Throttle inlet pressure absolute EDGE_TIP_ABSConfirmed

  • Request22 03 3E
  • Service 22DID 033E
  • Module7E0
  • Every250 ms
  • Testing for 2007 to 2014, 2016, 2024

Example reply from a 2023 Ford Edge.

Bits 0 to 15 of the reply, 16 bits.

0x335A = 13146 → (13146 × 0.0011064263) = 14.54508 psi

Formula
(val × 0.0011064263)
Range
0 to 60 psi
Unit
psi

Confirmed for 2015, 2017 to 2023. In testing for 2007, 2009, 2011 to 2012, 2016, 2024. Not supported for 2008, 2010, 2013 to 2014.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Throttle inlet pressure absolute EDGE_TIP_ABSConfirmed

  • Request22 03 3E
  • Service 22DID 033E
  • Module7E0
  • Every250 ms
  • Testing for 2007 to 2014, 2016, 2024

Example reply from a 2023 Ford Edge.

Bits 0 to 15 of the reply, 16 bits.

0x335A = 13146 → (13146 × 0.0011064263) = 14.54508 psi

Formula
(val × 0.0011064263)
Range
0 to 60 psi
Unit
psi

Confirmed for 2015, 2017 to 2023. In testing for 2007, 2009, 2011 to 2012, 2016, 2024. Not supported for 2008, 2010, 2013 to 2014.

Throttle inlet pressure sensor voltage EDGE_TIP_VConfirmed

  • Request22 03 3C
  • Service 22DID 033C
  • Module7E0
  • Every250 ms
  • Testing for 2007 to 2014, 2016, 2024

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 0.0048828125)
Range
0 to 5 V
Unit
V

Confirmed for 2015, 2017 to 2023. In testing for 2007, 2009, 2011 to 2012, 2016, 2024. Not supported for 2008, 2010, 2013 to 2014.