Engine parameters
The Genesis G80 has 213 engine parameters.
● Confirmed◆ In testing○ Supported× Not supported
4WD clutch duty G80_AWD_CLU_DUTY
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 72 to 87 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10)- Range
- -3276.8 to 100 %
- Unit
- %
In testing for 2016 to 2026.
4WD clutch pressure G80_AWD_CLU_P
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 216 to 231 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.001953)- Range
- -63.99 to 63.99 bar
- Unit
- bar
In testing for 2016 to 2026.
4WD clutch stress G80_AWD_CLU_STRESS
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 104 to 119 of the reply, 16 bits. The value is signed.
- Formula
(val × 0.001953)- Range
- -63.99 to 63.99 %
- Unit
- %
In testing for 2016 to 2026.
4WD clutch torque G80_AWD_CLU_TQ
- Request
22 01 A1 - Service 22
DID 01A1 - Module
740 → 748 - Every
250 ms - Testing
Bits 200 to 215 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 16)- Range
- -2048 to 2047.9375 N·m
- Unit
- N·m
In testing for 2016 to 2026.
4WD front axle ratio G80_AWD_FRONT_AXLE_RAT
- Request
22 01 A3 - Service 22
DID 01A3 - Module
740 → 748 - Every
250 ms - Testing
Bits 56 to 71 of the reply, 16 bits. The value is signed.
- Formula
(val × 2 ÷ 65535)- Range
- -1 to 0.999
- Unit
- Number
In testing for 2016 to 2026.
Adaptation value for lower stop of wastegate actuator G80_ADPT_LO_STOP
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- -5.01 to 5.01 V
- Unit
- V
In testing for 2016 to 2026.
Air conditioning pressure G80_AC_P
- Request
22 E0 14 - Service 22
DID E014 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 3520 ÷ 255)- Range
- 0 to 3520 kPa
- Unit
- kPa
In testing for 2016 to 2026.
Air conditioning relay G80_AC_RELAY
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bit 101 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2026.
Automatic transmission fluid temperature G80_ATF_T_7E1
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Barometric pressure G80_BAROMETRIC_PRESSURE
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 319 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 127.5 kPa
- Unit
- kPa
In testing for 2016 to 2026.
Boost pressure upstream G80_BOOST_P_UP
- Request
22 E0 03 - Service 22
DID E003 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 39 ÷ 500)- Range
- 0 to 5111
- Unit
- Raw value
In testing for 2016 to 2026.
Boost pressure upstream, desired G80_BOOST_P_UP_DES
- Request
22 E0 03 - Service 22
DID E003 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 39 ÷ 500)- Range
- 0 to 5111
- Unit
- Raw value
In testing for 2016 to 2026.
Calculated oil temperature G80_CALC_OIL_T
- Request
22 E0 11 - Service 22
DID E011 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Catalyst damaging misfires total all cylinders G80_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERS
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Catalyst damaging misfires total all cylinders G80_CATDMG_MIS_TOT_ALL
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Catalyst damaging misfires total, cylinder 1 G80_CATALYST_DAMAGING_MISFIRES_TOTAL_C1
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Catalyst damaging misfires total, cylinder 1 G80_CATDMG_MIS_TOT_1
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Catalyst damaging misfires total, cylinder 1 G80_CATDMG_MIS_TOT_1_7E0
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Catalyst damaging misfires total, cylinder 2 G80_CATALYST_DAMAGING_MISFIRES_TOTAL_C2
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Catalyst damaging misfires total, cylinder 2 G80_CATDMG_MIS_TOT_2
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Catalyst damaging misfires total, cylinder 2 G80_CATDMG_MIS_TOT_2_7E0
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Catalyst damaging misfires total, cylinder 3 G80_CATALYST_DAMAGING_MISFIRES_TOTAL_C3
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Catalyst damaging misfires total, cylinder 3 G80_CATDMG_MIS_TOT_3
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Catalyst damaging misfires total, cylinder 3 G80_CATDMG_MIS_TOT_3_7E0
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Catalyst damaging misfires total, cylinder 4 G80_CATALYST_DAMAGING_MISFIRES_TOTAL_C4
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Catalyst damaging misfires total, cylinder 4 G80_CATDMG_MIS_TOT_4
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Catalyst damaging misfires total, cylinder 4 G80_CATDMG_MIS_TOT_4_7E0
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Catalyst damaging misfires total, cylinder 5 G80_CATDMG_MIS_TOT_5
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Catalyst damaging misfires total, cylinder 6 G80_CATDMG_MIS_TOT_6
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Commanded evaporative purge G80_COMMANDED_EVAPORATIVE_PURGE
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val × 0.390625)- Range
- 0 to 99.6 %
- Unit
- %
In testing for 2016 to 2026.
Commanded throttle actuator G80_COMMANDED_THROTTLE_ACTUATOR
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 40 to 47 of the reply, 8 bits.
- Formula
(val × 0.390625)- Range
- 0 to 99.6 %
- Unit
- %
In testing for 2016 to 2026.
Coolant G80_COOLANT_FAN
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2026.
Coolant fan PWM G80_CLT_FAN_PWM
- Request
22 E0 14 - Service 22
DID E014 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2026.
Coolant temperature G80_HVAC_COOLANT_T
- Request
22 01 02 - Service 22
DID 0102 - Module
7B3 → 7BB - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2016 to 2026.
Crankshaft torque G80_CRANK_TQ
- Request
22 ED 05 - Service 22
DID ED05 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val × 600 ÷ 255)- Range
- 0 to 600 N·m
- Unit
- N·m
In testing for 2016 to 2026.
Cylinder 1 injection time, 1st pulse G80_CYL_1_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Cylinder 1 injection time, 2nd pulse G80_CYL_1_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Cylinder 2 injection time, 1st pulse G80_CYL_2_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Cylinder 2 injection time, 2nd pulse G80_CYL_2_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Cylinder 3 injection time, 1st pulse G80_CYL_3_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Cylinder 3 injection time, 2nd pulse G80_CYL_3_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Cylinder 4 injection time, 1st pulse G80_CYL_4_INJ_TIME_1ST
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Cylinder 4 injection time, 2nd pulse G80_CYL_4_INJ_TIME_2ND
- Request
21 23 - Service 21
PID 23 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Diesel particulate filter regeneration count G80_DPF_REGEN_CNT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 440 to 447 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Diesel particulate filter regeneration state G80_DPF_REGEN_ST
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
30 s - Testing
Bit 431 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2016 to 2026.
Direct injection time 1 G80_DI_TIME_1
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 1st pulse, cylinder 1 G80_DI_TIME_1ST_CYL_1
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 1st pulse, cylinder 2 G80_DI_TIME_1ST_CYL_2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 1st pulse, cylinder 3 G80_DI_TIME_1ST_CYL_3
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 1st pulse, cylinder 4 G80_DI_TIME_1ST_CYL_4
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 1st pulse, cylinder 5 G80_CYL5_INJ_TIME_1ST
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 392 to 407 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 1st pulse, cylinder 6 G80_CYL6_INJ_TIME_1ST
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 2 G80_DI_TIME_2
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 2nd pulse, cylinder 1 G80_DI_TIME_2ND_CYL_1
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 2nd pulse, cylinder 2 G80_DI_TIME_2ND_CYL_2
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 2nd pulse, cylinder 3 G80_DI_TIME_2ND_CYL_3
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 2nd pulse, cylinder 4 G80_DI_TIME_2ND_CYL_4
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 2nd pulse, cylinder 5 G80_CYL5_INJ_TIME_2ND
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 2nd pulse, cylinder 6 G80_CYL6_INJ_TIME_2ND
- Request
22 E0 23 - Service 22
DID E023 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 4 ÷ 1000)- Range
- 0 to 262.14 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 3 G80_DI_TIME_3
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 4 G80_DI_TIME_4
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 5 G80_DI_TIME_5
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2016 to 2026.
Direct injection time 6 G80_DI_TIME_6
- Request
21 0B - Service 21
PID 0B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 13107)- Range
- 0 to 500 ms
- Unit
- ms
In testing for 2016 to 2026.
Dual-clutch transmission clutch 1, pressure sensor a G80_DUAL_CLU_TRANS_CLU_1_P
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 192 to 207 of the reply, 16 bits.
- Formula
(val × 19.53 ÷ 10000)- Range
- 0 to 127 bar
- Unit
- bar
In testing for 2016 to 2026.
Dual-clutch transmission clutch 2, pressure sensor b G80_DUAL_CLU_TRANS_CLU_2_P_B
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits.
- Formula
(val × 19.53 ÷ 10000)- Range
- 0 to 127 bar
- Unit
- bar
In testing for 2016 to 2026.
Dual-clutch transmission fluid temperature 1 G80_DUAL_CLU_ATF_T_1
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Dual-clutch transmission fluid temperature 2 G80_DUAL_CLU_ATF_T_2
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 56 to 63 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Dual-clutch transmission line pressure, sensor c G80_DUAL_CLU_TRANS_LINE_P_C
- Request
22 01 A5 - Service 22
DID 01A5 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits.
- Formula
(val × 19.53 ÷ 10000)- Range
- 0 to 127 bar
- Unit
- bar
In testing for 2016 to 2026.
Emission relevant misfires total all cylinders G80_EMIS_MIS_TOT_ALL
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission relevant misfires total all cylinders G80_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERS
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission relevant misfires total, cylinder 1 G80_EMIS_MIS_TOT_1
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission relevant misfires total, cylinder 1 G80_EMIS_MIS_TOT_1_7E0
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission relevant misfires total, cylinder 1 G80_EMISSION_RELEVANT_MISFIRES_TOTAL_C1
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission relevant misfires total, cylinder 2 G80_EMIS_MIS_TOT_2
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission relevant misfires total, cylinder 2 G80_EMIS_MIS_TOT_2_7E0
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 144 to 159 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission relevant misfires total, cylinder 2 G80_EMISSION_RELEVANT_MISFIRES_TOTAL_C2
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission relevant misfires total, cylinder 3 G80_EMIS_MIS_TOT_3
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission relevant misfires total, cylinder 3 G80_EMIS_MIS_TOT_3_7E0
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission relevant misfires total, cylinder 3 G80_EMISSION_RELEVANT_MISFIRES_TOTAL_C3
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission relevant misfires total, cylinder 4 G80_EMIS_MIS_TOT_4
- Request
22 E0 1D - Service 22
DID E01D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission relevant misfires total, cylinder 4 G80_EMIS_MIS_TOT_4_7E0
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission relevant misfires total, cylinder 4 G80_EMISSION_RELEVANT_MISFIRES_TOTAL_C4
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission relevant misfires total, cylinder 5 G80_EMIS_MIS_TOT_5
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission relevant misfires total, cylinder 6 G80_EMIS_MIS_TOT_6
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Engine oil temperature G80_EOT
Pelican can show this parameter as the engine oil temperature.
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val ÷ 1.3333 − 48)- Range
- 0 to 143 °C
- Unit
- °C
In testing for 2016 to 2026.
Engine oil temperature G80_EOT_7E0
Pelican can show this parameter as the engine oil temperature.
- Request
22 ED 07 - Service 22
DID ED07 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 152 to 159 of the reply, 8 bits.
- Formula
(val × 0.7843 − 50)- Range
- -50 to 149.9965 °C
- Unit
- °C
In testing for 2016 to 2026.
Engine oil temperature G80_EOT_V2
Pelican can show this parameter as the engine oil temperature.
- Request
22 ED 02 - Service 22
DID ED02 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val − 4)- Range
- -4 to 251 °C
- Unit
- °C
In testing for 2016 to 2026.
Engine run time, total G80_ENG_RUN_TIME_TOT
- Request
21 0E - Service 21
PID 0E - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 6)- Range
- 0 to 393209.9999 min
- Unit
- min
In testing for 2016 to 2026.
Engine, actual torque G80_ENG_ACT_TQ
- Request
22 ED 01 - Service 22
DID ED01 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 240 to 247 of the reply, 8 bits.
- Formula
(val × 2.3529)- Range
- 0 to 599.9895 N·m
- Unit
- N·m
In testing for 2016 to 2026.
Exhaust camshaft position G80_EXH_CAM_POS
- Request
22 E0 20 - Service 22
DID E020 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
In testing for 2016 to 2026.
Exhaust gas temperature G80_EXHAUST_GAS_T
- Request
21 03 - Service 21
PID 03 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 368 to 375 of the reply, 8 bits.
- Formula
(val × 4.709803922 + 99)- Range
- 99 to 1300 °C
- Unit
- °C
In testing for 2016 to 2026.
Exhaust temperature 1, upstream of oxidation catalyst G80_EXH_T_1_UP_OXICAT
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 296 to 303 of the reply, 8 bits.
- Formula
(val × 4.7098 + 99)- Range
- 0 to 1299.999 °C
- Unit
- °C
In testing for 2016 to 2026.
Exhaust temperature 2, upstream of DPF G80_EXH_T_2_UP_DPF
- Request
22 ED 03 - Service 22
DID ED03 - Module
7E0 → 7E8 - Every
30 s - Testing
Bits 304 to 311 of the reply, 8 bits.
- Formula
(val × 4.7098 + 99)- Range
- 0 to 1299.999 °C
- Unit
- °C
In testing for 2016 to 2026.
Gasoline direct injection time bank a, 1 G80_GDI_IT_A1
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2026.
Gasoline direct injection time bank a, 2 G80_GDI_IT_A2
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2026.
Gasoline direct injection time bank a, 3 G80_GDI_IT_A3
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2026.
Gasoline direct injection time bank a, 4 G80_GDI_IT_A4
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2026.
Gasoline direct injection time bank b, 1 G80_GDI_IT_B1
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2026.
Gasoline direct injection time bank b, 2 G80_GDI_IT_B2
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2026.
Gasoline direct injection time bank b, 3 G80_GDI_IT_B3
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2026.
Gasoline direct injection time bank b, 4 G80_GDI_IT_B4
- Request
22 E0 05 - Service 22
DID E005 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 ms
- Unit
- ms
In testing for 2016 to 2026.
Idle control mode G80_IDLE_CONTROL_MODE
- Request
21 00 - Service 21
PID 00 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Ignition retard due to knock control 1 G80_IGN_RETARD_KNOCK_1
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2026.
Ignition retard due to knock control 2 G80_IGN_RETARD_KNOCK_2
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2026.
Ignition retard due to knock control 3 G80_IGN_RETARD_KNOCK_3
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2026.
Ignition retard due to knock control 4 G80_IGN_RETARD_KNOCK_4
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2026.
Injection duration cylinder 1 G80_INJ_DUR_1
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.68 s
- Unit
- s
In testing for 2016 to 2026.
Injection duration cylinder 2 G80_INJ_DUR_2
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.68 s
- Unit
- s
In testing for 2016 to 2026.
Injection duration cylinder 3 G80_INJ_DUR_3
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.68 s
- Unit
- s
In testing for 2016 to 2026.
Injection duration cylinder 4 G80_INJ_DUR_4
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.68 s
- Unit
- s
In testing for 2016 to 2026.
Injection duration cylinder 5 G80_INJ_DUR_5
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.68 s
- Unit
- s
In testing for 2016 to 2026.
Injection duration cylinder 6 G80_INJ_DUR_6
- Request
22 E0 02 - Service 22
DID E002 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val ÷ 1220.7)- Range
- 0 to 53.68 s
- Unit
- s
In testing for 2016 to 2026.
Intake air temperature G80_IAT
- Request
22 E0 01 - Service 22
DID E001 - Module
7E0 → 7E8 - Every
2 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val ÷ 1.3333 − 48)- Range
- 0 to 143 °C
- Unit
- °C
In testing for 2016 to 2026.
Intake camshaft position G80_INT_CAM_POS
- Request
22 E0 20 - Service 22
DID E020 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
In testing for 2016 to 2026.
Intake camshaft position actual G80_INTAKE_CAMSHAFT_POSITION_ACTUAL
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val ÷ 128)- Range
- -256 to 255 °
- Unit
- °
In testing for 2016 to 2026.
Intake camshaft position commanded G80_INTAKE_CAMSHAFT_POSITION_COMMANDED
- Request
21 17 - Service 21
PID 17 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 2)- Range
- -64 to 63.5 °
- Unit
- °
In testing for 2016 to 2026.
Inverter temperature G80_HVAC_INVERTER_T
- Request
22 01 02 - Service 22
DID 0102 - Module
7B3 → 7BB - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val ÷ 2 − 40)- Range
- -40 to 87.5 °C
- Unit
- °C
In testing for 2016 to 2026.
Knock detected G80_KNOCK_DETECTED
- Request
21 00 - Service 21
PID 00 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 200 to 207 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Knock detected G80_KNOCK_DETECTED_7E0
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Knock learn cylinder 1 G80_KNOCK_LEARN_1
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
In testing for 2016 to 2026.
Knock learn cylinder 2 G80_KNOCK_LEARN_2
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
In testing for 2016 to 2026.
Knock learn cylinder 3 G80_KNOCK_LEARN_3
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
In testing for 2016 to 2026.
Knock learn cylinder 4 G80_KNOCK_LEARN_4
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder #1 G80_KNOCK_RETARD_CYLINDER_1
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder #2 G80_KNOCK_RETARD_CYLINDER_2
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder #3 G80_KNOCK_RETARD_CYLINDER_3
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder #4 G80_KNOCK_RETARD_CYLINDER_4
- Request
21 16 - Service 21
PID 16 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val × 0.75)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 1 G80_KNOCK_RETARD_1
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 1 G80_KNOCK_RETARD_CYL_1
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 1, alternate G80_KNOCK_RETARD_1_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 1, alternate G80_KNOCK_RETARD_CYL_1_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 167 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 2 G80_KNOCK_RETARD_2
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 111 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 2 G80_KNOCK_RETARD_CYL_2
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 2, alternate G80_KNOCK_RETARD_2_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 2, alternate G80_KNOCK_RETARD_CYL_2_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 168 to 175 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 3 G80_KNOCK_RETARD_3
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 112 to 119 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 3 G80_KNOCK_RETARD_CYL_3
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 3, alternate G80_KNOCK_RETARD_3_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 3, alternate G80_KNOCK_RETARD_CYL_3_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 183 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 4 G80_KNOCK_RETARD_4
- Request
22 E0 0A - Service 22
DID E00A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 120 to 127 of the reply, 8 bits. The value is signed.
- Formula
(val ÷ 5)- Range
- -25.6 to 25.4 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 4 G80_KNOCK_RETARD_CYL_4
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 4, alternate G80_KNOCK_RETARD_4_E019
- Request
22 E0 19 - Service 22
DID E019 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 199 of the reply, 8 bits.
- Formula
(val × 0.75 − 191.25)- Range
- -191.25 to 0 °
- Unit
- °
In testing for 2016 to 2026.
Knock retard cylinder 4, alternate G80_KNOCK_RETARD_CYL_4_ALT
- Request
21 0A - Service 21
PID 0A - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 184 to 191 of the reply, 8 bits.
- Formula
(val ÷ 1.333333333)- Range
- 0 to 191.25 °
- Unit
- °
In testing for 2016 to 2026.
Main injection volume G80_MAIN_INJECTION_QTY
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 103 of the reply, 8 bits.
- Formula
(val × 0.392156863)- Range
- 0 to 100 L
- Unit
- L
In testing for 2016 to 2026.
Mass air flow rate G80_MAF_RATE
- Request
22 E0 10 - Service 22
DID E010 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.
- Formula
(val × 0.04239)- Range
- 0 to 10.8
- Unit
- Raw value
In testing for 2016 to 2026.
Max adaptation value for lower mechanical stop of the boost pressure actuator during engine running G80_MAX_ADPT_LO_MECH_STOP_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 480 to 495 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2016 to 2026.
Max adaptation value for lower mechanical stop of the boost pressure actuator during engine stop G80_MAX_ADPT_LO_MECH_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 464 to 479 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2016 to 2026.
Min adaptation value for lower mechanical stop of the boost pressure actuator during engine running G80_MIN_ADPT_LO_MECH_STOP_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 512 to 527 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2016 to 2026.
Min adaptation value for lower mechanical stop of the boost pressure actuator during engine stop G80_MIN_ADPT_LO_MECH_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 496 to 511 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 1.53 ÷ 10000)- Range
- 0 to 10.02 V
- Unit
- V
In testing for 2016 to 2026.
Misfire count #1 G80_MIS_1
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfire count #2 G80_MIS_2
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 72 to 87 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfire count #3 G80_MIS_3
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 88 to 103 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfire count #4 G80_MIS_4
- Request
21 01 - Service 21
PID 01 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires current total G80_MIS_CURRENT_TOT
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 584 to 591 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Misfires current, cylinder 1 G80_MIS_CURRENT_1
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 536 to 543 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Misfires current, cylinder 2 G80_MIS_CURRENT_2
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 544 to 551 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Misfires current, cylinder 3 G80_MIS_CURRENT_3
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 552 to 559 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Misfires current, cylinder 4 G80_MIS_CURRENT_4
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 560 to 567 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Misfires current, cylinder 5 G80_MIS_CURRENT_5
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 568 to 575 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Misfires current, cylinder 6 G80_MIS_CURRENT_6
- Request
21 08 - Service 21
PID 08 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 576 to 583 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Misfires, current, cylinder 1 G80_MISFIRES_C1_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires, current, cylinder 2 G80_MISFIRES_C2_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires, current, cylinder 3 G80_MISFIRES_C3_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires, current, cylinder 4 G80_MISFIRES_C4_CUR
- Request
22 E0 0D - Service 22
DID E00D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Motor-driven power steering current G80_MDPS_MOTOR_CURRENT
- Request
22 01 01 - Service 22
DID 0101 - Module
7D4 → 7DC - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits. The value is signed.
- Formula
val- Range
- -128 to 127 A
- Unit
- A
In testing for 2016 to 2026.
Oxygen sensor 1 bank 1 G80_OXYGEN_SENSOR_11
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits.
- Formula
(val × 0.00521 − 0.2)- Range
- -0.2 to 1.12 V
- Unit
- V
In testing for 2016 to 2026.
Oxygen sensor 2 bank 1 G80_OXYGEN_SENSOR_21
- Request
21 02 - Service 21
PID 02 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits.
- Formula
(val × 0.00521 − 0.2)- Range
- -0.2 to 1.12 V
- Unit
- V
In testing for 2016 to 2026.
Pilot injection volume G80_PILOT_INJECTION_QTY
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 L
- Unit
- L
In testing for 2016 to 2026.
Post injection volume G80_POST_INJECTION_QTY
- Request
21 07 - Service 21
PID 07 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 L
- Unit
- L
In testing for 2016 to 2026.
Requested torque G80_REQUESTED_TORQUE
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 176 to 191 of the reply, 16 bits.
- Formula
(val × 0.001526)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2026.
Requested torque limitation from traction control G80_REQ_TQ_LIM_TRACTION
- Request
22 ED 06 - Service 22
DID ED06 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 120 to 127 of the reply, 8 bits.
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2026.
Throttle position #1 G80_THROTTLE_POSITION__1
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.0244140625)- Range
- -800 to 799 %
- Unit
- %
In testing for 2016 to 2026.
Throttle position #2 G80_THROTTLE_POSITION__2
- Request
21 14 - Service 21
PID 14 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 0.0244140625)- Range
- -800 to 799 %
- Unit
- %
In testing for 2016 to 2026.
Timing advance #1 G80_TIMING_ADVANCE_1
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 39 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2016 to 2026.
Timing advance #2 G80_TIMING_ADVANCE_2
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 40 to 47 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2016 to 2026.
Timing advance #3 G80_TIMING_ADVANCE_3
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 55 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2016 to 2026.
Timing advance #4 G80_TIMING_ADVANCE_4
- Request
21 13 - Service 21
PID 13 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 63 of the reply, 8 bits. The value is signed.
- Formula
(val × 0.75)- Range
- -96 to 95.25 °
- Unit
- °
In testing for 2016 to 2026.
Torque converter slip G80_TORQUE_CONVERTER_SLIP
- Request
22 01 A0 - Service 22
DID 01A0 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 128 to 143 of the reply, 16 bits.
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 rpm
- Unit
- rpm
In testing for 2016 to 2026.
Torque converter slip G80_TQ_CONV_SLIP
- Request
21 A0 - Service 21
PID A0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 104 to 119 of the reply, 16 bits.
- Formula
(val ÷ 4 − 512)- Range
- -512 to 15871.75 rpm
- Unit
- rpm
In testing for 2016 to 2026.
Transmission fluid temperature G80_ATF_T_7E0
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 A0 - Service 21
PID A0 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 264 to 271 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2016 to 2026.
Turbo boost gauge pressure G80_TURBO_BOOST
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
100 ms - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val ÷ 831.556909 − 12)- Range
- -10 to 66.81 psi
- Unit
- psi
In testing for 2016 to 2026.
Turbo boost pressure G80_TURBO_BOOST_P
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
(val × 829.1 ÷ 10000)- Range
- 0 to 5433
- Unit
- Raw value
In testing for 2016 to 2026.
Turbo boost pressure G80_TURBO_BOOST_P_7E0
- Request
21 21 - Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 56 to 71 of the reply, 16 bits.
- Formula
(val × 0.008291)- Range
- 0 to 543
- Unit
- Number
In testing for 2016 to 2026.
Variable valve timing temperature G80_CVVT_T
Continuously variable valve timing temperature.
- Request
21 18 - Service 21
PID 18 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 272 to 279 of the reply, 8 bits.
- Formula
(val − 48)- Range
- -48 to 207 °C
- Unit
- °C
In testing for 2016 to 2026.
Waste gate duty G80_WASTE_GATE_DUTY
- Request
21 21 - Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
(val × 0.00305176)- Range
- 0 to 199 %
- Unit
- %
In testing for 2016 to 2026.
Waste gate duty G80_WG_DUTY
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
100 ms - Testing
Bits 408 to 423 of the reply, 16 bits.
- Formula
(val × 200 ÷ 65535)- Range
- 0 to 200 %
- Unit
- %
In testing for 2016 to 2026.
Waste gate position G80_WASTE_GATE_POS
- Request
21 21 - Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 424 to 439 of the reply, 16 bits.
- Formula
(val × 0.00610352)- Range
- 0 to 399 %
- Unit
- %
In testing for 2016 to 2026.
Waste gate position G80_WG_POSITION
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
100 ms - Testing
Bits 424 to 439 of the reply, 16 bits.
- Formula
(val × 400 ÷ 65535)- Range
- 0 to 400 %
- Unit
- %
In testing for 2016 to 2026.
Waste gate set point G80_WG_SETPOINT
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
100 ms - Testing
Bits 440 to 455 of the reply, 16 bits.
- Formula
(val × 400 ÷ 65535)- Range
- 0 to 100 %
- Unit
- %
In testing for 2016 to 2026.
Waste gate target G80_WASTE_GATE_TGT
- Request
21 21 - Service 21
PID 21 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 440 to 455 of the reply, 16 bits.
- Formula
(val × 0.00610352)- Range
- 0 to 399 %
- Unit
- %
In testing for 2016 to 2026.
Waste gate voltage G80_WG_VOLTAGE
- Request
22 E0 21 - Service 22
DID E021 - Module
7E0 → 7E8 - Every
100 ms - Testing
Bits 392 to 407 of the reply, 16 bits.
- Formula
(val × 10 ÷ 65535)- Range
- 0 to 10 V
- Unit
- V
In testing for 2016 to 2026.
Wastegate control PWM, wastegate actuator G80_WASTEGATE_CTRL_PWM
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 416 to 431 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 100 ÷ 32767)- Range
- -100 to 100 %
- Unit
- %
In testing for 2016 to 2026.
Wastegate position target, wastegate actuator G80_WASTEGATE_POS_TGT
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 200 ÷ 32767)- Range
- -200 to 200 %
- Unit
- %
In testing for 2016 to 2026.
Wastegate position, wastegate actuator G80_WASTEGATE_POS
- Request
21 19 - Service 21
PID 19 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.
- Formula
(val × 200 ÷ 32767)- Range
- -200 to 200 %
- Unit
- %
In testing for 2016 to 2026.
Wide open throttle G80_WIDE_OPEN_THROTTLE
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 72 to 79 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2016 to 2026.
Engine › Misfires
Emission-relevant misfires, cylinder #1 G80_MIS_CNT_EMIS_1
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission-relevant misfires, cylinder #2 G80_MIS_CNT_EMIS_2
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission-relevant misfires, cylinder #3 G80_MIS_CNT_EMIS_3
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Emission-relevant misfires, cylinder #4 G80_MIS_CNT_EMIS_4
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires harmful for catalyst cylinder 1 G80_MIS_CAT_1
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires harmful for catalyst cylinder 2 G80_MIS_CAT_2
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires harmful for catalyst cylinder 3 G80_MIS_CAT_3
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires harmful for catalyst cylinder 4 G80_MIS_CAT_4
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires total counter, all cylinders G80_MIS_CNT_ALL
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires total counter, cylinder #1 G80_MIS_CNT_1
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires total counter, cylinder #2 G80_MIS_CNT_2
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires total counter, cylinder #3 G80_MIS_CNT_3
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires total counter, cylinder #4 G80_MIS_CNT_4
- Request
21 0D - Service 21
PID 0D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires, cylinder 1 G80_MIS_1_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires, cylinder 2 G80_MIS_2_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires, cylinder 3 G80_MIS_3_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Misfires, cylinder 4 G80_MIS_4_7E0
- Request
21 1D - Service 21
PID 1D - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.
- Formula
val- Range
- 0 to 65535
- Unit
- Number
In testing for 2016 to 2026.
Engine › Unknown
Engine status byte G80_E004_BYTE0
- Request
22 E0 04 - Service 22
DID E004 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100
- Unit
- Number
In testing for 2016 to 2026.