Battery parameters
The Ford Taurus has 25 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
Battery age TAURUS_BATT_AGEConfirmed
- Request
22 40 27 - Service 22
DID 4027 - Module
726 → 72E - Every
3600 s - Testing for 2016, 2019 to 2020, 2022
Example reply from a 2018 Ford Taurus.
Bits 0 to 15 of the reply, 16 bits.
0x003F = 63 → 63
- Formula
val- Range
- 0 to 1825
- Unit
- Number
Confirmed for 2013 to 2015, 2017 to 2018. In testing for 2016, 2019, 2022. Not supported for 2000, 2008 to 2009, 2011, 2020.
Battery capacity too low for start/stop TAURUS_BAT_CAP_TOO_LOW
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 5 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022. Not supported for 2014 to 2015.
Battery charge TAURUS_BATT_SOCConfirmed
- Request
22 40 28 - Service 22
DID 4028 - Module
726 → 72E - Every
10 s - Testing for 2016, 2019 to 2020, 2022
Example reply from a 2018 Ford Taurus.
Bits 0 to 7 of the reply, 8 bits.
0x63 = 99 → (99 × 100 ÷ 255) = 38.823529 %
- Formula
(val × 100 ÷ 255)- Range
- 0 to 100 %
- Unit
- %
Confirmed for 2013 to 2015, 2017 to 2018. In testing for 2016, 2019, 2022. Not supported for 2000, 2008 to 2009, 2011, 2020.
Battery current too high for start/stop TAURUS_BAT_CURRENT_TOO_HIGH
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 2 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022. Not supported for 2014 to 2015.
Battery current, predicted TAURUS_BAT_CURRENT
- Request
22 42 09 - Service 22
DID 4209 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 23 of the reply, 24 bits.
- Formula
(val ÷ 4)- Range
- 0 to 4194303.75 A
- Unit
- A
In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022. Not supported for 2014 to 2015.
Battery quiescent current, low range TAURUS_BAT_QUIESCENT
- Request
22 40 25 - Service 22
DID 4025 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 1000)- Range
- -1000 to 31767.5 mA
- Unit
- mA
In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022. Not supported for 2014 to 2015.
Battery refresh cycle in progress for start/stop TAURUS_BAT_REFRESH_CYCLE
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 14 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022. Not supported for 2014 to 2015.
Battery state detection status TAURUS_BAT_ST_DETECTION
- Request
22 42 0A - Service 22
DID 420A - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022. Not supported for 2014 to 2015.
Battery state of charge too low for start/stop TAURUS_BAT_ST_CHG_TOO_LOW
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 4 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022. Not supported for 2014 to 2015.
Battery temperature TAURUS_BATT_TEMPConfirmed
- Request
22 40 29 - Service 22
DID 4029 - Module
726 → 72E - Every
10 s - Testing for 2016, 2019 to 2020, 2022
Example reply from a 2018 Ford Taurus.
Bits 0 to 7 of the reply, 8 bits.
0x64 = 100 → (100 − 40) = 60 °C
- Formula
(val − 40)- Range
- -40 to 100 °C
- Unit
- °C
Confirmed for 2013 to 2015, 2017 to 2018. In testing for 2016, 2019, 2022. Not supported for 2000, 2008 to 2009, 2011, 2020.
Battery temperature too low for auto stop TAURUS_BAT_T_TOO_LOW_AUTO
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 13 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022. Not supported for 2014 to 2015.
Battery voltage TAURUS_BAT_V
- Request
22 11 72 - Service 22
DID 1172 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 16)- Range
- 0 to 15.9375 V
- Unit
- V
In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022. Not supported for 2014 to 2015.
Battery voltage too low for auto restart TAURUS_BAT_V_TOO_LOW_AUTO
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 12 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022. Not supported for 2014 to 2015.
Battery voltage too low for cold cranking capability TAURUS_BAT_V_TOO_LOW_COLD
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 6 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022. Not supported for 2014 to 2015.
Battery voltage too low for start/stop TAURUS_BAT_V_TOO_LOW_START
- Request
22 41 A9 - Service 22
DID 41A9 - Module
726 → 72E - Every
5 s - Testing
Bit 3 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022. Not supported for 2014 to 2015.
Charge air temperature TAURUS_CHG_AIR_T
- Request
22 05 1C - Service 22
DID 051C - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022. Not supported for 2014 to 2015.
Commanded generator voltage TAURUS_CMD_GEN_VConfirmed
- Request
22 03 04 - Service 22
DID 0304 - Module
7E0 → 7E8 - Every
1 s - Testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022
Example reply from a 2015 Ford Taurus.
Bits 0 to 15 of the reply, 16 bits.
0x6E33 = 28211 → (28211 × 0.000488) = 13.766968 V
- Formula
(val × 0.000488)- Range
- 0 to 16 V
- Unit
- V
Confirmed for 2014 to 2015. In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2008 to 2009, 2011, 2013 to 2014, 2017 to 2018. Supported for 2010, 2015 to 2016, 2020, 2022.
Normalized cumulative charge when ignition is on TAURUS_NORM_CUM_CHG_IGN_ONConfirmed
- Request
22 40 1E - Service 22
DID 401E - Module
726 → 72E - Every
1 s - Testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022
Example reply from a 2015 Ford Taurus.
Bits 0 to 15 of the reply, 16 bits.
0x002C = 44 → (44 ÷ 10) = 4.4
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Number
Confirmed for 2014 to 2015. In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022.
Normalized cumulative discharge from battery with engine off TAURUS_NORM_CUM_DCHG_BAT_OFFConfirmed
- Request
22 40 26 - Service 22
DID 4026 - Module
726 → 72E - Every
1 s - Testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022
Example reply from a 2015 Ford Taurus.
Bits 0 to 15 of the reply, 16 bits.
0x0001 = 1 → (1 ÷ 10) = 0.1
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Number
Confirmed for 2014 to 2015. In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022.
Normalized cumulative discharge from battery with engine on TAURUS_NORM_CUM_DCHG_BAT_ONConfirmed
- Request
22 40 21 - Service 22
DID 4021 - Module
726 → 72E - Every
1 s - Testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022
Example reply from a 2015 Ford Taurus.
Bits 0 to 15 of the reply, 16 bits.
0x0004 = 4 → (4 ÷ 10) = 0.4
- Formula
(val ÷ 10)- Range
- 0 to 6553.5
- Unit
- Number
Confirmed for 2014 to 2015. In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022.
Vehicle battery B current TAURUS_VEH_BAT_B_CURRENT
- Request
22 42 3C - Service 22
DID 423C - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 32)- Range
- -1024 to 1023.96 A
- Unit
- A
In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022. Not supported for 2014 to 2015.
Vehicle battery B voltage TAURUS_VEH_BAT_B_V
- Request
22 41 E8 - Service 22
DID 41E8 - Module
726 → 72E - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 20 + 6)- Range
- 6 to 18.75 V
- Unit
- V
In testing for 1988 to 2006, 2008 to 2013, 2016 to 2020, 2022. Not supported for 2014 to 2015.
Vehicle battery current TAURUS_VEH_BAT_CURRENTConfirmed
- Request
22 40 2B - Service 22
DID 402B - Module
726 → 72E - Every
1 s - Testing for 1988 to 2006, 2008 to 2013, 2016 to 2017, 2019 to 2020, 2022
Example reply from a 2018 Ford Taurus.
Bits 0 to 7 of the reply, 8 bits.
0x80 = 128 → (128 − 127) = 1 A
- Formula
(val − 127)- Range
- -127 to 128 A
- Unit
- A
Confirmed for 2014 to 2015, 2018. In testing for 1988 to 2006, 2008 to 2013, 2016 to 2017, 2019 to 2020, 2022.
Vehicle battery voltage TAURUS_VEH_BAT_VConfirmed
Pelican can show this parameter as the starter battery voltage.
- Request
22 40 2A - Service 22
DID 402A - Module
726 → 72E - Every
5 s - Testing for 1988 to 2006, 2008 to 2013, 2016 to 2017, 2019 to 2020, 2022
Example reply from a 2018 Ford Taurus.
Bits 0 to 7 of the reply, 8 bits.
0x5C = 92 → (92 ÷ 20 + 6) = 10.6 V
- Formula
(val ÷ 20 + 6)- Range
- 6 to 18.75 V
- Unit
- V
Confirmed for 2014 to 2015, 2018. In testing for 1988 to 2006, 2008 to 2013, 2016 to 2017, 2019 to 2020, 2022.