Haval H6 HEV

Engine parameters

The Haval H6 HEV has 44 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Boost pressure HAVAL_BOOST_PRESSURE_VALUEConfirmed

  • Request22 01 6A
  • Service 22DID 016A
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits.

0x2DE0 = 11744 → (11744 ÷ 128) = 91.75 kPa

Formula
(val ÷ 128)
Range
0 to 511.9921875 kPa
Unit
kPa

Confirmed for 2025. In testing for 2021 to 2024, 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Boost pressure HAVAL_BOOST_PRESSURE_VALUEConfirmed

  • Request22 01 6A
  • Service 22DID 016A
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits.

0x2DE0 = 11744 → (11744 ÷ 128) = 91.75 kPa

Formula
(val ÷ 128)
Range
0 to 511.9921875 kPa
Unit
kPa

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Boost pressure, actual HAVAL_BP_ACTUALConfirmed

  • Request22 01 0F
  • Service 22DID 010F
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits.

0x2DE2 = 11746 → (11746 ÷ 128) = 91.765625 kPa

Formula
(val ÷ 128)
Range
0 to 511.9921875 kPa
Unit
kPa

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Boost pressure, target HAVAL_BP_TARGETConfirmed

  • Request22 01 12
  • Service 22DID 0112
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits.

0x2BA5 = 11173 → (11173 ÷ 128) = 87.289063 kPa

Formula
(val ÷ 128)
Range
0 to 511.9921875 kPa
Unit
kPa

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Injection pulse width HAVAL_INJECTION_PULSE_WIDTHConfirmed

  • Request22 01 6D
  • Service 22DID 016D
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 31 of the reply, 32 bits.

0x00000000 = 0 → (0 ÷ 1000) = 0 ms

Formula
(val ÷ 1000)
Range
0 to 4294967.295 ms
Unit
ms

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock counter HAVAL_KNOCK_COUNTER

  • Request22 11 A0
  • Service 22DID 11A0
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2024, 2026. Not supported for 2025.

Knock retard HAVAL_KNOCK_RETARD

  • Request22 11 A6
  • Service 22DID 11A6
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 8.82 ÷ 100)
Range
0 to 22.491 °
Unit
°

In testing for 2021 to 2024, 2026. Not supported for 2025.

Knock retard cylinder 1 HAVAL_INJECTION_KNOCK_RETARD_CYL_1Confirmed

  • Request22 01 70
  • Service 22DID 0170
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 × 0.75) = 0 °

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock retard cylinder 2 HAVAL_INJECTION_KNOCK_RETARD_CYL_2Confirmed

  • Request22 01 71
  • Service 22DID 0171
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 × 0.75) = 0 °

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock retard cylinder 3 HAVAL_INJECTION_KNOCK_RETARD_CYL_3Confirmed

  • Request22 01 72
  • Service 22DID 0172
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 × 0.75) = 0 °

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock retard cylinder 4 HAVAL_INJECTION_KNOCK_RETARD_CYL_4Confirmed

  • Request22 01 73
  • Service 22DID 0173
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 × 0.75) = 0 °

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock retard, cylinder 1 HAVAL_KNOCK_RETARD_CYL_1Confirmed

  • Request22 01 70
  • Service 22DID 0170
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 × 3 ÷ 4) = 0 °

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock retard, cylinder 2 HAVAL_KNOCK_RETARD_CYL_2Confirmed

  • Request22 01 71
  • Service 22DID 0171
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 × 3 ÷ 4) = 0 °

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock retard, cylinder 3 HAVAL_KNOCK_RETARD_CYL_3Confirmed

  • Request22 01 72
  • Service 22DID 0172
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 × 3 ÷ 4) = 0 °

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock retard, cylinder 4 HAVAL_KNOCK_RETARD_CYL_4Confirmed

  • Request22 01 73
  • Service 22DID 0173
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 7 of the reply, 8 bits. The value is signed.

0x00 = 0 → (0 × 3 ÷ 4) = 0 °

Formula
(val × 3 ÷ 4)
Range
-96 to 95.25 °
Unit
°

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock sensor reference voltage cylinder 1 HAVAL_KNOCK_SENSOR_REFERENCE_CYL_1Confirmed

  • Request22 01 74
  • Service 22DID 0174
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.00007625)
Range
0 to 4.99704375 V
Unit
V

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock sensor reference voltage cylinder 2 HAVAL_KNOCK_SENSOR_REFERENCE_CYL_2Confirmed

  • Request22 01 75
  • Service 22DID 0175
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.00007625)
Range
0 to 4.99704375 V
Unit
V

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock sensor reference voltage cylinder 3 HAVAL_KNOCK_SENSOR_REFERENCE_CYL_3Confirmed

  • Request22 01 76
  • Service 22DID 0176
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.00007625)
Range
0 to 4.99704375 V
Unit
V

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock sensor reference voltage cylinder 4 HAVAL_KNOCK_SENSOR_REFERENCE_CYL_4Confirmed

  • Request22 01 77
  • Service 22DID 0177
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.00007625)
Range
0 to 4.99704375 V
Unit
V

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock sensor voltage, cylinder 1 HAVAL_KNOCK_SENSOR_VOLTAGE_CYL_1Confirmed

  • Request22 01 74
  • Service 22DID 0174
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits.

0x0061 = 97 → (97 × 5 ÷ 65535) = 0.007401 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock sensor voltage, cylinder 2 HAVAL_KNOCK_SENSOR_VOLTAGE_CYL_2Confirmed

  • Request22 01 75
  • Service 22DID 0175
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock sensor voltage, cylinder 3 HAVAL_KNOCK_SENSOR_VOLTAGE_CYL_3Confirmed

  • Request22 01 76
  • Service 22DID 0176
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Knock sensor voltage, cylinder 4 HAVAL_KNOCK_SENSOR_VOLTAGE_CYL_4Confirmed

  • Request22 01 77
  • Service 22DID 0177
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits.

0x0061 = 97 → (97 × 5 ÷ 65535) = 0.007401 V

Formula
(val × 5 ÷ 65535)
Range
0 to 5 V
Unit
V

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Misfire current, total HAVAL_MISFIRE_CURRENT_TOTAL

  • Request22 12 00
  • Service 22DID 1200
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 256)
Range
0 to 65280
Unit
Number

In testing for 2021 to 2024, 2026. Not supported for 2025.

Oil pressure HAVAL_OIL_PRESSURE

  • Request22 FD 19
  • Service 22DID FD19
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 156.25 ÷ 10000)
Range
0 to 1023.984375 kPa
Unit
kPa

In testing for 2021 to 2024, 2026. Not supported for 2025.

Oil temperature HAVAL_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request22 16 02
  • Service 22DID 1602
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2024, 2026. Not supported for 2025.

Oil temperature, model HAVAL_OIL_TConfirmed

  • Request22 01 07
  • Service 22DID 0107
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits.

0x2FEE = 12270 → (12270 ÷ 10 − 273.15) = 953.85 °C

Formula
(val ÷ 10 − 273.15)
Range
-273.15 to 6280.35 °C
Unit
°C

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Turbocharger inlet pressure, model HAVAL_PRESSURE_BEFORE_TURBOCHARGERConfirmed

  • Request22 01 13
  • Service 22DID 0113
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits.

0x2DF0 = 11760 → (11760 ÷ 128) = 91.875 kPa

Formula
(val ÷ 128)
Range
0 to 511.9921875 kPa
Unit
kPa

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Turbocharger inlet temperature, model HAVAL_AIR_T_BEFORE_TURBOCHARGERConfirmed

  • Request22 01 14
  • Service 22DID 0114
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits.

0x702E = 28718 → (28718 × 0.023437 − 273.15) = 399.913766 °C

Formula
(val × 0.023437 − 273.15)
Range
-273.15 to 1262.793795 °C
Unit
°C

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Valve timing opening, intake, actual HAVAL_INTAKE_VVT_ACTUALConfirmed

  • Request22 01 52
  • Service 22DID 0152
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x00F2 = 242 → (242 × 156 ÷ 10000) = 3.7752 °

Formula
(val × 156 ÷ 10000)
Range
-511.1808 to 511.1652 °
Unit
°

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Valve timing opening, intake, target HAVAL_INTAKE_VVT_TARGETConfirmed

  • Request22 01 54
  • Service 22DID 0154
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0252 = 594 → (594 × 78 ÷ 10000) = 4.6332 °

Formula
(val × 78 ÷ 10000)
Range
-255.5 to 255.5 °
Unit
°

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Variable clutch pressure control, min oil temperature HAVAL_OT_VCPC_MIN

  • Request22 16 03
  • Service 22DID 1603
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2021 to 2024, 2026. Not supported for 2025.

Engine › Misfires

Misfire current cylinder 1 HAVAL_MISFIRE_CURRENT_CYL_1

  • Request22 12 06
  • Service 22DID 1206
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2024, 2026. Not supported for 2025.

Misfire current cylinder 2 HAVAL_MISFIRE_CURRENT_CYL_2

  • Request22 12 05
  • Service 22DID 1205
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2024, 2026. Not supported for 2025.

Misfire current cylinder 3 HAVAL_MISFIRE_CURRENT_CYL_3

  • Request22 12 07
  • Service 22DID 1207
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2024, 2026. Not supported for 2025.

Misfire current cylinder 4 HAVAL_MISFIRE_CURRENT_CYL_4

  • Request22 12 08
  • Service 22DID 1208
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2021 to 2024, 2026. Not supported for 2025.

Misfire history cylinder 1 HAVAL_MISFIRE_HISTORY_CYL_1

  • Request22 12 01
  • Service 22DID 1201
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2024, 2026. Not supported for 2025.

Misfire history cylinder 2 HAVAL_MISFIRE_HISTORY_CYL_2

  • Request22 12 02
  • Service 22DID 1202
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2024, 2026. Not supported for 2025.

Misfire history cylinder 3 HAVAL_MISFIRE_HISTORY_CYL_3

  • Request22 12 03
  • Service 22DID 1203
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2024, 2026. Not supported for 2025.

Misfire history cylinder 4 HAVAL_MISFIRE_HISTORY_CYL_4

  • Request22 12 04
  • Service 22DID 1204
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2021 to 2024, 2026. Not supported for 2025.

Misfires cylinder 1 HAVAL_MISFIRES_CYL_1Confirmed

  • Request22 01 80
  • Service 22DID 0180
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Misfires cylinder 2 HAVAL_MISFIRES_CYL_2Confirmed

  • Request22 01 83
  • Service 22DID 0183
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Misfires cylinder 3 HAVAL_MISFIRES_CYL_3Confirmed

  • Request22 01 81
  • Service 22DID 0181
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Misfires cylinder 4 HAVAL_MISFIRES_CYL_4Confirmed

  • Request22 01 82
  • Service 22DID 0182
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Misfires total HAVAL_MISFIRES_TOTALConfirmed

  • Request22 01 7F
  • Service 22DID 017F
  • Module7E0
  • Every1 s
  • Testing

Example reply from a 2025 Haval H6 HEV.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2025. In testing for 2021 to 2024, 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.