Climate parameters
The Dacia Sandero II has 18 climate parameters.
● Confirmed◆ In testing○ Supported× Not supported
A/C compressor DACIA_AC_COMP
- Request
22 20 1E - Service 22
DID 201E - Module
7E0 - Every
1 s - Testing
Bit 7 of the reply.
- Formula
val- Range
- 0 to 1
- Unit
- Off or on
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
A/C compressor discharge temperature DACIA_COMP_DIS_T
- Request
22 44 0C - Service 22
DID 440C - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 30)- Range
- -30 to 32737.5 °C
- Unit
- °C
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
A/C compressor mode DACIA_COMP_MODE
- Request
22 44 02 - Service 22
DID 4402 - Module
744 → 764 - Every
5 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
1 | AC | A/C |
2 | DEICE | De-ice |
4 | HEAT_PUMP | Heat pump |
6 | DEMIST | Demisting |
7 | IDLE | Idle |
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
A/C compressor power DACIA_COMP_PWR
- Request
22 44 36 - Service 22
DID 4436 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 4)- Range
- 0 to 16383.75 W
- Unit
- W
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
A/C compressor pressure DACIA_COMP_P
- Request
22 43 69 - Service 22
DID 4369 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
A/C compressor speed DACIA_COMP_RPM
- Request
22 43 D8 - Service 22
DID 43D8 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
A/C compressor speed request DACIA_COMP_RPM_REQ
- Request
22 44 04 - Service 22
DID 4404 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
val- Range
- 0 to 65535 rpm
- Unit
- rpm
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
A/C compressor suction temperature DACIA_COMP_SUC_T
- Request
22 44 0D - Service 22
DID 440D - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 2 − 30)- Range
- -30 to 32737.5 °C
- Unit
- °C
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
Ambient air temperature DACIA_AAT
- Request
22 22 18 - Service 22
DID 2218 - Module
DADA → DA - Every
20 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 273)- Range
- -273 to 6280.5 °C
- Unit
- °C
In testing for 2008 to 2026.
Cabin temperature DACIA_CABIN_T
- Request
22 40 09 - Service 22
DID 4009 - Module
744 → 764 - Every
10 s - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
(val ÷ 10 − 40)- Range
- -3316.8 to 3236.7 °C
- Unit
- °C
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
Electric heater request DACIA_PTC_REQ
- Request
22 43 41 - Service 22
DID 4341 - Module
744 → 764 - Every
5 s - Testing
Bits 4 to 7 of the reply, 4 bits.
- Formula
val- Range
- 0 to 15
- Unit
- Number
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
Evaporator temperature DACIA_EVAP_T
- Request
22 40 0A - Service 22
DID 400A - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
Evaporator temperature set point DACIA_EVAP_T_SET
- Request
22 43 68 - Service 22
DID 4368 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10 − 40)- Range
- -40 to 6513.5 °C
- Unit
- °C
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
Heating condenser temperature DACIA_COND_T
- Request
22 44 29 - Service 22
DID 4429 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
Heating condenser temperature set point DACIA_COND_T_SET
- Request
22 43 A5 - Service 22
DID 43A5 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 512 − 40)- Range
- -40 to 87.998 °C
- Unit
- °C
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
Heating temperature DACIA_HEAT_T
- Request
22 43 A4 - Service 22
DID 43A4 - Module
744 → 764 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 256 − 40)- Range
- -40 to 215.996 °C
- Unit
- °C
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
Refrigerant pressure DACIA_REFRIG_P
- Request
22 22 2A - Service 22
DID 222A - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 10)- Range
- 0 to 6553.5 bar
- Unit
- bar
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.
Refrigerant pressure sensor voltage DACIA_REFRIG_P_SNS_V
- Request
22 20 0D - Service 22
DID 200D - Module
7E0 - Every
1 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 100)- Range
- 0 to 655.35 V
- Unit
- V
In testing for 2008 to 2022, 2024 to 2026. Not supported for 2023.