Ford Transit

Climate parameters

The Ford Transit has 10 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C compressor pressure TRANSIT_AC_PConfirmed

  • Request22 03 93
  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2013, 2016 to 2017, 2019 to 2027

Example reply from a 2018 Ford Transit.

Bits 0 to 15 of the reply, 16 bits.

0x0125 = 293 → (293 × 245251 ÷ 845473) = 84.99212 psi

Formula
(val × 245251 ÷ 845473)
Range
0 to 1000 psi
Unit
psi

Confirmed for 2014 to 2015, 2018. In testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026. Not supported for 2021, 2023 to 2025, 2027.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor pressure TRANSIT_AC_PConfirmed

  • Request22 03 93
  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2013, 2016 to 2017, 2019 to 2027

Example reply from a 2018 Ford Transit.

Bits 0 to 15 of the reply, 16 bits.

0x0125 = 293 → (293 × 245251 ÷ 845473) = 84.99212 psi

Formula
(val × 245251 ÷ 845473)
Range
0 to 1000 psi
Unit
psi

Confirmed for 2014 to 2015, 2018. In testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026. Not supported for 2021, 2023 to 2025, 2027.

A/C compressor pressure sensor voltage TRANSIT_AC_P_SENS_VConfirmed

  • Request22 98 00
  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026

Example reply from a 2027 Ford Transit.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0389 = 905 → (905 ÷ 1024) = 0.883789 V

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

Confirmed for 2014 to 2015, 2018, 2021, 2023 to 2025, 2027. In testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026.

A/C compressor, state TRANSIT_AC_STATEConfirmed

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026 to 2027

Example reply from a 2025 Ford Transit.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → 0

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2014 to 2015, 2018, 2021, 2023 to 2025. In testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026. Not supported for 2027.

A/C refrigerant pressure TRANSIT_PCM_A_C_REFRIG_PConfirmed

  • Request22 06 04
  • Service 22DID 0604
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2017, 2019 to 2020, 2022, 2026

Example reply from a 2027 Ford Transit.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0190 = 400 → 400 kPa

Formula
val
Range
-32768 to 32767 kPa
Unit
kPa

Confirmed for 2018, 2021, 2023 to 2025, 2027. In testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026. Not supported for 2014 to 2015.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2015, 2023, 2025. Supported for 2014, 2024, 2027.

Ambient temperature sensor voltage TRANSIT_AAT_VConfirmed

  • Request22 03 BA
  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every1 s
  • Testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026

Example reply from a 2027 Ford Transit.

Bits 0 to 15 of the reply, 16 bits.

0x0297 = 663 → (663 × 5 ÷ 1023) = 3.240469 V

Formula
(val × 5 ÷ 1023)
Range
0 to 5 V
Unit
V

Confirmed for 2014 to 2015, 2018, 2021, 2023 to 2025, 2027. In testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026.

Ambient temperature, alternate TRANSIT_AAT_ALTConfirmed

  • Request22 05 7D
  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 1988 to 2014, 2016 to 2017, 2019 to 2020, 2022, 2026 to 2027

Example reply from a 2025 Ford Transit.

Bits 0 to 7 of the reply, 8 bits.

0x60 = 96 → (96 ÷ 2 − 40) = 8 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2015, 2018, 2021, 2023 to 2025. In testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026. Not supported for 2014, 2027.

Coolant heater operation mode TRANSIT_COOLANT_HTR_OP_MODE

  • Request22 48 DF
  • Service 22DID 48DF
  • Module7E6 → 7EE
  • Every10 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
0OFFOff
1ONOn
2DEGRADEDDegraded
3SHUTDOWNShutdown
4SHORTShort
5NO_RESPONSENo response
6UNKNOWNUnknown
7STOPStop

In testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026. Not supported for 2014 to 2015, 2018, 2021, 2023 to 2025, 2027.

Exterior temperature TRANSIT_AAT

  • Request22 DD 05
  • Service 22DID DD05
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 1988 to 2013, 2015 to 2026

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026. Supported for 2014, 2027. Not supported for 2015, 2018, 2021, 2023 to 2025.

Interior temperature TRANSIT_IAT

  • Request22 DD 04
  • Service 22DID DD04
  • Module7E2 → 7EA
  • Every5 s
  • Testing for 1988 to 2013, 2015 to 2027

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1988 to 2013, 2016 to 2017, 2019 to 2020, 2022, 2026. Supported for 2014. Not supported for 2015, 2018, 2021, 2023 to 2025, 2027.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.