Ford Taurus

Climate parameters

The Ford Taurus has 6 climate parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

A/C compressor, state TAURUS_AC_STATEConfirmed

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016

Example reply from a 2020 Ford Taurus.

Bits 0 to 7 of the reply, 8 bits.

0x01 = 1 → 1

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013 to 2015, 2017 to 2018, 2020. In testing for 2016. Not supported for 2000, 2008 to 2009, 2011.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

A/C compressor pressure TAURUS_AC_PConfirmed

  • Request22 03 93
  • Service 22DID 0393
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2016, 2019 to 2020, 2022

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 245251 ÷ 845473)
Range
0 to 1000 psi
Unit
psi

Confirmed for 2013 to 2015, 2017 to 2018. In testing for 2016, 2019, 2022. Not supported for 2020.

A/C compressor pressure sensor voltage TAURUS_AC_P_SENS_VConfirmed

  • Request22 98 00
  • Service 22DID 9800
  • Module7E0 → 7E8
  • Every2 s
  • Testing for 2016

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 1024)
Range
0 to 5 V
Unit
V

Confirmed for 2013 to 2015, 2017 to 2018, 2020. In testing for 2016. Not supported for 2000, 2008 to 2009, 2011.

A/C compressor, state TAURUS_AC_STATEConfirmed

  • Request22 09 9B
  • Service 22DID 099B
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016

Example reply from a 2020 Ford Taurus.

Bits 0 to 7 of the reply, 8 bits.

0x01 = 1 → 1

Formula
val
Range
0 to 1
Unit
Off or on

Confirmed for 2013 to 2015, 2017 to 2018, 2020. In testing for 2016. Not supported for 2000, 2008 to 2009, 2011.

Ambient air temperature AATSAE J1979Confirmed

  • Request01 46
  • Service 01PID 46
  • Module7E0 → 7E8
  • Every15 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2008 to 2009, 2014, 2018.

Ambient temperature sensor voltage TAURUS_AAT_VConfirmed

  • Request22 03 BA
  • Service 22DID 03BA
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016

Example reply from a 2020 Ford Taurus.

Bits 0 to 15 of the reply, 16 bits.

0x0244 = 580 → (580 × 5 ÷ 1023) = 2.8348 V

Formula
(val × 5 ÷ 1023)
Range
0 to 5 V
Unit
V

Confirmed for 2013 to 2015, 2017 to 2018, 2020. In testing for 2016. Not supported for 2012.

Ambient temperature, alternate TAURUS_AAT_ALTConfirmed

  • Request22 05 7D
  • Service 22DID 057D
  • Module7E0 → 7E8
  • Every5 s
  • Testing for 2016

Example reply from a 2020 Ford Taurus.

Bits 0 to 7 of the reply, 8 bits.

0x7C = 124 → (124 ÷ 2 − 40) = 22 °C

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

Confirmed for 2013 to 2015, 2017 to 2018, 2020. In testing for 2016. Not supported for 2000, 2008 to 2009, 2011.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.