Connectable parameters
The Haval H6 HEV has 13 Connectables, parameters that Pelican can monitor automatically.
● Confirmed◆ In testing○ Supported× Not supported
State of charge
State of charge HAVAL_BMS_BATT_SOCConfirmed
Pelican can show this parameter as the state of charge.
- Request
22 E0 F4 - Service 22
DID E0F4 - Module
78B → 7CB - Every
1 s - Testing
Example reply from a 2025 Haval H6 HEV.
Bits 0 to 15 of the reply, 16 bits.
0x01AF = 431 → (431 ÷ 10) = 43.1 %
- Formula
(val ÷ 10)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2021 to 2024, 2026.
State of health
State of health HAVAL_BMS_PACK_SOHConfirmed
Pelican can show this parameter as the state of health.
- Request
22 E0 F5 - Service 22
DID E0F5 - Module
78B → 7CB - Every
1 s - Testing
Example reply from a 2025 Haval H6 HEV.
Bits 0 to 7 of the reply, 8 bits.
0x62 = 98 → 98 %
- Formula
val- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2025. In testing for 2021 to 2024, 2026.
Fuel tank level
Fuel level HAVAL_FUEL_LEVEL_INPUT
Pelican can show this parameter as the fuel tank level.
- Request
22 00 2F - Service 22
DID 002F - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2024, 2026. Not supported for 2025.
Fuel level, liters HAVAL_FUEL_LEVEL_LITERSConfirmed
Pelican can show this parameter as the fuel tank level.
- Request
22 01 06 - Service 22
DID 0106 - Module
7E0 - Every
1 s - Testing
Example reply from a 2025 Haval H6 HEV.
Bits 0 to 15 of the reply, 16 bits.
0x01CC = 460 → (460 ÷ 10) = 46 L
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 L
- Unit
- L
Confirmed for 2025. In testing for 2021 to 2024, 2026.
Fuel level, output HAVAL_FUEL_LEVEL_OUTPUT
Pelican can show this parameter as the fuel tank level.
- Request
22 12 C5 - Service 22
DID 12C5 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2021 to 2024, 2026. Not supported for 2025.
Odometer
Odometer, engine HAVAL_ODO_ENG
Pelican can show this parameter as the odometer.
- Request
22 12 1E - Service 22
DID 121E - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 km
- Unit
- km
In testing for 2021 to 2024, 2026. Not supported for 2025.
Transmission odometer HAVAL_ODO_TRANS
Pelican can show this parameter as the odometer.
- Request
22 69 01 - Service 22
DID 6901 - Module
7E1 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 10)- Range
- 0 to 655350 km
- Unit
- km
In testing for 2021 to 2024, 2026. Not supported for 2025.
Vehicle odometer HAVAL_ODO
Pelican can show this parameter as the odometer.
- Request
22 00 A6 - Service 22
DID 00A6 - Module
7E0 - Every
1 s - Testing
Bits 0 to 31 of the reply, 32 bits.
- Formula
val- Range
- 0 to 4294967295 km
- Unit
- km
In testing for 2021 to 2024, 2026. Not supported for 2025.
Engine oil temperature
Oil temperature HAVAL_EOT
Pelican can show this parameter as the engine oil temperature.
- Request
22 16 02 - Service 22
DID 1602 - Module
7E0 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2021 to 2024, 2026. Not supported for 2025.
Traction battery capacity
State of energy HAVAL_BMS_PACK_SOEConfirmed
Pelican can show this parameter as the traction battery capacity.
- Request
22 E0 F6 - Service 22
DID E0F6 - Module
78B → 7CB - Every
1 s - Testing
Example reply from a 2025 Haval H6 HEV.
Bits 0 to 15 of the reply, 16 bits.
0x0004 = 4 → (4 ÷ 10) = 0.4 kWh
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 kWh
- Unit
- kWh
Confirmed for 2025. In testing for 2021 to 2024, 2026.
Traction battery voltage
HV battery voltage HAVAL_BMS_PACK_VOLTAGEConfirmed
Pelican can show this parameter as the traction battery voltage.
- Request
22 E0 06 - Service 22
DID E006 - Module
78B → 7CB - Every
1 s - Testing
Example reply from a 2025 Haval H6 HEV.
Bits 0 to 15 of the reply, 16 bits.
0x0D07 = 3335 → (3335 ÷ 10) = 333.5 V
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 V
- Unit
- V
Confirmed for 2025. In testing for 2021 to 2024, 2026.
Transmission fluid temperature
Transmission fluid temperature HAVAL_TFT
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 D1 26 - Service 22
DID D126 - Module
7E1 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 60)- Range
- -60 to 195 °C
- Unit
- °C
In testing for 2021 to 2024, 2026. Not supported for 2025.
Transmission temperature, pan HAVAL_TFT_PAN
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 6A 0A - Service 22
DID 6A0A - Module
7E1 - Every
1 s - Testing
Bits 8 to 23 of the reply, 16 bits.
- Formula
(val − 55)- Range
- -55 to 65480 °C
- Unit
- °C
In testing for 2021 to 2024, 2026. Not supported for 2025.