Cadillac Escalade

Engine parameters

The Cadillac Escalade has 407 engine parameters.

● Confirmed◆ In testing○ Supported× Not supported

How to read a parameter card

Engine oil temperature CADILLAC_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 00 5C
  • Service 22DID 005C
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Example reply from a 2022 Cadillac Escalade.

Bits 0 to 7 of the reply, 8 bits.

0x63 = 99 → (99 − 40) = 59 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022. In testing for 1999 to 2021, 2023 to 2026.

  1. The parameter's name and its ID in the OBDb. Confirmed shows when a response from a real car confirms the parameter.
  2. The clutch mark shows a Connectable, a parameter that Pelican surfaces in its interface.
  3. The service and PID/DID asked for, the control module it's sent to, and how often Pelican asks.
  4. The reply's bytes. The parameter's bytes are blue. Bytes for other parameters in the same reply are grayed out. Hover over a byte to see the parameter it represents.
  5. Where the parameter is in the response, and how Pelican converts the raw value into a value.
  6. A real reply, decoded. The raw value comes first, then the reading.
  7. Which model years have tested this parameter.

1-2 shift error CADILLAC_1_2_SHIFT_ERROR

  • Request22 19 97
  • Service 22DID 1997
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1999 to 2026.

1-2 shift error CADILLAC_1_2_SHIFT_ERROR_V2

  • Request22 19 97
  • Service 22DID 1997
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

1-2 shift time CADILLAC_1_2_SHIFT_TIME

  • Request22 19 93
  • Service 22DID 1993
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1999 to 2026.

1-2 shift time CADILLAC_1_2_SHIFT_TIME_V2

  • Request22 19 93
  • Service 22DID 1993
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

2-3 shift error CADILLAC_2_3_SHIFT_ERROR

  • Request22 19 98
  • Service 22DID 1998
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1999 to 2026.

2-3 shift error CADILLAC_2_3_SHIFT_ERROR_V2

  • Request22 19 98
  • Service 22DID 1998
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

2-3 shift time CADILLAC_2_3_SHIFT_TIME

  • Request22 19 94
  • Service 22DID 1994
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1999 to 2026.

2-3 shift time CADILLAC_2_3_SHIFT_TIME_V2

  • Request22 19 94
  • Service 22DID 1994
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

3-4 shift error CADILLAC_3_4_SHIFT_ERROR

  • Request22 19 99
  • Service 22DID 1999
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1999 to 2026.

3-4 shift error CADILLAC_3_4_SHIFT_ERROR_V2

  • Request22 19 99
  • Service 22DID 1999
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

3-4 shift time CADILLAC_3_4_SHIFT_TIME

  • Request22 19 95
  • Service 22DID 1995
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1999 to 2026.

3-4 shift time CADILLAC_3_4_SHIFT_TIME_V2

  • Request22 19 95
  • Service 22DID 1995
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

14V auxiliary power module enable command CADILLAC_14V_APM_ENABLE

  • Request22 1C 39
  • Service 22DID 1C39
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 128)
Range
0 to 1.99
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

14V power available CADILLAC_14V_POWER_AVAILABLE

  • Request22 41 B0
  • Service 22DID 41B0
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 16)
Range
0 to 4095 W
Unit
W

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

14V power module set point CADILLAC_14V_POWER_MODULE

  • Request22 1C 38
  • Service 22DID 1C38
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

14V power module set point voltage CADILLAC_14V_POWER_MODULE_V

  • Request22 1C 47
  • Service 22DID 1C47
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

A/C low side pressure CADILLAC_AC_LOW_SIDE

  • Request22 15 63
  • Service 22DID 1563
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Absolute load value LOAD_ABSSAE J1979Confirmed

  • Request01 43
  • Service 01PID 43
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 25700 %
Unit
%

Confirmed for 2017. Supported for 2013, 2022, 2025.

Active grille cold temperature mode CADILLAC_ACTIVE_GRILLE_COLD_T

  • Request22 23 9B
  • Service 22DID 239B
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Active grille shutter position CADILLAC_ACTIVE_GRILLE_SHUTTER_POS

  • Request22 23 66
  • Service 22DID 2366
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Active grille shutter position command CADILLAC_ACTIVE_GRILLE

  • Request22 23 64
  • Service 22DID 2364
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Air conditioning high side pressure CADILLAC_AC_HIGH_SIDE_P

  • Request22 15 64
  • Service 22DID 1564
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2.02)
Range
0 to 515.1 psi
Unit
psi

In testing for 1999 to 2026.

Air conditioning high side pressure CADILLAC_AC_HIGH_SIDE_P_V2

  • Request22 15 64
  • Service 22DID 1564
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2.02)
Range
0 to 515.1 psi
Unit
psi

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Air filter life remaining CADILLAC_AIRFILT_LIFE

  • Request22 36 A7
  • Service 22DID 36A7
  • ModuleDA11 → 2AF111
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 1999 to 2026.

Air filter life remaining CADILLAC_AIRFILT_LIFE_V2

  • Request22 36 A7
  • Service 22DID 36A7
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Air flow rate from mass air flow sensor MAFSAE J1979Confirmed

Pelican can show this parameter as the mass air flow.

  • Request01 10
  • Service 01PID 10
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655.35 g/s
Unit
g/s

Confirmed for 2017 to 2018, 2022. Supported for 2007 to 2008, 2013, 2020, 2025.

Air temperature filtered CADILLAC_AIR_TEMP_FILTERED

  • Request22 80 1F
  • Service 22DID 801F
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Air temperature unfiltered CADILLAC_AIR_TEMP_UNFILTERED

  • Request22 80 1E
  • Service 22DID 801E
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 40)
Range
-40 to 87.5 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Air/fuel ratio, commanded CADILLAC_AIR_FUEL_RAT_CMD

  • Request22 11 9E
  • Service 22DID 119E
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5
Unit
Number

In testing for 1999 to 2026.

Air/fuel ratio, commanded CADILLAC_AIR_FUEL_RAT_CMD_V2

  • Request22 11 9E
  • Service 22DID 119E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Ambient air temperature 2 CADILLAC_AIR_TEMP_AMBIENT_2

  • Request22 23 2C
  • Service 22DID 232C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

ATF temperature CADILLAC_ATF_T

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 19 40
  • Service 22DID 1940
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Axle torque driver requested CADILLAC_AXLE_TQ_DRIVER_REQ

  • Request22 24 34
  • Service 22DID 2434
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 22534)
Range
-22534 to 43001 N·m
Unit
N·m

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Axle torque driver requested CADILLAC_AXLE_TQ_DRIVER_REQ_V2

  • Request22 24 34
  • Service 22DID 2434
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 22534)
Range
-22534 to 43001 N·m
Unit
N·m

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Axle torque driver requested CADILLAC_AXLE_TQ_DRIVER_REQ_V3

  • Request22 24 34
  • Service 22DID 2434
  • Module7E2 → 7EA
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val − 22534)
Range
-22534 to 43001 N·m
Unit
N·m

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Balance rate, cylinder 1 CADILLAC_BALANCE_RATE_CYL_1

  • Request22 16 2F
  • Service 22DID 162F
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2026.

Balance rate, cylinder 1 CADILLAC_BALANCE_RATE_CYL_1_V2

  • Request22 16 2F
  • Service 22DID 162F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Balance rate, cylinder 2 CADILLAC_BALANCE_RATE_CYL_2

  • Request22 16 30
  • Service 22DID 1630
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2026.

Balance rate, cylinder 2 CADILLAC_BALANCE_RATE_CYL_2_V2

  • Request22 16 30
  • Service 22DID 1630
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Balance rate, cylinder 3 CADILLAC_BALANCE_RATE_CYL_3

  • Request22 16 31
  • Service 22DID 1631
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2026.

Balance rate, cylinder 3 CADILLAC_BALANCE_RATE_CYL_3_V2

  • Request22 16 31
  • Service 22DID 1631
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Balance rate, cylinder 4 CADILLAC_BALANCE_RATE_CYL_4

  • Request22 16 32
  • Service 22DID 1632
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2026.

Balance rate, cylinder 4 CADILLAC_BALANCE_RATE_CYL_4_V2

  • Request22 16 32
  • Service 22DID 1632
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Balance rate, cylinder 5 CADILLAC_BALANCE_RATE_CYL_5

  • Request22 16 33
  • Service 22DID 1633
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2026.

Balance rate, cylinder 5 CADILLAC_BALANCE_RATE_CYL_5_V2

  • Request22 16 33
  • Service 22DID 1633
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Balance rate, cylinder 6 CADILLAC_BALANCE_RATE_CYL_6

  • Request22 16 34
  • Service 22DID 1634
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2026.

Balance rate, cylinder 6 CADILLAC_BALANCE_RATE_CYL_6_V2

  • Request22 16 34
  • Service 22DID 1634
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Balance rate, cylinder 7 CADILLAC_BALANCE_RATE_CYL_7

  • Request22 16 35
  • Service 22DID 1635
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2026.

Balance rate, cylinder 7 CADILLAC_BALANCE_RATE_CYL_7_V2

  • Request22 16 35
  • Service 22DID 1635
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Balance rate, cylinder 8 CADILLAC_BALANCE_RATE_CYL_8

  • Request22 16 36
  • Service 22DID 1636
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2026.

Balance rate, cylinder 8 CADILLAC_BALANCE_RATE_CYL_8_V2

  • Request22 16 36
  • Service 22DID 1636
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 64 − 512)
Range
-512 to 511
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Barometric pressure BAROSAE J1979Confirmed

Normally obtained from one of a dedicated barometric sensor, a MAP sensor at key-on and during certain modes of driving, or inferred from a MAF sensor and other inputs during certain modes of driving. The control module reports BARO from whatever source it is derived from.

  • Request01 33
  • Service 01PID 33
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2020, 2022, 2025.

Barometric pressure CADILLAC_BAROMETRIC_P_V8

  • Request22 11 9D
  • Service 22DID 119D
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 1999 to 2026.

Barometric pressure, alternate CADILLAC_BAROMETRIC_P_V6

  • Request22 12 51
  • Service 22DID 1251
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 1999 to 2026.

Barometric pressure, V6 CADILLAC_BAROMETRIC_P_V6_V2

  • Request22 12 51
  • Service 22DID 1251
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Barometric pressure, V8 CADILLAC_BAROMETRIC_P_V8_V2

  • Request22 11 9D
  • Service 22DID 119D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery 5V reference voltage CADILLAC_BAT_5V_REFERENCE_V_1

  • Request22 40 D3
  • Service 22DID 40D3
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 13107 + 5)
Range
0 to 7.49 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery cell average voltage CADILLAC_BAT_CELL_AVG_V

  • Request22 C2 18
  • Service 22DID C218
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 5 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery cell average voltage 2 CADILLAC_BAT_CELL_AVG_V_2

  • Request22 44 B9
  • Service 22DID 44B9
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 8000)
Range
0 to 8.19 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery cell maximum voltage CADILLAC_BAT_CELL_MAX_V

  • Request22 43 2B
  • Service 22DID 432B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 3 ÷ 5000)
Range
0 to 39.32 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery cell minimum voltage CADILLAC_BAT_CELL_MIN_V

  • Request22 43 29
  • Service 22DID 4329
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 3 ÷ 5000)
Range
0 to 39.32 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery coolant pump speed CADILLAC_BAT_CLT_PMP_SPD

  • Request22 43 5A
  • Service 22DID 435A
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery coolant pump, commanded CADILLAC_BAT_CLT_PMP_CMD

  • Request22 43 59
  • Service 22DID 4359
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery coolant temperature CADILLAC_BAT_CLT_TEMP

  • Request22 41 A4
  • Service 22DID 41A4
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery heater power, commanded CADILLAC_BAT_HEATER_COMMAND_W

  • Request22 41 B5
  • Service 22DID 41B5
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery heater power, measured CADILLAC_BAT_HEATER_MEAS_W

  • Request22 41 B6
  • Service 22DID 41B6
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery heater, commanded CADILLAC_BAT_HEATER_COMMAND

  • Request22 43 9E
  • Service 22DID 439E
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack capacity, raw CADILLAC_BAT_PACK_CAP_AH_RAW_2017_2018

  • Request22 41 A3
  • Service 22DID 41A3
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10)
Range
0 to 6553 Ah
Unit
Ah

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack capacity, raw CADILLAC_BAT_PACK_CAP_AH_RAW_2019

  • Request22 45 F9
  • Service 22DID 45F9
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 Ah
Unit
Ah

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack coolant level switch CADILLAC_BAT_PACK_CLT_LEVEL

  • Request22 44 2C
  • Service 22DID 442C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 51)
Range
0 to 5 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack coolest module CADILLAC_BAT_PACK_TEMP_MIN_MODULE

  • Request22 43 4C
  • Service 22DID 434C
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack current HD CADILLAC_BAT_PACK_CURRENT_HD

  • Request22 40 D4
  • Service 22DID 40D4
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20)
Range
-1638 to 1638 A
Unit
A

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack hottest module CADILLAC_BAT_PACK_TEMP_MAX_MODULE

  • Request22 43 4B
  • Service 22DID 434B
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack maximum temperature CADILLAC_BAT_PACK_TEMP_MAX

  • Request22 43 49
  • Service 22DID 4349
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack maximum temperature, alternate CADILLAC_BAT_PACK_TEMP_MAX_ALT

  • Request22 24 16
  • Service 22DID 2416
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack maximum voltage CADILLAC_BAT_PACK_MAX_V

  • Request22 43 3C
  • Service 22DID 433C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 13 ÷ 25)
Range
0 to 34078 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack minimum state of charge limit CADILLAC_BAT_PACK_MIN_ST_CHG

  • Request22 43 3F
  • Service 22DID 433F
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack minimum temperature CADILLAC_BAT_PACK_TEMP_MIN

  • Request22 43 4A
  • Service 22DID 434A
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack minimum temperature, alternate CADILLAC_BAT_PACK_TEMP_MIN_ALT

  • Request22 24 17
  • Service 22DID 2417
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack minimum voltage CADILLAC_BAT_PACK_MIN_V

  • Request22 43 3B
  • Service 22DID 433B
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 13 ÷ 25)
Range
0 to 34078 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack resistance CADILLAC_BAT_PACK_RES

  • Request22 40 E9
  • Service 22DID 40E9
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 2)
Range
0 to 32767 Ω
Unit
Ω

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack state of charge raw LD 2 CADILLAC_BAT_PACK_ST_CHG_RAW_2

  • Request22 24 11
  • Service 22DID 2411
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack state of charge raw LD 3 CADILLAC_BAT_PACK_ST_CHG_RAW_3

  • Request22 43 2F
  • Service 22DID 432F
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack state of charge variation CADILLAC_BAT_PACK_ST_CHG

  • Request22 43 5F
  • Service 22DID 435F
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack temperature 1 CADILLAC_BAT_PACK_TEMP_1

  • Request22 40 D7
  • Service 22DID 40D7
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack temperature 2 CADILLAC_BAT_PACK_TEMP_2

  • Request22 40 D9
  • Service 22DID 40D9
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack temperature 3 CADILLAC_BAT_PACK_TEMP_3

  • Request22 40 DB
  • Service 22DID 40DB
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack temperature 4 CADILLAC_BAT_PACK_TEMP_4

  • Request22 40 DD
  • Service 22DID 40DD
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack temperature 5 CADILLAC_BAT_PACK_TEMP_5

  • Request22 40 DF
  • Service 22DID 40DF
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack temperature 6 CADILLAC_BAT_PACK_TEMP_6

  • Request22 40 E1
  • Service 22DID 40E1
  • Module7E7 → 7EF
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack terminal voltage LD CADILLAC_BAT_PACK_TERMINAL_V

  • Request22 82 A3
  • Service 22DID 82A3
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 510 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery pack voltage LD CADILLAC_BAT_PACK_V_LD

  • Request22 43 2D
  • Service 22DID 432D
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 13 ÷ 25)
Range
0 to 34078 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery thermal conditioning inactive time CADILLAC_BAT_THERMAL

  • Request22 24 AC
  • Service 22DID 24AC
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2)
Range
0 to 131070 s
Unit
s

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Battery thermal conditioning inactive time CADILLAC_BAT_THERMAL_V2

  • Request22 24 AC
  • Service 22DID 24AC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2)
Range
0 to 131070 s
Unit
s

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Boost pressure, actual CADILLAC_BP_ACT

  • Request22 20 E3
  • Service 22DID 20E3
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 10000)
Range
0 to 655.35 kPa
Unit
kPa

In testing for 1999 to 2026.

Boost pressure, desired CADILLAC_BP_DESConfirmed

  • Request22 32 8A
  • Service 22DID 328A
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Example reply from a 2022 Cadillac Escalade.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 100 ÷ 10000) = 0 kPa

Formula
(val × 100 ÷ 10000)
Range
0 to 655.35 kPa
Unit
kPa

Confirmed for 2022. In testing for 1999 to 2021, 2023 to 2026.

Boost pressure: actual CADILLAC_BP_ACT_V2

  • Request22 20 E3
  • Service 22DID 20E3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 10000)
Range
0 to 655.35 kPa
Unit
kPa

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Boost pressure: desired CADILLAC_BP_DES_V2

  • Request22 32 8A
  • Service 22DID 328A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 10000)
Range
0 to 655.35 kPa
Unit
kPa

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Brake pressure CADILLAC_BP

  • Request22 4A 7C
  • Service 22DID 4A7C
  • ModuleDA28 → 2AF128
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits. The value is signed.

Formula
(val × 100 − 1000)
Range
-13800 to 11700 kPa
Unit
kPa

In testing for 1999 to 2026.

Cabin A/C compressor command CADILLAC_CABIN_AC_COMP

  • Request22 45 1F
  • Service 22DID 451F
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 1)
Range
-1 to 254
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cabin A/C compressor power consumption CADILLAC_CABIN_AC_COMP_POWER

  • Request22 82 B7
  • Service 22DID 82B7
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cabin A/C compressor speed CADILLAC_CABIN_AC_COMP_SPD

  • Request22 82 B5
  • Service 22DID 82B5
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cabin A/C compressor speed commanded CADILLAC_CABIN_AC_COMP_SPD_CMD

  • Request22 82 B4
  • Service 22DID 82B4
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 rpm
Unit
rpm

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cabin A/C high side sensor pressure CADILLAC_CABIN_AC_HIGH_SIDE_P

  • Request22 15 64
  • Service 22DID 1564
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cabin A/C high side sensor voltage CADILLAC_CABIN_AC_HIGH_SIDE_V

  • Request22 11 44
  • Service 22DID 1144
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cabin A/C low side sensor pressure CADILLAC_CABIN_AC_LOW_SIDE_P

  • Request22 82 B2
  • Service 22DID 82B2
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 13647 ÷ 5000)
Range
0 to 695 kPa
Unit
kPa

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cabin A/C low side sensor voltage CADILLAC_CABIN_AC_LOW_SIDE_V

  • Request22 82 B3
  • Service 22DID 82B3
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 50)
Range
0 to 5.1 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cabin A/C power, commanded CADILLAC_CABIN_AC_COMMAND_W

  • Request22 41 B1
  • Service 22DID 41B1
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cabin A/C power, measured CADILLAC_CABIN_AC_MEAS_W

  • Request22 41 B2
  • Service 22DID 41B2
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cabin blower motor speed request CADILLAC_CABIN_BLOWER_MOTOR

  • Request22 45 1E
  • Service 22DID 451E
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cabin heater coolant control solenoid valve command CADILLAC_CABIN_HEATER_CLT

  • Request22 43 B0
  • Service 22DID 43B0
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cabin heater power, commanded CADILLAC_CABIN_HEATER_COMMAND_W

  • Request22 41 B3
  • Service 22DID 41B3
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 W
Unit
W

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cabin heater power, measured CADILLAC_CABIN_HEATER_MEAS_W

  • Request22 41 B4
  • Service 22DID 41B4
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 W
Unit
W

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Calculated engine load LOAD_PCTSAE J1979Confirmed

Represents the amount of work the engine is doing. Expected to reach 100% at wide open throttle/wide open pedal at any altitude, temperature or rpm for both naturally aspirated and boosted engines. If engine load is limited for powertrain protection e.g. engine/turbocharger protection, this value may not reach 100%. For hybrid vehicles, indicates the torque produced only by the internal combustion engine, not the torque being delivered by the entire powertrain. For electric vehicles, the meaning of this parameter is undefined.

Pelican can show this parameter as the engine load.

  • Request01 04
  • Service 01PID 04
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017 to 2018, 2022. Supported for 2007 to 2008, 2013, 2020, 2025.

Calculated engine oil pressure CADILLAC_EOP_CALC

  • Request22 1C 1B
  • Service 22DID 1C1B
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 400 ÷ 100)
Range
0 to 1020 kPa
Unit
kPa

In testing for 1999 to 2026.

Calculated engine oil pressure CADILLAC_EOP_CALC_V2

  • Request22 1C 1B
  • Service 22DID 1C1B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 400 ÷ 100)
Range
0 to 1020 kPa
Unit
kPa

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Calculated engine oil temperature CADILLAC_EOT_CALC

Pelican can show this parameter as the engine oil temperature.

  • Request22 11 54
  • Service 22DID 1154
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2026.

Calculated engine oil temperature CADILLAC_EOT_CALC_V2

Pelican can show this parameter as the engine oil temperature.

  • Request22 11 54
  • Service 22DID 1154
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Catalyst temperature bank 1, sensor 1 CATEMP11SAE J1979Confirmed

  • Request01 3C
  • Service 01PID 3C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2017. Supported for 2007 to 2008, 2020, 2022, 2025.

Catalyst temperature bank 2, sensor 1 CATEMP21SAE J1979Confirmed

  • Request01 3D
  • Service 01PID 3D
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2017. Supported for 2008, 2022, 2025.

Charger AC control pilot CADILLAC_CHARGER_AC_CTRL

  • Request22 45 46
  • Service 22DID 4546
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger AC control pilot voltage CADILLAC_CHARGER_AC_CTRL_V

  • Request22 45 45
  • Service 22DID 4545
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 20)
Range
0 to 12.75 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger AC current requested CADILLAC_CHARGER_AC_CURRENT

  • Request22 45 33
  • Service 22DID 4533
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 10)
Range
0 to 76.5 A
Unit
A

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger AC input status duty cycle CADILLAC_CHARGER_AC_INPUT

  • Request22 45 2D
  • Service 22DID 452D
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger DC output status duty cycle CADILLAC_CHARGER_DC_OUTPUT

  • Request22 45 2E
  • Service 22DID 452E
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger DC port current CADILLAC_CHARGER_DC_PORT_CURRENT

  • Request22 44 24
  • Service 22DID 4424
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128 − 256)
Range
-256 to 255 A
Unit
A

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger DC port current requested CADILLAC_CHARGER_DC_PORT_CURRENT_REQ

  • Request22 44 45
  • Service 22DID 4445
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 128 − 256)
Range
-256 to 255 A
Unit
A

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger DC port negative isolation CADILLAC_CHARGER_DC_PORT_NEGATIVE

  • Request22 44 23
  • Service 22DID 4423
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 510 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger DC port positive isolation CADILLAC_CHARGER_DC_PORT

  • Request22 44 23
  • Service 22DID 4423
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 2)
Range
0 to 510 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger DC port temperature CADILLAC_CHARGER_DC_PORT_T

  • Request22 44 25
  • Service 22DID 4425
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger last charge AC energy CADILLAC_CHARGER_LAST_CHG_AC_2017_2018

  • Request22 43 7D
  • Service 22DID 437D
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 kWh
Unit
kWh

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger last charge HV energy output CADILLAC_CHARGER_LAST_CHG_HV

  • Request22 43 7F
  • Service 22DID 437F
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 kWh
Unit
kWh

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger port lock actuator position signal CADILLAC_CHARGER_PORT_LOCK

  • Request22 44 5D
  • Service 22DID 445D
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 13107)
Range
0 to 5 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger power input available CADILLAC_CHARGER_BAT_CHARGER

  • Request22 43 76
  • Service 22DID 4376
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger power output available CADILLAC_CHARGER_POWER_OUTPUT

  • Request22 43 75
  • Service 22DID 4375
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger proximity detection circuit voltage CADILLAC_CHARGER_PROXIMITY_V

  • Request22 43 BB
  • Service 22DID 43BB
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 51)
Range
0 to 5 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger system efficiency, active test CADILLAC_CHARGER_SYSTEM_EFFICIENCY_ACTIVE

  • Request22 45 65
  • Service 22DID 4565
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25 ÷ 32)
Range
0 to 199 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger system efficiency, active test status CADILLAC_CHARGER_SYSTEM_EFFICIENCY

  • Request22 45 64
  • Service 22DID 4564
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger system efficiency, passive test CADILLAC_CHARGER_SYSTEM_EFFICIENCY_PASSIVE

  • Request22 45 66
  • Service 22DID 4566
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 40 ÷ 51)
Range
0 to 200 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger system HV interlock circuit CADILLAC_CHARGER_SYSTEM_HV_INTERLOCK

  • Request22 45 58
  • Service 22DID 4558
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger system HV interlock circuit status CADILLAC_CHARGER_SYSTEM_HV

  • Request22 45 59
  • Service 22DID 4559
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger system inactive time CADILLAC_CHARGER_SYSTEM

  • Request22 24 AB
  • Service 22DID 24AB
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2)
Range
0 to 131070 s
Unit
s

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charger total power output available CADILLAC_CHARGER_TOT_POWER

  • Request22 41 AF
  • Service 22DID 41AF
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 W
Unit
W

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Charging limit ? CADILLAC_CHG_LIM

  • Request22 41 B7
  • Service 22DID 41B7
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
val
Range
-32768 to 32767 W
Unit
W

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Clock day of week CADILLAC_CLOCK_DOW

  • Request22 44 16
  • Service 22DID 4416
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Commanded equivalence ratio EQ_RATSAE J1979Confirmed

Fuel systems that utilize conventional oxygen sensor display the inverse of the commanded open loop equivalence ratio (also known as lambda) while the fuel control system is in open loop. Will indicate 1.000 while in closed-loop fuel.

Pelican can show this parameter as the commanded lambda.

  • Request01 44
  • Service 01PID 44
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2 ÷ 65535)
Range
0 to 1.99
Unit
Number

Confirmed for 2017 to 2018, 2022. Supported for 2013, 2025.

Commanded evaporative purge EVAP_PCTSAE J1979Confirmed

  • Request01 2E
  • Service 01PID 2E
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

Commanded throttle actuator control TAC_PCTSAE J1979Confirmed

  • Request01 4C
  • Service 01PID 4C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2017. Supported for 2025.

Contactor commands CADILLAC_CONTACTOR_COMMANDS

  • Request22 43 0E
  • Service 22DID 430E
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Contactor open reason history 1 CADILLAC_CONTACTOR_OPEN_1

  • Request22 24 8C
  • Service 22DID 248C
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Contactor open reason history 2 CADILLAC_CONTACTOR_OPEN_2

  • Request22 24 8D
  • Service 22DID 248D
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Contactor open reason history 3 CADILLAC_CONTACTOR_OPEN_3

  • Request22 24 8E
  • Service 22DID 248E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Contactor open reason history 4 CADILLAC_CONTACTOR_OPEN_4

  • Request22 24 8F
  • Service 22DID 248F
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Contactor open reason history 5 CADILLAC_CONTACTOR_OPEN_5

  • Request22 24 90
  • Service 22DID 2490
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Contactor open reason history 6 CADILLAC_CONTACTOR_OPEN_6

  • Request22 24 91
  • Service 22DID 2491
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Contactor open reason history 7 CADILLAC_CONTACTOR_OPEN_7

  • Request22 24 92
  • Service 22DID 2492
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Contactor open reason history 8 CADILLAC_CONTACTOR_OPEN_8

  • Request22 24 93
  • Service 22DID 2493
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cooling fan command CADILLAC_COOLING_FAN_CMD

  • Request22 38 12
  • Service 22DID 3812
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2026.

Cooling fan command CADILLAC_COOLING_FAN_CMD_V2

  • Request22 38 12
  • Service 22DID 3812
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cooling fan motor command CADILLAC_COOLING_FAN_MOTOR_CMD

  • Request22 13 AF
  • Service 22DID 13AF
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2026.

Cooling fan motor command CADILLAC_COOLING_FAN_MOTOR_CMD_V2

  • Request22 13 AF
  • Service 22DID 13AF
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cooling fan, radiator motor, commanded CADILLAC_COOLING_FAN_RADIATOR_CMD

  • Request22 13 AF
  • Service 22DID 13AF
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Cruise control status CADILLAC_CRUISE_CTRL_STAT

  • Request22 20 67
  • Service 22DID 2067
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Diesel particulate filter, average filter inlet temperature during regeneration CADILLAC_DPF_AVG_FLT_INLET_T_DURING_REGENConfirmed

  • Request22 20 F8
  • Service 22DID 20F8
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Example reply from a 2022 Cadillac Escalade.

Bits 0 to 15 of the reply, 16 bits.

0x0190 = 400 → (400 ÷ 10 − 40) = 0 s

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 s
Unit
s

Confirmed for 2022. In testing for 1999 to 2021, 2023 to 2026.

Diesel particulate filter, average regeneration duration CADILLAC_DPF_AVG_REGEN_DURATION

  • Request22 20 F9
  • Service 22DID 20F9
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 2040 ÷ 65535)
Range
0 to 2040 s
Unit
s

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Diesel particulate filter, calculated flow resistance [kpa/(l/s)] CADILLAC_DPF_CALCULATED_FLOW_RESISTANCE_KPA_L_S

  • Request22 20 F5
  • Service 22DID 20F5
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 100)
Range
0 to 2.55
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Diesel particulate filter, corrected pressure CADILLAC_DPF_CORRECTED_PRESConfirmed

  • Request22 34 D9
  • Service 22DID 34D9
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Example reply from a 2022 Cadillac Escalade.

Bits 0 to 15 of the reply, 16 bits. The value is signed.

0x0000 = 0 → (0 × 100 ÷ 10000) = 0 kPa

Formula
(val × 100 ÷ 10000)
Range
-327.68 to 327.67 kPa
Unit
kPa

Confirmed for 2022. In testing for 1999 to 2021, 2023 to 2026.

Diesel particulate filter, engine run time since last regeneration CADILLAC_DPF_ENGINE_RUN_TIME_SINCE_LAST_REGEN_MINConfirmed

  • Request22 20 F3
  • Service 22DID 20F3
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Example reply from a 2022 Cadillac Escalade.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 × 8 ÷ 60) = 0 min

Formula
(val × 8 ÷ 60)
Range
0 to 8738 min
Unit
min

Confirmed for 2022. In testing for 1999 to 2021, 2023 to 2026.

Diesel particulate filter, exhaust gas temperature 1 CADILLAC_DPF_EGT_1Confirmed

  • Request22 30 3A
  • Service 22DID 303A
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Example reply from a 2022 Cadillac Escalade.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10 − 40) = -40 °C

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2022. In testing for 1999 to 2021, 2023 to 2026.

Diesel particulate filter, exhaust gas temperature 2 CADILLAC_DPF_EGT_2Confirmed

  • Request22 30 3B
  • Service 22DID 303B
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Example reply from a 2022 Cadillac Escalade.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10 − 40) = -40 °C

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2022. In testing for 1999 to 2021, 2023 to 2026.

Diesel particulate filter, exhaust gas temperature 3 CADILLAC_DPF_EGT_3

  • Request22 30 A9
  • Service 22DID 30A9
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Diesel particulate filter, exhaust gas temperature 4 CADILLAC_DPF_EGT_4Confirmed

  • Request22 00 78
  • Service 22DID 0078
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Example reply from a 2022 Cadillac Escalade.

Bits 56 to 71 of the reply, 16 bits.

0x0000 = 0 → (0 ÷ 10 − 40) = -40 °C

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

Confirmed for 2022. In testing for 1999 to 2021, 2023 to 2026.

Diesel particulate filter, exhaust gas temperature 5 CADILLAC_DPF_EGT_5

  • Request22 30 AB
  • Service 22DID 30AB
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 10 − 40)
Range
-40 to 6513.5 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Diesel particulate filter, number of completed regenerations CADILLAC_DPF_NUMBER_OF_COMPLETED_REGENSConfirmed

  • Request22 30 4B
  • Service 22DID 304B
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Example reply from a 2022 Cadillac Escalade.

Bits 0 to 15 of the reply, 16 bits.

0x0000 = 0 → 0

Formula
val
Range
0 to 65535
Unit
Number

Confirmed for 2022. In testing for 1999 to 2021, 2023 to 2026.

Diesel particulate filter, pressure CADILLAC_DPF_PRES

  • Request22 34 D8
  • Service 22DID 34D8
  • ModuleDA11
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100 ÷ 10000)
Range
-327.68 to 327.67 kPa
Unit
kPa

In testing for 1999 to 2003, 2005 to 2006, 2009 to 2016, 2019, 2021, 2023 to 2026. Not supported for 2004, 2007 to 2008, 2017 to 2018, 2020, 2022.

Diesel particulate filter, pressure sensor CADILLAC_DPF_PRES_SNS

  • Request22 30 35
  • Service 22DID 3035
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 65535)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Diesel particulate filter, regeneration reason CADILLAC_DPF_REGEN_REASON

  • Request22 30 3E
  • Service 22DID 303E
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Diesel particulate filter, regeneration status CADILLAC_DPF_REGEN_STS

  • Request22 33 75
  • Service 22DID 3375
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Electronics coolant pump speed CADILLAC_ELECTRONICS_CLT_PMP

  • Request22 43 58
  • Service 22DID 4358
  • Module7E4 → 7EC
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 rpm
Unit
rpm

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Electronics coolant pump, commanded CADILLAC_ELECTRONICS_CLT_PMP_CMD

  • Request22 43 57
  • Service 22DID 4357
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Electronics coolant temperature CADILLAC_ELECTRONICS_CLT_TEMP

  • Request22 1C 43
  • Service 22DID 1C43
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Engine coolant temperature ECTSAE J1979Confirmed

Your engine temperature must operate within a certain temperature range to operate efficiently and safely. If it runs too hot, then your engine could be permanently damaged. If it runs too cold, then your engine will use more fuel than necessary.

Pelican can show this parameter as the engine coolant temperature.

  • Request01 05
  • Service 01PID 05
  • Module7E0 → 7E8
  • Every500 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017 to 2018, 2022. Supported for 2007 to 2008, 2013, 2020, 2025.

Engine oil absolute pressure CADILLAC_EOP_ABS

  • Request22 23 44
  • Service 22DID 2344
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 400 ÷ 100)
Range
0 to 1020 kPa
Unit
kPa

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Engine oil absolute pressure CADILLAC_EOP_ABS_2

  • Request22 23 44
  • Service 22DID 2344
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 4)
Range
0 to 1020 kPa
Unit
kPa

In testing for 1999 to 2026.

Engine oil life remaining CADILLAC_EO_LIFE_REMAINING

  • Request22 4D C0
  • Service 22DID 4DC0
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2026.

Engine oil life remaining CADILLAC_EO_LIFE_REMAINING_V2

  • Request22 4D C0
  • Service 22DID 4DC0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Engine oil pressure CADILLAC_EOPConfirmed

  • Request22 14 70
  • Service 22DID 1470
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Example reply from a 2022 Cadillac Escalade.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 400 ÷ 100) = 0 kPa

Formula
(val × 400 ÷ 100)
Range
0 to 1020 kPa
Unit
kPa

Confirmed for 2022. In testing for 1999 to 2021, 2023 to 2026.

Engine oil pressure CADILLAC_EOP_ACT

  • Request22 23 45
  • Service 22DID 2345
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 4)
Range
0 to 1020 kPa
Unit
kPa

In testing for 1999 to 2026.

Engine oil pressure CADILLAC_EOP_DA11

  • Request22 14 70
  • Service 22DID 1470
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 400 ÷ 100)
Range
0 to 1020 kPa
Unit
kPa

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Engine oil pressure CADILLAC_EOP_V2

  • Request22 23 45
  • Service 22DID 2345
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 400 ÷ 100)
Range
0 to 1020 kPa
Unit
kPa

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Engine oil pressure 2 CADILLAC_EOP_2

Reads 0 psi at the sensor's zero-pressure floor, raw 36; the 0.6 psi slope is not yet checked against a gauge.

  • Request22 11 5C
  • Service 22DID 115C
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 5 − 21.6)
Range
-21.6 to 131.39 psi
Unit
psi

In testing for 1999 to 2026.

Engine oil pressure 2 CADILLAC_EOP_2_V2

Reads 0 psi at the sensor's zero-pressure floor, raw 36; the 0.6 psi slope is not yet checked against a gauge.

  • Request22 11 5C
  • Service 22DID 115C
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3 ÷ 5 − 21.6)
Range
-21.6 to 131.39 psi
Unit
psi

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Engine oil pressure control solenoid valve command CADILLAC_EOP_CTRL_SOLENOID_VALVE_CMD

  • Request22 33 18
  • Service 22DID 3318
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2026.

Engine oil pressure control solenoid valve command CADILLAC_EOP_CTRL_SOLENOID_VALVE_CMD_V2

  • Request22 33 18
  • Service 22DID 3318
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
Off or on

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Engine oil pressure, actual CADILLAC_EOP_ACT_V2

  • Request22 23 45
  • Service 22DID 2345
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 4)
Range
0 to 1020 kPa
Unit
kPa

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Engine oil pressure, desired CADILLAC_EOP_DES

  • Request22 37 A7
  • Service 22DID 37A7
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 4)
Range
0 to 1020 kPa
Unit
kPa

In testing for 1999 to 2026.

Engine oil temperature CADILLAC_EOTConfirmed

Pelican can show this parameter as the engine oil temperature.

  • Request22 00 5C
  • Service 22DID 005C
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Example reply from a 2022 Cadillac Escalade.

Bits 0 to 7 of the reply, 8 bits.

0x63 = 99 → (99 − 40) = 59 °C

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2022. In testing for 1999 to 2021, 2023 to 2026.

Engine oil temperature CADILLAC_EOT_2

  • Request22 15 3E
  • Service 22DID 153E
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
0 to 215 °C
Unit
°C

In testing for 1999 to 2026.

Engine oil temperature CADILLAC_EOT_ALT

Pelican can show this parameter as the engine oil temperature.

  • Request22 15 3E
  • Service 22DID 153E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
0 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Engine oil temperature CADILLAC_EOT_DA11

  • Request22 15 3E
  • Service 22DID 153E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
0 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Engine oil temperature CADILLAC_EOT_V2

Pelican can show this parameter as the engine oil temperature.

  • Request22 15 3E
  • Service 22DID 153E
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
0 to 215 °C
Unit
°C

In testing for 1999 to 2026.

Engine oil temperature CADILLAC_EOT_V3

Pelican can show this parameter as the engine oil temperature.

  • Request22 00 5C
  • Service 22DID 005C
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Engine oil temperature 2 CADILLAC_EOT_2_V2

  • Request22 15 3E
  • Service 22DID 153E
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2026.

Engine RPM RPMSAE J1979Confirmed

  • Request01 0C
  • Service 01PID 0C
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383.75 rpm
Unit
rpm

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

Engine torque CADILLAC_ENG_TQ

  • Request22 19 DE
  • Service 22DID 19DE
  • ModuleDA11 → 2AF111
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1999 to 2026.

Engine torque CADILLAC_ENG_TQ_2

  • Request22 20 3F
  • Service 22DID 203F
  • ModuleDA11 → 2AF111
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383 N·m
Unit
N·m

In testing for 1999 to 2026.

Engine torque CADILLAC_ENG_TQ_7E0

  • Request22 20 3F
  • Service 22DID 203F
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 4)
Range
0 to 16383 N·m
Unit
N·m

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Engine torque CADILLAC_ENG_TQ_V2

  • Request22 19 DE
  • Service 22DID 19DE
  • Module7E0 → 7E8
  • Every250 ms
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 N·m
Unit
N·m

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

EV trip this drive cycle CADILLAC_EV_TRIP_THIS_DRIVE

  • Request22 24 87
  • Service 22DID 2487
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 100)
Range
-327 to 327 km
Unit
km

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Evap system vapor pressure EVAP_VPSAE J1979Confirmed

The pressure signal is normally obtained from a sensor located in the fuel tank or a sensor in an evaporative system vapor line.

  • Request01 32
  • Service 01PID 32
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 4000)
Range
-8192 to 8191.75 kPa
Unit
kPa

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

Evaporative emissions purge CADILLAC_EVAPORATIVE

  • Request22 11 70
  • Service 22DID 1170
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2026.

Evaporative emissions purge CADILLAC_EVAPORATIVE_V2

  • Request22 11 70
  • Service 22DID 1170
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Exhaust gas recirculation duty cycle CADILLAC_EGR_DUTY

  • Request22 11 71
  • Service 22DID 1171
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2026.

Exhaust gas recirculation duty cycle CADILLAC_EGR_DUTY_V2

  • Request22 11 71
  • Service 22DID 1171
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2.55)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Exhaust gas recirculation voltage CADILLAC_EGR_V

  • Request22 11 4B
  • Service 22DID 114B
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 51)
Range
0 to 5 V
Unit
V

In testing for 1999 to 2026.

Exhaust gas recirculation voltage CADILLAC_EGR_V_V2

  • Request22 11 4B
  • Service 22DID 114B
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 51)
Range
0 to 5 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Fuel pressure FPSAE J1979Confirmed

  • Request01 0A
  • Service 01PID 0A
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 3)
Range
0 to 765 kPa
Unit
kPa

Confirmed for 2017. Supported for 2008, 2013, 2018, 2020, 2022, 2025.

Fuel rail pressure FRPSAE J1979Confirmed

Fuel rail pressure at the engine when the reading is referenced to atmosphere (gage pressure).

  • Request01 23
  • Service 01PID 23
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 10)
Range
0 to 655350 kPa
Unit
kPa

Confirmed for 2017. Supported for 2018, 2020, 2022, 2025.

H2 electronics temperature CADILLAC_H2_ELECTRONICS_T

  • Request22 1C 43
  • Service 22DID 1C43
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Heated oxygen sensor CADILLAC_HEATED_OXYGEN_SENS

  • Request22 11 45
  • Service 22DID 1145
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mV
Unit
mV

In testing for 1999 to 2026.

Heated oxygen sensor CADILLAC_HEATED_OXYGEN_SENS_V2

  • Request22 11 45
  • Service 22DID 1145
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mV
Unit
mV

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

High voltage actively tested vehicle isolation resistance CADILLAC_HIGH_V_ACTIVELY

  • Request22 41 EC
  • Service 22DID 41EC
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535 Ω
Unit
Ω

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

High voltage circuit, hybrid powertrain control module CADILLAC_HIGH_V_CIRCUIT_HPCM

  • Request22 1C 24
  • Service 22DID 1C24
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

High voltage current CADILLAC_HIGH_V_CURRENT

  • Request22 43 56
  • Service 22DID 4356
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × -40 ÷ 267)
Range
-4908 to 4909 A
Unit
A

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

High voltage current HD CADILLAC_HIGH_V_CURRENT_HD

  • Request22 24 14
  • Service 22DID 2414
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 20)
Range
-1638 to 1638 A
Unit
A

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

High voltage current HD CADILLAC_HIGH_V_CURRENT_HD_V2

  • Request22 43 56
  • Service 22DID 4356
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × -500 ÷ 3333)
Range
-4915 to 4915 A
Unit
A

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

High voltage inverter voltage HD CADILLAC_HIGH_V_INVERTER_V_HD

  • Request22 41 C4
  • Service 22DID 41C4
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 40)
Range
0 to 1638 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

High voltage inverter voltage LD CADILLAC_HIGH_V_INVERTER_V_LD

  • Request22 41 DA
  • Service 22DID 41DA
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 13 ÷ 25)
Range
0 to 34078 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

High voltage isolation test resistance CADILLAC_HIGH_V_ISOLATION

  • Request22 43 A6
  • Service 22DID 43A6
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 25)
Range
0 to 6375 kΩ
Unit
kΩ

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

High voltage MG voltage CADILLAC_HIGH_V_MG_V

  • Request22 28 85
  • Service 22DID 2885
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

High voltage system interlock circuit CADILLAC_HIGH_V_SYSTEM

  • Request22 43 10
  • Service 22DID 4310
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

High voltage system interlock circuit status CADILLAC_HIGH_V_SYSTEM_INTERLOCK

  • Request22 43 11
  • Service 22DID 4311
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Highest voltage cell number CADILLAC_BAT_CELL_MAX

  • Request22 43 2C
  • Service 22DID 432C
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Idle air control position CADILLAC_IDLE_AIR_CTRL_POS

  • Request22 11 72
  • Service 22DID 1172
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2026.

Idle air control position CADILLAC_IDLE_AIR_CTRL_POS_V2

  • Request22 11 72
  • Service 22DID 1172
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Ignition input on/off/start CADILLAC_IGN_INPUT_ON_OFF

  • Request22 20 D0
  • Service 22DID 20D0
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Ignition input on/off/start CADILLAC_IGN_INPUT_ON_OFF_V2

  • Request22 20 D0
  • Service 22DID 20D0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Ignition power mode CADILLAC_IGN_POWER_MODE

  • Request22 20 7E
  • Service 22DID 207E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Ignition power mode CADILLAC_IGN_POWER_MODE_V2

  • Request22 20 7E
  • Service 22DID 207E
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Ignition power mode, battery energy control module CADILLAC_IGN_POWER_MODE_BECM

  • Request22 80 02
  • Service 22DID 8002
  • Module7E7 → 7EF
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Ignition voltage CADILLAC_IGN_V

  • Request22 11 41
  • Service 22DID 1141
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Ignition voltage CADILLAC_IGN_V_V2

  • Request22 11 41
  • Service 22DID 1141
  • Module7E2 → 7EA
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 10)
Range
0 to 25.5 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Injector duty cycle bank 1 CADILLAC_INJECTOR_DUTY_CYCLE_BANK_1

  • Request22 12 C3
  • Service 22DID 12C3
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 150 ÷ 10000)
Range
0 to 983.025 ms
Unit
ms

In testing for 1999 to 2026.

Injector duty cycle bank 1 CADILLAC_INJECTOR_DUTY_CYCLE_BANK_1_V2

  • Request22 12 C3
  • Service 22DID 12C3
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 150 ÷ 10000)
Range
0 to 983.025 ms
Unit
ms

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Injector duty cycle bank 2 CADILLAC_INJECTOR_DUTY_CYCLE_BANK_2

  • Request22 12 C4
  • Service 22DID 12C4
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 150 ÷ 10000)
Range
0 to 983.025 ms
Unit
ms

In testing for 1999 to 2026.

Injector duty cycle bank 2 CADILLAC_INJECTOR_DUTY_CYCLE_BANK_2_V2

  • Request22 12 C4
  • Service 22DID 12C4
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 150 ÷ 10000)
Range
0 to 983.025 ms
Unit
ms

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Injector pulse width, cylinder 1 CADILLAC_INJ_WIDTH_CYL_1

  • Request22 11 93
  • Service 22DID 1193
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 65.535)
Range
0 to 1000 ms
Unit
ms

In testing for 1999 to 2026.

Injector pulse width, cylinder 1 CADILLAC_INJ_WIDTH_CYL_1_V2

  • Request22 11 93
  • Service 22DID 1193
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 65.535)
Range
0 to 1000 ms
Unit
ms

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Injector pulse width, cylinder 7 CADILLAC_INJ_WIDTH_CYL_7

  • Request22 11 99
  • Service 22DID 1199
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 65.535)
Range
0 to 1000 ms
Unit
ms

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Injector pulse width, cylinder 8 CADILLAC_INJ_WIDTH_CYL_8

  • Request22 12 9A
  • Service 22DID 129A
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 65.535)
Range
0 to 1000 ms
Unit
ms

In testing for 1999 to 2026.

Injector pulse width, cylinder 8 CADILLAC_INJ_WIDTH_CYL_8_V2

  • Request22 12 9A
  • Service 22DID 129A
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 65.535)
Range
0 to 1000 ms
Unit
ms

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Intake air temperature IATSAE J1979Confirmed

  • Request01 0F
  • Service 01PID 0F
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

Intake air temperature 2 CADILLAC_IAT_2

  • Request22 15 38
  • Service 22DID 1538
  • ModuleDA11 → 2AF111
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2026.

Intake air temperature 2 CADILLAC_IAT_2_V2

  • Request22 15 38
  • Service 22DID 1538
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Intake air temperature, bank 1, sensor 1 IAT_11SAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 8 to 15 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017.

Intake air temperature, bank 1, sensor 2 IAT_12SAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 16 to 23 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017.

Intake air temperature, bank 1, sensor 3 IAT_13SAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 24 to 31 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017.

Intake air temperature, bank 2, sensor 1 IAT_21SAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 32 to 39 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017.

Intake air temperature, bank 2, sensor 2 IAT_22SAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 40 to 47 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017.

Intake air temperature, bank 2, sensor 3 IAT_23SAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bits 48 to 55 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

Confirmed for 2017.

Intake manifold absolute pressure MAPSAE J1979Confirmed

  • Request01 0B
  • Service 01PID 0B
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 kPa
Unit
kPa

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020.

Internal mode switch 1 CADILLAC_INTERNAL_MODE_SWITCH_1

  • Request22 33 C3
  • Service 22DID 33C3
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Internal mode switch 2 CADILLAC_INTERNAL_MODE_SWITCH_2

  • Request22 33 C4
  • Service 22DID 33C4
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Internal mode switch 3 CADILLAC_INTERNAL_MODE_SWITCH_3

  • Request22 33 C5
  • Service 22DID 33C5
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Internal mode switch 4 CADILLAC_INTERNAL_MODE_SWITCH_4

  • Request22 33 C6
  • Service 22DID 33C6
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Internal mode switch 5 CADILLAC_INTERNAL_MODE_SWITCH_5

  • Request22 33 C7
  • Service 22DID 33C7
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Internal mode switch 6 CADILLAC_INTERNAL_MODE_SWITCH_6

  • Request22 33 C8
  • Service 22DID 33C8
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Internal mode switch 7 CADILLAC_INTERNAL_MODE_SWITCH_7

  • Request22 33 C9
  • Service 22DID 33C9
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Internal mode switch 8 CADILLAC_INTERNAL_MODE_SWITCH_8

  • Request22 33 CA
  • Service 22DID 33CA
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Internal mode switch 9 CADILLAC_INTERNAL_MODE_SWITCH_9

  • Request22 33 CB
  • Service 22DID 33CB
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Internal mode switch 10 CADILLAC_INTERNAL_MODE_SWITCH_10

  • Request22 33 CC
  • Service 22DID 33CC
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Internal mode switch 11 CADILLAC_INTERNAL_MODE_SWITCH_11

  • Request22 33 CD
  • Service 22DID 33CD
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Knock retard CADILLAC_KNOCK_RETARD

  • Request22 11 A6
  • Service 22DID 11A6
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 22 ÷ 100)
Range
0 to 56.1 °
Unit
°

In testing for 1999 to 2026.

Knock retard CADILLAC_KNOCK_RETARD_V2

  • Request22 11 A6
  • Service 22DID 11A6
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 22 ÷ 100)
Range
0 to 56.1 °
Unit
°

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Knock retard, alternate CADILLAC_KNOCK_RETARD_ALT

  • Request22 12 5D
  • Service 22DID 125D
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 1999 to 2026.

Knock retard, alternate CADILLAC_KNOCK_RETARD_ALT_V2

  • Request22 12 5D
  • Service 22DID 125D
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 °
Unit
°

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Knock sensor active counter CADILLAC_KNOCK_SENS_ACTIVE

  • Request22 12 5E
  • Service 22DID 125E
  • ModuleDA11 → 2AF111
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2026.

Knock sensor active counter CADILLAC_KNOCK_SENS_ACTIVE_V2

  • Request22 12 5E
  • Service 22DID 125E
  • Module7E0 → 7E8
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Last shift time CADILLAC_LAST_SHIFT_TIME

  • Request22 19 92
  • Service 22DID 1992
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1999 to 2026.

Last shift time CADILLAC_LAST_SHIFT_TIME_V2

  • Request22 19 92
  • Service 22DID 1992
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 40)
Range
0 to 6.375 s
Unit
s

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Long term fuel trim (bank 1) LONGFT1SAE J1979Confirmed

  • Request01 07
  • Service 01PID 07
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

Long term fuel trim (bank 2) LONGFT2SAE J1979Confirmed

  • Request01 09
  • Service 01PID 09
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

Lowest voltage cell number CADILLAC_BAT_CELL_MIN

  • Request22 43 2A
  • Service 22DID 432A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Mass airflow sensor CADILLAC_MAF

Pelican can show this parameter as the mass air flow.

  • Request22 00 10
  • Service 22DID 0010
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 10000)
Range
0 to 655.35 g/s
Unit
g/s

In testing for 1999 to 2026.

Mass airflow sensor CADILLAC_MAF_7E0

  • Request22 00 10
  • Service 22DID 0010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 10000)
Range
0 to 655.35 g/s
Unit
g/s

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Mass airflow sensor CADILLAC_MAF_DA11

  • Request22 00 10
  • Service 22DID 0010
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 10000)
Range
0 to 655.35 g/s
Unit
g/s

In testing for 1999 to 2026.

Mass airflow sensor CADILLAC_MAF_V2

Pelican can show this parameter as the mass air flow.

  • Request22 00 10
  • Service 22DID 0010
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 10000)
Range
0 to 655.35 g/s
Unit
g/s

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

MIL cause CADILLAC_MIL_CAUSE

  • Request22 13 5F
  • Service 22DID 135F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

MIL status CADILLAC_MIL_STAT

  • Request22 20 20
  • Service 22DID 2020
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfire current, cylinder 7 CADILLAC_MIS_CURRENT_7

  • Request22 11 EC
  • Service 22DID 11EC
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfire current, cylinder 8 CADILLAC_MIS_CURRENT_8

  • Request22 11 ED
  • Service 22DID 11ED
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfire history, cylinder 1 CADILLAC_MIS_HISTORY_1

  • Request22 12 01
  • Service 22DID 1201
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2026.

Misfire history, cylinder 1 CADILLAC_MIS_HISTORY_1_V2

  • Request22 12 01
  • Service 22DID 1201
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfire history, cylinder 2 CADILLAC_MIS_HISTORY_2

  • Request22 12 02
  • Service 22DID 1202
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2026.

Misfire history, cylinder 2 CADILLAC_MIS_HISTORY_2_V2

  • Request22 12 02
  • Service 22DID 1202
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfire history, cylinder 3 CADILLAC_MIS_HISTORY_3

  • Request22 12 03
  • Service 22DID 1203
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2026.

Misfire history, cylinder 3 CADILLAC_MIS_HISTORY_3_V2

  • Request22 12 03
  • Service 22DID 1203
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfire history, cylinder 4 CADILLAC_MIS_HISTORY_4

  • Request22 12 04
  • Service 22DID 1204
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2026.

Misfire history, cylinder 4 CADILLAC_MIS_HISTORY_4_V2

  • Request22 12 04
  • Service 22DID 1204
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfire history, cylinder 5 CADILLAC_MIS_HISTORY_5

  • Request22 11 F8
  • Service 22DID 11F8
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2026.

Misfire history, cylinder 5 CADILLAC_MIS_HISTORY_5_V2

  • Request22 11 F8
  • Service 22DID 11F8
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfire history, cylinder 6 CADILLAC_MIS_HISTORY_6

  • Request22 11 F9
  • Service 22DID 11F9
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2026.

Misfire history, cylinder 6 CADILLAC_MIS_HISTORY_6_V2

  • Request22 11 F9
  • Service 22DID 11F9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfire history, cylinder 7 CADILLAC_MIS_HISTORY_7

  • Request22 11 FA
  • Service 22DID 11FA
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2026.

Misfire history, cylinder 7 CADILLAC_MIS_HISTORY_7_V2

  • Request22 11 FA
  • Service 22DID 11FA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfire history, cylinder 8 CADILLAC_MIS_HISTORY_8

  • Request22 11 FB
  • Service 22DID 11FB
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2026.

Misfire history, cylinder 8 CADILLAC_MIS_HISTORY_8_V2

  • Request22 11 FB
  • Service 22DID 11FB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
val
Range
0 to 65535
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfires, current, cylinder 1 CADILLAC_MISFIRES_C1_CUR

  • Request22 12 06
  • Service 22DID 1206
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2026.

Misfires, current, cylinder 1 CADILLAC_MISFIRES_C1_CUR_V2

  • Request22 12 06
  • Service 22DID 1206
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfires, current, cylinder 2 CADILLAC_MISFIRES_C2_CUR

  • Request22 12 05
  • Service 22DID 1205
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2026.

Misfires, current, cylinder 2 CADILLAC_MISFIRES_C2_CUR_V2

  • Request22 12 05
  • Service 22DID 1205
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfires, current, cylinder 3 CADILLAC_MISFIRES_C3_CUR

  • Request22 12 07
  • Service 22DID 1207
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2026.

Misfires, current, cylinder 3 CADILLAC_MISFIRES_C3_CUR_V2

  • Request22 12 07
  • Service 22DID 1207
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfires, current, cylinder 4 CADILLAC_MISFIRES_C4_CUR

  • Request22 12 08
  • Service 22DID 1208
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2026.

Misfires, current, cylinder 4 CADILLAC_MISFIRES_C4_CUR_V2

  • Request22 12 08
  • Service 22DID 1208
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfires, current, cylinder 5 CADILLAC_MISFIRES_C5_CUR

  • Request22 11 EA
  • Service 22DID 11EA
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2026.

Misfires, current, cylinder 5 CADILLAC_MISFIRES_C5_CUR_V2

  • Request22 11 EA
  • Service 22DID 11EA
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfires, current, cylinder 6 CADILLAC_MISFIRES_C6_CUR

  • Request22 11 EB
  • Service 22DID 11EB
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2026.

Misfires, current, cylinder 6 CADILLAC_MISFIRES_C6_CUR_V2

  • Request22 11 EB
  • Service 22DID 11EB
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Misfires, current, cylinder 7 CADILLAC_MISFIRES_C7_CURConfirmed

  • Request22 11 EC
  • Service 22DID 11EC
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Example reply from a 2022 Cadillac Escalade.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 100 ÷ 255) = 0 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2022. In testing for 1999 to 2021, 2023 to 2026.

Misfires, current, cylinder 8 CADILLAC_MISFIRES_C8_CURConfirmed

  • Request22 11 ED
  • Service 22DID 11ED
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Example reply from a 2022 Cadillac Escalade.

Bits 0 to 7 of the reply, 8 bits.

0x00 = 0 → (0 × 100 ÷ 255) = 0 %

Formula
(val × 100 ÷ 255)
Range
0 to 100 %
Unit
%

Confirmed for 2022. In testing for 1999 to 2021, 2023 to 2026.

Motor control module negative supply isolation voltage CADILLAC_MOTOR_CTRL_MODULE_NEGATIVE_V

  • Request22 44 1A
  • Service 22DID 441A
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 13 ÷ 100)
Range
0 to 8519 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Motor control module positive supply isolation voltage CADILLAC_MOTOR_CTRL_MODULE_V

  • Request22 44 19
  • Service 22DID 4419
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 13 ÷ 100)
Range
0 to 8519 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Motor controller negative isolation voltage CADILLAC_MOTOR_CONTROLLER_ISOLATION_V

  • Request22 28 D0
  • Service 22DID 28D0
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Motor controller positive isolation voltage CADILLAC_MOTOR_CONTROLLER_V

  • Request22 28 CF
  • Service 22DID 28CF
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val ÷ 100)
Range
0 to 655 V
Unit
V

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Motor inverter active CADILLAC_MOTOR_INVERTER

  • Request22 28 81
  • Service 22DID 2881
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Motor inverter temperature sensor 1 CADILLAC_MOTOR_INVERTER_T_1

  • Request22 1C 26
  • Service 22DID 1C26
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Motor inverter temperature sensor 2 CADILLAC_MOTOR_INVERTER_T_2

  • Request22 1C 28
  • Service 22DID 1C28
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Motor inverter temperature sensor 3 CADILLAC_MOTOR_INVERTER_T_3

  • Request22 1C 2A
  • Service 22DID 1C2A
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Motor phase U current CADILLAC_MOTOR_PHASE_U

  • Request22 28 DE
  • Service 22DID 28DE
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 25)
Range
-1310 to 1310 A
Unit
A

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Motor phase V current CADILLAC_MOTOR_PHASE_V

  • Request22 28 E1
  • Service 22DID 28E1
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 25)
Range
-1310 to 1310 A
Unit
A

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Motor phase W current CADILLAC_MOTOR_PHASE_W

  • Request22 28 E4
  • Service 22DID 28E4
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 25)
Range
-1310 to 1310 A
Unit
A

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Motor position sensor offset learn status CADILLAC_MOTOR_POS_SENS

  • Request22 28 CD
  • Service 22DID 28CD
  • Module7E1 → 7E9
  • Every3600 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Motor temperature CADILLAC_MOTOR_T

  • Request22 28 CB
  • Service 22DID 28CB
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Motor-generator A current CADILLAC_MGA_CURRENT

  • Request22 28 83
  • Service 22DID 2883
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 A
Unit
A

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Motor-generator B current CADILLAC_MGB_CURRENT

  • Request22 28 84
  • Service 22DID 2884
  • Module7E1 → 7E9
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val ÷ 10)
Range
-3276 to 3276 A
Unit
A

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal disengage history 1 CADILLAC_ONE_PEDAL_DISENGAGE_1

  • Request22 36 EE
  • Service 22DID 36EE
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal disengage history 2 CADILLAC_ONE_PEDAL_DISENGAGE_2

  • Request22 36 EF
  • Service 22DID 36EF
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal disengage history 3 CADILLAC_ONE_PEDAL_DISENGAGE_3

  • Request22 36 F0
  • Service 22DID 36F0
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal disengage history 4 CADILLAC_ONE_PEDAL_DISENGAGE_4

  • Request22 36 F1
  • Service 22DID 36F1
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal disengage history 5 CADILLAC_ONE_PEDAL_DISENGAGE_5

  • Request22 36 F2
  • Service 22DID 36F2
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal disengage history 6 CADILLAC_ONE_PEDAL_DISENGAGE_6

  • Request22 36 F3
  • Service 22DID 36F3
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal disengage history 7 CADILLAC_ONE_PEDAL_DISENGAGE_7

  • Request22 36 F4
  • Service 22DID 36F4
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal disengage history 8 CADILLAC_ONE_PEDAL_DISENGAGE_8

  • Request22 36 F5
  • Service 22DID 36F5
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal driving inhibit history 1 CADILLAC_ONE_PEDAL_DRIVING_1

  • Request22 36 F6
  • Service 22DID 36F6
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal driving inhibit history 2 CADILLAC_ONE_PEDAL_DRIVING_2

  • Request22 36 F7
  • Service 22DID 36F7
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal driving inhibit history 3 CADILLAC_ONE_PEDAL_DRIVING_3

  • Request22 36 F8
  • Service 22DID 36F8
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal driving inhibit history 4 CADILLAC_ONE_PEDAL_DRIVING_4

  • Request22 36 F9
  • Service 22DID 36F9
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal driving inhibit history 5 CADILLAC_ONE_PEDAL_DRIVING_5

  • Request22 36 FA
  • Service 22DID 36FA
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal driving inhibit history 6 CADILLAC_ONE_PEDAL_DRIVING_6

  • Request22 36 FB
  • Service 22DID 36FB
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal driving inhibit history 7 CADILLAC_ONE_PEDAL_DRIVING_7

  • Request22 36 FC
  • Service 22DID 36FC
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

One pedal driving inhibit history 8 CADILLAC_ONE_PEDAL_DRIVING_8

  • Request22 36 FD
  • Service 22DID 36FD
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Outside air temperature CADILLAC_AAT

  • Request22 11 61
  • Service 22DID 1161
  • ModuleDA11 → 2AF111
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2026.

Outside air temperature CADILLAC_AAT_V2

  • Request22 11 61
  • Service 22DID 1161
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Particulate filter pressure CADILLAC_DPF_PRESS

  • Request22 34 D8
  • Service 22DID 34D8
  • ModuleDA11
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 100 ÷ 10000)
Range
0 to 655.35 kPa
Unit
kPa

In testing for 1999 to 2003, 2005 to 2006, 2009 to 2016, 2019, 2021, 2023 to 2026. Not supported for 2004, 2007 to 2008, 2017 to 2018, 2020, 2022.

Particulate matter sensor soot accumulation CADILLAC_PARTICULATE_MATTER_SNS_SOOT_ACCUMULATION

  • Request22 36 35
  • Service 22DID 3635
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100 ÷ 10000)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Particulate matter sensor soot accumulation CADILLAC_PARTICULATE_MATTER_SNS_SOOT_ACCUMULATION_V2

  • Request22 36 35
  • Service 22DID 3635
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits. The value is signed.

Formula
(val × 100 ÷ 10000)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Particulate matter sensor temperature CADILLAC_PARTICULATE_MATTER_SNS_T

  • Request22 33 72
  • Service 22DID 3372
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1000 ÷ 10000)
Range
0 to 6553.5 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Particulate matter sensor temperature CADILLAC_PARTICULATE_MATTER_SNS_T_V2

  • Request22 33 72
  • Service 22DID 3372
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 15 of the reply, 16 bits.

Formula
(val × 1000 ÷ 10000)
Range
0 to 6553.5 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Pressure control solenoid current, actual CADILLAC_P_CTRL_SOLENOID_ACT

  • Request22 19 9E
  • Service 22DID 199E
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1999 to 2026.

Pressure control solenoid current, actual CADILLAC_P_CTRL_SOLENOID_ACT_V2

  • Request22 19 9E
  • Service 22DID 199E
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Pressure control solenoid current, reference CADILLAC_P_CTRL_SOLENOID

  • Request22 19 9F
  • Service 22DID 199F
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1999 to 2026.

Pressure control solenoid current, reference CADILLAC_P_CTRL_SOLENOID_V2

  • Request22 19 9F
  • Service 22DID 199F
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 mA
Unit
mA

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Regen braking axle torque predicted CADILLAC_REGEN_BRAKING_AXLE_TQ

  • Request22 24 2B
  • Service 22DID 242B
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Regen braking axle torque request CADILLAC_REGEN_BRAKING_AXLE

  • Request22 24 26
  • Service 22DID 2426
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Remaining oil life CADILLAC_REMAINING_OIL_LIFE

  • Request22 11 9F
  • Service 22DID 119F
  • ModuleDA11 → 2AF111
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1999 to 2026.

Remaining oil life CADILLAC_REMAINING_OIL_LIFE_V2

  • Request22 11 9F
  • Service 22DID 119F
  • Module7E0 → 7E8
  • Every30 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Short term fuel trim (bank 1) SHRTFT1SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 06
  • Service 01PID 06
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2017, 2022. Supported for 2007 to 2008, 2013, 2018, 2020, 2025.

Short term fuel trim (bank 2) SHRTFT2SAE J1979Confirmed

Correction being used by the closed-loop fuel algorithm.

Pelican can show this parameter as the short term fuel trim.

  • Request01 08
  • Service 01PID 08
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 100)
Range
-100 to 99.2 %
Unit
%

Confirmed for 2017, 2022. Supported for 2007 to 2008, 2013, 2018, 2020, 2025.

Throttle position calculated CADILLAC_THROTTLE_POS_CALC

  • Request22 28 10
  • Service 22DID 2810
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Throttle position calculated CADILLAC_THROTTLE_POS_CALC_V2

  • Request22 28 10
  • Service 22DID 2810
  • Module7E1 → 7E9
  • Every250 ms
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 20 ÷ 51)
Range
0 to 100 %
Unit
%

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Timing advance SPARKADVSAE J1979Confirmed

Ignition timing spark advance for the first cylinder. Measured in degrees before dead center. Minus is degrees before dead center, positive is degrees after.

  • Request01 0E
  • Service 01PID 0E
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 2 − 64)
Range
-64 to 63.5 °
Unit
°

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

Total knock retard CADILLAC_TOTAL_KNOCK_RETARD

  • Request22 12 D9
  • Service 22DID 12D9
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 45 ÷ 100)
Range
0 to 114.75 °
Unit
°

In testing for 1999 to 2026.

Total knock retard CADILLAC_TOTAL_KNOCK_RETARD_V2

  • Request22 12 D9
  • Service 22DID 12D9
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val × 45 ÷ 100)
Range
0 to 114.75 °
Unit
°

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Total misfire CADILLAC_TOTAL_MISFIRE

  • Request22 12 00
  • Service 22DID 1200
  • ModuleDA11 → 2AF111
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2026.

Total misfire CADILLAC_TOTAL_MISFIRE_V2

  • Request22 12 00
  • Service 22DID 1200
  • Module7E0 → 7E8
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
val
Range
0 to 255
Unit
Number

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, variant 1 CADILLAC_ATF_T_VAR_1

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 19 40
  • Service 22DID 1940
  • ModuleDA11 → 2AF111
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2026.

Transmission fluid temperature, variant 1 CADILLAC_ATF_T_VAR_1_V2

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 19 40
  • Service 22DID 1940
  • Module7E0 → 7E8
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, variant 3 CADILLAC_ATF_T_VAR_3

  • Request22 19 40
  • Service 22DID 1940
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, variant 5 CADILLAC_ATF_T_VAR_5

  • Request22 19 40
  • Service 22DID 1940
  • Module7E4 → 7EC
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, variant 6 CADILLAC_ATF_T_VAR_6

  • Request22 28 0D
  • Service 22DID 280D
  • Module7E2 → 7EA
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, variant 6 CADILLAC_ATF_T_VAR_8

Pelican can show this parameter as the transmission fluid temperature.

  • Request22 28 0D
  • Service 22DID 280D
  • ModuleDA18 → 2AF118
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2026.

Transmission fluid temperature, variant 7 CADILLAC_ATF_T_VAR_7

  • Request22 28 0D
  • Service 22DID 280D
  • Module7E3 → 7EB
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Transmission fluid temperature, variant 8 CADILLAC_ATF_T_VAR_8_V2

  • Request22 28 0D
  • Service 22DID 280D
  • Module7E1 → 7E9
  • Every5 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val − 40)
Range
-40 to 215 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Type of fuel currently being used by the vehicle FUEL_TYPSAE J1979Confirmed

  • Request01 51
  • Service 01PID 51
  • Module7E0 → 7E8
  • Every250 ms

Bits 0 to 7 of the reply, 8 bits.

Unit
Named states
States
Raw valueStateMeaning
1GASGasoline/petrol
2METHMethanol
3ETHEthanol
4DSLDiesel
5LPGLiquefied petroleum gas
6CNGCompressed natural gas
7PROPPropane
8ELECBattery/electric
9BI_GASBi-fuel vehicle using gasoline/petrol
10BI_METHBi-fuel vehicle using methanol
11BI_ETHBi-fuel vehicle using ethanol
12BI_LPGBi-fuel vehicle using LPG
13BI_CNGBi-fuel vehicle using CNG
14BI_PROPBi-fuel vehicle using propane
15BI_ELECBi-fuel vehicle using battery
16BI_MIXBi-fuel vehicle using battery and combustion engine for propulsion
17HYB_GASHybrid vehicle using gasoline engine for propulsion
18HYB_ETHHybrid vehicle using gasoline engine on ethanol for propulsion
19HYB_DSLHybrid vehicle using diesel engine for propulsion
20HYB_ELECHybrid vehicle using battery for propulsion
21HYB_MIXHybrid vehicle using battery and combustion engine for propulsion
22HYB_REGHybrid vehicle in regeneration mode
23BI_DSLBi-fuel vehicle using diesel
24BI_NGBi-fuel vehicle using natural gas
25BI_DSLBi-fuel vehicle using diesel
26NGNatural gas
27DSL_CNGDual fuel vehicle using diesel and CNG
28DSL_LNGDual fuel vehicle using diesel and LNG
29FC_H2Fuel cell utilizing hydrogen
30HICE_HHOHydrogen Internal Combustion Engine
31KEROKerosene
32HFOHeavy Fuel Oil

Confirmed for 2017. Supported for 2025.

Vent temperature CADILLAC_VENT_T

  • Request22 82 B2
  • Service 22DID 82B2
  • Module7E4 → 7EC
  • Every1 s
  • Testing

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 8 − 10)
Range
-10 to 21.87 °C
Unit
°C

In testing for 1999 to 2021, 2023 to 2026. Not supported for 2022.

Engine › Internal

IAT Bank 1, Sensor 1 supported IAT_11_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017.

IAT Bank 1, Sensor 1 supported IAT_21_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017.

IAT Bank 1, Sensor 2 supported IAT_12_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017.

IAT Bank 1, Sensor 3 supported IAT_13_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017.

IAT Bank 2, Sensor 2 supported IAT_22_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017.

IAT Bank 2, Sensor 3 supported IAT_23_SUPSAE J1979Confirmed

  • Request01 68
  • Service 01PID 68
  • Module7E0 → 7E8
  • Every250 ms

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017.

Engine › OxygenSensors

02S Bank 1, Sensor 1 present O2S11_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 7 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

02S Bank 1, Sensor 2 present O2S12_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 6 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

02S Bank 1, Sensor 3 present O2S13_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 5 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

02S Bank 1, Sensor 4 present O2S14_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 4 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

02S Bank 2, Sensor 1 present O2S21_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 3 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

02S Bank 2, Sensor 2 present O2S22_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 2 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

02S Bank 2, Sensor 3 present O2S23_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 1 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

02S Bank 2, Sensor 4 present O2S24_EXISTSSAE J1979Confirmed

  • Request01 13
  • Service 01PID 13
  • Module7E0 → 7E8
  • Every3600 s

Bit 0 of the reply.

Formula
val
Range
0 to 1
Unit
No or yes

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

O2S Output Voltage Bank 1, Sensor 1 O2S11SAE J1979Confirmed

  • Request01 14
  • Service 01PID 14
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 200)
Range
0 to 1.275 V
Unit
V

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022.

O2S Output Voltage Bank 1, Sensor 2 O2S12SAE J1979Confirmed

  • Request01 15
  • Service 01PID 15
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 200)
Range
0 to 1.275 V
Unit
V

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

O2S Output Voltage Bank 2, Sensor 1 O2S21SAE J1979Confirmed

  • Request01 18
  • Service 01PID 18
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 200)
Range
0 to 1.275 V
Unit
V

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022.

O2S Output Voltage Bank 2, Sensor 2 O2S22SAE J1979Confirmed

  • Request01 19
  • Service 01PID 19
  • Module7E0 → 7E8
  • Every1 s

Bits 0 to 7 of the reply, 8 bits.

Formula
(val ÷ 200)
Range
0 to 1.275 V
Unit
V

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022.

SHRTFT associated with O2S11 SHRTFT11SAE J1979Confirmed

  • Request01 14
  • Service 01PID 14
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 128)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022, 2025.

SHRTFT associated with O2S21 SHRTFT21SAE J1979Confirmed

  • Request01 18
  • Service 01PID 18
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 128)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022.

SHRTFT associated with O2S22 SHRTFT22SAE J1979Confirmed

  • Request01 19
  • Service 01PID 19
  • Module7E0 → 7E8
  • Every1 s

Bits 8 to 15 of the reply, 8 bits.

Formula
(val × 100 ÷ 128 − 128)
Range
-100 to 99.22 %
Unit
%

Confirmed for 2017. Supported for 2007 to 2008, 2013, 2018, 2020, 2022.

Keyboard shortcuts

jk/↓↑
Move down or up through a list or a grid.
hl/←→
Move across a row or between cards.
Enter
Open the focused link.
f
Open the current focus area's filter.
↓
In a filter, move to the first result.
Esc
Close a filter or a dialog.
?
Show these shortcuts.