Transmission parameters
The Chrysler 300 has 24 transmission parameters.
● Confirmed◆ In testing○ Supported× Not supported
Current gear 300_CURRENT_GEAR
- Request
22 3C 22 - Service 22
DID 3C22 - Module
7E1 → 7E9 - Every
250 ms - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val ÷ 10)- Range
- 0 to 25.5
- Unit
- Number
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Current gear 300_GEARConfirmed
The automatic transmission gear.
- Request
22 55 03 - Service 22
DID 5503 - Module
7E1 → 7E9 - Every
1 s - Testing for 2005 to 2011, 2014 to 2015, 2017 to 2018, 2020 to 2021
Example reply from a 2023 Chrysler 300.
Bits 4 to 7 of the reply, 4 bits.
0b0001 = 1 → 1
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NEUTRAL | Neutral |
1 | 1 | First gear |
2 | 2 | Second gear |
3 | 3 | Third gear |
4 | 4 | Fourth gear |
5 | 5 | Fifth gear |
6 | 6 | Sixth gear |
7 | 7 | Seventh gear |
8 | 8 | Eighth gear |
9 | 9 | Ninth gear |
10 | 10 | Tenth gear |
11 | REAR | Rear |
13 | PARK | Park |
Confirmed for 2012 to 2013, 2016, 2019, 2022 to 2023. In testing for 2005 to 2011, 2014 to 2015, 2017 to 2018, 2020 to 2021.
Target gear 300_GEAR_TARGETConfirmed
The target gear.
- Request
22 55 04 - Service 22
DID 5504 - Module
7E1 → 7E9 - Every
1 s - Testing for 2005 to 2011, 2014 to 2015, 2017 to 2018, 2020 to 2021
Example reply from a 2023 Chrysler 300.
Bits 4 to 7 of the reply, 4 bits.
0b0001 = 1 → 1
- Unit
- Named states
| Raw value | State | Meaning |
|---|---|---|
0 | NEUTRAL | Neutral |
1 | 1 | First gear |
2 | 2 | Second gear |
3 | 3 | Third gear |
4 | 4 | Fourth gear |
5 | 5 | Fifth gear |
6 | 6 | Sixth gear |
7 | 7 | Seventh gear |
8 | 8 | Eighth gear |
9 | 9 | Ninth gear |
10 | 10 | Tenth gear |
11 | REAR | Rear |
13 | PARK | Park |
Confirmed for 2012 to 2013, 2016, 2019, 2022 to 2023. In testing for 2005 to 2011, 2014 to 2015, 2017 to 2018, 2020 to 2021.
Torque converter lock status 300_TQ_CONV_LOCK
- Request
22 B0 9B - Service 22
DID B09B - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Torque converter slip 300_TQ_CONV_SLIP
- Request
22 B0 28 - Service 22
DID B028 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 0 to 15 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Torque converter slip, variant 2 300_TQ_CONV_SLIP_VAR_2
- Request
22 A0 01 - Service 22
DID A001 - Module
7E0 → 7E8 - Every
250 ms - Testing
Bits 48 to 63 of the reply, 16 bits. The value is signed.
- Formula
val- Range
- -32768 to 32767 rpm
- Unit
- rpm
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Transmission fluid temperature 300_ATF_T_08DF
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 08 DF - Service 22
DID 08DF - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2005 to 2011, 2013 to 2021, 2023. Not supported for 2012, 2022.
Transmission fluid temperature 300_ATF_T_7E1
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 50 43 - Service 22
DID 5043 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2005 to 2023.
Transmission fluid temperature, variant 1 300_ATF_T_VAR_1
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 72 - Service 21
PID 72 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 32 to 47 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843 °F
- Unit
- °F
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Transmission fluid temperature, variant 2 300_ATF_T_V_2
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 18 - Service 21
PID 18 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Transmission fluid temperature, variant 2 300_ATF_T_VAR_2
- Request
22 A0 02 - Service 22
DID A002 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 58)- Range
- -58 to 401 °F
- Unit
- °F
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Transmission fluid temperature, variant 3 300_ATF_T_2130
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 30 - Service 21
PID 30 - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 88 to 95 of the reply, 8 bits.
- Formula
(val − 50)- Range
- -50 to 205 °C
- Unit
- °C
In testing for 2005 to 2011, 2013 to 2021, 2023. Not supported for 2012, 2022.
Transmission fluid temperature, variant 3 300_ATF_T_VAR_3
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 B0 10 - Service 22
DID B010 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023.9843 °F
- Unit
- °F
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Transmission gear, actual 300_GEAR_7E0
- Request
22 A0 A0 - Service 22
DID A0A0 - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Transmission gear, commanded 300_GEAR_CMD
- Request
22 A0 9F - Service 22
DID A09F - Module
7E0 → 7E8 - Every
1 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
val- Range
- 0 to 255
- Unit
- Number
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Transmission sump temperature 300_TRANS_SUMP_T
- Request
22 A0 A3 - Service 22
DID A0A3 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 640)- Range
- 0 to 921 °F
- Unit
- °F
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Transmission sump temperature 300_TRANS_SUMP_T_7E1
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 3A - Service 21
PID 3A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 72 to 87 of the reply, 16 bits.
- Formula
(val ÷ 64)- Range
- 0 to 1023 °F
- Unit
- °F
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Transmission sump temperature, variant 1 300_TRANS_SUMP_T_VAR_1
- Request
21 3A - Service 21
PID 3A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 °F
- Unit
- °F
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Transmission sump temperature, variant 2 300_TRANS_SUMP_T_VAR_2
- Request
21 CA - Service 21
PID CA - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 80 to 87 of the reply, 8 bits.
- Formula
(val × 4)- Range
- 0 to 1020 °F
- Unit
- °F
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Transmission temperature 300_ATF_TConfirmed
Pelican can show this parameter as the transmission fluid temperature.
- Request
22 04 FE - Service 22
DID 04FE - Module
7E1 → 7E9 - Every
1 s - Testing for 2005 to 2011, 2014 to 2015, 2017 to 2018, 2020 to 2021
Example reply from a 2023 Chrysler 300.
Bits 0 to 7 of the reply, 8 bits.
0x7A = 122 → (122 × 1.8 − 40) = 179.6 °F
- Formula
(val × 1.8 − 40)- Range
- -30 to 300 °F
- Unit
- °F
Confirmed for 2012 to 2013, 2016, 2019, 2022 to 2023. In testing for 2005 to 2011, 2014 to 2015, 2017 to 2018, 2020 to 2021.
Transmission temperature, variant 2 300_TRANS_T_VAR_2
Pelican can show this parameter as the transmission fluid temperature.
- Request
21 0A - Service 21
PID 0A - Module
7E1 → 7E9 - Every
5 s - Testing
Bits 128 to 135 of the reply, 8 bits.
- Formula
(val × 9 ÷ 5 − 58)- Range
- -58 to 401 °F
- Unit
- °F
In testing for 2005 to 2023.
Transmission torque converter temperature 300_TRANS_TQ_CONV_T
- Request
22 A0 A4 - Service 22
DID A0A4 - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val × 9 ÷ 320)- Range
- 0 to 1843 °F
- Unit
- °F
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Transmission torque converter temperature, variant 1 300_TRANS_TQ_CONV_T_VAR_1
- Request
21 3A - Service 21
PID 3A - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 9 ÷ 320 + 32)- Range
- 0 to 1875 °F
- Unit
- °F
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.
Transmission torque converter temperature, variant 2 300_TRANS_TQ_CONV_T_VAR_2
- Request
21 CA - Service 21
PID CA - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 96 to 111 of the reply, 16 bits.
- Formula
(val × 9 ÷ 320 + 32)- Range
- 0 to 1875 °F
- Unit
- °F
In testing for 2005 to 2011, 2013 to 2023. Not supported for 2012.