FIAT 500e

Engine parameters

The FIAT 500e has 17 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Air conditioning refrigerant pressure 500E_AC_REFRIGERANT_P

  • Request22 40 01
  • Service 22DID 4001
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 bar
Unit
bar

In testing for 2020 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Air conditioning refrigerant pressure 500E_AC_REFRIGERANT_P

  • Request22 40 01
  • Service 22DID 4001
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2)
Range
0 to 127 bar
Unit
bar

In testing for 2020 to 2026.

Air heater core temperature 500E_AIRHEATER_CORE_T

  • Request22 40 55
  • Service 22DID 4055
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Air heater current 500E_AIRHEATER_CURRENT

  • Request22 40 55
  • Service 22DID 4055
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val ÷ 4)
Range
0 to 63.75 A
Unit
A

In testing for 2020 to 2026.

Air heater power consumption 500E_AIRHEATER_POWER_CONS

  • Request22 40 55
  • Service 22DID 4055
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2020 to 2026.

Drive motor coolant inlet temperature 500E_EMOTOR_CLT_INLET_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Drive motor coolant outlet temperature 500E_EMOTOR_CLT_OUTLET_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 48 to 55 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Drive motor inverter temperature 0 500E_EMOTOR_INVERTER_T_0

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Drive motor inverter temperature 1 500E_EMOTOR_INVERTER_T_1

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 24 to 31 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Drive motor inverter temperature 2 500E_EMOTOR_INVERTER_T_2

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Drive motor inverter temperature model 500E_EMOTOR_INVERTER_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Drive motor PCB temperature 500E_EMOTOR_PCB_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 56 to 63 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Drive motor rotor temperature 500E_EMOTOR_ROTOR_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 64 to 71 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Drive motor stator temperature 500E_EMOTOR_STATOR_T

  • Request22 30 65
  • Service 22DID 3065
  • ModuleDA42 → 42
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 2020 to 2026.

Drive motor torque achieved 500E_EMOTOR_TQ_ACHIEVED

  • Request22 30 64
  • Service 22DID 3064
  • ModuleDA42 → 42
  • Every250 ms
  • Testing

Bits 16 to 31 of the reply, 16 bits.

Formula
(val ÷ 50 − 500)
Range
-500 to 810 N·m
Unit
N·m

In testing for 2020 to 2026.

Drive motor torque limit 500E_EMOTOR_TQ_LIM

  • Request22 30 63
  • Service 22DID 3063
  • ModuleDA42 → 42
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50 − 500)
Range
-500 to 810 N·m
Unit
N·m

In testing for 2020 to 2026.

Drive motor torque, commanded 500E_EMOTOR_TQ_CMD

  • Request22 30 64
  • Service 22DID 3064
  • ModuleDA42 → 42
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 50 − 500)
Range
-500 to 810 N·m
Unit
N·m

In testing for 2020 to 2026.

Electric A/C compressor HV current 500E_EAC_HV_CURRENT

  • Request22 40 11
  • Service 22DID 4011
  • ModuleDA42 → 42
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 5)
Range
0 to 51 A
Unit
A

In testing for 2020 to 2026.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.