Genesis G80

Engine parameters

The Genesis G80 has 213 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

4WD clutch duty G80_AWD_CLU_DUTY

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 100 %
Unit
%

In testing for 2016 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

4WD clutch duty G80_AWD_CLU_DUTY

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276.8 to 100 %
Unit
%

In testing for 2016 to 2026.

4WD clutch pressure G80_AWD_CLU_P

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 216 to 231 of the reply, 16 bits. The value is signed.

Formula
(val × 0.001953)
Range
-63.99 to 63.99 bar
Unit
bar

In testing for 2016 to 2026.

4WD clutch stress G80_AWD_CLU_STRESS

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 104 to 119 of the reply, 16 bits. The value is signed.

Formula
(val × 0.001953)
Range
-63.99 to 63.99 %
Unit
%

In testing for 2016 to 2026.

4WD clutch torque G80_AWD_CLU_TQ

  • Request22 01 A1
  • Service 22DID 01A1
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 200 to 215 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 16)
Range
-2048 to 2047.9375 N·m
Unit
N·m

In testing for 2016 to 2026.

4WD front axle ratio G80_AWD_FRONT_AXLE_RAT

  • Request22 01 A3
  • Service 22DID 01A3
  • Module740 → 748
  • Every250 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits. The value is signed.

Formula
(val × 2 ÷ 65535)
Range
-1 to 0.999
Unit
Number

In testing for 2016 to 2026.

Adaptation value for lower stop of wastegate actuator G80_ADPT_LO_STOP

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
-5.01 to 5.01 V
Unit
V

In testing for 2016 to 2026.

Air conditioning pressure G80_AC_P

  • Request22 E0 14
  • Service 22DID E014
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 3520 ÷ 255)
Range
0 to 3520 kPa
Unit
kPa

In testing for 2016 to 2026.

Air conditioning relay G80_AC_RELAY

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bit 101 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Automatic transmission fluid temperature G80_ATF_T_7E1

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2026.

Barometric pressure G80_BAROMETRIC_PRESSURE

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 319 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127.5 kPa
Unit
kPa

In testing for 2016 to 2026.

Boost pressure upstream G80_BOOST_P_UP

  • Request22 E0 03
  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 39 ÷ 500)
Range
0 to 5111
Unit
Raw value

In testing for 2016 to 2026.

Boost pressure upstream, desired G80_BOOST_P_UP_DES

  • Request22 E0 03
  • Service 22DID E003
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 39 ÷ 500)
Range
0 to 5111
Unit
Raw value

In testing for 2016 to 2026.

Calculated oil temperature G80_CALC_OIL_T

  • Request22 E0 11
  • Service 22DID E011
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2026.

Catalyst damaging misfires total all cylinders G80_CATALYST_DAMAGING_MISFIRES_TOTAL_ALL_CYLINDERS

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Catalyst damaging misfires total all cylinders G80_CATDMG_MIS_TOT_ALL

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Catalyst damaging misfires total, cylinder 1 G80_CATALYST_DAMAGING_MISFIRES_TOTAL_C1

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Catalyst damaging misfires total, cylinder 1 G80_CATDMG_MIS_TOT_1

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Catalyst damaging misfires total, cylinder 1 G80_CATDMG_MIS_TOT_1_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Catalyst damaging misfires total, cylinder 2 G80_CATALYST_DAMAGING_MISFIRES_TOTAL_C2

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Catalyst damaging misfires total, cylinder 2 G80_CATDMG_MIS_TOT_2

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Catalyst damaging misfires total, cylinder 2 G80_CATDMG_MIS_TOT_2_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Catalyst damaging misfires total, cylinder 3 G80_CATALYST_DAMAGING_MISFIRES_TOTAL_C3

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Catalyst damaging misfires total, cylinder 3 G80_CATDMG_MIS_TOT_3

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Catalyst damaging misfires total, cylinder 3 G80_CATDMG_MIS_TOT_3_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 288 to 303 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Catalyst damaging misfires total, cylinder 4 G80_CATALYST_DAMAGING_MISFIRES_TOTAL_C4

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Catalyst damaging misfires total, cylinder 4 G80_CATDMG_MIS_TOT_4

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Catalyst damaging misfires total, cylinder 4 G80_CATDMG_MIS_TOT_4_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 304 to 319 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Catalyst damaging misfires total, cylinder 5 G80_CATDMG_MIS_TOT_5

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 320 to 335 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Catalyst damaging misfires total, cylinder 6 G80_CATDMG_MIS_TOT_6

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 336 to 351 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Commanded evaporative purge G80_COMMANDED_EVAPORATIVE_PURGE

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
(val × 0.390625)
Range
0 to 99.6 %
Unit
%

In testing for 2016 to 2026.

Commanded throttle actuator G80_COMMANDED_THROTTLE_ACTUATOR

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val × 0.390625)
Range
0 to 99.6 %
Unit
%

In testing for 2016 to 2026.

Coolant G80_COOLANT_FAN

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2016 to 2026.

Coolant fan PWM G80_CLT_FAN_PWM

  • Request22 E0 14
  • Service 22DID E014
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2026.

Coolant temperature G80_HVAC_COOLANT_T

  • Request22 01 02
  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2016 to 2026.

Crankshaft torque G80_CRANK_TQ

  • Request22 ED 05
  • Service 22DID ED05
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
(val × 600 ÷ 255)
Range
0 to 600 N·m
Unit
N·m

In testing for 2016 to 2026.

Cylinder 1 injection time, 1st pulse G80_CYL_1_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Cylinder 1 injection time, 2nd pulse G80_CYL_1_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Cylinder 2 injection time, 1st pulse G80_CYL_2_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Cylinder 2 injection time, 2nd pulse G80_CYL_2_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Cylinder 3 injection time, 1st pulse G80_CYL_3_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Cylinder 3 injection time, 2nd pulse G80_CYL_3_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Cylinder 4 injection time, 1st pulse G80_CYL_4_INJ_TIME_1ST

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Cylinder 4 injection time, 2nd pulse G80_CYL_4_INJ_TIME_2ND

  • Request21 23
  • Service 21PID 23
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Diesel particulate filter regeneration count G80_DPF_REGEN_CNT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 440 to 447 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Diesel particulate filter regeneration state G80_DPF_REGEN_ST

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bit 431 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 2016 to 2026.

Direct injection time 1 G80_DI_TIME_1

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 1st pulse, cylinder 1 G80_DI_TIME_1ST_CYL_1

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 264 to 279 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 1st pulse, cylinder 2 G80_DI_TIME_1ST_CYL_2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 280 to 295 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 1st pulse, cylinder 3 G80_DI_TIME_1ST_CYL_3

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 296 to 311 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 1st pulse, cylinder 4 G80_DI_TIME_1ST_CYL_4

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 312 to 327 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 1st pulse, cylinder 5 G80_CYL5_INJ_TIME_1ST

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 392 to 407 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 1st pulse, cylinder 6 G80_CYL6_INJ_TIME_1ST

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 2 G80_DI_TIME_2

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 2nd pulse, cylinder 1 G80_DI_TIME_2ND_CYL_1

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 215 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 2nd pulse, cylinder 2 G80_DI_TIME_2ND_CYL_2

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 216 to 231 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 2nd pulse, cylinder 3 G80_DI_TIME_2ND_CYL_3

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 232 to 247 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 2nd pulse, cylinder 4 G80_DI_TIME_2ND_CYL_4

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 248 to 263 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 2nd pulse, cylinder 5 G80_CYL5_INJ_TIME_2ND

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 360 to 375 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 2nd pulse, cylinder 6 G80_CYL6_INJ_TIME_2ND

  • Request22 E0 23
  • Service 22DID E023
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 376 to 391 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 4 ÷ 1000)
Range
0 to 262.14 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 3 G80_DI_TIME_3

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 4 G80_DI_TIME_4

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 5 G80_DI_TIME_5

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2016 to 2026.

Direct injection time 6 G80_DI_TIME_6

  • Request21 0B
  • Service 21PID 0B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 127 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 100 ÷ 13107)
Range
0 to 500 ms
Unit
ms

In testing for 2016 to 2026.

Dual-clutch transmission clutch 1, pressure sensor a G80_DUAL_CLU_TRANS_CLU_1_P

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits.

Formula
(val × 19.53 ÷ 10000)
Range
0 to 127 bar
Unit
bar

In testing for 2016 to 2026.

Dual-clutch transmission clutch 2, pressure sensor b G80_DUAL_CLU_TRANS_CLU_2_P_B

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits.

Formula
(val × 19.53 ÷ 10000)
Range
0 to 127 bar
Unit
bar

In testing for 2016 to 2026.

Dual-clutch transmission fluid temperature 1 G80_DUAL_CLU_ATF_T_1

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2026.

Dual-clutch transmission fluid temperature 2 G80_DUAL_CLU_ATF_T_2

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2026.

Dual-clutch transmission line pressure, sensor c G80_DUAL_CLU_TRANS_LINE_P_C

  • Request22 01 A5
  • Service 22DID 01A5
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits.

Formula
(val × 19.53 ÷ 10000)
Range
0 to 127 bar
Unit
bar

In testing for 2016 to 2026.

Emission relevant misfires total all cylinders G80_EMIS_MIS_TOT_ALL

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission relevant misfires total all cylinders G80_EMISSION_RELEVANT_MISFIRES_TOTAL_ALL_CYLINDERS

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission relevant misfires total, cylinder 1 G80_EMIS_MIS_TOT_1

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission relevant misfires total, cylinder 1 G80_EMIS_MIS_TOT_1_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission relevant misfires total, cylinder 1 G80_EMISSION_RELEVANT_MISFIRES_TOTAL_C1

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission relevant misfires total, cylinder 2 G80_EMIS_MIS_TOT_2

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission relevant misfires total, cylinder 2 G80_EMIS_MIS_TOT_2_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 144 to 159 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission relevant misfires total, cylinder 2 G80_EMISSION_RELEVANT_MISFIRES_TOTAL_C2

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission relevant misfires total, cylinder 3 G80_EMIS_MIS_TOT_3

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission relevant misfires total, cylinder 3 G80_EMIS_MIS_TOT_3_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission relevant misfires total, cylinder 3 G80_EMISSION_RELEVANT_MISFIRES_TOTAL_C3

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission relevant misfires total, cylinder 4 G80_EMIS_MIS_TOT_4

  • Request22 E0 1D
  • Service 22DID E01D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission relevant misfires total, cylinder 4 G80_EMIS_MIS_TOT_4_7E0

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission relevant misfires total, cylinder 4 G80_EMISSION_RELEVANT_MISFIRES_TOTAL_C4

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission relevant misfires total, cylinder 5 G80_EMIS_MIS_TOT_5

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission relevant misfires total, cylinder 6 G80_EMIS_MIS_TOT_6

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Engine oil temperature G80_EOT

Pelican can show this parameter as the engine oil temperature.

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val ÷ 1.3333 − 48)
Range
0 to 143 °C
Unit
°C

In testing for 2016 to 2026.

Engine oil temperature G80_EOT_7E0

Pelican can show this parameter as the engine oil temperature.

  • Request22 ED 07
  • Service 22DID ED07
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 152 to 159 of the reply, 8 bits.

Formula
(val × 0.7843 − 50)
Range
-50 to 149.9965 °C
Unit
°C

In testing for 2016 to 2026.

Engine oil temperature G80_EOT_V2

Pelican can show this parameter as the engine oil temperature.

  • Request22 ED 02
  • Service 22DID ED02
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val − 4)
Range
-4 to 251 °C
Unit
°C

In testing for 2016 to 2026.

Engine run time, total G80_ENG_RUN_TIME_TOT

  • Request21 0E
  • Service 21PID 0E
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 6)
Range
0 to 393209.9999 min
Unit
min

In testing for 2016 to 2026.

Engine, actual torque G80_ENG_ACT_TQ

  • Request22 ED 01
  • Service 22DID ED01
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 240 to 247 of the reply, 8 bits.

Formula
(val × 2.3529)
Range
0 to 599.9895 N·m
Unit
N·m

In testing for 2016 to 2026.

Exhaust camshaft position G80_EXH_CAM_POS

  • Request22 E0 20
  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
-256 to 255 °
Unit
°

In testing for 2016 to 2026.

Exhaust gas temperature G80_EXHAUST_GAS_T

  • Request21 03
  • Service 21PID 03
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 368 to 375 of the reply, 8 bits.

Formula
(val × 4.709803922 + 99)
Range
99 to 1300 °C
Unit
°C

In testing for 2016 to 2026.

Exhaust temperature 1, upstream of oxidation catalyst G80_EXH_T_1_UP_OXICAT

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 296 to 303 of the reply, 8 bits.

Formula
(val × 4.7098 + 99)
Range
0 to 1299.999 °C
Unit
°C

In testing for 2016 to 2026.

Exhaust temperature 2, upstream of DPF G80_EXH_T_2_UP_DPF

  • Request22 ED 03
  • Service 22DID ED03
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 304 to 311 of the reply, 8 bits.

Formula
(val × 4.7098 + 99)
Range
0 to 1299.999 °C
Unit
°C

In testing for 2016 to 2026.

Gasoline direct injection time bank a, 1 G80_GDI_IT_A1

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2026.

Gasoline direct injection time bank a, 2 G80_GDI_IT_A2

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2026.

Gasoline direct injection time bank a, 3 G80_GDI_IT_A3

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2026.

Gasoline direct injection time bank a, 4 G80_GDI_IT_A4

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 272 to 287 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2026.

Gasoline direct injection time bank b, 1 G80_GDI_IT_B1

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 352 to 367 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2026.

Gasoline direct injection time bank b, 2 G80_GDI_IT_B2

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 368 to 383 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2026.

Gasoline direct injection time bank b, 3 G80_GDI_IT_B3

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 384 to 399 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2026.

Gasoline direct injection time bank b, 4 G80_GDI_IT_B4

  • Request22 E0 05
  • Service 22DID E005
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 400 to 415 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 10)
Range
0 to 6553.5 ms
Unit
ms

In testing for 2016 to 2026.

Idle control mode G80_IDLE_CONTROL_MODE

  • Request21 00
  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Ignition retard due to knock control 1 G80_IGN_RETARD_KNOCK_1

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2026.

Ignition retard due to knock control 2 G80_IGN_RETARD_KNOCK_2

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2026.

Ignition retard due to knock control 3 G80_IGN_RETARD_KNOCK_3

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2026.

Ignition retard due to knock control 4 G80_IGN_RETARD_KNOCK_4

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 135 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2026.

Injection duration cylinder 1 G80_INJ_DUR_1

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

In testing for 2016 to 2026.

Injection duration cylinder 2 G80_INJ_DUR_2

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

In testing for 2016 to 2026.

Injection duration cylinder 3 G80_INJ_DUR_3

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

In testing for 2016 to 2026.

Injection duration cylinder 4 G80_INJ_DUR_4

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

In testing for 2016 to 2026.

Injection duration cylinder 5 G80_INJ_DUR_5

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 240 to 255 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

In testing for 2016 to 2026.

Injection duration cylinder 6 G80_INJ_DUR_6

  • Request22 E0 02
  • Service 22DID E002
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 256 to 271 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val ÷ 1220.7)
Range
0 to 53.68 s
Unit
s

In testing for 2016 to 2026.

Intake air temperature G80_IAT

  • Request22 E0 01
  • Service 22DID E001
  • Module7E0 → 7E8
  • Every2 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
(val ÷ 1.3333 − 48)
Range
0 to 143 °C
Unit
°C

In testing for 2016 to 2026.

Intake camshaft position G80_INT_CAM_POS

  • Request22 E0 20
  • Service 22DID E020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
-256 to 255 °
Unit
°

In testing for 2016 to 2026.

Intake camshaft position actual G80_INTAKE_CAMSHAFT_POSITION_ACTUAL

  • Request21 17
  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 55 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val ÷ 128)
Range
-256 to 255 °
Unit
°

In testing for 2016 to 2026.

Intake camshaft position commanded G80_INTAKE_CAMSHAFT_POSITION_COMMANDED

  • Request21 17
  • Service 21PID 17
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 2)
Range
-64 to 63.5 °
Unit
°

In testing for 2016 to 2026.

Inverter temperature G80_HVAC_INVERTER_T

  • Request22 01 02
  • Service 22DID 0102
  • Module7B3 → 7BB
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2016 to 2026.

Knock detected G80_KNOCK_DETECTED

  • Request21 00
  • Service 21PID 00
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Knock detected G80_KNOCK_DETECTED_7E0

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Knock learn cylinder 1 G80_KNOCK_LEARN_1

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2016 to 2026.

Knock learn cylinder 2 G80_KNOCK_LEARN_2

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2016 to 2026.

Knock learn cylinder 3 G80_KNOCK_LEARN_3

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2016 to 2026.

Knock learn cylinder 4 G80_KNOCK_LEARN_4

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder #1 G80_KNOCK_RETARD_CYLINDER_1

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder #2 G80_KNOCK_RETARD_CYLINDER_2

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder #3 G80_KNOCK_RETARD_CYLINDER_3

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder #4 G80_KNOCK_RETARD_CYLINDER_4

  • Request21 16
  • Service 21PID 16
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val × 0.75)
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 1 G80_KNOCK_RETARD_1

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 1 G80_KNOCK_RETARD_CYL_1

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 1, alternate G80_KNOCK_RETARD_1_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 1, alternate G80_KNOCK_RETARD_CYL_1_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 167 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 2 G80_KNOCK_RETARD_2

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 111 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 2 G80_KNOCK_RETARD_CYL_2

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 2, alternate G80_KNOCK_RETARD_2_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 2, alternate G80_KNOCK_RETARD_CYL_2_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 168 to 175 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 3 G80_KNOCK_RETARD_3

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 112 to 119 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 3 G80_KNOCK_RETARD_CYL_3

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 3, alternate G80_KNOCK_RETARD_3_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 3, alternate G80_KNOCK_RETARD_CYL_3_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 183 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 4 G80_KNOCK_RETARD_4

  • Request22 E0 0A
  • Service 22DID E00A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 120 to 127 of the reply, 8 bits. The value is signed.

Formula
(val ÷ 5)
Range
-25.6 to 25.4 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 4 G80_KNOCK_RETARD_CYL_4

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 4, alternate G80_KNOCK_RETARD_4_E019

  • Request22 E0 19
  • Service 22DID E019
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 199 of the reply, 8 bits.

Formula
(val × 0.75 − 191.25)
Range
-191.25 to 0 °
Unit
°

In testing for 2016 to 2026.

Knock retard cylinder 4, alternate G80_KNOCK_RETARD_CYL_4_ALT

  • Request21 0A
  • Service 21PID 0A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 184 to 191 of the reply, 8 bits.

Formula
(val ÷ 1.333333333)
Range
0 to 191.25 °
Unit
°

In testing for 2016 to 2026.

Main injection volume G80_MAIN_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 103 of the reply, 8 bits.

Formula
(val × 0.392156863)
Range
0 to 100 L
Unit
L

In testing for 2016 to 2026.

Mass air flow rate G80_MAF_RATE

  • Request22 E0 10
  • Service 22DID E010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 215 of the reply, 8 bits. The bytes are in little-endian order.

Formula
(val × 0.04239)
Range
0 to 10.8
Unit
Raw value

In testing for 2016 to 2026.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine running G80_MAX_ADPT_LO_MECH_STOP_P

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 480 to 495 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
0 to 10.02 V
Unit
V

In testing for 2016 to 2026.

Max adaptation value for lower mechanical stop of the boost pressure actuator during engine stop G80_MAX_ADPT_LO_MECH_P

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 464 to 479 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
0 to 10.02 V
Unit
V

In testing for 2016 to 2026.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine running G80_MIN_ADPT_LO_MECH_STOP_P

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 512 to 527 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
0 to 10.02 V
Unit
V

In testing for 2016 to 2026.

Min adaptation value for lower mechanical stop of the boost pressure actuator during engine stop G80_MIN_ADPT_LO_MECH_P

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 496 to 511 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 1.53 ÷ 10000)
Range
0 to 10.02 V
Unit
V

In testing for 2016 to 2026.

Misfire count #1 G80_MIS_1

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfire count #2 G80_MIS_2

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 72 to 87 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfire count #3 G80_MIS_3

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 88 to 103 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfire count #4 G80_MIS_4

  • Request21 01
  • Service 21PID 01
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires current total G80_MIS_CURRENT_TOT

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 584 to 591 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Misfires current, cylinder 1 G80_MIS_CURRENT_1

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 536 to 543 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Misfires current, cylinder 2 G80_MIS_CURRENT_2

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 544 to 551 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Misfires current, cylinder 3 G80_MIS_CURRENT_3

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 552 to 559 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Misfires current, cylinder 4 G80_MIS_CURRENT_4

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 560 to 567 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Misfires current, cylinder 5 G80_MIS_CURRENT_5

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 568 to 575 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Misfires current, cylinder 6 G80_MIS_CURRENT_6

  • Request21 08
  • Service 21PID 08
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 576 to 583 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Misfires, current, cylinder 1 G80_MISFIRES_C1_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires, current, cylinder 2 G80_MISFIRES_C2_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires, current, cylinder 3 G80_MISFIRES_C3_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires, current, cylinder 4 G80_MISFIRES_C4_CUR

  • Request22 E0 0D
  • Service 22DID E00D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Motor-driven power steering current G80_MDPS_MOTOR_CURRENT

  • Request22 01 01
  • Service 22DID 0101
  • Module7D4 → 7DC
  • Every5 s
  • Testing

Bits 88 to 95 of the reply, 8 bits. The value is signed.

Formula
val
Range
-128 to 127 A
Unit
A

In testing for 2016 to 2026.

Oxygen sensor 1 bank 1 G80_OXYGEN_SENSOR_11

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val × 0.00521 − 0.2)
Range
-0.2 to 1.12 V
Unit
V

In testing for 2016 to 2026.

Oxygen sensor 2 bank 1 G80_OXYGEN_SENSOR_21

  • Request21 02
  • Service 21PID 02
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val × 0.00521 − 0.2)
Range
-0.2 to 1.12 V
Unit
V

In testing for 2016 to 2026.

Pilot injection volume G80_PILOT_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2016 to 2026.

Post injection volume G80_POST_INJECTION_QTY

  • Request21 07
  • Service 21PID 07
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
val
Range
0 to 65535 L
Unit
L

In testing for 2016 to 2026.

Requested torque G80_REQUESTED_TORQUE

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 176 to 191 of the reply, 16 bits.

Formula
(val × 0.001526)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2026.

Requested torque limitation from traction control G80_REQ_TQ_LIM_TRACTION

  • Request22 ED 06
  • Service 22DID ED06
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 120 to 127 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2026.

Throttle position #1 G80_THROTTLE_POSITION__1

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 48 to 63 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 0.0244140625)
Range
-800 to 799 %
Unit
%

In testing for 2016 to 2026.

Throttle position #2 G80_THROTTLE_POSITION__2

  • Request21 14
  • Service 21PID 14
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 64 to 79 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 0.0244140625)
Range
-800 to 799 %
Unit
%

In testing for 2016 to 2026.

Timing advance #1 G80_TIMING_ADVANCE_1

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2016 to 2026.

Timing advance #2 G80_TIMING_ADVANCE_2

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 40 to 47 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2016 to 2026.

Timing advance #3 G80_TIMING_ADVANCE_3

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2016 to 2026.

Timing advance #4 G80_TIMING_ADVANCE_4

  • Request21 13
  • Service 21PID 13
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 63 of the reply, 8 bits. The value is signed.

Formula
(val × 0.75)
Range
-96 to 95.25 °
Unit
°

In testing for 2016 to 2026.

Torque converter slip G80_TORQUE_CONVERTER_SLIP

  • Request22 01 A0
  • Service 22DID 01A0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 128 to 143 of the reply, 16 bits.

Formula
(val ÷ 4 − 512)
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2016 to 2026.

Torque converter slip G80_TQ_CONV_SLIP

  • Request21 A0
  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 104 to 119 of the reply, 16 bits.

Formula
(val ÷ 4 − 512)
Range
-512 to 15871.75 rpm
Unit
rpm

In testing for 2016 to 2026.

Transmission fluid temperature G80_ATF_T_7E0

Pelican can show this parameter as the transmission fluid temperature.

  • Request21 A0
  • Service 21PID A0
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 264 to 271 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2016 to 2026.

Turbo boost gauge pressure G80_TURBO_BOOST

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val ÷ 831.556909 − 12)
Range
-10 to 66.81 psi
Unit
psi

In testing for 2016 to 2026.

Turbo boost pressure G80_TURBO_BOOST_P

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
(val × 829.1 ÷ 10000)
Range
0 to 5433
Unit
Raw value

In testing for 2016 to 2026.

Turbo boost pressure G80_TURBO_BOOST_P_7E0

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 56 to 71 of the reply, 16 bits.

Formula
(val × 0.008291)
Range
0 to 543
Unit
Number

In testing for 2016 to 2026.

Variable valve timing temperature G80_CVVT_T

Continuously variable valve timing temperature.

  • Request21 18
  • Service 21PID 18
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 272 to 279 of the reply, 8 bits.

Formula
(val − 48)
Range
-48 to 207 °C
Unit
°C

In testing for 2016 to 2026.

Waste gate duty G80_WASTE_GATE_DUTY

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
(val × 0.00305176)
Range
0 to 199 %
Unit
%

In testing for 2016 to 2026.

Waste gate duty G80_WG_DUTY

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 408 to 423 of the reply, 16 bits.

Formula
(val × 200 ÷ 65535)
Range
0 to 200 %
Unit
%

In testing for 2016 to 2026.

Waste gate position G80_WASTE_GATE_POS

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
(val × 0.00610352)
Range
0 to 399 %
Unit
%

In testing for 2016 to 2026.

Waste gate position G80_WG_POSITION

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 424 to 439 of the reply, 16 bits.

Formula
(val × 400 ÷ 65535)
Range
0 to 400 %
Unit
%

In testing for 2016 to 2026.

Waste gate set point G80_WG_SETPOINT

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
(val × 400 ÷ 65535)
Range
0 to 100 %
Unit
%

In testing for 2016 to 2026.

Waste gate target G80_WASTE_GATE_TGT

  • Request21 21
  • Service 21PID 21
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 440 to 455 of the reply, 16 bits.

Formula
(val × 0.00610352)
Range
0 to 399 %
Unit
%

In testing for 2016 to 2026.

Waste gate voltage G80_WG_VOLTAGE

  • Request22 E0 21
  • Service 22DID E021
  • Module7E0 → 7E8
  • Every100 ms
  • Testing

Bits 392 to 407 of the reply, 16 bits.

Formula
(val × 10 ÷ 65535)
Range
0 to 10 V
Unit
V

In testing for 2016 to 2026.

Wastegate control PWM, wastegate actuator G80_WASTEGATE_CTRL_PWM

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 416 to 431 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 100 ÷ 32767)
Range
-100 to 100 %
Unit
%

In testing for 2016 to 2026.

Wastegate position target, wastegate actuator G80_WASTEGATE_POS_TGT

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 448 to 463 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 200 ÷ 32767)
Range
-200 to 200 %
Unit
%

In testing for 2016 to 2026.

Wastegate position, wastegate actuator G80_WASTEGATE_POS

  • Request21 19
  • Service 21PID 19
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The value is signed. The bytes are in little-endian order.

Formula
(val × 200 ÷ 32767)
Range
-200 to 200 %
Unit
%

In testing for 2016 to 2026.

Wide open throttle G80_WIDE_OPEN_THROTTLE

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2016 to 2026.

Engine › Misfires

Emission-relevant misfires, cylinder #1 G80_MIS_CNT_EMIS_1

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission-relevant misfires, cylinder #2 G80_MIS_CNT_EMIS_2

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission-relevant misfires, cylinder #3 G80_MIS_CNT_EMIS_3

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Emission-relevant misfires, cylinder #4 G80_MIS_CNT_EMIS_4

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 96 to 111 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires harmful for catalyst cylinder 1 G80_MIS_CAT_1

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 160 to 175 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires harmful for catalyst cylinder 2 G80_MIS_CAT_2

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires harmful for catalyst cylinder 3 G80_MIS_CAT_3

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires harmful for catalyst cylinder 4 G80_MIS_CAT_4

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires total counter, all cylinders G80_MIS_CNT_ALL

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 432 to 447 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires total counter, cylinder #1 G80_MIS_CNT_1

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 176 to 191 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires total counter, cylinder #2 G80_MIS_CNT_2

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 192 to 207 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires total counter, cylinder #3 G80_MIS_CNT_3

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 208 to 223 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires total counter, cylinder #4 G80_MIS_CNT_4

  • Request21 0D
  • Service 21PID 0D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 224 to 239 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires, cylinder 1 G80_MIS_1_7E0

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 32 to 47 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires, cylinder 2 G80_MIS_2_7E0

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 48 to 63 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires, cylinder 3 G80_MIS_3_7E0

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 64 to 79 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Misfires, cylinder 4 G80_MIS_4_7E0

  • Request21 1D
  • Service 21PID 1D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 80 to 95 of the reply, 16 bits. The bytes are in little-endian order.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 2016 to 2026.

Engine › Unknown

Engine status byte G80_E004_BYTE0

  • Request22 E0 04
  • Service 22DID E004
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100
Unit
Number

In testing for 2016 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.