Battery parameters
The Ford Focus Electric has 12 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
12V battery age FOCUSEV_12V_AGE
- Request
22 40 27 - Service 22
DID 4027 - Module
726 → 72E - Every
3600 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 24)- Range
- 0 to 1572840 h
- Unit
- h
In testing for 2012 to 2018.
12V battery state of charge FOCUSEV_12V_SOC
- Request
22 40 28 - Service 22
DID 4028 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2018.
12V battery temperature FOCUSEV_12V_T
- Request
22 40 29 - Service 22
DID 4029 - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 100 °C
- Unit
- °C
In testing for 2012 to 2018.
12V battery voltage FOCUSEV_12V_V
Pelican can show this parameter as the starter battery voltage.
- Request
22 40 2A - Service 22
DID 402A - Module
726 → 72E - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 20 + 6)- Range
- 0 to 18.75 V
- Unit
- V
In testing for 2012 to 2018.
HV battery charge FOCUSEV_HVBAT_SOC
Pelican can show this parameter as the state of charge.
- Request
22 48 01 - Service 22
DID 4801 - Module
7E4 → 7EC - Every
30 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 500)- Range
- 0 to 100 %
- Unit
- %
In testing for 2012 to 2018.
HV battery current FOCUSEV_HVBAT_A
- Request
22 48 0B - Service 22
DID 480B - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 50)- Range
- -300 to 300 A
- Unit
- A
In testing for 2012 to 2018.
HV battery minimum module voltage FOCUSEV_HVBAT_MIN_MOD_V
- Request
22 48 40 - Service 22
DID 4840 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65.535 V
- Unit
- V
In testing for 2012 to 2018.
HV battery temperature FOCUSEV_HVBAT_T
- Request
22 48 00 - Service 22
DID 4800 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2018.
HV battery temperature, average FOCUSEV_HVBAT_T_AVG
- Request
22 48 08 - Service 22
DID 4808 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 24 to 31 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2018.
HV battery temperature, maximum FOCUSEV_HVBAT_T_MAX
- Request
22 48 08 - Service 22
DID 4808 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2018.
HV battery temperature, minimum FOCUSEV_HVBAT_T_MIN
- Request
22 48 08 - Service 22
DID 4808 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 8 to 15 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2012 to 2018.
HV battery voltage FOCUSEV_HVBAT_V
Pelican can show this parameter as the traction battery voltage.
- Request
22 48 0D - Service 22
DID 480D - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
In testing for 2012 to 2018.