Dacia Sandero II

Transmission parameters

The Dacia Sandero II has 5 transmission parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Gearbox ratio DACIA_GEARBOX_RATIO

  • Request22 2C 04
  • Service 22DID 2C04
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

Gearbox ratio DACIA_GEARBOX_RATIO

  • Request22 2C 04
  • Service 22DID 2C04
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Gearbox ratio, target DACIA_GEARBOX_RATIO_TGT

  • Request22 2C 03
  • Service 22DID 2C03
  • Module7E0
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Gearbox type DACIA_GBOX_TYPE

  • Request22 4B 26
  • Service 22DID 4B26
  • Module740 → 760
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Gearbox type DACIA_GEARBOX_TYPE

  • Request22 30 50
  • Service 22DID 3050
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Transmission mode button position DACIA_TRANS_MODE_BTN_POS

  • Request22 30 22
  • Service 22DID 3022
  • Module748
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.