Battery parameters
The Chevrolet Traverse has 4 battery parameters.
● Confirmed◆ In testing○ Supported× Not supported
Charge air cooler temperature sensor 1 TRAVERSE_CHARGE_AIR_COOLER_T_SNS_1
- Request
22 30 AD - Service 22
DID 30AD - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2022, 2024 to 2026. Not supported for 2023.
Charge air cooler temperature sensor 2 TRAVERSE_CHARGE_AIR_COOLER_T_SNS_2
- Request
22 30 AE - Service 22
DID 30AE - Module
7E0 → 7E8 - Every
5 s - Testing
Bits 0 to 7 of the reply, 8 bits.
- Formula
(val − 40)- Range
- -40 to 215 °C
- Unit
- °C
In testing for 2009 to 2022, 2024 to 2026. Not supported for 2023.
Control module voltage VPWRSAE J1979Confirmed
Power input to the OBD control module. VPWR is normally battery voltage, less any voltage drop in the circuit between the battery and the control module.
Pelican can show this parameter as the starter battery voltage.
- Request
01 42 - Service 01
PID 42 - Module
7E0 → 7E8 - Every
10 s
Bits 0 to 15 of the reply, 16 bits.
- Formula
(val ÷ 1000)- Range
- 0 to 65535 V
- Unit
- V
Confirmed for 2011, 2018, 2023. Supported for 2015 to 2016, 2024.
Ignition 1 voltage TRAVERSE_IGN_1_VConfirmed
- Request
22 11 41 - Service 22
DID 1141 - Module
7E0 → 7E8 - Every
1 s - Testing for 2009 to 2022, 2024 to 2026
Example reply from a 2023 Chevrolet Traverse.
Bits 0 to 7 of the reply, 8 bits.
0x00 = 0 → (0 ÷ 10) = 0 V
- Formula
(val ÷ 10)- Range
- 0 to 25.5 V
- Unit
- V
Confirmed for 2023. In testing for 2009 to 2022, 2024 to 2026.