Ford Transit

Drivetrain parameters

The Ford Transit has 4 drivetrain parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Primary motor coil temperature TRANSIT_PRI_MOTOR_COIL_T

  • Request22 48 1F
  • Service 22DID 481F
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

In testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026. Not supported for 2014 to 2015, 2018, 2021, 2023 to 2025, 2027.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Primary motor coil temperature TRANSIT_PRI_MOTOR_COIL_T

  • Request22 48 1F
  • Service 22DID 481F
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

In testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026. Not supported for 2014 to 2015, 2018, 2021, 2023 to 2025, 2027.

Primary motor inverter temperature TRANSIT_PRI_MOTOR_INV_T

  • Request22 48 24
  • Service 22DID 4824
  • Module7E6 → 7EE
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-40 to 300 °C
Unit
°C

In testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026. Not supported for 2014 to 2015, 2018, 2021, 2023 to 2025, 2027.

Primary motor speed TRANSIT_PRI_MOTOR_RPM

  • Request22 1E 2C
  • Service 22DID 1E2C
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-6000 to 12000 rpm
Unit
rpm

In testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026. Not supported for 2014 to 2015, 2018, 2021, 2023 to 2025, 2027.

Primary motor torque TRANSIT_PRI_MOTOR_TQ

  • Request22 48 1C
  • Service 22DID 481C
  • Module7E6 → 7EE
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-200 to 200 N·m
Unit
N·m

In testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026. Not supported for 2014 to 2015, 2018, 2021, 2023 to 2025, 2027.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.