Battery parameters
The Ford Edge has 9 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
Charging state EDGE_CHRG_STATE
Pelican can show this parameter as the charging state.
- Request
22 48 4F - Service 22
DID 484F - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NOT_READY | Not ready |
1 | READY | Ready |
2 | FAULT | Fault |
3 | WAIT | Wait Check |
4 | PRE_COND | Pre-condition |
5 | CHARGING | Charging |
6 | DONE | Done |
7 | EXT | External Charger |
8 | INIT | Initializing |
In testing for 2007, 2009, 2011 to 2012, 2016, 2024. Not supported for 2008, 2010, 2013 to 2015, 2017 to 2023.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2013 to 2015, 2017 to 2018, 2020 to 2023. Supported for 2010, 2016, 2019, 2024.
HV battery age EDGE_HVBAT_AGE
- Request
22 48 10 - Service 22
DID 4810 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 720 ÷ 200)- Range
- 0 to 235926 h
- Unit
- h
In testing for 2007, 2009, 2011 to 2012, 2024. Not supported for 2008, 2010, 2013 to 2023.
HV battery charge EDGE_HVBAT_SOC
High resolution state of charge.
Pelican can show this parameter as the state of charge.
- Request
22 48 01 - Service 22
DID 4801 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 500)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007, 2009, 2011 to 2012, 2016, 2024. Not supported for 2008, 2010, 2013 to 2015, 2017 to 2023.
HV battery charge (displayed) EDGE_HVBAT_SOC_DISP
The state of charge displayed on the vehicle's dashboard.
Pelican can show this parameter as the state of charge.
- Request
22 48 45 - Service 22
DID 4845 - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007, 2009, 2011 to 2012, 2024. Not supported for 2008, 2010, 2013 to 2023.
HV battery energy EDGE_HVBAT_KWH
- Request
22 48 48 - Service 22
DID 4848 - Module
7E4 → 7EC - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 500)- Range
- 0 to 131.07 kWh
- Unit
- kWh
In testing for 2007, 2009, 2011 to 2012, 2016, 2024. Not supported for 2008, 2010, 2013 to 2015, 2017 to 2023.
HV battery state of health EDGE_HVBAT_SOH
Pelican can show this parameter as the state of health.
- Request
22 49 0C - Service 22
DID 490C - Module
7E4 → 7EC - Every
3600 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 2)- Range
- 0 to 100 %
- Unit
- %
In testing for 2007, 2009, 2011 to 2012, 2024. Not supported for 2008, 2010, 2013 to 2023.
HV battery temperature EDGE_HVBAT_T
- Request
22 48 00 - Service 22
DID 4800 - Module
7E4 → 7EC - Every
10 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2007, 2009, 2011 to 2012, 2016, 2024. Not supported for 2008, 2010, 2013 to 2015, 2017 to 2023.
HV battery voltage EDGE_HVBAT_V
- Request
22 48 0D - Service 22
DID 480D - Module
7E4 → 7EC - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
In testing for 2007, 2009, 2011 to 2012, 2016, 2024. Not supported for 2008, 2010, 2013 to 2015, 2017 to 2023.