Genesis G80

Climate parameters

The Genesis G80 has 7 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Defogging? G80_DEFOG_SW

  • Request22 BC 03
  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing

Bit 62 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2016 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Defogging? G80_DEFOG_SW

  • Request22 BC 03
  • Service 22DID BC03
  • Module770 → 778
  • Every2 s
  • Testing

Bit 62 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

In testing for 2016 to 2026.

Evaporator temperature G80_HVAC_EVAPORATOR_T

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2016 to 2026.

Exterior temperature G80_TEMP_EXT

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 80 °C
Unit
°C

In testing for 2016 to 2026.

Humidity sensor for automatic defogger G80_HVAC_DEFOG_HUMIDITY

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 200 to 207 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 2016 to 2026.

Interior temperature G80_TEMP_INT

  • Request22 01 00
  • Service 22DID 0100
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 80 °C
Unit
°C

In testing for 2016 to 2026.

Interior temperature, passenger legs vent G80_HVAC_IAT_PASSENGER_LEGS_VENT

  • Request22 01 01
  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 72 to 79 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2016 to 2026.

Interior temperature, passenger vent G80_HVAC_IAT_PASSENGER_VENT

  • Request22 01 01
  • Service 22DID 0101
  • Module7B3 → 7BB
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 2016 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.