
- -64 to 63.5 °
- Unit
- °
Confirmed for 2014. Supported for 2006, 2023.
Transmission fluid temperature, variant 4 HONDA_ATF_T_VAR_4
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 22 01 - Service 22
DID 2201 - Module
DA1E → 1E - Every
5 s - Testing
Bits 208 to 215 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed
- Request
01 51 - Service 01
PID 51 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | GAS | Gasoline/petrol |
2 | METH | Methanol |
3 | ETH | Ethanol |
4 | DSL | Diesel |
5 | LPG | Liquefied petroleum gas |
6 | CNG | Compressed natural gas |
7 | PROP | Propane |
8 | ELEC | Battery/electric |
9 | BI_GAS | Bi-fuel vehicle using gasoline/petrol |
10 | BI_METH | Bi-fuel vehicle using methanol |
11 | BI_ETH | Bi-fuel vehicle using ethanol |
12 | BI_LPG | Bi-fuel vehicle using LPG |
13 | BI_CNG | Bi-fuel vehicle using CNG |
14 | BI_PROP | Bi-fuel vehicle using propane |
15 | BI_ELEC | Bi-fuel vehicle using battery |
16 | BI_MIX | Bi-fuel vehicle using battery and combustion engine for propulsion |
17 | HYB_GAS | Hybrid vehicle using gasoline engine for propulsion |
18 | HYB_ETH | Hybrid vehicle using gasoline engine on ethanol for propulsion |
19 | HYB_DSL | Hybrid vehicle using diesel engine for propulsion |
20 | HYB_ELEC | Hybrid vehicle using battery for propulsion |
21 | HYB_MIX | Hybrid vehicle using battery and combustion engine for propulsion |
22 | HYB_REG | Hybrid vehicle in regeneration mode |
23 | BI_DSL | Bi-fuel vehicle using diesel |
24 | BI_NG | Bi-fuel vehicle using natural gas |
25 | BI_DSL | Bi-fuel vehicle using diesel |
26 | NG | Natural gas |
27 | DSL_CNG | Dual fuel vehicle using diesel and CNG |
28 | DSL_LNG | Dual fuel vehicle using diesel and LNG |
29 | FC_H2 | Fuel cell utilizing hydrogen |
30 | HICE_HHO | Hydrogen Internal Combustion Engine |
31 | KERO | Kerosene |
32 | HFO | Heavy Fuel Oil |
Confirmed for 2014. Supported for 2023.
Variable timing control duty HONDA_VARIABLE_TIM_CTRL
- Request
22 26 62 - Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 20 ÷ 51)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2023.
Variable timing control duty HONDA_VTC_DUTYConfirmed
How long the valve is energized versus how long it's not energized, expressed as a percentage. The higher the duty percentage, the more the cam timing is advanced toward its maximum potential.
- Request
22 26 62 - Service 22
DID 2662 - Module
DA10 → 10 - Every
250 ms - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2023. In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014.
Variable timing control duty HONDA_VTC_DUTY_DA11
- Request
22 26 62 - Service 22
DID 2662 - Module
DA11 → 11 - Every
5 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2023.
Variable valve timing duty HONDA_VTC_DUTY_PCM
- Request
22 26 62 - Service 22
DID 2662 - Module
DA0E → 0E - Every
1 s - Testing
Bits 224 to 231 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
VTEC valve control HONDA_VTEC_VALVE_CTRL
VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.
- Request
22 26 12 - Service 22
DID 2612 - Module
DA11 → 11 - Every
1 s - Testing
Bit 175 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 1994, 1996 to 2005, 2007 to 2013, 2015 to 2022, 2024 to 2026. Not supported for 2006, 2014, 2023.
VTEC valve control HONDA_VTEC_VALVE_CTRL_PCM
VTEC works by switching between two (or sometimes three) different camshaft profiles by engaging or disengaging a mechanism that locks the valve rocker arms together. When VTEC is OFF, the engine operates using the standard cam profile, which is typically optimized for fuel efficiency and low-end torque. When VTEC is ON, the system switches to a high-performance cam profile that allows the valves to open wider and for a longer duration, enabling better airflow at higher RPMs for increased power.
- Request
22 26 12 - Service 22
DID 2612 - Module
DA0E → 0E - Every
250 ms - Testing
Bit 175 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 1994, 1996 to 2022, 2024 to 2026. Not supported for 2023.
Engine › OxygenSensors
Lambda value, Equivalence Ratio Bank 1, Sensor 1 LAMBDA11_CURRENTSAE J1979Confirmed
Pelican can show this parameter as the O2 lambda.
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 32768)- Range
- 0 to 1.99
- Unit
- Number
Confirmed for 2023.
Wide Range O2S Current, O2 Sensor Bank 1, Sensor 1 O2S11_CURRENTSAE J1979Confirmed
- Request
01 34 - Service 01
PID 34 - Module
7E0 → 7E8 - Every
250 ms
Bits 16 to 31 of the reply, 16 bits.
- Formula
(val ÷ 256 − 128)- Range
- -128 to 127.996 mA
- Unit
- mA
Confirmed for 2023.